• Title/Summary/Keyword: Current distribution imaging

Search Result 59, Processing Time 0.028 seconds

Development of Novel on-line Landweber Algorithm for Image Reconstruction in Electrical Impedance Tomography (전기 임피던스 단층촬영법에서 영상 복원을 위한 새로운 on-line Landweber 알고리즘 개발)

  • Kim, Bong Seok;Kim, Sin;Kim, Kyung Youn
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.293-299
    • /
    • 2012
  • Electrical impedance tomography is an imaging modality for determining the electrical properties inside a domain. Small currents are injected and the resulting voltages are measured through the electrodes. The internal electrical properties are reconstructed based on these voltage and current data. In this paper, a novel on-line Landweber algorithm was developed to fast estimate the resistivity distribution in the inverse calculation. Additionally, to enhance the reconstruction performance, a step-length was computed from the eigenvalue of the weighting matrix. The numerical experiments have been performed to evaluate the reconstruction performance of the proposed method.

Red supergiant stars in NGC 4449, NGC 5055, and NGC 5457

  • Chun, Sang-Hyun;Sohn, Young-Jong;Asplund, Martin;Casagrande, Luca
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.44.2-45
    • /
    • 2016
  • We present near-infrared photometric properties of red supergiant stars (RSGs) in three galaxies NGC 4449, NGC 5055 and NGC 5457. The near-infrared imaging data of WFCAM UKIRT were used and combined with optical archive data to identify the RSGs in the galaxies. We found that the RSGs can be identified from the foreground Galactic stars in (i-K, ri) colour-colour diagram. The effective temperatures and luminosities of the identified RSGs are estimated from JHK photometry using MARCS model. In the H-R diagram, the majority of RSGs in the galaxies are distributed between $logL/L{\odot}=4.8$ and 5.7, and their effective temperature and luminosities agree with the current evolutionary tracks with masses in the range $9-30M{\odot}$. We also compared the spatial distribution of RSGs with the HII regions. A tight spatial correlation between RSGs and HII region was found in NGC 4449 and NGC 5457. We do not find a clear metallicity dependance on the RSG effective temperature in the three galaxies, but the maximum luminosity of the three galaxies is constant at $logL/L{\odot}{\sim}5.6$. Additional spectroscopy data, including photometry are essential to examine whether the physical properties of RSGs change with metallicity.

  • PDF

Prediction of Global Industrial Water Demand using Machine Learning

  • Panda, Manas Ranjan;Kim, Yeonjoo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.156-156
    • /
    • 2022
  • Explicitly spatially distributed and reliable data on industrial water demand is very much important for both policy makers and researchers in order to carry a region-specific analysis of water resources management. However, such type of data remains scarce particularly in underdeveloped and developing countries. Current research is limited in using different spatially available socio-economic, climate data and geographical data from different sources in accordance to predict industrial water demand at finer resolution. This study proposes a random forest regression (RFR) model to predict the industrial water demand at 0.50× 0.50 spatial resolution by combining various features extracted from multiple data sources. The dataset used here include National Polar-orbiting Partnership (NPP)/Visible Infrared Imaging Radiometer Suite (VIIRS) night-time light (NTL), Global Power Plant database, AQUASTAT country-wise industrial water use data, Elevation data, Gross Domestic Product (GDP), Road density, Crop land, Population, Precipitation, Temperature, and Aridity. Compared with traditional regression algorithms, RF shows the advantages of high prediction accuracy, not requiring assumptions of a prior probability distribution, and the capacity to analyses variable importance. The final RF model was fitted using the parameter settings of ntree = 300 and mtry = 2. As a result, determinate coefficients value of 0.547 is achieved. The variable importance of the independent variables e.g. night light data, elevation data, GDP and population data used in the training purpose of RF model plays the major role in predicting the industrial water demand.

  • PDF

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Effects of Information Processing Types and Product Ownership on Usage Intention

  • CHOI, Nak-Hwan
    • The Journal of Industrial Distribution & Business
    • /
    • v.12 no.5
    • /
    • pp.47-58
    • /
    • 2021
  • Purpose - Current research aimed at exploring the effect differences between the two types of processing product information such as the imagining and the considering on psychological product ownership which could influence the intent to purchase or use the product, and focused on identifying the interaction effects of activated memory information type and advertising information type on each of the information processing types. Research design, data, and methodology - This study divided the information processing types into imagining and considering, and the consumer's memories were divided into autobiographical or episodic and semantic memory. The advertising information was approached in each of event information being together with the product and product feature information. At empirical study, 2(two types of memory activation: episodic and semantic memory activation) ∗ 2(two types of advertising information: event-focused and product feature-focused advertising information) between-subjects design was used to make four types of questionnaire according to the type of experimental groups. Through the survey platform, 'questionnaire stars' of 'WeChat' in China, 219 questionnaire data were collected for empirical study. The structural equation model in AMOS 26 and Anova were used to verify hypotheses. Results - First, the ownership affected the usage intent positively. Second, the imagining did not affect the psychological ownership but did directly affect the usage intention, and the considering affected the ownership positively. Third, the episodic memory activation positively influenced the imagining and negatively affected the considering, whereas the semantic memory activation positively influenced the considering and negatively affected the imagining. Fourth, event-advertising information increased the effects of the activated episodic memory on the imagining, and feature-advertising information increased the effects of the activated semantic memory on the considering. Conclusions - marketers should develop and advertise their product-related event message to trigger the imaging that directly increase the intent to purchase or use their product, when consumers are under the activation of their episodic memory. And marketers should advertise their product feature-related message to trigger the considering that could induce consumers' ownership for their product to increase the intent to purchase or use their product, when they are under the activation of their semantic memory.

Usefulness Evaluation of HRCT using Reconstruction in Chest CT (흉부CT 검사 시 HRCT 영상 재구성의 유용성)

  • Park, Sung-Min;Kim, Keung-Sik;Kang, Seong-Min;Yoo, Beong-Gyu;Lee, Ki-Bae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

Concrete Crack Detection Inside Finishing Materials Using Lock-in Thermography (위상 잠금 열화상 기법을 이용한 콘크리트 마감재 내부 균열 검출)

  • Myung-Hun Lee;Ukyong Woo;Hajin Choi;Jong-Chan Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.30-38
    • /
    • 2023
  • As the number of old buildings subject to safety inspection increases, the burden on designated institutions and management entities that are responsible for safety management is increasing. Accordingly, when selecting buildings subject to safety inspection, appropriate safety inspection standards and appropriate technology are essential. The current safety inspection standards for old buildings give low scores when it is difficult to confirm damage such as cracks in structural members due to finishing materials. This causes the evaluation results to be underestimated regardless of the actual safety status of the structure, resulting in an increase in the number of aging buildings subject to safety inspection. Accordingly, this study proposed a thermal imaging technique, a non-destructive and non-contact inspection, to detect cracks inside finishing materials. A concrete specimen was produced to observe cracks inside the finishing material using a thermal imaging camera, and thermal image data was measured by exciting a heat source on the concrete surface and cracked area. As a result of the measurement, it was confirmed that it was possible to observe cracks inside the finishing material with a width of 0.3mm, 0.5mm, and 0.7mm, but it was difficult to determine the cracks due to uneven temperature distribution due to surface peeling and peeling of the wallpaper. Accordingly, as a result of performing data analysis by deriving the amplitude and phase difference of the thermal image data, clear crack measurement was possible for 0.5mm and 0.7mm cracks. Based on this study, we hope to increase the efficiency of field application and analysis through the development of technology using big data-based deep learning in the diagnosis of internal crack damage in finishing materials.

Signal change in hippocampus and current source of spikes in Panayiotopoulos syndrome

  • Yeom, Jung-Sook;Kim, Young-Soo;Park, Ji-Sook;Seo, Ji-Hyun;Park, Eun-Sil;Lim, Jae-Young;Park, Chan-Hoo;Woo, Hyang-Ok;Youn, Hee-Shang;Kwon, Oh-Young
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.2
    • /
    • pp.63-67
    • /
    • 2012
  • A 4-year-old girl with Panayiotopoulos syndrome presented with a history of 4 prolonged autonomic seizures. The clinical features of her seizures included, in order of occurrence, blank staring, pallor, vomiting, hemi-clonic movement on the right side, and unresponsiveness. A brain magnetic resonance imaging (MRI) showed a slightly high $T_2$ signal in the left hippocampus. Interictal electoencephalogram revealed spikes in the occipital area of the left hemisphere. We analyzed the current-source distribution of the spikes to examine the relationship between the current source and the high $T_2$ signal. The current source of the occipital spikes was not only distributed in the occipital area of both cerebral hemispheres, but also extended to the posterior temporal area of the left hemisphere. These findings suggest that the left temporal lobe may be one of the hyperexcitable areas and form part of the epileptogenic area in this patient. We hypothesized that the high $T_2$ signal in the left hippocampus of our patient may not have been an incidental lesion, but instead may be related to the underlying electroclinical diagnosis of Panayiotopoulos syndrome, and particularly seizure. This notion is important because an abnormal $T_2$ signal in the hippocampus may represent an acute stage of hippocampal injury, although there is no previous report of hippocampal pathology in Panayiotopoulos syndrome. Therefore, long-term observation and serial follow-up MRIs may be needed to confirm the clinical significance of the $T_2$ signal change in the hippocampus of this patient.

Current Status and Future Perspective of PET (PET 이용 현황 및 전망)

  • Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • Positron Emission Tomography (PET) is a nuclear medicine imaging modality that consists of systemic administration to a subject of a radiopharmaceutical labeled with a positron-emitting radionuclide. Following administration, its distribution in the organ or structure under study can be assessed as a function of time and space by (1) defecting the annihilation radiation resulting from the interaction of the positrons with matter, and (2) reconstructing the distribution of the radioactivity from a series of that used in computed tomography (CT). The nuclides most generally exhibit chemical properties that render them particularly desirable in physiological studies. The radionuclides most widely used in PET are F-18, C-11, O-15 and N-13. Regarding to the number of the current PET Centers worldwide (based on ICP data), more than 300 PET Centers were in operation in 2000. The use of PET technology grew rapidly compared to that in 1992 and 1996, particularly in the USA, which demonstrates a three-fold rise in PET installations. In 2001, 194 PET Centers were operating in the USA. In 1994, two clinical and research-oriented PET Centers at Seoul National University Hospital and Samsung Medical Center, was established as the first dedicated PET and Cyclotron machines in Korea, followed by two more PET facilities at the Korea Cancer Center Hospital, Ajou Medical Center, Yonsei University Medical Center, National Cancer Center and established their PET Center. Catholic Medical School and Pusan National University Hospital have finalized a plan to install PET machine in 2002, which results in total of nine PET Centers in Korea. Considering annual trends of PET application in four major PET centers in Korea in Asan Medical Center recent six years (from 1995 to 2000), a total of 11,564 patients have been studied every year and the number of PET studies has shown steep growth year upon year. We had 1,020 PET patients in 1995. This number increased to 1,196, 1,756, 2,379, 3,015 and 4,414 in 1996,1997,1998,1999 and 2000, respectively. The application in cardiac disorders is minimal, and among various neuropsychiatric diseases, patients with epilepsy or dementia can benefit from PET studios. Recently, we investigated brain mapping and neuroreceptor works. PET is not a key application for evaluation of the cardiac patients in Korea because of the relatively low incidence of cardiac disease and less costly procedures such as SPECT can now be performed. The changes in the application of PET studios indicate that, initially, brain PET occupied almost 60% in 1995, followed by a gradual decrease in brain application. However, overall PET use in the diagnosis and management of patients with cancer was up to 63% in 2000. The current medicare coverage policy in the USA is very important because reimbursement policy is critical for the promotion of PET. In May 1995, the Health Care Financing Administration (HCFA) began covering the PET perfusion study using Rubidium-82, evaluation of a solitary pulmonary nodule and pathologically proven non-small cell lung cancer. As of July 1999, Medicare's coverage policy expanded to include additional indications: evaluation of recurrent colorectal cancer with a rising CEA level, staging of lymphoma and detection of recurrent or metastatic melanoma. In December of 2001, National Coverage decided to expand Medicare reimbursement for broad use in 6 cancers: lung, colorecctal, lymphoma, melanoma, head and neck, and esophageal cancers; for determining revascularization in heart diseases; and for identifying epilepsy patients. In addition, PET coverage is expected to further expand to diseases affecting women, such as breast, ovarian, uterine and vaginal cancers as well as diseases like prostate cancer and Alzheimer's disease.

Current status and prospects of plant diagnosis and phenomics research by using ICT remote sensing system (ICT 원격제어 system 이용 식물진단, Phenomics 연구현황 및 전망)

  • Jung, Yu Jin;Nou, Ill Sup;Kim, Yong Kwon;Kim, Hoy Taek;Kang, Kwon Kyoo
    • Journal of Plant Biotechnology
    • /
    • v.43 no.1
    • /
    • pp.21-29
    • /
    • 2016
  • Remote Sensing (RS) is a technique to obtain necessary information in a non-contact and non-destructive method by using various sensors on the surface, water or atmospheric phenomena. These techniques combine elements such as sensors, and platform and information communication technology (ICT) for mounting the sensor. ICT has contributed significantly to the success of smart agriculture through quantification and measurement of environmental factors and information such as weather, crop and soil management to distribution and consumption stage, as well as the production stage by the cloud computer. Remote sensing techniques, including non-destructive non-contact bioimaging (remote imaging) is required to measure the plant function. In addition, bioimaging study in plant science is performed at the gene, cellular and individual plant level. Recently, bioimaging technology is considered the latest phenomics that identifies the relationship between the genotype and environment for distinguishing phenotypes. In this review, trends in remote sensing in plants, plants diagnostics and response to environment and status of plants phonemics research were presented.