• 제목/요약/키워드: Current Probe

검색결과 568건 처리시간 0.024초

스캐닝 홀 프로브 측정 시스템의 데이터 측정 위치 표시 기술 (position marking technique for data measured in a scanning hall probe system)

  • 유재은;이재영;정예현;이상무;염도준
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.13-15
    • /
    • 2007
  • We employed home-made position marking module in the scanning Hall probe system. The module is composed of two coils of which gap, a, between wires in a coil is $500{\mu}m$. We appiled 10-35mA of current with 15Hz in the coils and recorded ac corresponding magnetic field signal with respect to measuring time while we measured DC field profiles produced due to superconducting film in a perpendicular magnetic field. We calibrate the position, x, of coils using the measuring time and location of the coils in the holder. The error range was about ${\pm}0.1mm$. We test the module as we applied current of 100A and filed of 1kG in the superconducting tape. It was confirmed that there was no interference between superconducting tape and marking coils.

Langmuir probe measurements of electron density and electron temperature in early stage of laser-produced carbon plasma

  • Hong, C.;Chae, H.B.;Lee, S.B.;Han, Y.J.;Jung, J.H.;Cho, B.K.;Park, H.;Kim, C.K.;Kim, S.O.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제1권1호
    • /
    • pp.32-39
    • /
    • 2000
  • Langmuir probe measurements of electron density, electron temperature and potential are mad in the early stage (<5${\mu}$s) of a laser ablated plasma plume, in which a positive current form positive ions and a electron current are overlapped. The plasma wes produced by focusing the second harmonic, 532 nm, of Q-switched Nd:YAG laser on a high purity carbon target. Then the laser intensity on the target of ~1.6${\times}$10$\^$15/ W/$\textrm{cm}^2$. The measured electron desities and temperatures are ~2${\times}$10/sip 11/ cm$\^$-3/ and -3 eV. In particluar , the phenomenon that the electron temperature decreased and then increased was observed,. It could be well explained that this phenomenon occurred in the process of inverse Bremsstrahlung of free electrons in plasma. Additionally, the plasma potential(>11V) was higher than the published values.

  • PDF

자장감쇠법을 이용한 $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag 초전도선재의 접합저항 측정 (Measurement of Joint Resistance of $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag Superconducting Tape by Field decay Technique)

  • 김정호;이승묵;주진호
    • Progress in Superconductivity
    • /
    • 제14권1호
    • /
    • pp.1-10
    • /
    • 2012
  • We fabricated a closed coils by using resistive-joint method and the joint resistance of the coils were estimated by field decay technique in liquid nitrogen. We used the Runge-kutta method for the numerical analysis to calculate the decay properties. The closed coil was wound by $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag tape. Both ends the tape were overlapped and soldered to each other. The current was induced in a closed coils by external magnetic flux density. Its decay characteristic was observed by means of measuring the magnetic flux density generated by induced current at the center of the closed coil with hall sensor. The joint resistance was calculated as the ratio of the inductance of the loop to the time constants. The joint resistances were evaluated as a function of critical current of loop, contact length, sweep time, and external magnetic flux density in a contact length of 7 cm. It was observed that joint resistance was dependent on contact length of a closed coil, but independent of critical current, sweep time, and external magnetic flux density. The joint resistance was measured to be higher for a standard four-probe method, compared with that for the field decay technique. This implies that noise of measurement in a standard four-probe method is larger than that of field decay technique. It was estimated that joint resistance was $8.0{\times}10^{-9}{\Omega}$ to $11.4{\times}10^{-9}{\Omega}$ for coils of contact length for 7 cm. It was found that 40Pb/60Sn solder are unsuitable for persistent mode.

Automated Analysis Technique Developed for Detection of ODSCC on the Tubes of OPR1000 Steam Generator

  • Kim, In Chul;Nam, Min Woo
    • 비파괴검사학회지
    • /
    • 제33권6호
    • /
    • pp.519-523
    • /
    • 2013
  • A steam generator (SG) tube is an important component of a nuclear power plant (NPP). It works as a pressure boundary between the primary and secondary systems. The integrity of a SG tube can be assessed by an eddy current test every outage. The eddy current technique(adopting a bobbin probe) is currently the main technique used to assess the integrity of the tubing of a steam generator. An eddy current signal analyst for steam generator tubes continuously analyzes data over a given period of time. However, there are possibilities that the analyst conducting the test may get tired and cause mistakes, such as: missing indications or not being able to separate a true defect signal from one that is more complicated. This error could lead to confusion and an improper interpretation of the signal analysis. In order to avoid these possibilities, many countries of opted for automated analyses. Axial ODSCC (outside diameter stress corrosion cracking) defects on the tubes of OPR1000 steam generators have been found on the tube that are in contract with tube support plates. In this study, automated analysis software called CDS (computer data screening) made by Zetec was used. This paper will discuss the results of introducing an automated analysis system for an axial ODSCC on the tubes of an OPR1000 steam generator.

비파괴검사 전용 시뮬레이터를 이용한 와전류검사 신호 시뮬레이션 (Simulation of Eddy Current Testing Signals Using Simulation Software Dedicated to Nondestructive Testing)

  • 이태훈;조찬희;이희종
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.75-81
    • /
    • 2014
  • A simulation of eddy current testing has been utilized for predicting the signal characteristics to the various defects and developing the probes. Especially, CIVA which is a simulation tool dedicated to nondestructive testing has a good accuracy and speed, and provides a three-dimensional graphical user interface for improved visualization and familiar data displays consistent with NDE technique. Although internal validations have been performed by the CIVA software development specialists, an independent validation study is necessary for the accuracy assessment of the software prior to practical use. For this purpose, in this study, eddy current testing signals of ASME FBH calibration standard tube for bobbin probe were simulated using CIVA and the results were compared to the experimental inspected signals based on the relationship between each flaw signal in terms of amplitude and phase, and the shape of the Lissajous curve. And then we verified the accuracy of the simulated signals and the possible range for simulation. Overall, there is a good qualitative agreement between the CIVA simulated and experimental results in the absolute and differential modes at the two inspection frequencies.

상완혈 자침시 복부 장기의 안전성 확보를 위한 초음파시스템의 신뢰도 측정 (Reliability Measurement of the Ultrasound for Safety of the Abdominal Organs on Acupuncturing Sangwan (CV13))

  • 김지혜;백태현
    • 대한한의진단학회지
    • /
    • 제15권2호
    • /
    • pp.203-214
    • /
    • 2011
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with a ultrasound device with three methods of 3.5 MHz convex probe and gel, 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad, three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver were 9.20 (9 MHz linear probe and gel), 14.70 (9 MHz linear probe and solid gel pad). So we concluded that repeatabilities and reproducibilities of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with the methods of 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad were acceptable.

증기발생기 전열관의 투자율 변화신호 분리를 위한 신형 탐촉자 개발 (Development of New ECT Probe Separating the Permebility Variation Signal in the SG Tube)

  • 박덕근;유권상;이정기;손대락
    • 비파괴검사학회지
    • /
    • 제28권1호
    • /
    • pp.9-15
    • /
    • 2008
  • 증기발생기 전열관에 생성되는 투자율변화에 의해 야기되는 신호왜곡 문제를 해결하기 위한 새로운 탐촉자를 개발하였다. 고리 1 호기 폐전열관에 생성된 자성상을 분리하여 자기이력곡선을 측정하였으며, 자성상이 생성되는 원인을 규명하기 위하여 고온 인장 시험을 수행하였다. 전산모사를 이용하여 탐촉자의 자정상 탐지조건을 결정하였으며, 디지털 신호전송을 위하여 신호처리용 전자회로를 소형화하여 탐촉자 속에 삽입하였다. 본 연구에서 개발된 신형 탐촉자를 이용하여 PVC 신호와 니켈 슬리빙 부위의 결함을 측정하였다. 신형 탐촉자는 보빈 탐촉자와 같이 고속으로 결함을 측정 할 수 있으며, 증기발생기 전열관의 탐상속도와 결함 탐지의 신뢰성을 증진시킬 수 있다.

전위강하법에 의한 접지저항측정에 미치는 전류보조전극의 영향 (Effects of the Current Probe on Ground Resistance Measurements Using Fall-of-Potential Method)

  • 이복희;엄주홍
    • 조명전기설비학회논문지
    • /
    • 제14권6호
    • /
    • pp.69-77
    • /
    • 2000
  • 본 논문에서는 찬우$\mid$강하법에 의한 접지저항 및 대지첸위 분표의 측캠시 전휴보조전극의 영향에 대하여 기술하였으며, 측정시 오치를 최소화하는 기법을 제안하였다. 전위강해법은 전위와 천류의 측정에 이론적인 비1깅을 두고 있으며, 측정오차는 주로 측정시 설치하는 보조전극의 위치와 자체저항에 기인한다. 피측정 접지전극의 접지저항은 전위강하법에서 전위보조전극을 피측정 접지전극과 전류보조전극이 이루는 일직선상에 위치시킬 때 61.8[%]법칙을 적용하여 측정한다. 하지만 건물이나 포장도로, 구조물 등이 산재해 있는 도심의 경우에는 현장에서 피측정 접지전극과 전류보조전극 사이에 적결한 이격거리 확보가 불가능하거냐 전류보조전극의 접지저행값이 피측정 챔 지전극에 비하여 큰 값을 가지는 경우가 있다. 파측정 접지천극과 전류보조전극을 충분히 이격시키지 않거나 전류류보조전극의 접지저항값이 피측청 접지전극의 접지저항보다 비정상척으로 큰 경우 접지저항의 측정은 오차를 수반하게 되며, 측정된 접지저항값은 오차즐 보정해 주어야 한다. 본 연구애서 측정대상 전극은 길이 2.4[m]의 봉형 접지전극으호 하였으며, 전류보조전극의 영향을 고려할 때 피측정 접지전극과 전류보조전극의 적정한 이격거리는 피측정 접치전극 길이의 5배 이상으로 하여야 전위보조전극을 사설하기가 용이하며 측정정확도의 확보에 유리하다. 또한 전류보존전극의 접지저항값이 피측정 접지전극의 접지저항값 약 36.5배 이하에서는 거의 오차를 발생시키지 않는다.

  • PDF

A Technique for Analyzing LSI Failures Using Wafer-level Emission Analysis System

  • Higuchi, Yasuhisa;Kawaguchi, Yasumasa;Sakazume, Tatsumi
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제1권1호
    • /
    • pp.15-19
    • /
    • 2001
  • Current leakage is the major failure mode of semiconductor device characteristic failures. Conventionally, failures such as short circuit breaks and gate breakdowns have been analyzed and the detected causes have been reflected in the fabrication process. By using a wafer-level emission-leakage failure analysis method (in-line QC), we analyzed leakage mode failure, which is the major failure detected during the probe inspection process for LSIs, typically DRAMs and CMOS logic LSIs. We have thus developed a new technique that copes with the critical structural failures and random failures that directly affect probe yields.

  • PDF