• Title/Summary/Keyword: Current power generation

Search Result 1,270, Processing Time 0.115 seconds

MPPT Using P&O Control in PhotoVoltaic Generating System (태양광 발전 시스템에서의 P&O를 이용한 최대전력점 추종제어)

  • Ryu, Leekwang;Jung, Inho;Bae, Wooju;Koo, Kyoseon;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.370-371
    • /
    • 2018
  • Recently, interest in renewable energy is increasing due to energy depletion and environmental problems. Among them, solar energy is the most popular feature for its infinite, eco-friendly, easy to maintain and high utilization. In these solar power systems, solar cells have either a current-voltage characteristic curve or a power-voltage characteristic curve with non-linear properties. Therefore, the Maximum Power Point Tracking (MPPT) technique is important to control this. In this thesis, we will discuss MPPT techniques using a boost converter and demonstrate their behavior using the PSIM program. Also, the MPPT control algorithm for solar energy generation will be proposed.

  • PDF

Analysis of Module Mismatch Loss in Solar PV String and Feasibility Study for Improvement Method (태양광 PV 스트링에서의 모듈 부정합 손실의 분석 및 개선 기법 타당성 연구)

  • Ahn, Hee-Wook
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.58-63
    • /
    • 2009
  • In this paper, the power loss due to PV module mismatch in PV string is analyzed and a mismatch compensation method is proposed to improve the efficiency of PV system. The analysis of mismatch loss using PV model simulation reveals that the mismatch module may decrease the total efficiency because the MPPT function of power conditioner make the PV system operate at the local maximum point. The mismatch loss can be severe if the maximum power point current of mismatch module is less than that of string. The proposed compensation method which is simply implemented with a buck type converter shows the possibility to remove the mismatch loss. The effectiveness of the analysis and compensation method is verified by a prototype experiment.

Analysis on the Trade-off between an Hydro-power Project and Other Alternatives in Myanmar

  • Aye, Nyein Nyein;Fujiwara, Takao
    • Asian Journal of Innovation and Policy
    • /
    • v.8 no.1
    • /
    • pp.31-57
    • /
    • 2019
  • Myanmar's current power situation remains severely constrained despite being richly endowed in primary energy sources. With low levels of electrification, the demand for power is not adequately met. Cooperation in energy has been a major focus of future initiative for all developed and developing nations. If we want to solve climate change, and change our energy infrastructure, we need to be innovative and entrepreneurial in energy generation. This paper will help us in examining Bayesian MCMC Analysis for the parameters estimation among the arrival rates of disaster occurrences, firm's expected income-based electricity tariffs, and estimated R&D investment expenses in new energy industry. Focusing on Japan's electric power business, we would like to search the potential for innovative initiatives in new technological energy industry for the regional development and ecological sustainability in Myanmar.

Performance Comparison of Different Solar Array Simulator Control by Ellipse Approximation (태양광패널 모사장치의 제어방식에 따른 소신호 특성 비교 분석)

  • Wellawatta, Thusitha;Seo, Young-Tae;Choi, Sung-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.1
    • /
    • pp.16-24
    • /
    • 2021
  • Solar array simulator (SAS) is essential equipment in testing and evaluating the power processing performance of a power conditioning system. However, the nonlinearity in the current(I)-voltage(V) characteristic makes the control loop design of SAS a challenging task. Conventionally, only the inner loop is usually considered in the control design approach. However, this study proves that the reference generation loop also interacts with the inner loop and plays a key role in the overall performance of the SAS. In this paper, the performance of voltage-mode control and impedance control, which are two of the most popular architectures for the SAS system, are reviewed and compared by multi-loop analysis.

A study on the power plant system combined with PEM fuel cell and the wasted hydrogen from the sea water electrolyzer of nuclear power plants (원자력 발전소의 해수전해설비 폐수소를 활용한 PEM 연료전지 발전 시스템에 관한 연구)

  • Choi, Jongwon;Lee, Juhyung;Cha, Sukwon;Kim, Minsoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.124.2-124.2
    • /
    • 2010
  • Generally, a coolant of the nuclear power plant is manufactured by electrolyzing the sea water near the plant for making the sodium hypochlorite(NaOCl), which is used for sterilizing the bacteria and the shellfishes sticking to the drains or the pumps at the outlet of the cooling system due to $8-10^{\circ}C$ warmer temperature than the inlet sea water. During manufacturing the sodium hypochlorite, the hydrogen with the high purity is also produced at the anode side of the electrolyzer. This paper describes a novel power plant system combined with the polymer electrolyte membrane(PEM) fuel cell, the wasted hydrogen from the sea water electrolyzer and the wasted heat of the nuclear power plant. The present status over the exhausted hydrogen at twenty nuclear power plants in Korea was investigated in this study, from which an available power generation is estimated. Furthermore, the economic feasibility of the PEM fuel cell power plant is also evaluated by a current regulations over the power production and exchange using a renewable energy shown in Korea Power Exchange(KRX).

  • PDF

Direct Power Control of a DFIG in Wind Turbines to Improve Dynamic Responses

  • Jou, Sung-Tak;Lee, Sol-Bin;Park, Yong-Bae;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.781-790
    • /
    • 2009
  • This paper presents an implementation of a direct active and reactive power control for a doubly fed induction generator (DFIG), which is applied to a wind generation system as an alternative to the classical field-oriented control (FOC). The FOC has a complex control structure that consists of a current controller, a power controller and frame transformations. The performance of the FOC depends highly on parameter variations of the rotor and stator resistances and the inductances. The proposed direct power control (DPC) method produces a fast and robust power response without the need of complex structure and algorithms. One drawback, however, is its high power ripple during a steady state. In this paper, active and reactive power controllers and space-vector modulation (SVM) are combined to replace hysteresis controllers used in the original DPC drive, resulting in a fixed switching frequency of the power converter. Simulation results with the FOC and DPC for a 3kW DFIG are given and discussed, and the experimental results of a test involving identical machines are presented to illustrate the feasibility of the proposed control strategy.

Analysis of Motor-Current Spectrum for Fault Diagnosis of Induction Motor Bearing in Desulfurization Absorber (탈황 흡수탑 유도전동기 베어링 결함 진단을 위한 전류 스펙트럼 해석)

  • Bak, Jeong-Hyeon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.11 no.2
    • /
    • pp.39-44
    • /
    • 2015
  • According to a research that is based on a previous study, But in a different way, This study shows fault diagnosis of Induction motor bearing which runs in coal-fired power plant industries on Desulfurization absorber agitator using Spectrum analysis of Stator Current and visual inspection. As a result of harmonic content analysis of stator current spectrum, It was possible to detect ball and outer race fault frequency. The comparison in the context of this experiment proves that the amplitude of faulty frequency is increased in three times at a fault in ball and in outer race. Spectrum analysis of stator current can be used to detect the presence of a fault condition as well as experiment in faulty bearings, besides early fault detection in bearings can prevent unexpected power generation loss and emergency maintenance cost.

  • PDF

Modeling for Discovery the Cutoff Point in Standby Power and Implementation of Group Formation Algorithm (대기전력 차단시점 발견을 위한 모델링과 그룹생성 알고리즘 구현)

  • Park, Tae-Jin;Kim, Su-Do;Park, Man-Gon
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.1
    • /
    • pp.107-121
    • /
    • 2009
  • First reason for generation of standby power is because starting voltage must pass through from the source of electricity to IC. The second reason is due to current when IC is in operation. Purpose of this abstract is on structures of simple modules that automatically switch on or off through analysis of state on standby power and analysis of cutoff point patterns as well as application of algorithms. To achieve this, this paper is based on analysis of electric signals and modeling. Also, on/off cutoff criteria has been established for reduction of standby power. To find on/off cutoff point, that is executed algorithm of similar group and leading pattern group generation in the standby power state. Therefore, the algorithm was defined as an important parameter of the subtraction value of calculated between $1^{st}$ SCS, $2^{nd}$ SCS, and the median value of sampling coefficient per second from a wall outlet.

  • PDF

The Switching Characteristic and Efficiency of New Generation SiC MOSFET (차세대 전력반도체 SiC MOSFET의 스위칭 특성 및 효율에 관한 연구)

  • Choi, Won-mook;Ahn, Ho-gyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.2
    • /
    • pp.353-360
    • /
    • 2017
  • Recently, due to physical limitation of Si based power semiconductor, development speed of switching power semiconductors is falling and it is difficult to expect any further performance improvements. SiC based power semiconductor with superior characteristic than Si-based power semiconductor have been developed to overcome these limitations. however, there is not method to apply for real system. Therefore, suggested the feasibility and solution for SiC-based power semiconductor system. design to 1kW class DC-DC boost converter and demonstrated the superiority of SiC MOSFET under the same operating conditions by analyzing switching frequency, duty ratio, voltage and current, and comparing with Si based power semiconductor through experimental efficiency according to each system load. The SiC MOSFET has high efficiency and fast switching speed, and can be designed with small inductors and capacitors which has the advantage of volume reduction of the entire system.

System Development of a 100 kW Molten Carbonate Fuel Cell III (System Control and Operation Mode) (100 kW급 용융탄산염 연료전지 시스템 개발 III (시스템 제어 및 운전모드))

  • Lim, Hee-Chun;Ahn, Kyo-Sang;Seo, Hai-Kyung;Eom, Yeong-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1350-1352
    • /
    • 2003
  • For developing a 100 kW MCFC power generation system, Several design parameters for a fuel cell stack and system analysis results by Cycle Tempo, a processing computer soft ware, were described. Approximately two substacks with 90 cells are required to generate 100 kW at a current density of $125\;mA/cm^2$ with $6000\;cm^2$ of cells. An overall heat balance was calculated to predict exit temperature. The 100 kW power is expected only under pressurized operation condition at 3 atm. Recycle of cathode gas by more than 50% is recommended to run the stack at $125\;mA/cm^2$ and 3 atm. Manifolds should be designed based on gas flow rates for the suggested operating condition. The fuel cell power generation system was designed conceptually with several choices of utilization of anode exhaust gas. To operate and evaluate the MCFC system, control and measurement system and operation mode are designed before 100 MCFC system construction. In system control schematics, OS, PLC and MMI were consisted and have roles for MCFC system control. For operation of 100 kW MCFC system, NS, PS PR mode were considerated step by step and simulated.

  • PDF