• 제목/요약/키워드: Curing Method

검색결과 1,071건 처리시간 0.028초

수종의 레진 시멘트의 용해도와 수분흡착에 관한 연구 (A STUDY ON THE SOLUBILITY AND THE WATER SORPTION OF VARIOUS RESIN CEMENTS)

  • 황유진;조인호;임주환;임헌송
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.1-14
    • /
    • 2005
  • Statement of problem. Among the physical properties of adhesion luting cement, the aspect that requires the most important factor is the degree of solubility and water sorption. Dissolution or an inadequate due to excessive water sorption inside the oral cavity compromises the while concurrently increasing the susceptibility to secondary dental caries. Susceptibility to dissolution and difficulty of removing remnant cement from the gingival sulcus have hindered the use of dental resin cement in the clinical practice, but the improved characteristics of newer generation resin cements have interest in and enabled resin cements to be widely used in adhesion of fixed prosthesis, such as laminate veneers and all-ceramic crowns. Purpose. The purpose of this study is to compare and analyze the degrees of solubility and water sorption of a variety of resin cements widely used for clinical purposes with different curing methods. Material and methods. Self-curing resin cements, $Avanto^{(R)}$, $C&B^{TM}$ CEMENT and Superbond C&B cements comprised group 1, 2 and 3. The dual-curing resin cements $Panavian^{TM}$ F, $Calibra^{(R)}$ and $Variolink^{(R)}$ II were divided into groups 4, 5, and 6, respectively. The investigation was carried out using disc-shaped specimens as specified by ANSI/ADA Specification No. 27. The degree of water sorption, water solubility and lactic acid solubility of each test group was analyzed statistically leading to the following conclusion. Results. The degree of water sorption was shown to increase in the following order : group 6, 5, 4, 2, 1 and 3. There were significant differences between the water sorption of each group. Results of the degree of water solubility were shown to increase in the following order : group 6, 5, 4, 2, 1 and 3. Statistically significant differences were found between each group, with the exception of groups 1 and 3. Finally, the degree of lactic acid solubility was found to increase in the following order : group 6,5,4,2,3 and 1. Significant differences were found between each group. In general dual-curing resin cements displayed substantially lower values than self-curing resin cements with regard to water sorption, water solubility, and lactic acid solubility. Conclusions. From the results of this study, dual-curing resin cements show a significantly lower degree of water sorption and solubility than their self-curing counterparts. Clinically, when selecting resin cements, the product with a lower degree of water sorption and solubility are preferred. The results of this study indicate that the use-of dual-curing resin cements is preferable to self-curing cements.

Investigated properties of Low temperature curing Ag Paste for Silicon Hetero-junction Solar Cell

  • Oh, Donghyun;Jeon, Minhan;Kang, Jiwoon;Shim, Gyeongbae;Park, Cheolmin;Lee, Youngseok;Kim, Hyunhoo;Yi, Junsin
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.160-160
    • /
    • 2016
  • In this study, we applied the low temperature curing Ag paste to replace PVD System. The electrode formation of low temperature curing Ag paste for silicon Hetero-junction solar cells is important for improving device characteristics such as adhesion, contact resistance, fill factor and conversion efficiency. The low temperature curing Ag paste is composed various additives such as solvent, various organic materials, polymer, and binder. it depends on the curing temperature conditions. The adhesion of the low temperature curing Ag paste was decided by scratch test. The specific contact resistance was measured using the transmission line method. All of the Ag electrodes were experimented at various curing temperatures within the temperature range of $160^{\circ}C-240^{\circ}C$, at $20^{\circ}C$ intervals. The curing time was also changed by varying the conditions of 10-50min. In the optimum curing temperature $200^{\circ}C$ and for 20 min, the measured contact resistance is $19.61m{\Omega}cm^2$. Over temperature $240^{\circ}C$, confirmed bad contact characteristic. We obtained photovoltaic parameter of the industrial size such as Fill Factor (FF), current density (Jsc), open-circuit voltage (Voc) and convert efficiency of up to 76.2%, 38.1 mA/cm2, 646 mV and 18.3%, respectively.

  • PDF

버어리종담배 대말림시 백화엽발생방지 및 건조기간단축에 관한 연구 (Studies on the Method of Reducing of the Photobleaching Leaves and Shortening the Curing Period in Burley Tobacco Stalk Curing)

  • 김상범;백기현;추홍구
    • 한국작물학회지
    • /
    • 제28권2호
    • /
    • pp.252-257
    • /
    • 1983
  • 버어리종 대말림시 백화엽발생을 방지하고 건조기간을 단축하기 위하여 시험을 수행하였던 바, 결과를 요약하면 다음과 같다. 1. 건조실내 온도는 흑색비닐피복구 및 환기창이용구가 관행구보다 $3^{\circ}C$정도 높았으며, 탈수속도는 환기창이용구가 훨씬 빨랐다. 2. 백화엽발생율은 완전대말림구가 높았고, 지면을 30cm 판 처리가 낮았다. 3. 수량감소는 완전대말림구가 컸다. 4. 품질 및 대금은 환기창이용구 및 지면을 30cm판 구가 높았다. 5. 물리성은 줄말림용 차광막처리가 비교적 양호하였다. 6. 백화엽발생을 억제하기 위하여는 첫째, 본포에서 치마름엽과 과숙엽을 방지하고, 둘째, 하위엽은 1-2회 수확한 후 대베기를 실시하며, 셋째, 갈변후에는 건조기간을 단축시키기 위한 온습도관리에 유의해야 할 것으로 생각된다. 7. 버어리종 담배의 물리성을 향상시키면서 건조중 백화의 원인이 되는 산소 및 수분과의 반응을 억제시킬 수 있는 방법에 대하여는 앞으로 더욱 검토가 요구된다.

  • PDF

Curing Both Virulent Mega-Plasmids from Bacillus anthracis Wild-Type Strain A16 Simultaneously Using Plasmid Incompatibility

  • Wang, Dongshu;Gao, Zhiqi;Wang, Huagui;Feng, Erling;Zhu, Li;Liu, Xiankai;Wang, Hengliang
    • Journal of Microbiology and Biotechnology
    • /
    • 제25권10호
    • /
    • pp.1614-1620
    • /
    • 2015
  • Plasmid-cured derivative strains of Bacillus anthracis are frequently used in laboratory studies. Plasmid incompatibility, which does not increase the risk of chromosomal mutation, is a useful method for plasmid curing. However, in bacteria containing multiple plasmids, it often requires the sequential introduction of multiple, specific incompatibility plasmids. This lengthy process renders the traditional plasmid incompatibility method inefficient and mutation-prone. In this study, we successfully cured plasmids pXO1 and pXO2 from B. anthracis A16 simultaneously using only one recombinant incompatible plasmid, pKORT, to obtain a plasmid-free strain, designated A16DD. This method may also be useful for the simultaneous, one-step curing of multiple plasmids from other bacteria, including Bacillus thuringiensis and Yersinia pestis.

복합보온양생 방법이 극저온 조건하 플라이애시 치환 콘크리트의 온도이력에 미치는 영향 (The Effect of Heat Curing Methods on the Temperature History of the Fly Ash Concrete Subjected to Extremely Low Temperature)

  • 한민철;손호정
    • 한국건설순환자원학회논문집
    • /
    • 제7권3호
    • /
    • pp.85-90
    • /
    • 2012
  • In this study, temperature profile of the fly ash concrete were studied in accordance with the change of heating curing method combination for the slab concrete in order to develop efficient protection method of the concrete subjected to $-20^{\circ}C$. The slab concretes with the size of $1200mm{\times}600mm{\times}200mm$ were fabricated with W/B of 50% and exposed to $-20^{\circ}C$ for 7 days. Five different combinations of heat curing methods were applied to the slab concrete specimen; two combinations of heat supplying by electrical heater and surface heat insulation material such as polyethylene film and quadrupled layer bubble sheet based on heat enclosure installment; three combinations of heating coil embedment and surface heat insulation materials such as polyethylene film, sawdust and quadrupled layer bubble sheet based on heat enclosure installment. Test results showed that by applying both heating coil and bubble sheet and heat enclosure, the concrete exposed to $-20^{\circ}C$ can be effectively protected from early-age frost damage.

  • PDF

폐식용유 혼입 및 양생방법에 따른 순환잔골재 사용 고로슬래그 벽돌의 품질특성 (Quality Properties of Blast Furnace Slag Brick Using the Recycled Fine Aggregates Depending on Waste Oil and Curing Method)

  • 박경택;손호정;김대건;김복규;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.61-62
    • /
    • 2011
  • This study reviewed the effect of W/B, WO and curing method on the quality properties of RA using the BS brick under the zero cement condition. compressive strength was found to show an increasing trend as W/B increased, but to show a improvement in case steam curing was conducted, showing a higher increase at 1 day age in comparison with 7 day age. In addition, the compressive strength on the mixing of WO didn't show any specific trend. The absorption tended to decrease as W/B increased and met the less than 10% regulation value at 30~35% W/B in case WO was used, there appeared a decrease attributable to capillary pore filling effect due to saponification. On the other hand, compressive strength increases, th absorption showed a gradually decreasing tendency.

  • PDF

50, 60℃ 온수양생을 이용한 초고강도 콘크리트의 강도 조기 평가 (A Study on the Early Evaluation of Compressive Strength of Ultra-High Strength Concrete Using 50, 60℃ Warm Water Curing)

  • 이종석;명로언;백민수;공민호;하정수;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.73-75
    • /
    • 2011
  • In this study, prediction of later-age compressive strength of ultra-high strength concrete, based on the accelerated strength of concrete cured in 50, 60℃ warm water was investigated. W/B of 32, 23.5, 19% 3 levels were examined. And the specimens were cured in 50, 60℃ warm water. The results showed reliable accuracy by regression relation between 28day strength cured by standard curing method and accelerated strength of the concrete cured in warm water. And the specimens cured in 50, 60℃ showed more high strength development. So 60℃ curing could be considered in order to reduce the measurement error. As a result, the feasibility of 50, 60℃ warm water curing method at high strength level was confirmed.

  • PDF

소생재 도포 후 소생온도 및 양생방법 변화가 Fly Ash 다량치환 모르타르의 압축강도에 미치는 영향 (Effects of Changes in Resuscitation Temperature and Curing Method on the Compressive Strength of the Large Volume Mortar of Fly Ash after Application of the Resuscitation Material)

  • 최윤호;한준희;이영준;현승용;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.139-140
    • /
    • 2019
  • In this study, we conducted a comparative analysis of the effects of resuscitation after the re-application of mortar with much FA replacement on the degree of resuscitation. Results When NaOH was applied to the top of the mortar where 90% of FA was replaced, and maintained for 24 hours, the degree of resuscitation at $40^{\circ}C$ was completely improved. However, when medium curing was carried out, it showed a higher degree of compression than water or lapping curing at 10 MPa in 28 days. The degree of resuscitation on the 28th day was revived from around 10% of the normal level to about 20~30%, and it was analyzed that it was difficult to achieve the OPC reduction by any method.

  • PDF

이중 버블시트를 이용한 단열양생공법의 한중시공 적용 사례 (Application of Insulation Curing Method with Double Bubble Sheets Subjected to Cold Weather)

  • 홍석민;이충섭;김종;전충근;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.1001-1004
    • /
    • 2008
  • 본 연구는 한중환경에서 이중 버블시트를 이용한 단열보온 양생 공법을 슬래브 및 매스 콘크리트에 활용한 결과를 검토한 것이다. 먼저, 이중 버블시트를 적용한 경우 타설 후 2일까지 외기온이 영하$9^{\circ}C$까지 강하하는 경우에도 슬래브콘크리트는 영상 $6^{\circ}C$에서 $10^{\circ}C$이상을 유지하여 초기동해가 방지됨을 알 수 있었고, 매스콘크리트의 경우에는 중심부 최고온도와 표층부 최고온도차이가 $6^{\circ}C$이하로 나타나 내부구속에 의한 수화열 균열은 발생하지 않은 것으로 판단된다. 본 현장에 적용된 이중버블시트를 이용한 단열보온양생 공법은 동절기 영하에서도 안정된 양생온도 관리로 초기동해를 방지할 수 있었고, 소요강도를 확보할 수 있었다. 또한, 가시설의 설치 해체 공정을 줄여 공기단축 효과와 인건비절감등 양생비용의 감소로써 한중콘크리트의 품질확보에 우수한 효과가 있음과 동시에 단열 양생공법의 경제성이 입증되었다.

  • PDF

이중버블시트의 포설방법에 따른 콘크리트의 온도이력특성 (Temperature History of Concrete According to the Covering Method of Double Layer Bubble Sheet)

  • 백대현;손호정;홍석민;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 1부
    • /
    • pp.71-72
    • /
    • 2010
  • The study is compared temperature history and strength of concrete followed by covering method of insulation curing of cold weather concrete with double bubble sheet. The results were as follows. First of all, in temperature history of concrete, the internal temperature of concrete fell down to $0^{\circ}C$ before/after 60 hours, having nothing to do with covering method. The study could see that, when sheet was isolated, it fell down to low temperature quickly in early curing. When the study measured compressive strength of core specimen, there were no large differences among placing methods. However, compressive strength fell down in all ages when sheet was isolated.

  • PDF