• Title/Summary/Keyword: Cu/PET

Search Result 53, Processing Time 0.023 seconds

Flexible and Transparent CuO/Cu/CuO Electrodes Grown on Flexible PET Substrate by Continuous Roll-to-roll Sputtering for Touch Screen Panels Cells

  • Kim, Dong-Ju;Kim, Han-Ki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.217.2-217.2
    • /
    • 2014
  • We prepared a flexible and transparent CuO/Cu/CuO multilayer electrodes on a polyethylene terephthalate (PET) substrate using a specially designed roll-to-roll sputtering system at room temperature for GFF-type touch screen panels (TSPs). By the continuous roll-to-roll sputtering of the CuO and Cu layer, we fabricated a flexible CuO(150nm)/Cu(150nm)/CuO(150nm) multilayer electrodes with a sheet resistance of $0.289{\Omega}/square$, resistivity of $5.991{\times}10^{-23}{\Omega}-cm$, at the optimized condition without breaking the vacuum. To investigate the feasibility of the CuO/Cu/CuO multilayer as a transparent electrode for GFF-type TSPs, we fabricated simple GFF-type TSPs using the diamond patterned CuO/Cu/CuO electrode on PET substrate as function of mesh line width. Using diamond patterned CuO/Cu/CuO electrode of mesh line $5{\mu}m$ with sheet resistance of 38 Ohm/square, optical transmittance of 90% at 550 nm and an average transmittance of 89% at wavelength range from 380 to 780 nm, we successfully demonstrated GFF-type touch panel screens (TPSs). The successful operation of GFF-type TPSs with CuO/Cu/CuO multilayer electrodes indicates that the CuO/Cu/CuO multilayer is a promising transparent electrode for large-area capacitive-type TPSs due to its low sheet resistance and high transparency.

  • PDF

Development & Assessment of Alkyl Chain Modified Aptamers as Potential PET Radiotracers for Lymphoma Diagnosis

  • Ji Woong Lee;Un Chol Shin;Seok u Bae;Ji Yoon Kim;Hae joon Cho;Ji Ae Park;Kyo Chul Lee;Jung Young Kim;Suhng Wook Kim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.2
    • /
    • pp.77-85
    • /
    • 2022
  • The Td05 and Sgc8c, DNA-based aptamers, are well-known to target internalized surface markers (IGHM and PTK7) of Burkitt's lymphoma and acute lymphoblastic leukemia (ALL). Thus, Td05 and Sgc8c labeled with metallic radioisotope 64Cu can be evaluated as potential diagnostic PET imaging agents. In this study, we modified the carbon chain length of the last adenosine of aptamer (n = 3, 6, 12) to increase tumor cell uptake and select the best candidate among six types of aptamer analogues and one adenosine of aptamer. After labeling of 64Cu, [64Cu]Cu-DOTA-aptamer analogues were evaluated in vitro studies (serum stability, Log P values, cell uptake, biodistribution). Then, we evaluate in vivo PET imaging study for two candidates (64Cu-DOTA-C12-Sgc8c, 64Cu-DOTA-C6-Td05). PET images clearly visualize tumors at 24 h post-injection rather than at an early time point and the tumor-to-background ratio also increases at the delay time point. 64Cu-DOTA-C12-Sgc8c and 64Cu-DOTA-C6-Td05 could be used as potential radiotracers for lymphoma.

Investigation of Eco-friendly Electroless Copper Coating by Sodium-phosphinate

  • Rha, Sa-Kyun;Lee, Youn-Seoung
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.4
    • /
    • pp.264-268
    • /
    • 2015
  • Cu films were plated in an eco-friendly electroless bath (No-Formaldehyde) on Ni/screen printed Ag pattern/PET substrate. For electroless Cu plating, we used sodium-phosphinate ($NaH_2PO_2{\cdot}H_2O$) as reducing agent instead of Formaldehyde. All processes were carried out in electroless solution of pH 7 to minimize damage to the PET substrate. According to the increase of sodium-phosphinate, the deposition rate, the granule size, and rms roughness of the electroless Cu film increased and the Ni content also increased. The electroless Cu films plated using 0.280 M and 0.575 M solutions of sodium-phosphinate were made with Cu of 94 at.% and 82 at.%, respectively, with Ni and a small amount P. All electroless Cu plated films had typical FCC crystal structures, although the amount of co-deposited Ni changed according to the variation of the sodium-phosphinate contents. From these results, we concluded that a formation of higher purity Cu film without surface damage to the PET is possible by use of sodium-phosphinate at pH 7.

Luminescence Intensity Change Using N-Carbamoylglycine, N-Salicylideneaniline and Metal ions (N-Carbamoylglycine 및 N-Salicylideneaniline과 Metal ions들에 의한 발광 세기의 변화)

  • Kim, Ji Ung;Kim, Yeong Hae
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.6
    • /
    • pp.502-508
    • /
    • 2002
  • We have used PET chemosensors in the determination of N-carbamoylglycine. When N-carbam-oylglycine reacts with complex already made by the fluorophore and metal ion, the luminescence intensity can be changed and this phenomenon can be utilized in quantification. We used three metal ions, $Zn^{2+}$, $Ni^{2+}$, $Cu^{2+}$ and in order to investigate selectivity an acetic acid was used. $Ni^{2+}$ ion showed change in the eT mechanism by the anions. $Cu^{2+}$ ion showed the ability to distinguish N-carbamoylglycine from an acetic acid and it is noteworthy that $Zn^{2+}$ ion can change luminescence sensitively according to concentration.

무전해 도금방식을 이용한 PET 필름 위 선택적 Ni-Cu 박막의 특성분석

  • Kim, Na-Yeong;Baek, Seung-Deok;Lee, Yeon-Seung;Kim, Hyeong-Cheol;Na, Sa-Gyun;Choe, Seong-Chang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.387.2-387.2
    • /
    • 2014
  • 최근 이동통신 LED 에너지 자동차 산업분야에서 제품의 고기능화 고성능화를 위한 신소재 개발 및 친환경적인 신공정 개발에 있어, PI 또는 PET와 같은 유연성 소재 위에 선택적 패턴 도금 기술, 고기능성 나노/복합 도금 등이 주목 받고 있다. 또한 전 세계적으로 유해물질의 수 출입 규제 움직임이 강력하게 제기되고 있다. 본 연구에서는 유연성 소재인 PET 위에 친환경적 방법으로 구리를 선택적으로 도금하기 위한 실험을 진행하였다. 준비된 PET 필름 위에 Ag paste를 Screen Printing법을 이용하여 Ag 전극을 패턴하고, 그 위에 무전해 도금방식을 이용하여 Ni과 Cu가 도금 되도록 하였다. Ni 무전해 도금은 pH6.5, 65도에서 시행되었으며, Cu 무전해 도금은 환경규제물질인 포름알데히드 대신에 차아인산나트륨을 사용하여 70도에서, 중성근처의 pH 농도(pH7과 pH8)에서 시행되었다. 이들 다층 박막에 대해 X-ray diffraction (XRD), SEM (Scanning Electron Microscope), XPS (X-ray Photoelectron Spectroscopy) 등을 이용하여 물리-화학적/전기적 특성들을 이용하여 조사 분석하였다.

  • PDF

Etchless Fabrication of Cu Circuits Using Wettability Modification and Electroless Plating (젖음성 차이와 무전해도금을 이용한 연성 구리 회로패턴 형성)

  • Park, Sang-Jin;Ko, Tae-Jun;Yoon, Juil;Moon, Myoung-Woon;Han, Jun Hyun
    • Korean Journal of Materials Research
    • /
    • v.25 no.11
    • /
    • pp.622-629
    • /
    • 2015
  • Cu circuits were successfully fabricated on flexible PET(polyethylene terephthalate) substrates using wettability difference and electroless plating without an etching process. The wettability of Cu plating solution on PET was controlled by oxygen plasma treatment and $SiO_x$-DLC(silicon oxide containing diamond like carbon) coating by HMDSO(hexamethyldisiloxane) plasma. With an increase of the height of the nanostructures on the PET surface with the oxygen plasma treatment time, the wettability difference between the hydrophilicity and hydrophobicity increased, which allowed the etchless formation of a Cu pattern with high peel strength by selective Cu plating. When the height of the nanostructure was more than 1400 nm (60 min oxygen plasma treatment), the reduction of the critical impalement pressure with the decreasing density of the nanostructure caused the precipitation of copper in the hydrophobic region.

Synthesis and biological evaluation of diagnostic reagent for prostate cancer using copper-64 radioisotope

  • Ahn, Heesu;Kim, Mi Hyun;Han, Sang Jin;Woo, Sang Keun;Kim, Jung Young;Lee, Kyu Chul;Lim, Il Han;Lee, Yong Jin
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.4 no.2
    • /
    • pp.65-72
    • /
    • 2018
  • Prostate specific membrane antigen (PSMA) is a cell surface membrane protein, which is overexpressed in most prostate cancer. Recently, PET imaging with $[^{68}Ga]$PSMA-HBED-CC has been widely used for the diagnosis of recurrent prostate cancer and the studies on the diagnostic potential of $^{64}Cu$-labeled PSMA ligands reported actively. In this study, we monitored with biological evaluation in vivo and PET imaging of $^{64}Cu$-labeled PSMA ligand ($[^{64}Cu]$PSMA-617). The radiolabelling efficiency and stability of $[^{64}Cu]$PSMA-617 were confirmed by radio-thin layer chromatography. The radiolabeling efficiency of $[^{64}Cu]$PSMA-617 showed over 95%, and stabilities of intact remained over 98% in both human and mouse serum for 48 h. In normal male mice, in vivo uptake of $[^{64}Cu]$PSMA-617 in several organs was measured at 2, 4, 6, 24, 48 h after injection. Rapid blood clearance was observed for $[^{64}Cu]$PSMA-617. The high uptake was observed in the lung, liver, intestines and kidneys at 2 h postinjection, but was low in the other organs (1-2 %ID/g) at 4 h. The dynamic PET/CT images of 22RV1 tumor-bearing nude mice were acquired during 60 min and additionally acquired 24 h and 48 h after injection. In dynamic PET images, $[^{64}Cu]$PSMA-617 uptake ratio in tumors versus muscle was increased as time elaplsed until 60 minutes and remained in tumors at 48 h. In these results, the PET/CT imaging using $[^{64}Cu]$PSMA-617 in prostate cancer is expected to be useful for the diagnosis and treatment of prostate cancer patients.

Linear Ion Beam Applications for Roll-to-Roll Metal Thin Film Coatings on PET Substrates

  • Lee, Seunghun;Kim, Do-Geun
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.162-166
    • /
    • 2015
  • Linear ion beams have been introduced for the ion beam treatments of flexible substrates in roll-to-roll web coating systems. Anode layer linear ion sources (300 mm width) were used to make the linear ion beams. Oxygen ion beams having an ion energy from 200 eV to 800 eV used for the adhesion improvement of Cu thin films on PET substrates. The Cu thin films deposited by a conventional magnetron sputtering on the oxygen ion beam treated PET substrates showed Class 5 adhesion defined by ASTM D3359-97 (tape test). Argon ion beams with 1~3 keV used for the ion beam sputtering deposition process, which aims to control the initial layer before the magnetron sputtering deposition. When the discharge power of the linear ion source is 1.2 kW, static deposition rate of Cu and Ni were 7.4 and $3.5{\AA}/sec$, respectively.

Research status for long term half-life PET radioisotopes in KIRAMS

  • Kim, Jung Young;Park, Hyun;Chun, Kwon Soo;An, Gwang Il
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • It is essential use of long term half life radioisotopes for positron emission tomography (PET) imaging study of biopharmaceuticals because most of biopharmaceuticals have long biological half-life. Some representative isotopes are $^{124}I$, $^{64}Cu$, $^{89}Zr$ and so on. These PET radioisotopes and their radiopharmaceuticals have recently received growing interest because of long half life and good imaging properties. Furthermore, $^{64}Cu$ and $^{89}Zr$ can be used in a number of radiopharmaceuticals due to its ease of conjugation to peptides and antibodies using the proper chelator. In recent years, since $^{124}I$ was first developed in 2005, we have been studied to develop an efficient method and procedure for producing these radioisotopes, and we have made considerable progress in production of long term half life radioisotopes. This review introduces the general production system, purification procedure, and several advances on targeting method for $^{124}I$ and $^{64}Cu$ in KIRAMS.

Adhesion Change of AZO/PET Film by ZrCu Insertion Layer

  • Ko, Sang-Won;Jung, Jong-Gook;Park, Kyeong-Soon;Lim, Sil-Mook
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.3
    • /
    • pp.252-259
    • /
    • 2016
  • In order to form an aluminum-doped zinc oxide (AZO) transparent electrode film on a polyethylene terephthalate (PET) substrate used for a flexible display substrate, the AZO transparent electrode was produced at low temperature without substrate heating. Even though the produced electrode showed characteristic optical transmittance of 90 % (at 550 nm) and sheet resistance within $100{\Omega}/sq$, cracks occurred 10 minutes after loading applied 2 mm radius of curvature, and the sheet resistance increased linearly. An insertion layer of ZrCu was formed between the AZO film and the PET substrate to suppress the generation of cracks on the AZO film. It was verified that the crack was not generated 30 minutes after the loading of 2 mm radius of curvature, and no increase in sheet resistance was recorded. There was also not cracks in the dynamic bending test of 4 mm radius, but surface resistance was slightly increased. As a result, the ZrCu insertion film improved the interfacial adhesion between the substrate and AZO film layer without increasing sheet resistance and decreasing transmittance.