• 제목/요약/키워드: Current harmonic

검색결과 1,338건 처리시간 0.037초

새로운 마그네틱 피드백 기법을 이용하여 낮은 링크 전압을 갖는 새로운 단일 전력단 역률 개선 AC/DC 컨버터 (Novel Single-Stage Power Factor Correction AC/DC Converter with Low DC Link Voltage using New Magnetic Feedback Technique)

  • 최은석;윤현기;김정은;문건우;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.528-532
    • /
    • 2004
  • Novel single-stage power factor correction AC/DC converter with low DC link voltage using new magnetic feedback technique is proposed in this paper. The Proposed converter has high power factor, tight output voltage regulation and low link capacitor voltage less than 450V for all the load range through the universal input line. This converter has also no dead-zone in the input current, which is seen in the conventional converter using the previous magnetic feedback technique. In this paper, the analysis of operations and features of the proposed converter is provided, and the experimental results of 90W-prototype shows the low harmonic distortions satisfied with EN 61000-3-2 Class D, high power factor and low link voltage less than 450V.

  • PDF

Experimental identification of the six DOF C.G.S., Algeria, shaking table system

  • Airouche, Abdelhalim;Bechtoula, Hakim;Aknouche, Hassan;Thoen, Bradford K.;Benouar, Djillali
    • Smart Structures and Systems
    • /
    • 제13권1호
    • /
    • pp.137-154
    • /
    • 2014
  • Servohydraulic shaking tables are being increasingly used in the field of earthquake engineering. They play a critical role in the advancement of the research state and remain one of the valuable tools for seismic testing. Recently, the National Earthquake Engineering Research Center, CGS, has acquired a 6.1m x 6.1 m shaking table system which has a six degree-of-freedom testing capability. The maximum specimen mass that can be tested on the shaking table is 60 t. This facility is designed specially for testing a complete civil engineering structures, substructures and structural elements up to collapse or ultimate limit states. It can also be used for qualification testing of industrial equipments. The current paper presents the main findings of the experimental shake-down characterization testing of the CGS shaking table. The test program carried out in this study included random white noise and harmonic tests. These tests were performed along each of the six degrees of freedom, three translations and three rotations. This investigation provides fundamental parameters that are required and essential while elaborating a realistic model of the CGS shaking table. Also presented in this paper, is the numerical model of the shaking table that was established and validated.

LG 공진회로를 이용한 사이크로컨버터의 휴지기간 없는 극성절환 방법에 관한 연구 (A Study on the Polarity Changing Method without Dead Time of a Cycloconverter with an LC Resonant Circuit)

  • 최정수;조규민;김영석
    • 전자공학회논문지S
    • /
    • 제35S권9호
    • /
    • pp.111-117
    • /
    • 1998
  • 본 논문은 LC공진회로를 이용한 사이크로컨버터의 휴지기간 없는 극성절환 방법에 관한 것이다. 제안한 방법에 따르면 극성절환시 회로단락을 방지하기 위한 휴지기간이 요구되지 않는다. 따라서 제어지연 및 출력전류의 고조파성분이 감소하게 된다. 그리고 제안한 방법은 비순환전류형의 다른 자연전류형 사이크로컨버터에도 확장될 수 있다. 본 논문에서는 휴지기간 없는 극성절환의 스위칭 방법에 대하여 검토하였으며 제안한 방법의 유용성을 확인하기 위하여 LC공진회로를 이용한 사이크로콘버터에 적용실험을 수행하였다.

  • PDF

Control and Analysis of Vienna Rectifier Used as the Generator-Side Converter of PMSG-based Wind Power Generation Systems

  • Zhao, Hongyan;Zheng, Trillion Q.;Li, Yan;Du, Jifei;Shi, Pu
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.212-221
    • /
    • 2017
  • Permanent-Magnet Synchronous Generators (PMSGs) are used widely in Wind Power Generation Systems (WPGSs), and the Vienna rectifier was recently proposed to be used as the generator-side converter to rectify the AC output voltage in PMSG-based WPGS. Compared to conventional six-switch two-level PWM (2L-PWM) converters, the Vienna rectifier has several advantages, such as higher efficiency, improved total harmonic distortion, etc. The motivation behind this paper is to verify the performance of direct-driven PMSG wind turbine system based-Vienna rectifier by using a simulated direct-driven PMSG WPGS. In addition, for the purpose of reducing the reactive power loss of PMSGs, this paper proposes an induced voltage sensing scheme which can make the stator current maintain accurate synchronization with the induced voltage. Meanwhile, considering the Neutral-Point Voltage (NPV) variation in the DC-side of the Vienna rectifier, a NPV balancing control strategy is added to the control system. In addition, both the effectiveness of the proposed method and the performance of the direct-driven PMSG based-Vienna rectifier are verified by simulation and experimental results.

2축 마이크로 플럭스게이트 센서 제작을 통한 전자 나침반 개발 (Development of Electronic Compass Using 2-Axis Micro Fluxgate Sensor)

  • 박해석;심동식;나경원;황준식;최상언
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권9호
    • /
    • pp.418-423
    • /
    • 2003
  • This paper describes an electronic compass using micromachined X- and Y-axis micro fluxgate sensors which were perpendicularly aligned each other to measure X- and Y-axis magnetic fields respectively. The fluxgate sensor was composed of rectangular-ring shaped magnetic core and solenoid excitation(49 turns) and pick-up(46 turns) coils. Excitation and pick-up coil patterns which were formed opposite to each other wound the magnetic core alternatively to improve the sensitivity and to excite the magnetic core in an optimal condition with reduced excitation current. The magnetic core has DC effective permeability of ~1000 and coercive field of ~0.1 Oe. The magnetic core is easily saturated due to the low coercive field and closed magnetic path for the excitation field. To decrease the difference of induced second harmonic voltages from X- and Y-axis, excitation condition of 2.8 $V_{P-P}$ and 1.2 MHz square wave was selected. Excellent linear response over the range of -100 $\mu$T to +100 $\mu$T was obtained with 210 V/T sensitivity. The size of each micro fluxgate sensor excluding pad region was about 2.6${\times}$1.7 $mm^2$ and the power consumption was estimated to be 14 mW.W.

HVDC용 12-펄스 위상제어정류기의 새로운 게이트 펄스 발생 기법 (A New Gate Pulse Generating Method of 12-Pulse Phase Controlled Rectifier for HVDC)

  • 안종보;김국헌;이종무;이기도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.139-141
    • /
    • 2000
  • High voltage direct current(HVDC) transmission system uses the phase controlled rectifier triggered by means of IPC(individual phase control) or EPC(equidistant pulse control). Most HVDC system has adopted EPC method that can solve the harmonic instability problem of IPC method in weak power system. But EPC has inherent indirect synchronizing problem requiring the closed loop control. This paper presents the new gate pulse generating method for 12-pulse HVDC converter, which combines IPC with EPC. Simulation and test results are presented. The basic concept is that it generates the gating pulse for 12-pulse converter by synthesizing the internal phase reference using the frequency and phase information of a sin91e phase voltage. To ensure the reliability of the external phase input, Potential transformer that detects the phase voltage has redundancy. Using fault detecting algorithm the healthy input is always guaranteed. And the frequency compensation function was reinforced.

  • PDF

후두적출술 환자의 발성법에 따른 음향학적 특성 (Acoustic Characteristics of Patients with Total Laryngectomees via Voice Rehabilitation Techniques)

  • 장효령;심희정;고도흥
    • 말소리와 음성과학
    • /
    • 제5권4호
    • /
    • pp.25-32
    • /
    • 2013
  • This research is aimed at finding the acoustic characteristics of different voice rehabilitation techniques, the electrolaryx (EL), standard esophageal (SE), and tracheoesophageal (TE), used on 17 patients with laryngectomees. The analysis of the voice qualities was achieved using MDVP. In order to compare the acoustic characteristics, patients were asked to produce the vowel /a/ sound. The acoustic analysis included fundamental frequency (f0), jitter, shimmer, and noise-to-harmonic ratio (NHR). The main acoustic results showed no significant statistical differences between the average measurements of SE and TE speakers. It was found that the current study showed the same tendency found in previous studies. There was also a significant difference between SE and EL speakers. On the other hand, there were no significant statistical differences between the average measurements of TE and EL speakers on all acoustic measurements. This research will contribute to establishing a baseline related to speech characteristics in voice rehabilitation for patients with laryngectomees. In future, the present findings and issues should be considered in the context of gender. Specifically, the number of women who are diagnosed with laryngeal cancer continues to rise and their acoustic characteristics may indeed differ from those of men.

MgO와 $Fe_2O$가 첨가된$ LiNbO_3$ 단결정에서 제 2 고조파 발생을 이용한 공간전하장의 직접 측정 (Direct measurement of Space-charge field in a $LiNbO_3$ crystal doped with MgO and $Fe_2O$ using second harmonic generation)

  • 김봉기;홍미연;이범구
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2000년도 제11회 정기총회 및 00년 동계학술발표회 논문집
    • /
    • pp.284-285
    • /
    • 2000
  • 광굴절률 현상은 optical signal processing과 홀로그램 기억소자로 널리 응용 될 수 있기 때문에 지금까지 광범위하게 연구되어져 왔다. 광굴절률 현상에서 중요한 변수는 빛이 있는 동안 drift, diffusion 과 photovoltaic current와 같은 전하 운반 메카니즘을 통해서 local charge의 재분포에 따른 공간전하장(Space-charge field, $E_{sc}$ )이다. 지금까지 single beam에 의한 공간전하장을 측정하는 방법으로 birefringenc $e^{1.2}$ 와 interference metho $d^{3}$을 이용하여 굴절률 변화를 측정함으로써 얻을 수 있었다. 그러나 이런 방법들은 공간전하장의 변화를 측정하기위해서 전기광학계수를 측정하여 얻는 간접적인 방법이고 또한 실험방법도 다소 복잡하다. 따라서 본 투고에서는 이미 발표된 광굴절률 현상시 제 2 고조파 세기(SHG)의 변화로부터 공간전하장을 간단하게 측정하는 방법을 이용하여 congruent, MgO가 4mole%, F $e_2$O가 0.1mole% 첨가된 LiNb $O_3$ 단결정의 공간전하장에 대해서 연구를 하였다. 이 방법은 전기광학물질인 LiNb $O_3$에서 SHG 위상정합조건이 dc 전기장에 의존하는 성질을 이용한 것이다. 그리고 온도가 일정할 경우 전기장의 변화에 따라 SHG의 크기가 변함을 이용하였다. (중략)

  • PDF

韓國周邊 海洋鹽分의 年變化 (Annual Variation of Salinity in the Neighbouring Seas of Korea)

  • 강용규;진명신
    • 한국해양학회지
    • /
    • 제19권2호
    • /
    • pp.105-110
    • /
    • 1984
  • 수산진흥원에서 15년간(1961-1975) 정기적으로 관측한 한국 주변 182정점의 염분 자료에 대한 조화 분석을 통하여, 한국 주변 동.서.남해표면과 30메타층 염분의 연변화를 분석하였다. 서해 염분의 연평균은 동해에서 보다 낮으며 남해와 동해에서 대마난류의 하류방향으로 갈수록 염분 연변화의 진폭이 줄어들고 위상이 지연된다. 30메타층의 염분은 표면염분에 비하여 평균치는 높으나, 년교차의 폭이 작고 위상이 지연되고 있다. 한국 주변 남해와 동해 염분의 연변화는 주로 국지적 강우량 및 양자강 담수 유출의 계절적인 변화 때문에 일어난다.

  • PDF

Design and Analysis of a Material Efficient Sinusoidal Consequent-Pole High-Speed Axial-Flux Machine

  • Kumar, Sunil;Kwon, Byung-il
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.759-766
    • /
    • 2018
  • This paper presents a high-speed axial-flux machine which utilizes the idea of sinusoidal shaped pole combined with a consequent iron-pole. The target of the proposed machine is the cost reduction of the relatively expensive Samarium-Cobalt (SmCo) permanent magnet (PM) material and the torque per PM volume improvement by using sinusoidal consequent-pole rotor. The effectiveness of the proposed machine is validated by comparing it with conventional consequent-pole and with conventional PM machines using 3-D finite element method (FEM) simulations. The comparison and analysis is done in terms of back electro-motive force (back-EMF) harmonic contents, torque per PM volume and torque ripple characteristics. The simulation results show that the proposed machine is suitable and cost-effective for high-speed and high torque per PM volume applications. Furthermore, due to the consequent pole, the magnetic flux saturation and the overload current torque-capability are also presented and discussed in the paper.