• Title/Summary/Keyword: Current detection

Search Result 2,493, Processing Time 0.047 seconds

Quantification of Odorants from Animal Husbandry using Solid-phase Microextraction (고상(固相) 미세 추출법에 의한 축산 관리시설에서 발생하는 악취성 가스 화합물의 정량적 평가)

  • Kim, Jae-Hyuck;Choi, Hong-Lim;Kown, So-Young;Lim, Hong-Lae;McConnell, Laura L.;Arispe, Susana;Park, Chul-Hwi;Kim, Hyun-Ook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.158-164
    • /
    • 2006
  • Offensive odor from CAFO(concentrated animal feeding operation) and its control have become a significant issue in Korea. Control of odors from the CAFO requires to identify major odorant and their generation mechanisms. In this study, an easy method to collect gas sample and to quantify its odorants is proposed. The method involves on-site odorant extraction with solid-phase microextraction and quantitation with GC/MSD or GC/FID. Analytes of the current study include: trimethylamine(TMA), carbon disulfide($CS_2$), dimethyl sulfide(DMS), dimethyl disulfide(DMDS), acetic acid(AA), propionic acid(PA) and n-butyric acid(BA). The resulting linearity($R^2$) of calibration curve for each analyte was good over the range from several ppbv to ppmv; 0.984 for TMA(0.056-1.437), 0.996 for $CS_2$(0.039-0.999), 0.994 for DMS(0.029-0.756), 0.995 for DMDS(0.024-0.623), 0.992 for AA(0.068-1.314), 0.955 for PA(0.047-0.940), and 0.976 for BA(0.036-0.712). Method detection limits were 5.67, 6.39, 5.78, 25.2, 0.098, 0.363 and 0.099 ppbv for AA, PA, BA, TMA, DMS, $CS_2$, and DMDS, respectively. With the developed method, odorants from poultry, swine, and cattle barns were analysed. All the compounds but DMDS were detected from the sample collected in the poultry barn, and their levels exceeded the representative published human olfactory threshold.

Calculation of Derived Investigation Levels for Uranium Intake (우라늄 섭취의 유도조사준위 산출)

  • Lee, Na-Rae;Han, Seung-Jae;Cho, Kun-Woo;Jeong, Kyu-Hwan;Lee, Dong-Myung
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.68-77
    • /
    • 2013
  • Derived Investigation levels(DILs) were calculated to protect the workers from the effects of both radiological hazard and chemical toxicity by uranium intake. Investigation Levels(ILs) of committed effective dose of 2 mSv $y^{-1}-6$ mSv $y^{-1}$ and uranium concentration of 0.3 ${\mu}g$ $g^{-1}$ in kidney, based on Korean Nuclaer Safety Act, Korean Occupational Safety and Health Act and current scientific studies of uranium intake were assumed. DILs of radiological hazard and chemical toxicity were then calculated based on the concentration of uranium in air of workplace, the lung monitoring and urine analysis, respectively. As a result, in case of the nuclear fuel fabrication plant where 3.5% enriched uranium is handled, derived investigation level(DIL) for the control of the concentration of uranium in the air of workplace assumed with 15-min acute inhalation was 0.6 mg $m^{-3}$ for all types of uranium. DILs for the control of the average concentration of uranium in air of workplace, assuming an 8-hour workday, were 15.21 ${\mu}g$ $m^{-3}$ of Type F uranium, 0.41-1.23 Bq $m^{-3}$ and 0.13-0.39 Bq $m^{-3}$ for Type M and Type S uranium, respectively. DILs for the lung monitoring assumed with a period of 6-month interval were 0.37-1.11 Bq and 0.39-1.17 Bq in acute and chronic inhalation for Type M, respectively and 0.30- 0.91 Bq and 0.19-0.57 Bq in acute and chronic inhalation for Type S, respectively. Since a detection limit of typical germanium detector for the measurement of 235U activity is 4 Bq, DILs calculated for the lung monitoring were not appropriate. DILs for urine analysis, for which an interval was assumed to be 1 month, were 14.57 ${\mu}g$ $L^{-1}$ based on chemical toxicity after acute inhalation. In addition, acute and chronic inhalation of Type M were calculated 2.85-8.58 ${\mu}g$ $L^{-1}$ and 1.09-3.27 ${\mu}g$ $L^{-1}$ based on the radiological hazard, respectively.

Rapid prenatal diagnosis of chromosome aneuploidies in 943 uncultured amniotic fluid samples by fluorescence in situ hybridization (FISH)

  • Han, Sung-Hee;Kang, Jeom-Soon;An, Jeong-Wook;Lee, An-Na;Yang, Young-Ho;Lee, Kyu-Pum;Lee, Kyoung-Ryul
    • Journal of Genetic Medicine
    • /
    • v.5 no.1
    • /
    • pp.47-54
    • /
    • 2008
  • Purpose : Fluorescence in situ hybridization (FISH) on uncultured amniotic fluid cells offers the opportunity for rapid screening of aneuploidies and has become an integral part of the current practice in many clinical cytogenetics laboratories. Here, we retrospectively analyzed the results of interphase FISH in 943 amniotic fluid samples and assessed the efficiency of FISH for rapid detection of aneuploidies. Methods : Interphase FISH for chromosome 13, 18, and 21 was performed in 943 consecutive amniotic fluid samples for rapid diagnosis of aneuploidies referred from 2004 to 2006. Karyotypes from standard cytogenetic analysis were compared to the FISH results. Results : A total of 45 chromosomal rearrangements (4.8%) were found after conventional cytogenetic analysis of the 943 amniotic fluid. After exclusion of known familiar chromosomal rearrangements and inversions (2.1%, 20/943), 2.7% (25/943) were found to have chromosomal abnormalities. Of this group, 0.7% (6/943) were chromosomal abnormalities not detectable by FISH and 2.0% (19/943) were numerical abnormalities detectable by FISH. All 14 cases of Down syndrome (Classic type, 13 cases; Robertsonian type, 1 case) and 5 cases of trisomy 18 were diagnosed and detected by FISH and there were no false-positive or -negative results (specificity and sensitivity=100%). Conclusion : The present study demonstrates that FISH can provide a rapid and sensitive clinical method for prenatal identification of chromosome aneuploidies. However, careful genetic counseling is essential to explain the limitations of FISH, including the inability to detect all chromosomal abnormalities and the possibilities of uninformative or false-negative results in some cases.

  • PDF

Application of Geophysical Methods to Detection of a Preferred Groundwater Flow Channel at a Pyrite Tailings Dam (황철석 광산 광미댐에서의 지하수흐름 경로탐지를 위한 물리탐사 적용)

  • Hwang, Hak Soo
    • Economic and Environmental Geology
    • /
    • v.30 no.2
    • /
    • pp.137-142
    • /
    • 1997
  • At the tailings dam of the disused Brukunga pyrite mine in South Australia, reaction of groundwater with the tailings causes the formation and discharge of sulphuric acid. There is a need to improve remediation efforts by decreasing groundwater flow through the tailings dam. Geophysical methods have been investigated to determine whether they can be used to characterise variations in depth to watertable and map preferred groundwater flow paths. Three methods were used: transient electromagnetic (TEM) soundings, direct current (DC) soundings and profiling, and self potential (SP) profiling. The profiling methods were used to map the areal extent of a given response, while soundings was used to determine the variation in response with depth. The results of the geophysical surveys show that the voltages measured with SP profiling are small and it is hard to determine any preferred channels of groundwater flow from SP data alone. Results obtained from TEM and DC soundings, show that the DC method is useful for determining layer boundaries at shallow depths (less than about 10 m), while the TEM method can resolve deeper structures. Joint use of TEM and DC data gives a more complete and accurate geoelectric section. The TEM and DC measurements have enabled accurate determination of depth to groundwater. For soundings centred at piezometers, this depth is consistent with the measured watertable level in the corresponding piezometer. A map of the watertable level produced from all the TEM and DC soundings at the site shows that the shallowest level is at a depth of about 1 m, and occurs at the southeast of the site, while the deepest watertable level (about 17 m) occurs at the northwest part of the site. The results indicate that a possible source of groundwater occurs at the southeast area of the dam, and the aquifer thickness varies between 6 and 13 m. A map of the variation of resistivity of the aquifer has also been produced from the TEM and DC data. This map shows that the least resistive (i.e., most conductive) section of the aquifer occurs in the northeast of the site, while the most resistive part of the aquifer occurs in the southeast. These results are interpreted to indicate a source of fresh (resistive) groundwater in the southeast of the site, with a possible further source of conductive groundwater in the northeast.

  • PDF

Eight cases of incidentally diagnosed as subclinical rickets (우연히 발견된 무증상 구루병 8예)

  • Seo, Ji-Young;Kim, Curie;Lee, Hee-Woo;Ahn, Young-Min
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.8
    • /
    • pp.812-819
    • /
    • 2008
  • Purpose : Vitamin D plays a key role in bone mineralization of the skeleton and vitamin D deficiency can lead to rickets. It is well known that vitamin D deficiency is common in breast fed infants. Of these patients, clinically, some have no signs of rickets, but laboratory and radiographic findings are diagnostic for vitamin D deficiency rickets (subclinical vitamin D deficiency rickets). The purpose of this study is to clarify current causes and ways to prevent this disease. Methods : We reviewed the clinical and laboratory characteristics of children who were incidentally diagnosed as subclinical rickets during treatment of other disease such as pneumonia, gastroenteritis, urinary tract infection at Eulji Hospital, Seoul, Korea from March, 2003 to July 2007. Results : Eight patients (six boys and two girls) were diagnosed with subclinical vitamin D deficiency rickets. The mean age of the patients was $12.6{\pm}5.8months$, and they were diagnosed from January to July. The associated diseases were pneumonia, urinary tract infection, acute gastroenteritis, and iron deficiency anemia. All patients were breast-fed. Two showed growth failure. The mean serum alkaline phosphatase was $1995.8{\pm}739.5IU/L$, the mean calcium count was $9.5{\pm}0.6mg/dL$, and the mean phosphorus content was $3.6{\pm}1.5mg/dL$. The mean intact parathyroid hormone was $214.8{\pm}155.9pg/mL$ (reference range, 9-65), the mean 1,25-dihydroxyvitamin D was $82.4{\pm}49.3pg/mL$ (reference range, 2070), and the mean 25-hydroxyvitamin D was $29.6{\pm}10.6ng/mL$ (reference range, 1030). A radiographic examination showed cupping, fraying, and flaring of metaphyses in all patients. Six patients were administered calcitriol (400 IU/day) for three months. A consequent radiographic and laboratory examination showed improvement. The first two patients were initially diagnosed with metaphyseal dysplasia, without the detection of vitamin D deficiency and they spontaneously improved without vitamin D supplements. However, two years later, they showed mild scoliosis and metaphyseal dysplasia, respectively. Conclusion : Breast-feeding without supplementation involves high risk of vitamin D deficiency. Some infants may also develop rickets; therefore, such groups should be considered for vitamin D supplementation.

Dosimetric Characteristics of a Thermal Neutron Beam Facility for Neutron Capture Therapy at HANARO Reactor (하나로 원자로 BNCT 열중성자 조사장치에 대한 선량특성연구)

  • Lee, Dong-Han;Suh, So-Heigh;Ji, Young-Hoon;Choi, Moon-Sik;Park, Jae-Hong;Kim, Kum-Bae;Yoo, Seung-Yul;Kim, Myong-Seop;Lee, Byung-Chul;Chun, Ki-Jung;Cho, Jae-Won;Kim, Mi-Sook
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.87-92
    • /
    • 2007
  • A thermal neutron beam facility utilizing a typical tangential beam port for Neutron Capture Therapy was installed at the HANARO, 30 MW multi-purpose research reactor. Mixed beams with different physical characteristics and relative biological effectiveness would be emitted from the BNCT irradiation facility, so a quantitative analysis of each component of the mixed beams should be performed to determine the accurate delivered dose. Thus, various techniques were applied including the use of activation foils, TLDs and ionization chambers. All the dose measurements were perform ed with the water phantom filled with distilled water. The results of the measurement were compared with MCNP4B calculation. The thermal neutron fluxes were $1.02E9n/cm^2{\cdot}s\;and\;6.07E8n/cm^2{\cdot}s$ at 10 and 20 mm depth respectively, and the fast neutron dose rate was insignificant as 0.11 Gy/hr at 10 mm depth in water The gamma-ray dose rate was 5.10 Gy/hr at 20 mm depth in water Good agreement within 5%, has been obtained between the measured dose and the calculated dose using MCNP for neutron and gamma component and discrepancy with 14% for fast neutron flux Considering the difficulty of neutron detection, the current study support the reliability of these results and confirmed the suitability of the thermal neutron beam as a dosimetric data for BNCT clinical trials.

  • PDF

Improved Device Performance Due to AlxGa1-xAs Barrier in Sub-monolayer Quantum Dot Infrared Photodetector

  • Han, Im Sik;Byun, Young-Jin;Lee, Yong Seok;Noh, Sam Kyu;Kang, Sangwoo;Kim, Jong Su;Kim, Jun Oh;Krishna, Sanjay;Ku, Zahyun;Urbas, Augustine;Lee, Sang Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.298-298
    • /
    • 2014
  • Quantum dot infrared photodetectors (QDIPs) based on Stranski-Krastanov (SK) quantum dots (QDs) have been widely explored for improved device performance using various designs of heterostructures. However, one of the biggest limitations of this approach is the "pancake" shape of the dot, with a base of 20-30 nm and a height of 4-6 nm. This limits the 3D confinement in the quantum dot and reduces the ratio of normal incidence absorption to the off-axis absorption. One of the alternative growth modes to the formation of SK QDs is a sub-monolayer (SML) deposition technique, which can achieve a much higher density, smaller size, better uniformity, and has no wetting layer as compared to the SK growth mode. Due to the advantages of SML-QDs, the SML-QDIP design has attractive features such as increased normal incidence absorption, strong in-plane quantum confinement, and narrow spectral wavelength detection as compared with SK-DWELL. In this study, we report on the improved device performance of InAs/InGaAs SML-QDIP with different composition of $Al_xGa1-_xAs$ barrier. Two SML-QDIPs (x=0.07 for sample A and x=0.20 for sample B) are grown with the 4 stacks 0.3 ML InAs. It is investigated that sample A with a confinement-enhanced (CE) $Al_{0.22}Ga_{0.78}As$ barrier had a single peak at $7.8{\mu}m$ at 77 K. However, sample B with an $Al_{0.20}Ga_{0.80}As$ barrier had three peaks at (${\sim}3.5{\mu}m$, ${\sim}5{\mu}m$, ${\sim}7{\mu}m$) due to various quantum confined transitions. The measured peak responsivities (see Fig) are ~0.45 A/W (sample A, at $7.8{\mu}m$, $V_b=-0.4V$ bias) and ~1.3 A/W (sample B, at $7{\mu}m$, $V_b=-1.5V$ bias). At 77 K, sample A and B had a detectivity of $1.2{\times}10^{11}cm.Hz^{1/2}/W$ ($V_b=-0.4V$ bias) and $5.4{\times}10^{11}cm.Hz^{1/2}/W$ ($V_b=-1.5V$ bias), respectively. It is obvious that the higher $D^*$ of sample B (than sample A) is mainly due to the low dark current and high responsivity.

  • PDF

Prevalence and Clinical Characteristics of Pertussis in Children, Cheonan, Korea (천안지역 소아 백일해 감염의 유병률과 임상적 고찰)

  • Lee, Kun Song;Son, Jae Sung;Chung, Eun Hee;Bae, Hong Ki;Lee, Mee Jeong;Yu, Jeesuk;Chang, Young Pyo;Park, Woo Sung;Kim, Jae Kyoung;Rheem, Insoo;Roh, Eui-Jung
    • Pediatric Infection and Vaccine
    • /
    • v.16 no.2
    • /
    • pp.175-182
    • /
    • 2009
  • Purpose : A number of countries have experienced an increase in pertussis during the past decade. In particular, there has been an increase in the incidence rate among adolescents and adults. To learn more about the current epidemiology of pertussis, we studied the prevalence and clinical characteristics of pertussis in children in Cheonan, South Korea. Methods : We collected nasopharyngeal aspirates of 118 patients who were treated for respiratory symptoms at Dankook Univeristy Hospital between March 2008 and September 2009. We performed multiplex PCR for detection of Bordetella pertussis in those aspirates. Results : Of the 118 patients, 10 (8%) were positive by PCR for B. pertussis. Six episodes occurred during the period July to September 2009. Nine of the 10 patients were less than 3 months old. Seven of them had not received DTaP vaccine. The mean duration of coughing before diagnosis was 10.9${\pm}$5.2 days. Ten patients (100%) had paroxysmal cough and 8 (80%) had post-tussive vomiting. Only one patient had fever. One who had complications that include pneumonia, atelectasis and pneumomediastinum developed an absolute increase in leukocyte count (84,400/$mm^3$). There was a statistically significant relation between vaccine being received and development of complications (P =0.033). Conclusion : We suspect that there was an epidemic of pertussis between July and September 2009. Further investigation by a pediatric or nationwide surveillance system is needed to monitor the changing epidemiology for pertussis.

  • PDF

The Design and Fabrication of Conversion Layer for Application of Direct-Detection Type Flat Panel Detector (직접 검출형 평판 검출기 적용을 위한 변환층 설계 및 제작)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Cho, Chang-Hoon;Heo, Ye-Ji;Yoon, Ju-Seon;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.73-77
    • /
    • 2012
  • Recently, Interest to the photoconductor, which is used to flat form X-ray detector such as a-Se, $HgI_2$, PbO, CdTe, $PbI_2$ etc. is increasing. In this study, the film layer by using the photoconductive material with particle sedimentation was fabricated and evaluated. The quantization efficiency of the continuous X-ray with the 70 kVp energy bandwidth was analyzed by using the Monte Carlo simulation. With the results, the thickness of film with 64 % quantization efficiency was 180 ${\mu}m$ which is similar to the efficiency of 500 ${\mu}m$ a-Se film. And $HIg_2$ film has the high quantization efficiency of 74 % on 240 ${\mu}m$ thickness. The electrical characteristics of the 239 ${\mu}m$ $Hgl_2$ films produced by particle sedimentation were shown as very low dark current(under 10 $pA/mm^2$), and high sensitivity(19.8 mC/mR-sec) with 1 $V/{\mu}m$ input voltage. The SNR, which is influence to the contrast of X-ray image, was shown highly as 3,125 in low driving voltage on 0.8 $V/{\mu}m$. With the results of this study, the development of the low-cost, high-performance image detector with film could be possible by replacing the film produced by particle sedimentation instead to a-Se detector.

A Study on the Legislation for the Commercial and Civil Unmanned Aircraft System Operation (국내 상업용 민간 무인항공기 운용을 위한 법제화 고찰)

  • Kim, Jong-Bok
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.28 no.1
    • /
    • pp.3-54
    • /
    • 2013
  • Nowadays, major advanced countries in aviation technology are putting their effort to develop commercial and civil Unmanned Aircraft System(UAS) due to its highly promising market demand in the future. The market scale of commercial and civil UAS is expected to increase up to approximately 8.8 billon U.S. dollars by the year 2020. The usage of commercial and civil UAS covers various areas such as remote sensing, relaying communications, pollution monitoring, fire detection, aerial reconnaissance and photography, coastline monitoring, traffic monitoring and control, disaster control, search and rescue, etc. With the introduction of UAS, changes need to be made on current Air Traffic Management Systems which are focused mainly manned aircrafts to support the operation of UAS. Accordingly, the legislation for the UAS operation should be followed. Currently, ICAO's Unmanned Aircraft System Study Group(UASSG) is leading the standardization process of legislation for UAS operation internationally. However, some advanced countries such as United States, United Kingdom, Australia have adopted its own legislation. Among these countries, United States is most forth going with President Obama signing a bill to integrate UAS into U.S. national airspace by 2015. In case of Korea, legislation for the unmanned aircraft system is just in the beginning stage. There are no regulations regarding the operation of unmanned aircraft in Korea's domestic aviation law except some clauses regarding definition and permission of the unmanned aircraft flight. However, the unmanned aircrafts are currently being used in military and under development for commercial use. In addition, the Ministry of Land, Infrastructure and Transport has a ambitious plan to develop commercial and civil UAS as Korea's most competitive area in aircraft production and export. Thus, Korea is in need of the legislation for the UAS operation domestically. In this regards, I personally think that Korea's domestic legislation for UAS operation will be enacted focusing on following 12 areas : (1)use of airspace, (2)licenses of personnel, (3)certification of airworthiness, (4)definition, (5)classification, (6)equipments and documents, (7)communication, (8)rules of air, (9)training, (10)security, (11)insurance, (12)others. Im parallel with enacting domestic legislation, korea should contribute to the development of international standards for UAS operation by actively participating ICAO's UASSG.

  • PDF