• 제목/요약/키워드: Current load

검색결과 3,976건 처리시간 0.037초

저압 시스템에서 비선형 부하의 사용에 따른 고조파 전류 해석 (Analysis of harmonics current using non-linear load at low voltage system)

  • 김종겸;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.13-16
    • /
    • 2001
  • This paper describes the problems associated with the use of PWM ASDs to drive induction motors. A major effect of harmonic voltages and currents in induction motors is increased heating due to iron and copper losses at harmonic frequencies. The harmonic components thus affect the motor efficiency, and can also affect the torque developed. In order to investigate the effect of harmonics which is caused by using of nonlinear load at the low voltage system, we fixed up simple load model and measured the voltage and current. Measurement. results show that additional operation of linear load at the parallel bus in using nonlinear load such as ASD is helpful to the reduction of harmonic current.

  • PDF

고속 블렌더 머신용 BLDC 모터의 가변속 제어 방법 (A Variable Speed Control Scheme of a BLDC Motor for the High-Speed Blender Machine)

  • 배종남;안진우;이동희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.57-59
    • /
    • 2018
  • This paper presents a novel reference variable speed control scheme of a BLDC motor for the high-speed blender machine according to the current limit. Because of a pulsating load variation of a high-speed blender machine, the actual speed is pulsated by the current limit in the high-speed region. The proposed control scheme uses a variable reference speed to reduce the speed variation from the current limit in the constant power region. The pulsated load is occurred at the material crushing, then the pulsated load is reduced after grinding. The reference speed is smoothly reduced at the pulsated load variation, then the enough torque can make a constant speed during crushing. When the pulsating load is reduced, the reference speed is automatically increased to the original speed value. The proposed control scheme is verified by experimental result by practical blender machine.

  • PDF

Design of a Variable Inductor Using MR Fluid Gap for Wide Load Range Efficiency Improvement of a Soft-Switching High-Power Density Bidirectional Dc-Dc Converter

  • Ahmed, Furqan;Kim, Su-Han;Cha, Honnyong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.184-185
    • /
    • 2013
  • In this paper, design of a variable inductor using MR Fluid Gap is proposed for wide load range efficiency improvement of a bidirectional DC-DC converter. As compared to conventional constant value inductor designed to have negative current for ZVS at heavy load but suffers high losses at light load due to its small inductance, the proposed variable inductor not only have small inductance at high current for ZVS but also it has large inductance at low current to decrease light load losses.

  • PDF

3상 4선식 부하설비의 전압, 전류 및 부하 불평형율 측정 분석 (The measurement & Analysis of Voltage, Current and Load Unbalance Factor at Three Phase Four Wire Load System)

  • 김종겸;박영진;이동주;이종한;정종호;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.28-30
    • /
    • 2005
  • This paper presents a scheme on the characteristics of voltage and current unbalance factor under the load variation at the three phase 4-wire system. The voltage unbalance factor of the three-phase 4-wire system is approved by the field measurement. This system is composed of three one-phase transformer with each other capacity. Current unbalance factor is measured by the power quality measurement apparatus and compared by the load unbalance factor. Each phase has an impedance each other by the unbalanced load operation pattern and give rise to voltage unbalance.

  • PDF

배전계통에서의 최적 부하절체를 위한 전문가 시스템 (An Expert System for Optimal Load Transfer in Distribution Systems)

  • 문영현;최병윤;김세호
    • 대한전기학회논문지
    • /
    • 제39권9호
    • /
    • pp.903-911
    • /
    • 1990
  • When load areas on a feeder are deenergized due to faults and scheduled outage, operators need to identify neighboring feeders, try to restore customers and minimize out-of-service areas. These cases include knowledge of system states and various constraints such as voltage drop. This paper concerns the load transfer in fault restoration and scheduled outage. Also, the operating constraints such as line current capacity, relay trip current, transformer capacity, voltage drop and line loss are considered. This expert system can propose the optimal load transfer method by analyzing the system state and considering the constraints.

  • PDF

미소 누전전류 검출 및 차단제어기 설계 (Development of Control Algorithm and Detection of the Small Leakage Current)

  • 반기종;김낙교
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권3호
    • /
    • pp.161-165
    • /
    • 2004
  • In this paper, we have designed the ground faults detection and interrupting controller at normal condition of AC 120v to 240v rating voltage. Ground faults in electrical network have the characteristics of low current, 60㎐ frequency to 2㎑frequency. The load condition are no load and 20A load. The trip level of the controller is 6㎃ with ground faults. The Controller algorithm is implemented using pic16c71 microprocessor.

PLC의 PID 제어에 의한 자동차용 타이어 하중제어에 관한 연구 (Development for Tire Load Control System using PLC PID function)

  • 이기성;정태원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2352-2354
    • /
    • 2003
  • An apparatus and method for imposing a desired average radial force on tire by calculating the current average force between the tire and load wheel based on the average radial force and radial distance between the tire load wheel over the last previous complete revolution of the tire, the spring constant of the tire and the current radial distance between the tire and the load wheel.

  • PDF

Single-Switch Buck Converter with a Ripple-Free Inductor Current

  • Do, Hyun-Lark
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.507-511
    • /
    • 2011
  • This paper presents a single-switch buck converter with a ripple-free inductor current. In the proposed converter, the filter inductor current ripple is completely removed by utilizing an auxiliary circuit consisting of an additional winding of the filter inductor, an auxiliary inductor, and an auxiliary capacitor. Moreover, the ripple-free current characteristic is maintained under both light load and full load conditions. The theoretical analysis and performance of the proposed converter were verified with a 110W experimental prototype operating at a 107 kHz switching frequency.

위성전원분배를 위한 LCL 동작 파라미터 설정분석 (The Analysis of the LCL Set-up Parameters for Satellite Power Distribution)

  • 임성빈;전현진;김경수;김태윤
    • 항공우주기술
    • /
    • 제10권2호
    • /
    • pp.56-64
    • /
    • 2011
  • 최근 위성 시스템의 전력분배는 기존의 퓨즈와 릴레이로 구성된 것과는 달리 LCL(Latching Current Limiter) 회로로 구현되어, 각각의 부하전원을 단속한다. LCL은 부하에서 생기는 과전류를 제한함으로서 고장 의심이 있는 부하를 물리적으로 차단하는 기존 방법에 비하여 고장의 원인을 분석하고, 일시적인 고장인 경우 부하를 재사용할 수 있는 장점이 있다. 그러나 LCL 회로는 전자소자로 구현되는 만큼 주변회로(부하회로)와의 연동성과 회로 자체의 특성을 이해해야 하며, 무엇보다 과전류를 차단하기 위하여 설정하는 LCL 동작 파라미터의 정의를 위한 기술적인 접근이 요구된다. 따라서 본 논문에서는 전력분배 모듈의 LCL 동작 파라미터를 정의하기 위한 분석을 수행했고, 회로구현 및 특성 시험결과를 나타냈다.

저압 모의선로에 소형발전원 연계시 특성 (Connected Characteristics for Small Generation Source of Low Voltage Model Grids)

  • 이상우;강진규;이동하;박태준
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.45-53
    • /
    • 2013
  • In this paper, we analyze the typical phase voltage and line current waveform characteristics of the distribution system with 3 phase small synchronous generation source in case with load and non-load group, in order to investigate the power quality for end load connected of generation source. As demonstrated by our experimental results, the distortion and power quality of phase voltage and line current waveform were relatively good for low voltage 3 phase model grids connected of 3 phase small synchronous generation source in case with non-load group. However, distortion and power quality of voltage and current waveform was poor for low voltage 3 phase model grids connected to 3 phase small synchronous generation source in the load group with some phase voltage and frequency difference. From the above results, we conclude that the phase voltage and frequency of 3 phase generation source must be identical to that of distribution system source to maximize the power quality. Also, special attention is required in case of having load group or non-load group to 3 phase generation source.