• 제목/요약/키워드: Current Compensation

검색결과 1,233건 처리시간 0.031초

Sampled-Data Modeling and Dynamic Behavior Analysis of Peak Current-Mode Controlled Flyback Converter with Ramp Compensation

  • Zhou, Shuhan;Zhou, Guohua;Zeng, Shaohuan;Xu, Shungang;Cao, Taiqiang
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.190-200
    • /
    • 2019
  • The flyback converter, which can be regarded as a nonlinear time-varying system, has complex dynamics and nonlinear behaviors. These phenomena can affect the stability of the converter. To simplify the modeling process and retain the information of the output capacitor branch, a special sampled-data model of a peak current-mode (PCM) controlled flyback converter is established in this paper. Based on this, its dynamic behaviors are analyzed, which provides guidance for designing the circuit parameters of the converter. With the critical stability boundary equation derived by a Jacobian matrix, the stable operation range with a varied output capacitor, proportional coefficient of error the amplifier, input voltage, reference voltage and slope of the compensation ramp of a PCM controlled flyback converter are investigated in detail. Research results show that the duty ratio should be less than 0.5 for a PCM controlled flyback converter without ramp compensation to operate in a stable state. The stability regions in the parameter space between the output capacitor and the proportional coefficient of the error amplifier are enlarged by increasing the input voltage or by decreasing the reference voltage. Furthermore, the ramp compensation also can extend to the stable region. Finally, time-domain simulations and experimental results are presented to verify the theoretical analysis results.

태양광 PV 어레이에서 병렬 부정합을 저감시키는 모듈 부정합 보상기법 (Method for PV Module Mismatch Compensation to Reduce Parallel Mismatch in Solar PV Array)

  • 박기엽;안희욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.170-171
    • /
    • 2010
  • The power loss due to PV module mismatch in PV array system is analyzed and a mismatch compensation method is proposed. A dc-dc converter is used to compensate for series mismatch caused by a low current module in a string. The converter is controlled to maximize the array power output. The proposed compensation method was verified by PSpice simulation.

  • PDF

2-leg 3상 PWM 인버터의 출력전압에서 직류링크 리플 전압의 영향 보상 (Compensation of Effects of DC-Link Ripple Voltages on Output Voltage of Two-leg Three-Phase PWM Inverters)

  • 김영신;이동춘;석줄기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.572-574
    • /
    • 2005
  • In this paper, a compensation scheme for the effect of dc-link ripple voltages on output voltage of two-leg and three-phase PWM inverters is proposed, without which compensation scheme the three-phase output voltage and current are much distorted. The proposed scheme has been verified by experimental results.

  • PDF

2.4 GHz WLAN InGaP/GaAs Power Amplifier with Temperature Compensation Technique

  • Yoon, Sang-Woong;Kim, Chang-Woo
    • ETRI Journal
    • /
    • 제31권5호
    • /
    • pp.601-603
    • /
    • 2009
  • This letter presents a high performance 2.4 GHz two-stage power amplifier (PA) operating in the temperature range from $-30^{\circ}C$ to $+85^{\circ}C$ for IEEE 802.11g, wireless local area network application. It is implemented in InGaP/GaAs hetero-junction bipolar transistor technology and has a bias circuit employing a temperature compensation technique for error vector magnitude (EVM) performance. The technique uses a resistor made with a base layer of HBT. The design improves EVM performance in cold temperatures by increasing current. The implemented PA has a dynamic EVM of less than 4%, a gain of over 26 dB, and a current less than 130 mA below the output power of 19 dBm across the temperature range from $-30^{\circ}C$ to $+85^{\circ}C$.

전류형 인버터로 구동되는 유도 전동기의 슬립 주파수 제어와 주파수 보상에 관한 연구 (A Study on Slip Frequency Control And Frequency Compensation in CSIM)

  • 전희종;김춘수;이명우;정원석;안재우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.306-309
    • /
    • 1988
  • For the purpose of fast response and simplifing system angle control strategy is selected. And the analysis and dynamic performance of a slip frequency controlled current source inverter fed induction motor drive with stator frequency compensation (indirect torque angle control) is investigated. The current control loop including motor is modeled and speed control loop including the frequency compensation is analysed. And transfer function of overal system is simplified. Experimental results are given in support of the analytical procedure.

  • PDF

고성능 속도 제어를 위한 옵셋 전류와 전동기 상불평형 보상 (Compensation of Offset Current and Motor Asymmetry for High Performance Speed Control)

  • 정대웅;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.274-276
    • /
    • 1995
  • The non-ideal elements inherent in all categories of AC drives have a significant influence on the performance of speed control. For the high performance of speed control, these non-ideal elements must be considered. This paper discusses the side effects of non-ideal elements such as the offset current of A/D converter, asymmetry of motor and so on and proposes simple compensation methods which are also applicable to any kinds of the motor drive systems. In the experimental results, it is observed that the proposed compensation methods improve the performance of speed control.

  • PDF

Multifunctional Uninterruptible Power Supply (UPS) System

  • Kim, Je-Hong;Choi, Yong-Joon;Choi, Jae-Ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.813-817
    • /
    • 1998
  • This paper proposes a new control strategy of bidirectional uninterruptible power supply(UPS) with the performance of active power filter which compensate the harmonics and reactive power. To improve the transient response for the effective compensation in active power filter mode. It is considered that a simple and precise calculation method of the compensation reference current for the harmonics and reactive power compensation. So a novel closed-loop control strategy is used to calculate the reference current. The system model and control algorithm are described and the system performance is verified by the simulation and experimental results.

  • PDF

순간전압변동 보상 기능을 갖는 3상 하이브리드형 직렬 능동전력필터 (3-Phase Hybrid Series Active Power Filter with Instantaneous Voltage Fluctuations Compensation)

  • 한석우;최규하
    • 전력전자학회논문지
    • /
    • 제5권6호
    • /
    • pp.544-551
    • /
    • 2000
  • In this paper, 3-phase hybrid series active power filter for compensate current harmonics, voltage drop and unbalanced voltage in the network presented. The proposed system is implemented with a space vector modulation voltage source inverter and a high pass filter connected in parallel to the power system. Here the load is six-pulses thyristor rectifier. The phase angle detected in order to generation reference voltage at load terminal is synchronized with the positive sequence component of the unbalanced source by using symmetrical component transformation. The proposed system has an function harmonic isolation between source and load, voltage regulation, and unbalance compensation. Therefore, what the power system is improved quality, the source current is maintained as a nearly sinusoidal waveform and the load voltage is regulated with a rated voltage regardless of the source variation condition. To verify the validity of the proposed compensating system, the computer simulation and experiment are carried out.

  • PDF

전력조류 제어에 의한 병.직렬 능동전력필터 시스템 (Unified Active Power Filter System of control Power Flow)

  • 강민형;양이우;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.984-985
    • /
    • 2006
  • This paper presents control algorithms for unified active power filter. The algorithm is based in the performance function. The performance function is defined, and the compensation voltage reference is calculated for harmonics voltage and the compensation current reference is calculated for power factor. The proposed control algorithm can be applied to 3-phase 3-wire system and has a superior compensation characteristics for both harmonic current sources and harmonic voltage sources.

  • PDF

Analysis and Compensation Control of Dead-Time Effect on Space Vector PWM

  • Shi, Jie;Li, Shihua
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.431-442
    • /
    • 2015
  • Dead-time element must be set into space vector pulsed width modulation signals to avoid short circuits of the inverter. However, the dead-time element distorts the output voltage vector, which deteriorates the performance of electrical machine drive system. In this paper, dead-time effect and its compensation control strategy are analyzed. Based on the analysis, the voltage distortion caused by dead-time is regarded as two disturbances imposed on dq axes in the rotor reference frame, which degenerates the current tracking performance. To inhibit the adverse effect caused by the dead-time, a control scheme using two linear extended state observers is proposed. This method provides a strong ability to suppress dead-time effects. Simulations and experiments are conducted on a permanent magnet synchronous motor drive system to demonstrate the effectiveness of the proposed method.