• Title/Summary/Keyword: Current compensator

Search Result 235, Processing Time 0.026 seconds

Improvement of line Current using Instantaneous Real Power Compensation of DSTATCOM (DSTATCOM의 순시 유효전력 보상을 이용한 선로의 전류 개선)

  • Jeong, Su-Yeong;Kim, Tae-Hyeon;Mun, Seung-Il;Gwon, Uk-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.7
    • /
    • pp.327-332
    • /
    • 2002
  • In this paper, conventional reactive power compensation is defined and instantaneous real control concept for shunt converters is proposed. This equipment incorporates the compensation function of harmonics at the distribution line by nonlinear load. These methodologies are applied to IEEE 13 distribution system with the modeling of nonlinear load using EMTEDC/PSCAD package. Simulation with EMTDC results presented to confirm that the new approach has better performance than those obtained by controllers based on traditional concepts of reactive power compensation.

Zero Power Levitation Control with Gap Compensator of Hybrid Magnet Levitation by Load Observer (부하 관측기에 의한 공극 보상기를 포함한 제로파워 부상제어)

  • Kim, Kwang-Min;Kim, Youn-Hyun;Chun, Yon-Do;Lee, Ju;Kim, Hak-Ryeon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.669-671
    • /
    • 2000
  • This paper introduced the scheme that it improved performance of magnetic levitation system with zero power controller. Magnetic levitation is used widely, but it is complicated and difficult to control due to having nonlinear characteristics of gap and current. So, it is proposed a scheme considered changed gap according to variable load and is verified by simulation and experiments in this paper.

  • PDF

Path Tracking Control for Mobile Robot Considering Its Dynamics (동특성을 고려한 이동로봇의 궤적제어)

  • Ko, Kyung-Suk;Lee, Min-Jung;Choi, Young-Kiu
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2473-2475
    • /
    • 2001
  • In trajectory tracking methods, the error values of current position and velocity are compensated to follow the given reference path and velocity. The path tracking for a wheeled mobile robot is treated in this paper. It is very difficult to implement stable trajectory tracking algorithms because mobile robots have kinematically non-holonomic constraints. For solving this problem, a velocity controller is presented in this paper. This velocity controller is designed by a PID controller which could be easily employed. In this case, velocity errors caused by system uncertainties or internal and external disturbances could exist. A neural network is used for compensating the velocity errors. Input variables of this neural network compensator are defined by differences between the velocities of the posture controller and the real velocities of the mobile robot. Simulation results show the effectiveness of the proposed controller.

  • PDF

A Simple Grid-Voltage-Sensorless Control Scheme for PFC Boost Converters

  • Nguyen, Cong-Long;Lee, Hong-Hee;Chun, Tae-Won
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.712-721
    • /
    • 2014
  • This paper introduces a simple grid-voltage-sensorless control scheme for single-phase power factor correction (PFC) boost converters. The grid voltage waveform is obtained based on the dc output voltage, the switching duty ratio, and a phase-lead compensator. In addition, the duty ratio feedback is utilized to obtain the unity input power factor and the zero harmonic current. The proposed control scheme is designed and mathematically analyzed based on a small-signal model of PFC boost converters. To verify the effectiveness of the proposed control scheme, several simulations and experiments are carried out in two applications: an industrial power system with a 60 Hz grid frequency and a commercial aircraft application with a 400 Hz grid frequency.

System-Level Vulnerability Analysis for Commutation Failure Mitigation in Multi-infeed HVDC Systems

  • Yoon, Minhan;Jang, Gilsoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1052-1059
    • /
    • 2018
  • This paper deals with commutation failure of the line-commutated converter high voltage direct current (LCC HVDC) system caused by a three phase fault in the ac power system. An analytic calculation method is proposed to estimate the maximum permissible voltage drop at the LCC HVDC station on various operating point and to assess the area of vulnerability for commutation failure (AOV-CF) in the power system based on the residual phase voltage equation. The concept is extended to multi-infeed HVDC power system as the area of severity for simultaneous commutation failure (AOS-CF). In addition, this paper presents the implementation of a shunt compensator applying to the proposed method. An analysis and simulation have been performed with the IEEE 57 bus sample power system and the Jeju island power system in Korea.

An Improved Control Approach for DSTATCOM with Distorted and Unbalanced AC Mains

  • Singh, Bhim;Solanki, Jitendra
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.131-140
    • /
    • 2008
  • This paper presents a new control approach of DSTATCOM (distribution static compensator) for compensation of reactive power, unbalanced loading and harmonic currents under unbalanced non-sinusoidal ac mains. The control of DSTATCOM is achieved using Adaline based current estimator based on LMS algorithm to maintain source currents real and undistorted. The dc bus voltage of voltage source converter (VSC) working as DSTATCOM is maintained at constant voltage using a proportional-integral (PI) controller. The DSTATCOM system alongwith proposed control scheme is modeled in MATLAB to simulate the behavior of the system. The practical implementation of the DSTATCOM is carried out using dSPACE DS1104 R&D controller having TMS320F240 as a slave DSP. Simulated and implementation results are presented to demonstrate the effectiveness of the DSTATCOM with Adaline based control to meet the severe load perturbations with different types of loads (linear and non-linear) under distorted and unbalanced AC mains.

Study for the selection of the optimal placement for STATCOM, using IPLAN (IPLAN을 이용한 STATCOM의 최적위치선정에 관한 연구)

  • Kim Won Kyu;Gu Min Yan;Baek Young Sik
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.171-173
    • /
    • 2004
  • This paper presents the selection of optimal placement for STATCOM (Static synchronous Compensator) which is one of the FACTS (Flexible Alternating Current Transmission System) devices, considering line contingency. Line contingency ranking is gotten by using sensitivity of load margin. According to line contingency ranking line contingency was considered. And IOP (Index for selecting optimal Placement of STATCOM) is calculated by the variation of each bus's reactive mum for several line contingencies. The bus where has the biggest value of lOP is the most optimal placement to install STATCOM for voltage stability. IPLAN is used to program this part which get IOP. This study is carried out on the modified IEEE14 Bus Test System to confirm the efficiency of the method.

  • PDF

A Study on a Current Control Based on Model Prediction for AC Electric Railway Inbalance Compensation Device (교류전력 불평형 보상장치용 모델예측기반 전류제어 연구)

  • Lee, Jeonghyeon;Jo, Jongmin;Shin, Changhoon;Lee, Taehoon;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.6
    • /
    • pp.490-495
    • /
    • 2020
  • The power loss of large-capacity systems using single-phase inverters has attracted considerable attention. In this study, optimal switching sequence model prediction control at a low switching frequency is proposed to reduce the power loss in a high-power inverter system, and a compensation method that can be utilized for model prediction control is developed to reduce errors in accordance with sampling values. When a three-level, single-phase inverter using a switching frequency of 600 Hz and a sampling frequency of 12 kHz is adopted, the power factor is improved from 0.95 to 0.99 through 3 kW active power control. The performance of the controller is also verified.

Design of an 8× Four-group Zoom System without a Moving Group by Considering the Overall Length

  • Park, Sung Min;Lee, Jea-Woo;Park, Sung-Chan
    • Current Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.104-113
    • /
    • 2022
  • We present a method to count the overall length of the zoom system in an initial design stage. In a zoom-lens design using the concept of the group, it has been very hard to precisely estimate the overall length at all zoom positions through the previous paraxial studies. To solve this difficulty, we introduce Teq as a measure of the total track length in an equivalent zoom system, which can be found from the first order parameters obtained by solving the zoom equations. Among many solutions, the parameters that provide the smallest Teq are selected to construct a compact initial zoom system. Also, to obtain an 8× four-group zoom system without moving groups, tunable polymer lenses (TPLs) have been introduced as a variator and a compensator. The final designed zoom lens has a short overall length of 29.99 mm, even over a wide focal-length range of 4-31 mm, and an f-number of F/3.5 at wide to F/4.5 at tele position, respectively.

Magnetic Field Distribution Analysis of Superconducting Niobium Foil of Linear Type Magnetic Flux Pump using Simulation (시뮬레이션을 이용한 리니어형 자속 플럭스 펌프에서의 초전도 니오븀 박막의 자장분포 해석)

  • Lee, Eung-Ro;Chung, Yoon-Do;Bae, Duck-Kweon;Yoon, Yong-Soo;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.60-64
    • /
    • 2009
  • We investigated an operating characteristic of linear-type magnetic flux pump (LTMFP) as a current compensator under the various conditions. In order to explain the mechanism of the LTMFP, the magnetic behavior of superconducting Nb foil according to pumping actions should be understood. In this paper, the magnetic field analysis of superconducting Nb foil installed in LTMFP has been performed based on the three-dimensional finite element method (3D FEM). Through the simulation analysis, the normal spot region on the superconducting Nb foil is found to be enhanced swiftly over about 20 Hz. The simulated finding agreed with an analytical estimation based on the phenomenon of magnetic diffusion.