• Title/Summary/Keyword: Current Density

Search Result 5,725, Processing Time 0.039 seconds

Effect of Metal Mask Screen on Metal-induced Recombination Current and Solar Cell Characteristics (금속 마스크 스크린이 금속 재결합 전류와 태양전지 특성에 미치는 영향)

  • Lee, Uk Chul;Jeong, Myeong Sang;Lee, Joon Sung;Song, Hee-eun;Kang, Min Gu;Park, Sungeun;Chang, Hyo Sik;Lee, Sang Hee
    • Current Photovoltaic Research
    • /
    • v.9 no.1
    • /
    • pp.6-10
    • /
    • 2021
  • The mesh mask screen, which is generally used for screen printing metallization of silicon solar cell, requires high squeegee pressure and low printing speed. These requirements are acting as a limiting factor in production yield in photovoltaic industries. In order to improve the productivity, a metal mask, which has high durability and high printing speed, has been researched. In this paper, the characteristics of each solar cell, in which electrodes were formed by using a metal mask and a mesh mask, were analyzed through recombination current density. In particular, the metal-induced recombination current density (Jom) representing the recombination of the emitter-metal interface was calculated using the shading method, and the resulting efficiency and open-circuit voltage were analyzed through the diode equation. As a result of analyzing the proportion of the metal-induced recombination current density to the total emitter recombination current density, it was analyzed that the reduction of the metal-induced recombination current density through the metal mask is an important factor in reducing the total recombination current density of the solar cell.

Optimum Design Criteria for Maximum Torque Density & Minimum Current Density of a Line-Start Permanent-Magnet Motor using Response Surface Methodology & Finite Element Method (반응표면법과 유한요소법을 이용한 라인-스타트 영구 자석 전동기의 최대토크밀도와 최소전류밀도을 위한 최적설계)

  • Jang, Soon-Myung;Jun, Myung-Jin;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1055-1056
    • /
    • 2011
  • This paper deals with optimum design criteria for maximum torque density & minimum current density of a single phase line-start permanent-magnet motor (LSPMM) using RSM (Response Surface Methodology) & FEM (Finite Element Method). The focus of this paper is to find a design solution through the comparison of torque density and minimum current density resulting from rotor shape variations. And then, a central composite design (CCD) mixed resolution is introduced, and analysis of variance (ANOVA) is conducted to determine the significance of the fitted regression model.

  • PDF

Microstructural Characteristics of Electro-Plated Cu Films by DC and Pulse Systems (DC, pulse 조건에 따른 구리 도금층 미세 조직 관찰)

  • Yoon, Jisook;Park, Chansu;Hong, Soonhyun;Lee, Hyunju;Lee, Seungjun;Kim, Yangdo
    • Korean Journal of Materials Research
    • /
    • v.24 no.2
    • /
    • pp.105-110
    • /
    • 2014
  • The aim of this work was to investigate the effects of electrodeposition conditions on the microstructural characteristics of copper thin films. The microstructure of electroplated Cu films was found to be highly dependent on electrodeposition conditions such as system current and current density, as well as the bath solution itself. The current density significantly changed the preferred orientation of electroplated Cu films in a DC system, while the solution itself had very significant effects on microstructural characteristics in a pulse-reverse pulse current system. In the DC system, polarization at high current above 30 mA, changed the preferred orientation of Cu films from (220) to (111). However, Cu films showed (220) preferred orientation for all ranges of current density in the pulse-reverse pulse current system. The grain size decreased with increasing current density in the DC system while it remained relatively constant in the pulse-reverse pulse current system. The sheet resistance increased with increasing current density in the DC system due to the decreased grain size.

Effect of Electrolysis Conditions on Hard Chromium Deposition from Trivalent Chromium Bath (경질용 3가 크롬전착에 미치는 전해조건의 영향)

  • Kim, Dae-Young;Park, Sang-Eon;Kim, Man;Kwon, Sik-Chul;Choi, Ju-Won;Choi, Yong
    • Journal of Surface Science and Engineering
    • /
    • v.36 no.2
    • /
    • pp.155-160
    • /
    • 2003
  • The effect of the temperature, current density and deposit time on hard chromium deposition in trivalent chromium bath was investigated. Cathode current efficiency increased with increasing current density. Increasing bath temperature from $20^{\circ}C$ to $50^{\circ}C$, chromium deposits were produced in higher current density and the maximum current efficiency was increased. At the plating conditions of $40^{\circ}C$, $30A/dm\m^2$, the deposition thickness increased in proportion to increasing electrolysis time The rate is$ 90\mu\textrm{m}$/hrs. for 2 hours. Microhardness of chromium deposits increased with increasing bath temperature and decreasing current density, and it was constant with electrolysis time. All of bath conditions, microstructure of chromium deposits has nodular structure with some cracking pattern and nodule size increased with increasing deposit thickness.

A Study on the Effect of the Contact Electrode Slits in the Vacuum Interrupter with Axial Magnetic Field Type (종자계형 진공 인터럽터에서 접점전극 슬릿의 영향에 관한 연구)

  • 하덕용;강형부;최승길;최경호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.9
    • /
    • pp.822-829
    • /
    • 2002
  • This paper deals with the distribution characteristics of the current density and axial magnetic flux density for each slits made on the contact electrode in the vacuum interrupter with axial magnetic field type using 3-dimension finite element analysis. It has been known that the presence of an axial magnetic field parallel to the current flow in the arc plasma can increase the high current breaking capacity of vacuum interrupter by carrying out the arc plasma from constricted mode to diffusion mode. The axial magnetic field is created of itself by current flow in the segments of coil electrode behind the contact electrode. The analyzed results show that if the slits are made in the contact electrode, they can increase the current density and axial magnetic flux density in the contact electrode surface and at the gap distance, which is due to decrease the effect of eddy currents flowing in the contact electrode. The phase shift due to eddy currents, defined 3s time difference between the maximum value of current and axial magnetic field, is decreased still more by increasing the number of slits made in the contact electrode at the center point of gap distance. These results demonstrate that 3-dimension finite element analysis has a great deal of merits in the development and evaluation of new electrode at the design of vacuum interrupter.

Sulfur Poisoning of Ni Anode as a Function of Operating Conditions in Solid Oxide Fuel Cells (고체산화물 연료전지의 운전 조건에 따른 니켈 전극 황 피독 현상)

  • Lee, Ho Seong;Lee, Hyun Mi;Lim, Hyung-Tae
    • Korean Journal of Metals and Materials
    • /
    • v.56 no.12
    • /
    • pp.893-899
    • /
    • 2018
  • In the present study, we investigated the sulfur poisoning of the Ni anode in solid oxide fuel cells (SOFCs) as a function of operating conditions. Anode supported cells were fabricated, and sulfur poising tests were conducted as a function of current density, $H_2S$ concentration and humidity in the anode gas. The voltage drop was significant under the higher current density (${\sim}714mA/cm^2$) condition, while it was much reduced under the lower current density (${\sim}389mA/cm^2$) condition, at 100 ppm of $H_2S$. A secondary voltage drop, which occurred only at the high current density, was attributed to Ni oxidation in the anode. Thus, operation at high current density with high $H_2S$ concentration may lead to permanent deterioration in the anode. The effect of water content (10%) on the sulfur poisoning was also investigated through a constant current test (${\sim}500mA/cm^2$) at 10 ppm of $H_2S$. The cell operating with 10% wet anode gas showed a much smaller initial voltage drop, in comparison with a dry anode gas. The present study indicates that operating conditions, such as gas humidity and current density, should be carefully taken into account, especially when fuel cells are operated with $H_2S$ containing fuel.

Numerical Analysis of Circulation Due to Density Current in a Small Reservoir (소규모 저수지에서 밀도류 순환의 수치해석)

  • Yoon, Tae Hoon;Han, Woon Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.105-114
    • /
    • 1993
  • The ciculation due to bottom density current produced by a dense inflow into a small reservoir is analysed by numerical scheme. Before the front of the density current arrives at the downstream end, the mixing in the reservoir is mainly caused by the anticlockwise vortex formed at the downstream of plunging point along the movement of bottom density current. Upon the arrival of the front of the density current at the downstream end an internal surge is created through an internal hydraulic jump. With repeated propagation of the internal surge back and forth the mixing in the reservoir is progressed and the thickness of dense layer is increased upward. The dilution of the overflow at downstream end is found to depend on inflow densimetric Froude number, reservoir length and elapsed time. The time required for the overflow to attain a specified dilution increases as reservoir length increases and Fre decreases.

  • PDF

Effects of Domestic Wastewater Treatment used Biofilm-Electrode Reactor(BER) (生物膜 電極反應機를 이용한 廚房廢水 처리 효과)

  • Noh, Hyun-Woong;Yoon, Oh-Sub
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.1
    • /
    • pp.43-49
    • /
    • 1997
  • This study was aimed to estimate removal efficiency(%) of BER(Biofilm-Electrode Reactor) and A.S(Activated Sludge) treatments. When were analyzed COD$_{Cr}$, NH$_3$-N and T-P by current density and reaction time, the results were as follows : 1) In BER treatment, the removal efficiency of COD$_{Cr}$ in domestic wastewater was 79-86% when current density was 2.39 mA/dm$2$(15mA)-3.98 mA/dm$^2$(25mA) and reaction time was 48 hr. 2) Removal efficiency of NH$_3$-N was 71-73% when current density was 2.39-3.98 mA/dm$^2$ and reaction time 48 hr. 3) When the reaction time was 48 hr removal efficiency(%) of BER treatment for COD$_{Cr}$, NH$_3$-N and T-P were more excellent than A.S. treatment. And then we prospect that was because activated microorganism colonies attached in biofilm on surface of electrode pannel. Therefore, In order to derive BER treatment efficiency(%) should establish optimum conditions of pH, temp., reaction time, current density and biochemical and electrochemical states.

  • PDF

High-rate growth $YBa_2$$Cu_3$$O_{7-x}$ thick films and thickness dependence of critical current density (Y$Ba_2$$Cu_3$$O_{7-x}$ 후막의 고속 증착과 임계 전류 밀도의 두께 의존성)

  • Jo W.
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.13-18
    • /
    • 2004
  • High-.ate in-situ$ YBa_2$Cu$Cu_3$$O_{7-x}$ (YBCO) film growth was demonstrated by means of the electron beam co-evaporation. Even though our oxygen pressure is low, ∼$5 ${\times}$10^{-5}$ Torr, we can synthesize as-grown superconducting YBCO films at a deposition rate of around 10 nm/s. Relatively high temperatures of around 90$0^{\circ}C$ was necessary in this process so far, and it suggests that this temperature at a given oxygen activity allows a Ba-Cu-O liquid formation along with an YBCO epitaxy. Local critical current density shows a clear correlation with local resistivity. Homogeneous transport properties with a large critical current density ($4 ∼ 5 MA/\textrm{cm}^2$ at 77K, 0T) are observed in top faulted region while it is found that the bottom part carries little supercurrent with a large local resistivity. Therefore, it is possible that thickness dependence of critical current density is closely related with a topological variation of good superconducting paths and/or grains in the film bodies. The information derived from it may be useful in the characterization and optimization of superconducting films for electrical power and other applications.

  • PDF

Change of the Efficiency in All-Vanadium Redox Flow Battery with Current Density (전류밀도에 따른 바나듐 레독스 흐름 전지의 효율 변화)

  • CHOI, HO-SANG;IN, DAE-MIN;SONG, YOUNG-JOON;RYU, CHEOL-HWI;HWANG, GAB-JIN
    • Journal of Hydrogen and New Energy
    • /
    • v.28 no.5
    • /
    • pp.531-535
    • /
    • 2017
  • The performance of all-vanadium redox flow battery (VRFB) was tested with an increase of the current density. APS membrane (anion exchange membrane) and GF050CH (cabon felt) were used as a separator and electrode, respectively. An average energy efficiency of the VRFB was 79.5%, 68.1%, and 62.8% for the current density of $60mA/cm^2$, $120mA/cm^2$, and $160mA/cm^2$, respectively. It was confirmed that VRFB can be used as a energy storage system at the higher current density even if the energy efficiency was deceased about 21%.