• 제목/요약/키워드: Curing Method

검색결과 1,078건 처리시간 0.023초

이론공극율, 골재입도 및 양생방법이 포러스콘크리트의 강도 및 투수성능에 미치는 영향 (Influence of Theoretical Void Ratio, Grading of Aggregate and Curing Method on Strength and Water Permeability of Porous Concrete)

  • 김재환;유범재;최세진;백용관;박정호;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.373-378
    • /
    • 2000
  • The objective of this study was to investigate the influence the influence of theoretical void ratio(T.V.R), grading of aggregate and curing method on the strength and water permeability of porous concrete, and the reduction proportion of water permeability by these factors. The results of the study showed that its strength and water permeability were greatly depended on the T.V.R and grading of aggregate, but didn't on the curing method. And, when the T.V.R and grading of aggregate were increased, the reduction proportion of water permeability was small. As the relation ship between its physical properties and non-destruction test values was very high, its use for the estimation of the physical properties will be useful.

  • PDF

2중 버블시트를 이용한 한랭기 콘크리트의 단열양생공법 현장적용 (Field Construction Applying the Insulating Method of Moderate-Cold Weather Concreting Using Double Bubble Sheets)

  • 김종;김종백;전충근;신동안;오선교;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.29-32
    • /
    • 2006
  • Experimental test results of field construction, Cheongju University Educational Liberal Art Building, applying the insulating curing method on slab concrete showed that the quality of concrete in fresh and hardened state satisfied all target values. Temperature history of slab concrete in A and B area secured more than $7.8{\sim}9.2^{\circ}C$ higher than outside atmosphere. After completing certain curing period of time on the surface of the structure, crack occurrence was not found. It is concluded that the preventing vaporization of moisture by the insulating curing method reduces plastic and drying shrinkage as welt as improves durability.

  • PDF

저온기 콘크리트의 조기압축강도 확보방안에 관한 연구 (A Study on Securing Early Strength of Concrete in a Low Temperature Time)

  • 이도범;최일호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.273-276
    • /
    • 2004
  • Recently. cold weather constructions were popularized because of the importance of construction term. The special method about mix design and curing of concrete was being planned to conduct cold weather constructions, but these method were not considered in a low temperature time. A Strength revelation of concrete is delayed in a curing condition of low temperature. If a construction was loaded in this case, cracks or remaining deformations are generated in a construction. So, a strength revelation characteristic in early age was investigated to secure early strength of concrete in curing condition of a low temperature. In this study, the method about concrete mix design was presented to secure construction safety in a low temperature time.

  • PDF

두꺼운 복합재료 실린더의 생산 및 열응력 해석 (Continuous Curing and Residual Stresses of Thick Composite Cylinders)

  • 김철
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 춘계학술발표대회 논문집
    • /
    • pp.49-52
    • /
    • 2000
  • A new composite manufacturing technique which combines winding and curing together is studied and analyzed. This method is especially suited to the manufacture of thick composite materials in which thermal spiking is a common problem. An experimental apparatus was designed and built for use with a filament winder to continuously cure a thick composite cylinder. A hoop-wound composite cylinder with 152 mm wall thickness was manufactured and embedded thermocouples and strain gages were monitored throughout the cure process. The experimental data were compared with analytical results.

  • PDF

광조사 방법에 따른 복합레진의 중합수축에 관한 연구 (A STUDY ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN ACCORDING TO VARIOUS LIGHT-CURING METHODS)

  • 권오진;김종수;권순원
    • 대한소아치과학회지
    • /
    • 제30권1호
    • /
    • pp.102-109
    • /
    • 2003
  • 본 연구는 중합수축을 줄이기 위해 개발된 2단계 광조사법을 사용하여 복합레진의 중합시 발생하는 수축양상을 스트레인 게이지법(strain gauge method)으로 측정해 보고, 중합도의 비교를 위해 미세경도를 측정해 본 다음 이 결과를 기존의 광조사법과 비교해 보고자 하는 것이었다. 내경 6mm, 높이 2mm의 아크릴 주형에 복합레진인 $Z100^{TM}$(3M, USA)을 충전하였고 Curing light 2500(3M, USA)과 Elipar Highlight(ESPE, Germany)의 광조사기를 사용하였다. I 군은 광도가 $450mW/cm^2$인 Curing light 2500으로 40초간 광조사하였고, II 군은 광도가 $650mW/cm^2$인 Elipar Highlight로 40초간 광조사하였으며, III 군은 Elipar Highlight의 2단계 중합 방법을 이용하여 초기 10초간은 $150mW/cm^2$로, 나머지 30초간은 $650mW/cm^2$의 광도로 조사하였다. 스트레인 게이지법을 이용하여 광조사 후 1초 간격으로 10분간 선중합 수축률(linear polymerization shrinkage)을 측정한 다음 그래프로 분석하였고, 중합 1분 후와 10분 후의 선수축률을 측정하여 통계분석하였으며 미세경도기를 사용하여 중합 24시간 후의 각 군의 미세경도를 측정하여 통계분석하였다. 중합수축 양상을 관찰해 본 결과 각 군에서 모두 중합 초기에 일시적인 재료의 팽창을 나타내었고, 그 후 약 1분간은 수축량이 급격히 증가하다가 증가의 폭이 점차 감소하는 양상을 보였다. 전반적으로 2단계 광조사법을 사용한 III 군에서 수축률이 낮게 나타났다. 중합 후 1분과 10분에서의 선수축률을 비교해 본 결과 통상적인 광조사법을 사용한 I 군과 II 군에 비해 2단계 광조사법을 사용한 III군에서 유의하게 낮은 수축률을 나타내었다(p<0.05). 미세경도 측정결과 상면과 하면에서 모두 각 군간에 유의한 차이를 발견할 수 없었다.

  • PDF

매스콘크리트의 타설높이 및 양생조건에 따른 온도균열 저감 방안에 관한 연구 (Thermal Crack Control of Mass Concrete by Concrete Placing Height and Curing Method)

  • 민병소;신길수;김대권;이현희;신성우;이광수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.369-376
    • /
    • 2001
  • As many studies have performed to reduce thermal cracking in mass concrete, it is already prepared against thermal cracking, we can find many plans against thermal cracking in several reference book. But it needs practical guidelines to be available in construction site. In this study to establish control method of thermal cracking in mass concrete, tests which have factors of placing thickness and curing method of concrete are performed.

  • PDF

광중합 복합레진 수복시 여러 광조사 방법에 따른 미세변연누출에 관한 연구 (MICROLEAKAGE OF CL V COMPOSITE RESTORATIONS USING VARIOUS LIGHT CURING METHODS)

  • 양철영;유현미;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.299-308
    • /
    • 2000
  • The purpose of this in vitro study was to evaluate the microleakage of 5 curing methods in class V composite restorations which are composed of two-step light curing, pulse-delay cure, low curing-light intensity, moderate curing-light intensity and high curing-light intensity. In this study, class V cavities were prepared on buccal and lingual surfaces of 50 extracted human upper or lower molars on cementum margin. Single Bond adhesive and Z-100 shade A2 were applied for each group following the manufacture's instruction. The experimental teeth were randomly divided into 5 groups of 10 samples (20 surfaces) each. Group 1: two-step light curing; Group 2: pulse-delay cure; Group 3: low curing-light intensity; Group 4: moderate curing-light intensity; Group 5: high curing-light intensity. After 500 thermocycling between $5^{\circ}C$ and $55^{\circ}C$, the 60 teeth were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimen was then observed with a stereomicroscope at ${\times}20$. The composite resin/tooth interfaces were examined under Scanning Electron Microscopy. The results were statistically analyzed using the Kruskal-Wallis One Way ANOVA and Dunn's Method. The results of this study were as follows. 1. In all groups, the leakage values seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 2. No group in this study showed significant differences in leakage values at both the enamel and the dentin margins(P<0.05). 3. In all groups, the gaps seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 4. The gaps in this study showed significant differences and two-step light-curing and low curing-light intensity produced significant less gap than high curing-light intensity(P<0.05).

  • PDF

LED와 플라즈마 광원의 완속기시 광중합 방식이 복합레진의 수축응력에 미치는 영향 (EFFECT OF SOFT-START CURING ON THE CONTRACTION STRESS OF COMPOSITE RESIN RESTORATION POLYMERIZED WITH LED AND PLASMA CURING UNIT)

  • 정양석;이난영;이상호
    • 대한소아치과학회지
    • /
    • 제34권4호
    • /
    • pp.623-631
    • /
    • 2007
  • 본 연구는 LED와 플라즈마 광원의 복합레진의 중합시 완속기시 중합방식(soft-start curing)이 수축응력에 미치는 효과를 비교, 평가하고자 하였다. 할로겐 광원으로 40초간 조사하여 복합레진을 중합한 경우와 LED와 플라즈마 광원의 단일광도 중합방식과 완속기시 중합방식으로 할로겐 40초 동안의 광에너지와 총량이 동일하도록 조사시간을 설정하였고 수축응력은 스트레인 게이지(Strain gauge)를 사용하여 측정하였다. 발생되는 수축응력을 비교, 분석 및 평가한 결과 다음과 같은 결론을 얻었다. 1. 모든 군에서 중합 후 200초까지 수축응력이 급격하게 증가하였으나 이후 마지막 측정시간인 800초까지 완만한 증가를 보였다(P<0.05). 2. LED와 플라즈마 광원의 완속기시 중합방법이 단일광도 중합방법에 비해 수축응력이 낮게 나타났다(P<0.05). 3. 할로겐 광원과 LED와 플라즈마 광원의 완속기시 중합의 수축응력 비교에는 유의차가 없었다(P>0.05). 완속기시 중합 방식을 사용할 경우 단일광도 중합 방식보다 수축응력을 감소시킬 수 있어 임상적으로 고광도 광원인 LED와 플라즈마 광원의 경우 완속기시 중합 방식의 사용이 유리하다고 보여진다. 그러나 완속기시 중합시 불충분한 중합을 방지하기 위해서는 완속기시를 보완하는 추가적인 중합시간이 요구될 것으로 사료된다.

  • PDF

상아질 접착제의 중합 시간 조절에 따른 복합레진의 중합 수축 방향의 변화 (THE EFFECT OF ADHESIVE CURING TIMING ON THE DIRECTION OF POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN)

  • 배지현;오명환;김창근;손호현;엄정문;조병훈;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.316-325
    • /
    • 2001
  • The purpose of this study was to evaluate the effect of adhesive curing timing on the direction of polymerization shrinkage of light-curing composite resin. In this study, the curing times of adhesive and composite resin were measured by differential scanning calorimeter(DSC). 28 extracted human molars were embedded in clear resin and box-type cavities were prepared. Based on DSC data, the experimental teeth were divided into 4 groups. Group 1: no bond; Group 2: late curing; Group 3: Intermediate curing; Group 4: Early curing. After treating with adhesive, the buccal cavities were filled with Z-100 hybrid composite resin and the lingual ones were filled with AEliteflo flowable composite resin. The depressions at the surface were measured by surface profilometer, then the specimens were embedded in clear resin and sectioned. Impressions were obtained and used to get epoxy resin replicas. The epoxy replicas were gold-coated and observed under SEM. Average Maximum Gap(AMG), Gap Proportion(GP), Average Marginal Index(AMI) were used to compare the shrinkage gap of each group. The results were statistically analyzed using the Kruskal-Wallis One Way ANOVA, Student-Newman-Keuls method. The results of this study were as follows. 1. Average Maximum Gap, Gap Proportion, Average Marginal Index and depression at the surface or Z-100 hybride composite resin were smaller than those of AEliteflo flowable composite resin(P<0.05). 2. When the bonding between composite resin and tooth structure was strong, the shrinkage gap was small, and depression at the surface was deep(P<0.05). 3. In the well-bonded group, light-curing composite resin shrank toward bonded cavity wall, not toward light source. The result suggested that the direction of polymerization shrinkage was affected by the quality of bonding in the dentin-resin interface. The strong was the bonding between composite resin and tooth structure, the smaller was the gap and the deeper was the depression at the surface. Then the flow to compensate the polymerization shrinkage proceeded from surface to bonded cavity wall.

  • PDF

LED용 실리콘 봉지재의 경화방법이 신뢰성에 미치는 영향 (Effect of Curing Method on the Reliability of Silicone Encapsulant for Light Emitting Diode)

  • 김완호;장민석;강영래;김기현;송상빈;여인선;김재필
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.844-848
    • /
    • 2012
  • Encapsulant curing in terms of convection oven leads to thermal induced stress due to nonuniform thermal conductivity in LED package. We have adopted infrared (IR) light for silicone curing in order to release the stress. The light uniformity irradiated on an encapsulant surface is confirmed to be uniform by optical simulation. Shear strength of die paste using IR compared to convection oven is increased 19.2% at the same curing time, which indicates curing time can be shortened. The indentation depth difference between center and edge of silicone encapsulant in terms of convection oven and IR are 14.8% and 3.4%, respectively. Curing by IR also shows 2.3% better radiant flux persistency rate of LED at $85^{\circ}C$ after 1,000 h reliability test compared to convection curing.