• Title/Summary/Keyword: Current Bleeding

Search Result 76, Processing Time 0.031 seconds

Need to Reduce Industrial Accidents through the Introduction of an Prevailing Wage System (적정임금제 도입을 통한 산업재해 감축 필요성 고찰)

  • Choonhwan Cho;Yeoncheol Shin;Kyung-Bo Han
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • In order to carry out construction work, it is urgent to introduce a proper wage system so that the cost burden of projects that have been won due to bleeding competition among original government buildings based on low-priced bids can be transferred to subcontractors. Purpose: Construction with illegal multi-level industrial structure needs to improve the wage reduction environment leading to order (100%) → original contractor (80%) → subcontractor (65%) → load contractor (65%) and aims to ensure wages for end workers. Method: Investigate the current status of labor cost appropriate payment plan in the construction industry, and investigate the case of the appropriate wage system (P.W) in the United States. In addition, the effect and direction of the appropriate wage system are presented. Result: Individual minimum wage security was also mentioned in the Constitution, and many researchers suggested that only the introduction of an appropriate wage system could solve the problem of reducing worker labor and ensure quality and safety. Conclusion: The proper wage system in the construction industry will block illegal multi-level and illegal foreign work, improve the labor environment in the construction market, create an influx of young workers, and have a significant impact on the construction industry's competitive structure, safety, and quality.

Infantile Hypertrophic Pyloric Stenosis - A Survey by the Korean Association of Pediatric Surgeons - (영아 비후성 유문협착증 - 대한소아외과학회 정회원을 대상으로 한 전국조사 -)

  • Kim, I.K.;Kim, S.Y.;Kim, S.K.;Kim, W.K.;Kim, J.E.;Kim, J.C.;Kim, H.H.;Park, K.W.;Park, Y.S.;Park, W.H.;Song, Y.T.;Yang, J.W.;Oh, S.M.;Yoo, S.Y.;Lee, D.S.;Lee, M.D.;Lee, S.K.;Lee, S.C.;Chang, S.I.;Chung, S.Y.
    • Advances in pediatric surgery
    • /
    • v.4 no.2
    • /
    • pp.149-155
    • /
    • 1998
  • Thirty three members of the Korean Association of Pediatric Surgeons were surveyed to determine the clinical manifestations and current management of infantile hypertrophic pyloric stenosis (IHPS). The members completed a registration form and a questionnaire that indicated their treatment preferences for patients treated during 1996. The response rate was 84.8 %, and 23 institutions participated. Three hundred and sixty-three cases of IHPS were analysed. The male to female ratio was 5.15: 1. The presenting symptoms were nonbilious vomiting in 363 cases(100 %), palpable mass in the upper abdomen in 200 cases (55.1 %) and visible peristaltic waves in 67 cases(18.5 %). Fluid therapy was done in 161 cases(44.4 %) for preoperative preparation. Twenty patients(5.5 %) were premature. There were 27 low birth weight babies(7.7 %). The onset of symptoms ranged from 1 to 14 weeks of age with a peak occurrence at 2 to 4 weeks of age. Two hundred and thirty-six cases(66.6 %) presented within 4 weeks of age. There was one set of male twins and a family history of twins. The modes of feedings were: breast feeding; 69 cases(24.5 %), formula feeding; 176 cases(62.4 %) and mixed feeding; 37 cases(13.1 %). The preferred diagnostic modalities were ultrasonography (US) 229 cases(63.1 %), UGI series 27 cases(7.4%) and US and UGI series combined 86 cases(23.7 %). Only 21 cases(5.8 %) were operated on without imaging study, ie. with positive physical finding. Perforation of the mucosa during pyloromytomy occurred in 5 cases. All were treated successfully with primary closure. Persistent vomiting over 2 weeks after operation were reported in 5 cases. Three wound infections, one aspiration pneumonia and one postoperative bleeding were reported. There was no mortality in 363 cases.

  • PDF

Clinical Results Following Early Tailoring Thoracoplasty in Patients Undergoing Pulmonary Resection (폐의 부분절제수술를 시술받은 환자에서 조기 변형식 흉곽성형수술에 따른 임상결과)

  • Choi, Soon-Ho;Cha, Byung-Ki;Lee, Mi-Kyung;Park, Kwon-Jae;Lee, Sam-Youn;Choi, Jong-Bum
    • Journal of Chest Surgery
    • /
    • v.40 no.7 s.276
    • /
    • pp.485-491
    • /
    • 2007
  • Background: Thoracoplasty has become a rarity in current clinical practice, although it has been widely employed for well over a century as a procedure for reducing the capacity of the thoracic cavity. Yet we have perform tailoring thoracoplasty following or concomitant with pulmonary resection in 20 patients. The aim of this study is to evaluate the early and late clinical results and also the significance of tailoring thoracoplasty. Material and Method: From March 1995 to June 2005, modified thoracoplasty following or concomitant with pulmonary resection was performed in 20 patients out of a total of 298 pulmonary resections for closing air leaks and for treating persistent pleural space following pulmonary resections, and to tailor the thoracic cavity to accept a diminished lung volume. Of the 20 patients, 14 patients had tailoring thoracoplasty performed concomitant with pulmonary resection, and the remaining 6 patients also had tailoring thoracoplasty performed following pulmonary resection. The subjects ages ranged from 24 to 77 (mean $59.1{\pm}6.4$) and a male preponderance was noted (17 : 3); the number of left and right surgeries was equal. The preoperative primary underlying diseases were lung cancer in 7 patients, pneumothorax with giant bullous change in 6 patients, bronchiectasis in 2 patients, previous pulmonary tuberculosis associated with aspergilloma in 2 patients, empyema with fibrothorax in 2 patients and multiple lung abscesses & destruction due to previous trauma in 1 patient. The operative methods were apicolysis and subperiosteal removal of the 2nd, 3rd and 4th ribs (the costochondral junction to the posterior portions of the ribs) with preservation of the first rib and compression of the anterior chest via cotton bags and elastic bandages. Result: The mean duration of the air leaks after thoracoplasty was $1.6{\pm}0.2$ days (range: $0{\sim}7$ days) and the mean duration of an indwelling chest tube was 7 days (range: $5{\sim}11$ days); the mean duration of hospitalization was $19.2{\pm}2.8$ days (range: $8{\sim}47$ days). The postoperative complications were wound infection (2) and pneumonia (2); reoperation was done due to bleeding (1) in one patient who underwent concomitant thoracoplasty and there was 1 case of wound infection (1) after postresection thoracoplasty. The mortality was 1 patient in the early phase and 4 patients in the late phase. Conclusion: We conclude that tailoring thoracoplasty may be performed to close anticipated persistent pleural spaces and to accommodate the diminished lung volume with acceptable cosmetic results when this procedure is combined with pulmonary resection in selected patients.

The Satisfaction Survey of Users and Patients on the Developed Disposable Tourniquet (개발한 일회용 지혈대의 사용자 및 환자 만족도 조사)

  • Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.615-622
    • /
    • 2016
  • The 18~20G needle is used to computer tomography (CT) contrast examination. Therefore, a patient has to apply a self-administering hemostasis (conventional method: CM) and often experience bleeding in the course. Thus, we developed the new disposable transparent tourniquet (TT) for reducing. This study was to compare the usefulness between the proposed transparent tourniquet and the existing hemostatic methods. A Satisfaction survey was conducted by 50 patients and 25nurses. The survey contained the satisfaction of the convenience, safety, sanitation, and wearing sensation of transparent tourniquet. We employed face-to-face interview on 5 points likert scales. And Chi-square, paired T-test were used for the statistics verification. As for the patients, the satisfaction levels were measured for each category with the gender, age. Patients evaluation, overall satisfaction high average sore used TT and there were statistical significance by paired T-test(p<0.05). The following is the average satisfaction level for each category: $4.4{\pm}0.53$ in; $4.28{\pm}0.57$ in safety; $4.52{\pm}0.54$ in sanitation; $4.16{\pm}0.54$ in wearing sensation. So the overall satisfaction level is measured at $4.34{\pm}0.51$. As for the nurses, CT work experience and the current satisfaction with tourniquet were counted as variables. The satisfaction level for each category is: $3.8{\pm}0.7$ in; $3.6{\pm}0.68$ in safety; $3.4{\pm}0.5$ in sanitation; $3.9{\pm}0.49$ in hemostasis. The overall satisfaction level is $3.8{\pm}0.3$. Patients' satisfaction levels were very high with little difference among variables. Nurses' satisfaction levels were different with the TT depending on their work experience but their overall satisfaction was high. This TT will be a starting point to minimizing patient's inconvenience and more studies are necessary to enhance their satisfaction.

Histological Analysis of Autologous Pericardial Tissue Used as a Small-Diameter Arterial Graft (소구경 동맥이식편으로 사용한 자가심란의 조직학적 분식)

  • Yang Ji-Hyuk;Sung Sang-Hyun;Kim Won-Gon
    • Journal of Chest Surgery
    • /
    • v.39 no.4 s.261
    • /
    • pp.261-268
    • /
    • 2006
  • Background: Current vascular prostheses are still inadequate for reconstruction of small-diameter vessels. Autologous pericardium can be a good alternative for this purpose as it already possesses good blood compatibility and shows a mechanical behavior similar to that of natural arteries. However, the clinical use of autologous pericardial tissue as a small-diameter vascular graft has limitations due to mixed outcomes from uncertain biological behavior and difficulty to gain reliable patency results in animal experiments. To study this issue, we implanted fresh and glutaraldehyde-treated autologous pericardium as small-diameter arterial grafts in dogs, and compared their time-related changes histologically. Material and Method: As a form of 5mm-diameter arterial graft, one pair of autologous pericardial tissue was used for comparison between the glutaraldehyde-treated and the glutaraldehyde-untreated grafts in the bilateral carotid arteries in the same dog. The patency of the grafts were evaluated at regular intervals with Doppler ultrasonography. After the predetermined periods of 3 days, 2 weeks, 1 month, 3 months and 6 months, the grafts in each animal were explanted. The retrieved grafts were processed for light and electron microscopic analyses following gross observation. Result: Of 7 animals, 2 were excluded from the study because one died postoperatively due to bleeding and the other was documented as one side of the grafts being obstructed. All 10 grafts in the remaining 5 dogs were patent. Grossly, a variable degree of thromboses were observed in the luminal surfaces of the grafts at 3 days and 2 weeks, despite good patency. Pseudointimal smooth blood-contacting surfaces were developed in the grafts at f month and later. By light microscopy, mesothelial cell layers of the pericardial tissue were absent in all explanted grafts. Newly formed endothelial cell layers on the blood-contacting surface were observed in both the glutaraldehyde-treated and fresh grafts at 3 months and later. The collagen fibers became degraded by fragmentation in the fresh graft at 1 month and In the glutaraldehyde-treated graft at 3 months. At 6 months, the collagen layers were no longer visible in either the glutaraldehyde-treated or fresh grafts. By electron microscopy, a greater amount of coarse fibrin fibers were observed in the fresh grafts than in the glutaraldehyde-treated grafts and, more compact and well-arrayed layers were observed in the glutaraldehyde-treated grafts than in the fresh grafts. Conclusion: The glutaraldehyde-treated small-diameter pericardial arterial grafts showed a better endothelialization of the blood-contacting surface and a slower fragmentation of the collagen layers than the fresh grafts, although it has yet to be proven whether these differences are so significant as to affect the patency results between the groups.

Early Clinical Experience in Aortic Valve Replacement Using On-X$^{circledR}$Prosthetic Heart Valve (On-X$^{circledR}$ 기계판막을 이용한 대동맥판 치환술의 조기 임상 경험)

  • 안병희;전준경;류상완;최용선;김병표;홍성범;박종춘;김상형
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.651-658
    • /
    • 2003
  • Since the first implanted in September 1997, the use of On-X prosthetic heart valve has been increasing around in the world. This study was designed to assess the feasibility, safety, and the postoperative hemodynamics with this new valve in clinical setting. Material and Method: The current study was carried out on 52 patients undergoing aortic valve replacement with this prosthesis between April 1999 to August 2002 at Chonnam National University Hospital to evaluate the surgical results. 52% of the patients were male and the average age at implant was 50$\pm$13 years. The study followed the guidelines of the AATS/STS. Preoperatively, 32(61.5%) patients were in NYHA functional class III or IV and 2 patients had previous aortic valve surgery. Concomitant cardiac surgery was performed in 71.1%. The implanted valve sizes were 19 mm in 13 patients, 21 mm in 26, 23 mm in 10 and 25 mm in 3, respectively. Mean follow-up was 16.6$\pm$10.5 months (1∼39 months). Echocardiographic assessment was performed pre- and immediate postoperatively, as well as 3, 6, 12 months after surgery, evaluating pressure loss and regression of left ventricular hypertrophy. Result: Mean cardiopulmonary bypass time was 191$\pm$94.7 minutes with an aortic cross-clamp time of 142$\pm$51.7 minutes. There was no early and late mortality, Freedom from adverse events at 1 year in the study were as follows: thromboembolism, 95.6$\pm$6%; bleeding events, 90.2$\pm$4%; paravalvular leakage 92.3$\pm$4%; and overall valve-related morbidity at 1 year was 76.6$\pm$3%. There were no cases of valve thrombosis, prosthetic valve endocarditis and structural or non-structural failure. Left ventricular function at 12 months after surgery (EF=62.7$\pm$9.8%) revealed a statistically significant improvement compared to preoperative investigation (EF=55.8$\pm$15.9%, p=0.006). Left ventricular mass index was 247.3$\pm$122.3 g/$m^2$ on preoperative echocardiographic study, but regressed to 155.5$\pm$58.2 g/$m^2$ at postoperative 1 year (p=0.002). Over the follow-up period a further decrease of peak transvalvular gradients was observed in all patients: 62.5$\pm$38.0 mmHg on preoperative assessment, 18.2$\pm$6.8 mmHg at immediate postoperative period (p < 0.0001), 7.6$\pm$5.09 mmHg (p<0.0001) at 6 month, 18.0$\pm$10.8 mmHg (p<0.0001) at 1 year. Conclusion: The On-X prosthetic heart valve performs satisfactorily in the first 1 year period. Clinical outcome by examining NYHA functional classification revealed especially good results. Effective regression of left ventricular hypertrophy and statistically significant decrease of transvalvular gradient were observed over the first year, but longer-term follow-up of this patient group is needed to establish the expected rates for late valve-related events as well as the long-term clinical efficacy of this valve.