POWER FACTOR CORRECTION OF CO2 WELDING MACHINE USING SINGLE-SWITCH THREE-PHASE AC/DC CONVERTER

  • Kim, Jse-Mun;Kim, Yuen-Chung;Ahn, Jung-Jun;Won, Chung-Yuen;Kim, Sei-Chan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.663-667
    • /
    • 1998
  • This paper describes for reducing harmonic distortion on CO2 welding machine with nonlinear load characteristic using single-switch three-phase AC/DC converter. The low-order harmonic component amplitude of the phase current of single-switch three-phase discontinuous mode is calculated. Experimental results show that CO2 welding machine with single-switch three-phase AC/DC converter is effectively controlled with power factor correction for phase current during welding time.

  • PDF

역률개선을 위한 자기에너지 궤환기법의 단일전력단 AC/DC 컨버터의 해석 및 구현 (Analysis and Implementation of Single-Stage AC/DC Converter with Magnetic Energy Feedback Technique for Power Factor Correction)

  • 문건우;오관일;전영수
    • 전력전자학회논문지
    • /
    • 제3권2호
    • /
    • pp.148-155
    • /
    • 1998
  • 역률개선을 위한 변압기 자기에너지 궤환 기법을 이용한 새로운 단일 전력단, 단일 스위치 방식의 AC/DC 컨버터를 제안한다. 제안한 컨버터의 동작원리 및 해석을 수행하였다. 제안한 컨버터는 선전류 고조파 왜곡이 작으며 고역률 및 정확한 전압 조정이 가능하다. 실험모델은 단일 역률에 가까운 역률을 보이며 IEC 555-2를 충분히 만족시킨다.

A New High Power Factor ZVT-ZCT AC-DC Boost Converter

  • Ting, Naim Suleyman
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1539-1548
    • /
    • 2018
  • This paper introduces a new soft switched AC-DC boost converter with power factor correction (PFC). In the introduced converter, all devices are turned on and off under soft switching (SS). The main switch is turned on under zero voltage transition (ZVT) and turned off under zero current transition (ZCT). The main diode is turned on under zero voltage switching (ZVS) and turned off under zero current switching (ZCS). Meanwhile, there is not any current or voltage stress on the main devices. Besides, the auxiliary switch is turned on under ZCS and turned off under ZVS. The detailed theoretical analysis of the converter is presented, and also theoretical analysis is verified by a prototype with 100 kHz and 500 W. Also, the proposed converter has 99.8% power factor and 97.5% total efficiency at soft switching operation.

Inverter Air-conditioner Power System with Low Power Dissipation Type using Micro-controller

  • Mun, Sang-Pil;Shu, Ki-Young;Kim, Ju-Yong;Kim, Kwang-Tae
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.492-496
    • /
    • 2004
  • When using a conventional power factor correction circuit, a comparatively huge capacitor is used to boost-up output voltage. It has a large amount of harmonic distortion in the input current waveform. To improve the input current waveform of diode rectifiers, we propose a new operating principle for the power factor correction circuit. Due to the fact that the proposed circuit uses smaller ones and a smaller reactor, the output voltage increases and obtains higher input current waveforms. These are suitable for the harmonics guidelines. The proposed circuit is able to obtain higher power factor and efficiency. Also, it has reduced switching loss and held over-shooting by using an inverter of eliminated dead-time HPWM that has non-linear impedance circuits to make up diodes, capacitance and a reactor. We compared the conventional PWM inverter and proposed HPWM inverters and found that a high input power factor of 97[%] and an efficiency of 98[%] were also obtained.

  • PDF

인버터에어컨에 능동역률개선회로 적용에 관한 연구 (A Study On The Application Of Active Power Factor Correction Circuit In Inverter Airconditioner)

  • 김태덕;배영돈;박윤서
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.306-308
    • /
    • 1996
  • The demands of minimizing the reactive power and reducing the current harmonics are increasing nowdays. The inverter airconditioner needs high inductive power and it operates with wide load ranges. Conventionally, an huge LC passive filter is used in airconditioner to improve the power factor and to reduce current harmonics which doesn't give good results. In this paper, a design of active power factor correction(APFC)circuit for inverter airconditioner is described. To improve the P.F and reduce the current THD, average current controlled APFC is designed and tested. The problems of APFC implementation, their solution and testing results are described.

  • PDF

가변 이득을 가지는 단상 PFC 디지털 제어기 (The Digital Controller of the Single-Phas Power Factor Correction(PFC) having the Variable Gain)

  • 정창용
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.163-167
    • /
    • 2000
  • This paper presents the digital control of single-phase power factor correction(PFC) converter which has the variable gain according to the condition of inner control loop error. Generally the gain of inner current control loop in single-stage PFC converter has a constant magnitude. This has a bad influence on the power factor because current loop doesn't operate smoothly in the condition that input voltage is low In particular a digital controller has more time delay than an analog controller and degrades This drops the phase margin of the total digital PFC system,. It causes the problem that the gain of current control loop isn't increased enough. In addition the oscillation happens in the peak value of the input voltage open loop PFC system gain changes according to ac input voltage. These aspects make the design of the digital PFC controller difficult The digital PFC controller presented in this paper has a variable gain of current control loop according to input voltage. The 1kW converter was used to verify the efficiency of the digital PFC controller.

  • PDF

A New Single-Stage Small Power MH lamp Electronic Ballast

  • Zhang, Xiaoqiang;Zhang, Weiping;Zhang, Mao
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권2호
    • /
    • pp.79-85
    • /
    • 2016
  • In this study, we proposed a new single-stage small power MH lamp electronic ballast and power-factor correction circuit with improved circuit by the current of passive power factor correction. Main circuit integrates traditional DC/DC and DC/AC circuits into one-stage DC/AC inverter. Moreover, we described the working principle and control strategy of the new circuit; it's soft switching principle; and resonant element parameter design formula. An experimental prototype of HID lamp electronic ballast with output power of 70 W was built to verify the feasibility of the analysis and design. The simulation and experimental results proved that the power factor of this circuit could reach 94%, with efficiency of 90%. The input current harmonics conform to IEC 61000-3-2 standards and its cost is low. These superior performances of the new circuit indicate certain practical values.

우수한 공통 모드 노이즈 특성을 가진 브릿지 다이오드가 없는 고효율 PFC 컨버터 (High Efficiency Bridgeless Power Factor Correction Converter With Improved Common Mode Noise Characteristics)

  • 장효서;이주영;김문영;강정일;한상규
    • 전력전자학회논문지
    • /
    • 제27권2호
    • /
    • pp.85-91
    • /
    • 2022
  • This study proposes a high efficiency bridgeless Power Factor Correction (PFC) converter with improved common mode noise characteristics. Conventional PFC has limitations due to low efficiency and enlarged heat sink from considerable conduction loss of bridge diode. By applying a Common Mode (CM) coupled inductor, the proposed bridgeless PFC converter generates less conduction loss as only a small magnetizing current of the CM coupled inductor flows through the input diode, thereby reducing or removing heat sink. The input diode is alternately conducted every half cycle of 60 Hz AC input voltage while a negative node of AC input voltage is always connected to the ground, thus improving common mode noise characteristics. With the aim to improve switching loss and reverse recovery of output diode, the proposed circuit employs Critical Conduction Mode (CrM) operation and it features a simple Zero Current Detection (ZCD) circuit for the CrM. In addition, the input current sensing is possible with the shunt resistor instead of the expensive current sensor. Experimental results through 480 W prototype are presented to verify the validity of the proposed circuit.

전기차 배터리 충전기용 강인한 단위 입력 역률 제어장치 (Robust and Unity Input Power Factor Control Scheme for Electric Vehicle Battery Charger)

  • 웬콩롱;이홍희
    • 전력전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.182-192
    • /
    • 2015
  • This study develops a digital control scheme with power factor correction for a front-end converter in an electric vehicle battery charger. The front-end converter acts as the boost-type switching-mode rectifier. The converter assumes the two roles of the battery charger, which include power factor control and robust charging performance. The proposed control scheme consists of a charging control algorithm and a grid current control algorithm. The scheme aims to obtain unity input power factor and robust performance. Based on the linear average model of the converter, a constant-current constant-voltage charging control algorithm that passes through only one proportional-integral controller and a current feed-forward path is proposed. In the current control algorithm, we utilized a second band pass filter, a single-phase phase-locked loop technique, and a duty-ratio feed-forward term to control the grid current to be in phase with the grid voltage and achieve pure sinusoidal waveform. Simulations and experiments were conducted to verify the effectiveness of the proposed control scheme, both simulations and experiments.

변압기 자화 에너지를 이용한 새로운 단일전력단 고역률 컨버터 (New Single-Stage High Power Converter Using Transformer Magnetizing Energy)

  • 문건우;노정욱;정영석;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.35-38
    • /
    • 1996
  • A new high power factor converter using transformer magnetizing energy for power factor correction with a single-switch/single-stage is proposed. The proposed converter gives the good power factor correction, low current harmonic distortions, and tight output voltage regulation. The prototype shows the IEC555-2 requirements are met satisfactorily with nearly unity power factor.

  • PDF