• 제목/요약/키워드: Current density

검색결과 5,647건 처리시간 0.036초

미세 펄스전원을 이용한 스테인레스강의 전기화학연마 (Study on Electrochemical Polishing for Stainless Steel using Micro Pulse Current)

  • 이동활;박정우;문영훈
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 춘계학술대회논문집
    • /
    • pp.127-130
    • /
    • 2003
  • Electrolytic polishing is the anodic dissolution process in the transpassive state. It removes non-metallic inclusions and improves mechanical and corrosion resistance of stainless steel. Electrolytic polishing is normally used to remove a very thin layer of material from the surface of a metal object. An electrolyte of phosphoric, sulfuric and distilled water has been used in this study. In the low current density region, there can be found plateau region and material removal process and leveling process occur successively. In this study, an electrochemical polishing process using pulse current is adopted as a new electrochemical polishing process. In electrochemical machining processes, it has been found that pulse electrochemical processes provide an attractive alternative to the electrochemical processes using continuous current. Hence, this study will discuss the electrochemical polishing processes in low current density region and pulse electrochemical polishing.

  • PDF

전력기기에서 $100 A/mm^2$급 Bi-2223테이프 ($100 A/mm^2$ Class Bi-2223 Tapes in Electromechanical Devices)

  • 류경우;최경주;성기철;류강식
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.55-60
    • /
    • 2002
  • $100 A/mm^2$ class Bi-2223 tapes have recently become commercially available. Some important characteristics of the tapes, e .g. critical current, ac loss, characteristics at joint, fault current characteristics, are required for an application such as a power cable or a power transformer. In this paper they have been investigated experimentally. The results indicate that the self-field loss of the high current density tapes is not negligible, compared to resistive loss in a copper wire for the same currents. In a cable, the self-field loss for relatively large currents is much larger than the magnetization loss due to an external field. But in a transformer, the magnetization loss is dominant, compared to the self-field loss. Finally the fault current characteristics show that the high current density tapes are never safe from burn-out even for fault currents with a few cycles.

자기공명촬영상에서 구한 내부 전류밀도를 이용한 임피던스 단층촬영법 (Impedance Tomography using Internal Current Density Distribution Measured by Nuclear Magnetic Resonance)

  • 이수열;우응제;문치웅
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권4호
    • /
    • pp.413-418
    • /
    • 1994
  • In electrical impedance tomography (EIT), we use boundary current and voltage measurements to provide the information about the cross-sectional distribution of electrical impedance or resistivity One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.7T NMR machine. We implemented a resistivity image reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the image reconstruction algorithm and furture direction of the research.

  • PDF

AlGaAs/GaAs HBTs의 에미터 크기에 따른 전류 이득 변화에 관한 연구 (A Study on the Current Gain Variation with the Emitter Size in AlGaAs/GaAs HBTs)

  • 정준오;이헌용;이태우;김일호;박문평;박성호;편광의
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.10-12
    • /
    • 1996
  • AlGaAs/GaAs Heterojunotion Bipolar Transistors (HBTs) with various emitter areas were fabricated and the device size dependence on the current gain was examined. With the different emitter areas, the passivated devices having the same peripheral length were fabricated and measured. The measured base current density in the Gummel plots shows an ideality factor of nearly 2. It is found that as the emitter area becomes small, the base current density with the ideality factor of 2 increases linearly, and as the emitter perimeter/area ratio becomes large, the surface recombination current density component increases. The current gain performance in AlGaAs/GaAs HBTs is mainly determined by either the larger emitter area or the smaller ratio of the emitter perimeter to the emitter area. These results will be compared with experimental works for GaInP/GaAs HBTs

  • PDF

미세 펄스전원을 이용한 스테인레스강 300 계열의 전기화학연마 (Study on Electrochemical Polishing for Stainless Steel 300 Series using Micro Pulse Current)

  • 이동활;박정우;문영훈
    • 소성∙가공
    • /
    • 제12권4호
    • /
    • pp.388-393
    • /
    • 2003
  • Electrolytic polishing is the anodic dissolution process in the transpassive state. It removes non-metallic inclusions and improves mechanical and corrosion resistance of stainless steel. Electrolytic polishing is normally used to remove a very thin layer of material from the surface of a metal object. An electrolyte of phosphoric acid 50% in vol., sulfuric acid 20% in vol. and distilled water 30% in vol. has been used in this study. In the low current density region, there can be found plateau region and material removal process and leveling process occur successively. In this study, an electrochemical polishing process using pulse current is adopted as a new electrochemical polishing process. In electrochemical machining processes, it has been found that pulse electrochemical processes provide an attractive alternative to the electrochemical processes using continuous current. Hence, this study will discuss the electrochemical polishing processes in low current density region and pulse electrochemical polishing.

3가 크롬도금의 전착속도 및 표면형상에 미치는 첨가제의 영향 (The Effect of Additives on the Deposition Rate and the Surface Morphology of Trivalent Chromium Electrodeposits)

  • 예길촌;서경훈
    • 한국표면공학회지
    • /
    • 제37권1호
    • /
    • pp.13-21
    • /
    • 2004
  • The deposition rate, the current efficiency and surface morphology of trivalent Cr deposits were investigated according to additives in sulfate bath and current density. The deposition rate of the Cr deposits plated from the formic acid complexed bath was noticeably higher than that of the glycine complexed bath. The current efficiency of the deposition from formic acid bath was higher than that of the glycine bath and increased with current density in the range of 20-50 A/d$\m^2$. The current efficiency of the deposition from the formic acid bath with boric acid buffer was higher than that of the bath with aluminum sulfate or boric acid-aluminum sulfate buffers. The nodular crystallite size of the Cr deposits increased with current density and the uniform and crack-free growth of the deposits for the aluminum sulfate was observed compared to the other buffers.

영일만내의 유동과 수질특성에 관한 연구 (Study on Current and Water Quality Characteristics in Yongil Bay)

  • 김헌덕;김종인;류청로
    • 한국해양공학회지
    • /
    • 제15권4호
    • /
    • pp.28-37
    • /
    • 2001
  • The water quality in Yongil Bay is getting worse due to the sewage and the waste water from the surrounding industrial complex. The study aims to simulate the current system that is necessary to build ecosystem model for the optium water quality control and clarify the correlation of current system characteristics with water quality in Yongil Bay. To clarify the characteristics of coastal water movement system and verify the applicability of the 3-D model, the current system was simulated using 3-D model baroclinic model which considers tidal current and density effects. As the results of numerical experiments, it is proved the 3-D model is the most applicable on appearing the current system of the stratificated Yongil Bay difference of density. Form the results of simulation considered tidal current only, it can be clarified that the water body flows in the inner bay through the bottom layer and flows out the outer bay through the surface layer in Yongil Bay. And the fresh water from the Hyongsan river and the thermal discharge form POSCO have a little effect on the current system in Yongil Bay, but the diffusion of heat and salt has an important effect upon the formation of the density stratification of the water quality distribution is closely related with the current structure characteristics as well as the tidal residual current system in Yongil Bay.

  • PDF

Residual magnetic field profiles and their current density profiles of coated conductors for fast and slow cut-off current operations

  • Sun, J.;Tallouli, M.;Shyshkin, O.;Hamabe, M.;Watanabe, H.;Chikumoto, N.;Yamaguchi, S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권1호
    • /
    • pp.17-20
    • /
    • 2015
  • Coated conductor is an important candidate for power cable applications due to its high current density. Even for DC power cable transmission, we must study the transport properties of HTS tapes after slow and fast discharge. In order to evaluate relation of the magnetic field with applied current we developed a scanning magnetic field measurements system by employing a Hall probe. This work presents the measurements of the magnetic fields above a coated conductor by varying applied current pattern. In the work, a transport current of 100 A, less than the critical current, is applied to YBCO coated conductor. We measured the residual magnetic field distributions after cut off the transport current with slow and fast operations. The results show differences of the magnetic field profiles and the corresponding current profiles by an inverse solution from the magnetic field measurement between these two operations because of the hysteresis of coated conductor excited by the transport current.

시스템다이내믹스를 활용한 도시개발밀도의 적정성 평가 모델 구축 연구 (Establishment of the Measurement Model about the Adequate Urban Development Density using System Dynamics)

  • 전유신;문태훈
    • 한국시스템다이내믹스학회:학술대회논문집
    • /
    • 한국시스템다이내믹스학회 2003년도 하계학술대회발표논문집
    • /
    • pp.1-24
    • /
    • 2003
  • The purpose of this paper was developing a development density control model for urban growth management, using system dynamics modeling. The density control model was developed to see how urban growth, transition, and decay occur depending on the interaction among population, houses, industry structure, land and urban infrastructure such as road, water supply, and sewage treatment facilities. Suggesting adequate level of development density control using the model was another purpose of this paper. The model was applied to An'yang city to estimate the maximum number of population, industry structures, houses, and cars that can be adequately sustained with the current An'yang city's infrastructur capacity. The computer simulation results shows that the city is overpopulated by some 90,000 people. To reduce the population to the adequate level that the current urban infrastructure can sustain, the current city regulation on floor area ratio are needed to be strengthened at least 20 to 35%.

  • PDF