• 제목/요약/키워드: Current decomposition

검색결과 280건 처리시간 0.023초

전자빔 용접에서 SVD을 이용한 온라인 모니터링 (On-line Monitoring Using SVD in a Electron Beam Welding)

    • Journal of Welding and Joining
    • /
    • 제18권1호
    • /
    • pp.97-103
    • /
    • 2000
  • Time series analysis results show the SVD is a candidate of on-line monitoring of welding penetration when the covariance matrix of a full penetration is used as a mapping function. As the reconstructed embedding vectors from the chaotic scalar time series are manipulated by the covariance matrix, the mapped tim series lie on a hyper-ellipsoid which the lengths of semi-axes are the squared eigenvalues of the covariance matrix in the case of full penetration. These visualize by two dimensional stroboscope views. The other cases like partial penetration, are different in the sense of sizes and shapes. Here we test two types of time series; the ion current and the X-ray. The ion current is better than the X-ray as an on-line monitoring signal, because the difference of the eigenvalue spectrum of the ion(between the pull penetration and partial penetration) is bigger than those of the X-ray.

  • PDF

Fullerene과 Polyaniline을 이용한 유기 Peltier소자의 개발 (Preparation of Organic Peltier using Fullerene/Polyaniline)

  • 이채정;김주용
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.343-345
    • /
    • 2007
  • Temperature difference between two plates occurs when a current is passed though two semi-conductors that are connected each other at two junctions. The current drives a transfer of heat from one junction to the other. In this study, the thermoelectric module based on th "Peltier effect" was made by combing fullerene and polyaniline. Continuous temperature measurements on both surfaces were performed at room temperature($25.4^{\circ}C$) by an infrared non-contact thermometer. The results showed that cool ing effect of $2.2^{\circ}C$ was attained by 30 seconds, after which the effect was continuously vanished mainly due to electro decomposition.

  • PDF

On Electric Field Induced Processes in Ionic Compounds

  • Schmalzried, H.
    • 한국세라믹학회지
    • /
    • 제38권6호
    • /
    • pp.499-505
    • /
    • 2001
  • The behaviour of ionic compound crystals under combined chemical and externally applied electrical potential gradients is discussed. Firstly, a systematic overview is given. Then a formal analysis follows. The transport equations of the ions and the electric defects predict that even with reversible electrodes demixing, and in particular decomposition of the compound will occur if the applied d.c. current density is sufficiently high. These predictions are illustrated by appropriate experiments. With the help of the solid solution (Me, Fe)O, where Fe-ions are the dilute species, we investigate experimentally the behaviour of a ternary ionic crystal under a d.c. electric current load. All the compounds were placed in a galvanic cell, and the internal reactions which then could be observed were driven by the electric field in this cell. In addition, we discuss the influence of the electric field on the classical solid state reaction AX+BX=ABX$_2$, if again the reaction couple is placed in a galvanic cell.

  • PDF

커뮤니티 활성화를 위한 사이버 아파트 구축 현황에 관한 연구 (A Study on the Current Trends of Cyber Apartment for Vitalizing Communities)

  • 성문희;최진원
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2003년도 정기총회 및 추계학술대회
    • /
    • pp.109-114
    • /
    • 2003
  • Fast economic growth resulted in fast industrialization and metropolitanization. At that time, housing was supplied in large quantity, and the apartment became a dominant type of housing in Korea It is partly due to the high population density. But, large quantity supply of apartments caused a lot of problems. One of the biggest problems is decomposition of traditional communities. As interest about quality of life grows since the 90's, the recovery of communities is getting an import assignment that should be solved. Architects investigate ways of arrangement and community facilities planning. off-line Communities might be substituted by or supported with cyber communities through the use of IT technology. The construction of cyber apartment is getting popular by the governmental incentive in 1999. At first, the infrastructure has been constructed, and then the current emphasis in on forming the information community to provide various service.

  • PDF

열교환기 전열관의 결함에 대한 와전류 탐상 수치해석방법 (Numerical Analysis Methods for Eddy Current Testing for Heat Exchanger Tube with Axi-symmetric Defects)

  • 김창욱;서장원;김신;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.831-833
    • /
    • 2000
  • In this paper, a numerical analysis algorithm of eddy current testing(ECT) for heat exchanger tube with axi-symmetric defects using finite element method(FEM) is presented. In the ECT FEM analysis, we used trianglular and rectangular elements for exact signal of ECT for variable shape of defects. This paper presents a systematic and efficient numerical analysis algorithm for ECT. We employ the LU decomposition and Cholesky method for solving the system matrix. This numerical analysis algorithm is effectively applied to heat exchanger tube with defects.

  • PDF

An Improved Control Strategy Using a PI-Resonant Controller for an Unbalanced Stand-Alone Doubly-Fed Induction Generator

  • Phan, Van-Tung;Lee, Hong-Hee;Chun, Tae-Won
    • Journal of Power Electronics
    • /
    • 제10권2호
    • /
    • pp.194-202
    • /
    • 2010
  • The main cause of degradation in an unbalanced stand-alone doubly-fed induction generator (DFIG) system is negative sequence components that exist in the generated stator voltages. To eliminate these components, a hybrid current controller composed of a proportional-integral controller and a resonant regulator is developed in this paper. The proposed controller is applied to the rotor-side converter of a DFIG system for the purpose of compensating the negative stator voltage sequences. The proposed current controller is implemented in a single positive rotating reference frame and therefore the controller can directly regulate both the positive and negative sequence components without the need for sequential decomposition of the measured rotor currents. In terms of compensation capability and accuracy, simulations and experimental results demonstrated the excellent performance of the proposed control method when compared to conventional vector control schemes.

Unsteady wind loading on a wall

  • Baker, C.J.
    • Wind and Structures
    • /
    • 제4권5호
    • /
    • pp.413-440
    • /
    • 2001
  • This paper presents an extensive analysis of unsteady wind loading data on a 18 m long and 2 m high wall in a rural environment, with the wind at a range of angles to the wall normal. The data is firstly analyzed using standard statistical techniques (moments of probability distributions, auto- and cross-correlations, auto- and cross-spectra etc.). The analysis is taken further using a variety of less conventional methods - conditional sampling, proper orthogonal decomposition and wavelet analysis. It is shown that, even though the geometry is simple, the nature of the unsteady flow is surprisingly complex. The fluctuating pressures on the front face of the wall are to a great extent caused by the turbulent fluctuations in the upstream flow, and reflect the oncoming flow structures. The results further suggest that there are distinct structures in the oncoming flow with a variety of scales, and that the second order quasi-steady approach can predict the pressure fluctuations quite well. The fluctuating pressures on the rear face are also influenced by the fluctuations in the oncoming turbulence, but also by unsteady fluctuations due to wake unsteadiness. These fluctuations have a greater temporal and spatial coherence than on the front face and the quasi-steady method over-predicts the extent of these fluctuations. Finally the results are used to check some assumptions made in the current UK wind loading code of practice.

전기 임피던스 단층촬영법에서 TSVD 기반의 역문제 해법의 개발 (Development of Inverse Solver based on TSVD in Electrical Impedance Tomography)

  • 김봉석;김창일;김경연
    • 전자공학회논문지
    • /
    • 제54권4호
    • /
    • pp.91-98
    • /
    • 2017
  • 전기 임피던스 단층촬영 기법은 도메인의 표면에 부착된 전극들을 통해 주입된 전류와 측정된 전압 데이터를 기반으로, 미지의 도전율 분포를 복원하는 비파괴 기술이다. 이 논문에서는 전기 임피던스 단층촬영법에서 일반적 Tikhonov 조정을 갖는 역문제를 풀고 도전율 분포를 복원하기 위해 절단된 특이값 분해 기반의 역문제 해법을 제안하였다. 역문제 계산시간을 줄이기 위해 일반 조정행렬을 역행렬 항목에서 분리시키고 절단된 특이값 분해 방법을 적용하였다. 제안한 방법의 성능을 검증하기 위해 모의실험과 팬텀실험을 수행하고 복원결과를 비교하였다.

Elimination of environmental temperature effect from the variation of stay cable force based on simple temperature measurements

  • Chen, Chien-Chou;Wu, Wen-Hwa;Liu, Chun-Yan;Lai, Gwolong
    • Smart Structures and Systems
    • /
    • 제19권2호
    • /
    • pp.137-149
    • /
    • 2017
  • Under the interference of the temperature effect, the alternation of cable force due to damages of a cable-stayed bridge could be difficult to distinguish. Considering the convenience and applicability in engineering practice, simple air or cable temperature measurements are adopted in the current study for the exclusion of temperature effect from the variation of cable force. Using the data collected from Ai-Lan Bridge located in central Taiwan, this work applies the ensemble empirical mode decomposition to process the time histories of cable force, air temperature, and cable temperature. It is evidently observed that the cable force and both types of temperature can all be categorized as the daily variation, long-term variation, and high-frequency noise in the order of decreasing weight. Moreover, the correlation analysis conducted for the decomposed variations of all these three quantities undoubtedly indicates that the daily and long-term variations with different time shifts have to be distinguished for accurately evaluating the temperature effect on the variation of cable force. Finally, consistent results in reducing the range of cable force variation after the elimination of temperature effect confirm the validity and stability of the developed method.

A hybrid structural health monitoring technique for detection of subtle structural damage

  • Krishansamy, Lakshmi;Arumulla, Rama Mohan Rao
    • Smart Structures and Systems
    • /
    • 제22권5호
    • /
    • pp.587-609
    • /
    • 2018
  • There is greater significance in identifying the incipient damages in structures at the time of their initiation as timely rectification of these minor incipient cracks can save huge maintenance cost. However, the change in the global dynamic characteristics of a structure due to these subtle damages are insignificant enough to detect using the majority of the current damage diagnostic techniques. Keeping this in view, we propose a hybrid damage diagnostic technique for detection of minor incipient damages in the structures. In the proposed automated hybrid algorithm, the raw dynamic signatures obtained from the structure are decomposed to uni-modal signals and the dynamic signature are reconstructed by identifying and combining only the uni-modal signals altered by the minor incipient damage. We use these reconstructed signals for damage diagnostics using ARMAX model. Numerical simulation studies are carried out to investigate and evaluate the proposed hybrid damage diagnostic algorithm and their capability in identifying minor/incipient damage with noisy measurements. Finally, experimental studies on a beam are also presented to compliment the numerical simulations in order to demonstrate the practical application of the proposed algorithm.