• 제목/요약/키워드: Current Mode Converter

검색결과 674건 처리시간 0.028초

공간전압벡터 PWM을 이용한 컨버터/인버터 시스템에서의 커먼 모드 전압 펄스 제거 (Elimination of a Common Mode Voltage Pulse in Converter/Inverter System Modifying Space-Vector PWM Method)

  • 이현동;이영민;설승기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권2호
    • /
    • pp.89-96
    • /
    • 1999
  • This paper proposes a common-mode voltage reduction method base on SVPWM(Space-Vector Pulsewidth Modulation) in three phase PWM converter/inverter system. By shifting the active voltage vector of inverter and aligning this to the active vector of converter, it is possible to eliminate a common-mode voltage pulse in one control period. Since the proposed PWM method maintains the active voltage vector, it does not affect the control performance of PWM converter/inverter system. Without any extra hardware, overall common mode voltage dv/dt and conrresponding leakage current can be reduced to two-third of the conventional three phase symmetric SVPWM scheme.

  • PDF

고속 스위칭에 의한 만능 전려변화기 구성 (Universal power converter using High-Speed Switching)

  • 이스난도;프라요가 부디;최우석;박성준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.337-338
    • /
    • 2013
  • Combination the several type of single phase power conversion utilized simply topology are proposed in this paper. Totally four kind of converter are investigated, they are Boost AC/AC Converter, Buck AC/AC Converter, Boost AC/DC Converter, and Buck DC/AC Converter. Two types action mode are presented to determine the functional of circuit. First is AC chopper action mode, representation of the AC/AC converter. AC chopper action mode offered the sinusoidal current waveform, better power factor, faster dynamics, and smaller input/output filter. They present high robustness, offer safe commutation and have high efficiency. The second is full bridge action mode, determined the transformation AC to DC power and otherwise. Four switching devices and one magnetic contactor will establish the mode operation of circuit and manage the flow of power proceed in proper. The correction and advance of the kind of converter are verified by simulation.

  • PDF

0.35um 공정에서 OFDM 용 전류모드 FFT LSI를 위한 I-V Converter 설계 (Design of Current-to-Voltage Converter for the Current-mode FFT LSI in 0.35um processing)

  • 배성호;홍순양;전성용;김성권
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2007년도 춘계학술대회 학술발표 논문집 제17권 제1호
    • /
    • pp.469-472
    • /
    • 2007
  • 최근 많은 광대역 유무선 통신 응용분야에서 OFDM(Orthogonal Frequency Division Multiplexing) 방식을 표준기술로 채택하고 있다 OFDM 방식의 고속 무선 데이터 통신를 위한 FFT 프로세서는 일반적으로 DSP(Digital Signal Processing)로 구현되었으나, 큰 전력 소비를 필요로 한다. OFDM의 단점인 전력문제를 보안하기 위해서 Current-mode FFT LSI가 제안되었다. 본 논문에서는 Current-mode FFT LSI의 구현을 위한 저전력 IVC를 설계하였다. 설계된 IVC는 FFT Block의 출력이 $13.65{\mu}A$ 이상일 때에 3V 이상의 전압을 출력하고, FFT Block의 출력이 $0.15{\mu}A$ 이하일 때에 0.5V 이하의 전압을 출력한다. 그리고 IVC의 총 소모전력은 약 1.65mW이다. $0.35{\mu}A$ 공정에서의 저전력 IVC를 설계함으로서, $0.35{\mu}A$ 공정에서의 Current-mode FFT LSI의 설계가 가능해졌다. 저전력 OFDM 통신용 Current-mode FFT LSI는 무선통신의 발전에 기여할 것으로 전망한다.

  • PDF

불연속 전류모드로 동작하는 Interleaved 승압형 역률보상 컨버터의 입력전류 리플개선 (Input Current Ripple Improvement on Interleaved Boost Power Factor Corrector Operating in Discontinuous Current Mode)

  • 허태원;박지호;노태균;김동완;박한석;우정인
    • 조명전기설비학회논문지
    • /
    • 제17권1호
    • /
    • pp.116-123
    • /
    • 2003
  • 본 논문에서는 SMPS의 교류 입력측 역률을 개선시킬 수 있는 전치 레귤레이터로서 interleaved 승압형 컨버터를 관하여 연구하였다. Interleaved 승압형 역률보상 컨버터(IBPFC)는 입력전류를 두 개의 스위칭 소자에 의하여 50%씩 나누어져 흐르게 함으로써, 내부 전류제어 루프 얼이 전압제어 루프만으로 제어계를 구성하여 입력전류 리플을 줄일 수 있다. 즉, IBPFC를 구성하는 각각의 부스트 컨버터 cell을 불연속 전류모드로 동작시키더라도 전체적인 입력전류의 파형은 연속이 되어 입력전류 리플이 감소하게 된다. 불연속 전류모드로 동작하는 IBPFC를 해석하기 위하여 스위칭 상태에 따라서 6개의 모드로 구분하여 상태방정식을 구하였다. 또한, 각 상태방정식을 상태공간 평균화법을 이용하여 모델링하고, 미소변동분을 고려한 소신호 해석을 통하여 제어전달함수를 구할 수 있다. 또한, 제어전달함수를 이용하여 단일 전압제어 루프를 가지는 제어계를 설계하였으며, 이러한 해석 및 설계를 바탕으로 실험을 통하여 IBPFC의 역률개선 및 리플저감을 확인하였다.

절연형 고효율 PFC AC-DC 컨버터에 관한 연구 (A Study on PFC AC-DC Converter of High Efficiency added in Electric Isolation)

  • 곽동걸;김상훈
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1349-1355
    • /
    • 2009
  • This paper is studied on a novel power factor correction (PFC) AC-DC converter of high efficiency by soft switching technique. The input current waveform in the proposed converter is got to be a sinusoidal form composed of many a discontinuous pulse in proportion to the magnitude of a ac input voltage under the constant switching frequency. Therefore, the input power factor is nearly unity and the control method is simple. The proposed converter adding an electric isolation operates with a discontinuous current mode (DCM) of the reactor in order to obtain some merits of simpler control, such as fixed switching frequency, without synchronization control circuit used in continuous current mode (CCM). To achieve the soft switching (ZCS or ZVS) of control devices, the converter is constructed with a new loss-less snubber for a partial resonant circuit. It is that the switching losses are very low and the efficiency of the converter is high, Particularly, the stored energy in a loss-less snubber capacitor recovers into input side and increases input current from a resonant operation. The result is that the input power factor of the proposed converter is higher than that of a conventional PFC converter. This paper deals mainly with the circuit operations, theoretical, simulated and experimental results of the proposed PFC AC-DC converter in comparison with a conventional PFC AC-DC converter.

태양광 마이크로 인버터를 위한 탭인덕터 부스트 및 강압형 컨버터 캐스케이드 타입 저가형 고효율 전력변환기 (Low-Cost High-Efficiency Two-Stage Cascaded Converter of Step-Down Buck and Tapped-Inductor Boost for Photovoltaic Micro-Inverters)

  • 장종호;신종현;박종후
    • 전력전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.157-163
    • /
    • 2014
  • This paper proposes a two-stage step-down buck and a tapped-inductor boost cascaded converter for high efficiency photovoltaic micro-inverter applications. The proposed inverter is a new structure to inject a rectified sinusoidal current into a low-frequency switching inverter for single-phase grid with unity power factor. To build a rectified-waveform of the output current. the converter employs both of a high efficiency step-up and a step-down converter in cascade. In step-down mode, tapped inductor(TI) boost converter stops and the buck converter operates alone. In boost mode, the TI converter operates with the halt of buck operation. The converter provides a rectified current to low frequency inverter, then the inverter converts the current into a unity power-factor sinusoidal waveform. By applying a TI, the converter can decrease the turn-on ratios of the main switch in TI boost converter even with an extreme step-up operation. The performance validation of the proposed design is confirmed by an experimental results of a 120W hardware prototype.

다상 교호 승압컨버터의 전류평형제어기를 이용한 전류모드제어기 구현 (Implementation of Current Mode Control using Current Balance Controller of Multi-Phase Interleaved Boost Converter)

  • 박종규;최현칠;신휘범
    • 조명전기설비학회논문지
    • /
    • 제22권12호
    • /
    • pp.157-163
    • /
    • 2008
  • 다상 교호 컨버터에서 인덕턴스가 불일치 할 때 첨두전류 제어기를 사용하는 경우에 각 상의 평균 전류는 동일하지 않다. 본 논문에서는 각 상의 인덕턴스가 불일치한 경우에 첨두전류 모드에서 평균전류가 동일해지는 전류분배 제어기를 제안한다 제어기는 과도상태에서도 전류의 평형이 잘 이루어질 수 있도록 설계한다. 제안된 방법을 2상과 4상 교호 승압컨버터에 적용시켰으며, 실험 결과를 통해 인덕턴스가 불일치한 경우에도 첨두전류 모드에서 전류평형이 잘 이루어짐을 보인다.

전류모드 OFDM FFT LSI를 위한 전류모드 직병렬/병직렬 변환기 (Current-Mode Serial-to-Parallel and Parallel-to-Serial Converter for Current-Mode OFDM FFT LSI)

  • 박용운;민준기;황성호
    • 한국인터넷방송통신학회논문지
    • /
    • 제9권1호
    • /
    • pp.39-45
    • /
    • 2009
  • 본 논문에서는 최근 무선 통신 시스템에서 빠른 데이터전송 방식으로서 사용되고 있는 OFDM 통신방식의 저소비전력화 방안을 제안한다. 일반적으로 OFDM에서 주요 신호처리 방식은 디지털을 이용한 프리에 변환이다. 이런 디지털 프리에 변환은 많은 소비전력이 필요하며 이것은 무선통신 시스템에 있어서 커다란 제약이 되고 있다. 전류모드를 이용한 아날로그 프리에 변환(FFT) LSI는 이러한 소비전력의 문제를 해결할 수 있는 주요 대안으로 떠오르고 있다. 그러나 이러한 신호처리 방식을 사용하기 위해서는 전류모드를 이용한 직병렬/병직렬 변환기(Serial-to-Parallel/Parallel-to-Serial Converter)가 필수적으로 필요하다. 본 논문에서는 전류모드로 구성한 아날로그 프리에 변환(FFT) LSI를 이용해 수신단의 저소비전력을 실현하기 위해 필수적인 새로운 전류모드 직병렬/병직렬 변환기를 제시하였으며 설계된 칩의 측정결과가 시뮬레이션 결과와 일치하는 것을 확인하였다. 제안된 전류모드 직병렬/병직렬 변환기의 개발로 저소비전력에 큰 장점을 지니고 있는 아날로그 FFT LSI의 활용이 가능해졌으며 송수신단 시스템에서 큰 소비전력의 감소효과를 가져올 것으로 기대된다.

  • PDF

Reducing Current Distortion in Indirect Matrix Converters Operating in Boost Mode under Unbalanced Input Conditions

  • Choi, Dongho;Bak, Yeongsu;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1142-1152
    • /
    • 2019
  • This paper presents a control method for reducing the current distortion in an indirect matrix converter (IMC) operating in boost mode under unbalanced input conditions. IMCs operating in boost mode are useful in distributed generation (DG) systems. They are connected with renewable energy systems (RESs) and the grid to transmit the power generated by the RES. However, under unbalanced voltage conditions of the RES, which is connected with the input stage of the IMC operating in boost mode, the input-output currents are distorted. In particular, the output current distortions cause a ripple of the power, which is transferred to the grid. This aggravates the reliability and stability of the DG system. Therefore, in this paper, a control method using positive/negative sequence voltages and currents is proposed for reducing the current distortion of both side in IMCs operating in boost mode. Simulation and experimental results have been presented to validate effectiveness of the proposed control method.

Design and Analysis of an Interleaved Boundary Conduction Mode (BCM) Buck PFC Converter

  • Choi, Hangseok
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.641-648
    • /
    • 2014
  • This paper presents the design considerations and analysis for an interleaved boundary conduction mode power factor correction buck converter. A thorough analysis of the harmonic content of the AC line current is presented to examine the allowable voltage gain (K value) for meeting the EN61000-3-2, Class D standard while maximizing efficiency. The results of the harmonic analysis are used to derive the required value of K and therefore the output voltage necessary to meet the class D requirements for a given AC line voltage. The discussed design consideration and harmonic current analysis are verified on a 300W universal line experimental prototype converter with an 80V output. The measured efficiencies remain above 96% down to 20% of the full load. The input current harmonics also meet the IEC61000-3-2 (class D) standard.