• Title/Summary/Keyword: Cu removal efficiency

Search Result 208, Processing Time 0.024 seconds

Removal of Heavy Metals Through Conventional Water Treatment Processes (정수처리 과정에서의 중금속제거에 관한 연구)

  • 김중구;고영송;남상호
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.4
    • /
    • pp.36-44
    • /
    • 1994
  • A study was carried out in order to investigate the removal efficiencies and removal characteristics of heaw metals such as Pb, Cd, Cr, Cu in raw water by one of conventional water treatment processes. The coagulants used in this study were Alum and PAC. Three kinds of water samples were provided: kaolin water, kaolin water mixed with humic acid and raw water from Han River mixed with suspended matter deposited on raw water inlet pipe. Heaw metals were added to the water samples with their respective turbidity, and jar tests were performed. In the results from heaw metal removal studies, lead might be adsorbed or exchanged on the particle surface (SS) rather than react with organic matter added. Cadmium was affected on the dissolved organic matter. Chromium was affected by the both dissolved organic matter and SS concentration, and the restabilization and the enmeshment appeared at moderate (50~80 NTU) and high (100 NTU) turbidity as defined in this experimenL The removal efficiency of copper was relatively little affected by the dissolved organic matter but by SS concentration in comparison with other heavy metals. In these studies as to the raw water turbidities and concentration of heaw metals, it is proved out that the removal efficiency on heaw metals in both cases of PAC and Alum as coagulants was not significantly different.

  • PDF

Assessment of kinetics behavior of electrocoagulation process for the removal of suspended solids and metals from synthetic water

  • Singh, Hariraj;Mishra, Brijesh Kumar
    • Environmental Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.141-148
    • /
    • 2017
  • Globalization, industrialization, mining, and uncontrolled population growth have fostered a shortage of potable water. Therefore, it has become imperative to understand an effective and reasonable water purification technique. A renewed interest in electrocoagulation (EC) has been spurred by the search for reliable, cost-effective, water-treatment processes. This paper has elucidated a technical approach for getting rid of heavy metals and total suspended solids (TSS) from synthetic water using an aluminum electrode. The effect of operational parameters, such as current density, inter-electrode distance, operating time, and pH, were studied and evaluated for maximum efficiency. This study corroborates the correlation between current density and removal efficiency. Neutral pH and a low electrode gap have been found to aid the efficacy of the EC setup. The outcome indicates that a maximum TSS removal efficiency of 76.6% occurred at a current density of $5.3mA/cm^2$ during a contact time of 30 min. In the case of heavy metals remediation, 40 min of process time exhibited extremely reduced rates of 99%, 59.2%, and 82.1%, for Cu, Cr, and Zn, respectively. Moreover, kinetic study has also demonstrated that pollutants removal follows first-and second-order model with current density and EC time being dependent.

Remediation of Mine Tailings Contaminated with Arsenic and Heavy Metals: Removal of Arsenic by Soil Washing (비소와 중금속으로 오염된 광미의 정화: 토양세척에 의한 비소 제거)

  • Kim, Tae-Suk;Kim, Myoung-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.8
    • /
    • pp.808-816
    • /
    • 2008
  • In the present paper, a study has been performed on remediating mine tailings around abandoned mine contaminated with high concentrations of arsenic and heavy metals using the technique of soil washing. Through the removal experiment of arsenic, the optimal conditions in the type and concentration of washing reagent, mixing ratio of mine tailings and washing reagent, and washing time were derived. Results showed that the most effective washing reagents to remove arsenic from mine tailings were oxalic acid(72% removal efficiency) and phosphoric acid(65%), while the oxalic acid(89%) was the most effective in removing the heavy metals containing Cu. In addition, the most economical and efficient washing concentration was 0.25 M and the most suitable washing time was 30 minutes. The optimal mixing ratio of mine tailings and washing reagent was 1 : 20(mass/vol) from the viewpoint of minimization of wastewater produced after the washing, as well as the washing effectiveness. Although the mixture of washing reagents did not help in removal of arsenic, it could lead to much elevated synergy effect on removing Cu and Zn, compared with the single reagent.

Treatment of Wastewater containing Cu and Ni by Electrolysis (전기분해를 이용한 동과 니켈함유 폐수처리)

  • 김재용;이상희
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.2
    • /
    • pp.47-55
    • /
    • 2001
  • We investigated to find the optimum operation condition of electrolysis which have an influence on removal efficiency of heavy metals. When we experimented the testing wastewaters containing each 250mg/L of Cu and Ni ions, we got the variables like as pH, amount of electrolyte(NaCl), different species of electrode, electrode gap, electric strength, the number of electrodes, after fastening positive electrode plate with Al, Fe, Ti and negative electrode plate with Stainless Steel plate.

  • PDF

Removal of Cu(II) ions by Alginate/Carbon Nanotube/Maghemite Composite Magnetic Beads

  • Jeon, Son-Yeo;Yun, Ju-Mi;Lee, Young-Seak;Kim, Hyung-Il
    • Carbon letters
    • /
    • v.11 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • The composites of alginate, carbon nanotube, and iron(III) oxide were prepared for the removal of heavy metal in aqueous pollutant. Both alginate and carbon nanotube were used as an adsorbent material and iron oxide was introduced for the easy recovery after removal of heavy metal to eliminate the secondary pollution. The morphology of composites was investigated by FE-SEM showing the carbon nanotubes coated with alginate and the iron oxide dispersed in the alginate matrix. The ferromagnetic properties of composites were shown by including iron(III) oxide additive. The copper ion removal was investigated with ICP AES. The copper ion removal efficiency increased greatly over 60% by using alginate-carbon nanotube composites.

Phosphorus Removal by Aluminium Ion Generated with the Pitting Corrosion of Aluminium (알루미늄의 부식으로 발생한 알루미늄 이온에 의한 인 제거)

  • Cheong Kyung-Hoon;Jung Oh-Jin
    • Journal of Environmental Science International
    • /
    • v.8 no.6
    • /
    • pp.705-710
    • /
    • 1999
  • The fundamental experiments on the phosphorus removal from water were carried out by the batch and continuous reactors which used aluminium and copper plate. In this systems, the phosphorus was removed by aluminium ion generated with the electrochemical interaction (pitting corrosion) of aluminium and copper. In the batch experiments, the efficiencies of phosphorus removal increased when the surfaces of aluminium and copper plate were brushed. The phosphorus removal by aluminium ion was affected the copper plate and NaCI in this system. The optimal pH values were 5 and 6 for the phosphorus removal. The efficiency of phosphorus removal increased with increasing NaCI concentration, surface area of aluminium and copper plate. The $CUSO_4{\cdot}5H_2O$ instead of copper plate could be used as Cu source. The effluent $PO_4-P$ concentration as low as 2 $mg/{\ell}$ could have been obtained during the continuous experiment at HRT of 48 hrs.

  • PDF

Separation of Heavy Metals from Metal-EDTA in Spent Soil Washing Solution by using Na2S (Na2S를 이용한 EDTA 토양세척수로부터의 중금속 분리)

  • Oh, Sanghwa;Shin, Won Sik
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.7
    • /
    • pp.103-111
    • /
    • 2015
  • Soil washing with ethylenediaminetetraacetic acid (EDTA) is highly effective in the remediation of soils contaminated with heavy metals. The EDTA recycling process is a requisite for reducing the operating cost. The applicability of Na2S addition on the precipitation of heavy metals from the spent soil washing solution and thereby recycling of EDTA was investigated. Addition of Na2S into the single metal-EDTA and the mixed metal-EDTA solutions ([Na2S]/[metal-EDTA] ratio = 30, reaction time = 30 min and pH = 7~9) was highly effective in the separation of Cu and Pb from metal-EDTA complexes, but not for Ni. The Zn removal efficiency varied with pH and slightly increased upto 40% as the reaction time increased from 0 to 240 min which was longer than those for Cu and Pb. Ca(OH)2 was subsequently added to induce further precipitation of Zn and Ni and to reduce the Na2S dose. At the [Na2S]/[metal-EDTA] ratio of 10, the removal efficiencies of all heavy metals excluding Ni were above 98% with the dose of Ca(OH)2 at 0.002, 0.006 and 0.008 g into 100 mL of Cu-, Pb- and Zn-EDTA solutions, respectively. However, Ca(OH)2 addition was not effective for Ni-EDTA solution. A further research is needed to improve metal removal efficiency and subsequent EDTA recycling for the real application in field-contaminated soils.

Adsorptive Removal Properties of Heavy Metal Ions By Soils from the Upper Banbyun Stream (반변천 상류 주변 토양의 중금속 이온 흡착제거 특성)

  • Kim, Younjung;Hwang, Haeyeon;Kim, Yunhoi;Ryu, Sanghoon;Baek, Seungcheol;Seo, Eulwon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.2
    • /
    • pp.5-9
    • /
    • 2007
  • This study carried out to investigate the removal capacity of heavy metals such as Cu (II), Zn (II) and Cd (II) dissolved in aqueous solution in the soils collected from Hyeon-Dong (HD), San-seong (SS), Keum-chon (KC) and Keum-Hac (KH) located in the upper Banbyun stream. The pH of all the soils was weak alkali such as 8.8 9.2. According to the analysis of chemical composition of the soils, the amount of $SiO_2$, $AlO_2$ and CaO were similar in all tested soils. However, the amount of $K_2O$, $FeO_3$ and MgO were different from each soil. The XRD measurement with these soils showed that quartz and feldspar were presented in all tested soils, and the distribution of kaoline, illite, montmorillonite, vermiculite and calcite were different from each soil. The results of the removal capacity of heavy metals indicated that all the soils had more than 98% of the removal efficiency of Cu (II), Zn (II) and Cd (II), and among the heavy metals, Cu (II) was removed the most effectively. These results suggested that the soils collected from the upper Banbyun stream have the high removal capacity of heavy metals, and these soils could be used for the banking a river around the abandoned mine area, containing the higher concentrations of heavy metals than the usual stream.

  • PDF

Electrochemical Precipitation Treatment of Copper from an Heavymetal Wastewater (중금속폐수에서 구리의 전기화학적 침전처리)

  • 김재우;이재동;이우식;지은상
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.3
    • /
    • pp.1-6
    • /
    • 1997
  • This research was conducted in the laboratory to investigate an alternative of Copper(Cu) removal from an heavymetal wastewater using the electrochemical precipitation(ECP) process. The ECP unit consisted of an electrolytic cell made of Titanium plate and Steel plate representing anode and cathode. The DC power source applied to the ECP unit had electrical potential(E) of 50$\pm$ 1V, respectively. The synthetic wastewater used in the experiments contained Cu in the 10 mg/l concentration and the electrode separation were 2, 3, 4 cm and the initial pH were 3, 6, 9, 12, and electrolytic concentration were 0.005, 0.0125, 0.025, 0.0375 mole, and the real heavymetal wastewater used in the experiments. From the experiment for removal efficiency according to pH variation, the low pH area doesn't give the coagulation effect by Ti(OH)$_4$ because process interfere with the coagulation and oxidation reaction, therefore the optimum pH was 4-7. The removal rate was 97.75% after the lapse of 30 minutes when copper concentration and electrolytic concentration were respectively 10 mg/l and 0.025 mole. The removal rate was 96.41% after the lapse of 30minutes when the real heavymetal wastewater used. The optimum consumption of power showed 27KWh/m$^3$ when copper concentration, electrolyte concentration and cell potential were respectively 10 mg/l, 0.025 mole and 50$\pm$ 1 Volt.

  • PDF

THE REMOVAL OF HEAVY METALS USING HYDROXYAPATITE

  • Lee, Chan-Ki;Kim, Hae-Suk;Kwon, Jae-Hyuk
    • Environmental Engineering Research
    • /
    • v.10 no.5
    • /
    • pp.205-212
    • /
    • 2005
  • The study was conducted to investigate the removal of heavy metals by using Hydroxyapatite(HAp) made from waste oyster shells and wastewater with high concentration of phosphorus. The maximum calcium concentration for the production of HAp in this study was released up to 361 mg/L at pH of 3 by elution experiments. When the pH was at adjusted 6, the maximum calcium released concentration was 41 mg/L. During the elution experiment, most of the calcium was released within 60 minutes. This reaction occurred at both pH levels of 3 and 6. The result of the XRD analysis for the HAp product used in this study shows the main constituent was HAp, as well as OCP. The pH was 8.6. As the temperature increased, the main constituent did not vary, however its structure was crystallized. When the pH was maintained at 3, the removal efficiency decreased as the heavy metal concentration increased. The order of removal efficiency was as follows: $Fe^{2+}$(92%), $Pb^{2+}$(92%) > $Cu^{2+}$(20%) > $Cd^{2+}$(0%). Most of these products were dissolved and did not produce sludge in the course of heavy metals removal. As the heavy metal concentration increased at pH of 6, the removal efficiency increased. The removal efficiencies in all heavy metals were over 80%. From the analysis of the sludge after reaction with heavy metals, the HAp was detected and the OCP peak was not observed. Moreover, lead ion was observed at the peaks of lead-Apatite and lead oxidant. In the case of cadmium, copper and iron ions, hydroxide forms of each ion were also detected.