• Title/Summary/Keyword: Current harmonics

Search Result 897, Processing Time 0.03 seconds

Analysis on the Operation Characteristics of Induction Motor Operated by Unbalanced Voltage with Harmonics Components (고조파 성분이 포함된 전압 불평형 운전시 유도전동기의 동작 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.3
    • /
    • pp.134-140
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are usually balanced and connected to three power systems. However, in the user power distribution systems, partial loads are single & three phase and unbalanced, generating voltage unbalance by the impedance mismatching. Voltage unbalance has detrimental effects on three-phase induction motors, including over heating, line-current unbalance, derating, torque pulsation, low efficiency, etc. This paper presents a scheme on operation states of a three-phase induction motor under the unbalanced voltages with harmonics components. Three-phase voltages applied to the stator winding of the studied induction motor are controlled by respectively adjusting not only fundamental but also harmonics components. Harmonic components at the voltage unbalanced factor(VUF) of the three-phase source voltages can then be examined the different values of VUF on machine's operation characteristics.

Characteristic analysis of Interior Permanent Magnet Synchronous Motors Considering Voltage Harmonics (전압 고조파를 고려한 매입형 영구자석 동기전동기의 d-q 등가회로 해석)

  • Kwon, Soon-O;Lee, Geun-Ho;Lee, Woo-Taik;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.985-986
    • /
    • 2011
  • This paper deals with d-q axis equivalent circuit analysis of IPMSM(Interior Permanent Magnet Synchronous Motors) considering voltage harmonics. In the field weakening region, as the current vector angle increased, back-emf contains large harmonics, therefore, significant underestimation of voltage or overestimation of speed can be occurred from the conventional d-q axis equivalent circuit analysis. In order to consider the effects of voltage harmonics, a harmonic coefficient is introduced and verified by experiments.

  • PDF

A Study on the Harmonics Effect of Disc-Type Over Current Ground Relay for Emergency Generator Protection (비상발전기 보호용 원판형 지락과전류계전기의 고조파영향에 관한 연구)

  • Kim, Kyung-Chul;Kho, Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.58-62
    • /
    • 2015
  • When an emergency generator is running, it supplies the power for critical loads. Generator protection requires the consideration of many abnormal conditions that may occur with generators include overvoltages and ground faults. Modern day power systems create harmonics within the electrical network that can have an impact upon the associated protective system. This paper focuses on the analysing of the cause and development of a solution for the malfunction of induction disc type overcurrent ground relay by generation of harmonics during emergency generator operation.

FFT analysis About 3 Phase square - wave inverter Using the Matlab (Matlab을 이용한 3상 구형파 인버터 출력단의 FFT분석)

  • Choi, Hyun-Young;Oh, Se-Ho;Ryu, Hyoung-Sun;Kim, Hyun;Son, Yoon-Rak;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1058-1060
    • /
    • 2001
  • The purpose of this paper is to analyze the harmonics of power electronics equipment, especially 3 phase square-wave inverter. In this paper, we simulated 3 phase square-wave inverter by using the matlab and analyzed the simulated output waveforms to analyze the harmonics included in the inverter. In the matlab we expressed to amplitude and phase of harmonics current, and calculated to total harmonics distortion of out voltage.

  • PDF

Analysis on the Harmonics Characteristics due to increase & decrease of Nonlinear load (비선형 부하의 증감에 따른 고조파 특성 분석)

  • Kim, Jong-Gyeum;Lee, Eun-Woong;Kim, Il-Jung;Kim, Seong-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.87-91
    • /
    • 2003
  • Most of the loads in industrial power distribution systems are balanced and connected to three wires power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating a large amount of non-characteristic harmonics. With the advent of power electronics and proliferation of non-linear loads in industrial power applications, power harmonics and their effects on power quality are a topic of concern. Harmonics by the unbalance voltage and non-linear loads, cause the increase of machine loss and heating. In order to allow current harmonic compensation, a filter must be installed. This paper describes the performance of passive filter under the voltage unbalance and non-linear load.

  • PDF

SRM drive system with reduced harmonics and improved power factor (고조파감소 및 역률개선을 위한 SRM 구동시스템에 관한 연구)

  • 신규재;권영안;임근희
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.10
    • /
    • pp.151-157
    • /
    • 1997
  • Switched relutance motor(SRM) has the advantages of simple structure, low rotor intertia, and high power rate per unit volume. However, SRM has the disadvantages of high current harmonics, and low power factor because of the discontinuous excitation of pulse type. The harmonics brings about the distortion and loss of power system, and brings about the incorrect opertion of electronic system. This paper investigates the SRM drive system with the reduced harmonics and improved power factor. The system consists of the switching power converter with poewr factor correction(SPC-PFC), DC/DC converter and 3-phase inverter. The performances in the proposed system are verified through the simpuation and experiment.

  • PDF

Harmonics Reduction in the High-Speed Synchronous Reluctance Motor by Space-Vector PWM Control

  • Oh, Sung-Up;Kim, Min-Tae;Seong, Se-Jin;Paek, Tong-Ki
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.758-762
    • /
    • 1998
  • Many harmonics components are contained within the stator currents of the high-speed synchronous reluctance motor, SynRM, with salient pole rotor. They cause the power factor of SynRM to get worse. In this paper, the mathematical model of SynRM is investigated, and SV_PWM control method is applied to reduce harmonics components in the stator current. Simulation results show the fast response of speed and the reduction of harmonics components at steady state.

  • PDF

A Novel Photovoltaic Power Generation System including the Function of Shunt Active Filter

  • Park, Minwon;Seong, Nak-Gueon;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.2
    • /
    • pp.103-110
    • /
    • 2003
  • With significant development of power electronics technology, the proliferation of nonlinear loads such as static power converters has deteriorated power quality in power transmission and distribution systems. Notably, voltage harmonics resulting from current harmonics produced by the nonlinear loads have become a serious problem in many countries. Many photovoltaic power generation systems installed in building systems have harmonics that are the worst object for distribution systems as a utility interactive system, and it tends to spread out continuously. Proposed and implemented in this paper is a multi-function inverter control strategy that allows a shunt active filter function to the power inverter of the photovoltaic power generation system established on a building system. The effectiveness of the proposed system is demonstrated through the simulation of a hypothetical power system using PSCAD/EMTDC.

A study on the method of Air gap field Analysis considering slot harmonics in the electric machine (슬롯 고조파를 고려한 전기기계 공극자계의 해석 방법에 관한 연구)

  • Im, Dal-Ho;Kim, Saeng-Soo;Kim, Young-Joong;Yoon, Sang-Baeck
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.33-36
    • /
    • 1987
  • Is this study it is proposed a method which is able to compute preciously using time-difference method to the air-gap magnetic field in electric machines take into account of eddy current induced. The air-gap magnetic field has slot harmonics which are due to the structure of machines and the shape of slot harmonics varies with the related positions of slots when the rotor moves. Accordingly, considering the influence of slot-harmonics, we coupled macro-air-gap element with first-order triangular elements in domain and used direct-convergence method for magnetic saturation.

  • PDF

Analysis on the Harmonic Characteristics of Nonlinear Load Operated by Unbalance Voltage (불평형 전압으로 운전하는 비선형 부하의 고조파 특성 분석)

  • 김종겸;이은웅;이동주
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.10
    • /
    • pp.491-500
    • /
    • 2003
  • Most of the loads in industrial power distribution systems are balanced and connected to three wires power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating a large amount of non-characteristic harmonics. With the advent of power electronics and proliferation of non-linear loads in industrial power applications, power harmonics and their effects on power quality are a topic of concern. Harmonics by the unbalance voltage and non-linear loads, cause the increase of machine loss and heating. In order to allow current harmonic compensation, a filter must be installed. This paper describes the performance of passive filter under the voltage unbalance and non-linear load.