• 제목/요약/키워드: Cu/PET

검색결과 53건 처리시간 0.023초

Failure Mechanism of Cu/PET Flexible Composite Film with Anisotropic Interface Nanostructure

  • Park, Sang Jin;Han, Jun Hyun
    • 한국재료학회지
    • /
    • 제30권3호
    • /
    • pp.105-110
    • /
    • 2020
  • Cu/PET composite films are widely used in a variety of wearable electronics. Lifetime of the electronics is determined by adhesion between the Cu film and the PET substrate. The formation of an anisotropic nanostructure on the PET surface by surface modification can enhance Cu/PET interfacial adhesion. The shape and size of the anisotropic nanostructures of the PET surface can be controlled by varying the surface modification conditions. In this work, the effect of Cu/PET interface nanostructures on the failure mechanism of a Cu/PET flexible composite film is studied. From observation of the morphologies of the anisotropic nanostructures on plasma-treated PET surfaces, and cross-sections and surfaces of the fractured specimens, the Cu/PET interface area and nanostructure width are analyzed and the failure mechanism of the Cu/PET film is investigated. It is found that the failure mechanism of the Cu/PET flexible composite film depends on the shape and size of the plasmatreated PET surface nanostructures. Cu/PET interface nanostructures with maximal peel strength exhibit multiple craze-crack propagation behavior, while smaller or larger interface nanostructures exhibit single-path craze-crack propagation behavior.

플라즈마 에칭 및 $PdCl_2/SnCl_2$ 촉매조건이 무전해 동도금 피막의 성능에 미치는 영향 (Effect of Plasma Etching and $PdCl_2/SnCl_2$ Catalyzation on the Performance of Electroless Plated Copper Layer)

  • 오경화;김동준;김성훈
    • 한국의류학회지
    • /
    • 제27권7호
    • /
    • pp.843-850
    • /
    • 2003
  • Cu/PET film composites were prepared by electroless copper plating method. In order to improve adhesion between electroless plated Cu layer and polyester (PET) film, the effect of pretreatment conditions such as etching method, mixed catalyst composition were investigated. Chemical etching and plasma treatment increased surface roughness in decreasing order of Ar>HCl>O$_2$>NH$_3$. However, adhesion of Cu layer on PET film increased in the following order: $O_2$<Ar<HCl<NH$_3$. It indicated that appropriate surface roughness and introduction of affinitive functional group with Pd were key factors of improving adhesion of Cu layer. PET film was more finely etched by HCI tolution, resulting in an improvement in adhesion between Cu layer and PET film. Plasma treatment with NH$_3$produced nitrogen atoms on PET film, which enhances chemisorption of Pd$^{2+}$ on PET film, resulting in improved adhesion and shielding effectiveness of Cu layer deposited on the Pd catalyzed surface. Surface morphology of Cu plated PET film revealed that Pd/Sn colloidal particles became more evenly distributed in the smaller size by increasing the molar ratio of PdCl$_2$; SnCl$_2$from 1 : 4 to 1 : 16. With increasing the molar ratio of mixed catalyst, adhesion and shielding effectiveness of Cu plated PET film were increased.d.

무전해 동도금 피막의 접착력 향상에 관한 연구 - PET 필름의 전처리 조건의 영향 - (Adhesion Improvement of Electroless Copper Plated Layer on PET Film - Effect of Pretreatment Conditions -)

  • 오경화;김동준;김성훈
    • 폴리머
    • /
    • 제25권2호
    • /
    • pp.302-310
    • /
    • 2001
  • 무전해도금법을 이용하여 구리/PET 필름 복합재료를 제조하였으며 에칭방법과 촉매액의 조성 및 acceleration 방법을 달리하여 PET 필름과 무전해도금된 구리 피막간의 접착력을 향상시키고자 하였다. HCl 용액으로 에칭된 PET 필름은 NaOH에 의한 것보다 더욱 세밀하게 에칭되어져 구리와 PET 필름간의 접착력은 향상되었으나 전자파 차폐효과는 유사한 경향을 보였다. 촉매액의 조성변화에 따른 영향을 살펴본 결과 PdCl$_2$:SnCl$_2$의 몰비가 1:4에서 1:16으로 증가할수록 PET 필름 위에 적층된 Pd/Sn 콜로이드 입자들의 크기가 감소하며 고르게 분포되는 경향을 보였다. 따라서 이들의 몰비가 증가할수록 구리도금이 균일하고 조밀하게 이루어져 접착력 및 차폐효과가 증가하였다. 또한 NaOH보다 HCl로 acceleration한 경우 촉매 입자의 크기가 작고 더 균일하게 분포되어 우수한 접착력과 도금물성을 나타내었다.

  • PDF

Cu, Mn/γ-Al2O3 촉매상에서 polyethylene telephthalate 단량체의 회수 연구 (Recovery of Polyethylene Telephthalate Monomer over Cu or Mn/γ-Al2O3 Catalysts)

  • 심재욱;김승수
    • 공업화학
    • /
    • 제28권4호
    • /
    • pp.485-489
    • /
    • 2017
  • Polyethylene terephthalate (PET)는 화학적 안정성과 높은 기계적 강도를 가지고 있어 식품, 의류 등 다양한 분야에서 사용되고 있으며, 이로 인해 PET는 주요 폐플라스틱 폐기물 중 하나이다. 본 연구에서 PET를 재활용하기 위해 ethylene glycol (EG)와 glycolysis의 반응을 이용하여 단량체 회수에 관한 연구를 수행하였다. 마이크로 튜빙 반응기를 사용하여 EG/PET비율 1~4, 반응시간 15~90 min, 반응온도 $250{\sim}325^{\circ}C$에서 망간, 구리 촉매 조건하에서 연구를 진행하였다. 10 wt% $Cu/{\gamma}-Al_2O_3$ 촉매에서 반응온도, 시간과 EG/PET의 비가 각각 $300^{\circ}C$, 30 min와 1 : 2였을 때 가장 높은 89.46%의 bis (2-hydroxyethyl) terephthalate monomer (BHET) 수율을 나타내었다.

High adhesive and long-life Cu/PET flexible substrate

  • 한준현;박상진;문명운;윤주일
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2015년도 추계학술대회 논문집
    • /
    • pp.168-168
    • /
    • 2015
  • 플라즈마를 이용하여 PET표면에 나노구조를 형성시킨 후 무전해 도금에 의해 구리를 코팅함으로써 플랙서블한 Cu/PET 기판을 제조하였다. 플라즈마 에칭시간을 달리하여 나노구조의 크기와 모양을 변화시켰으며 나노구조의 크기와 모양의 변화에 따른 Cu와 PET의 접합강도와 피로특성을 평가하였다.

  • PDF

Intratumoral distribution of 64Cu-ATSM and 18F-FDG in VX2tumor xenografted rabbit

  • Yoo, Ran Ji;Lee, Ji Woong;Lee, Kyo Chul;An, Gwang Il;Ko, In Ok;Chung, Wee Sup;Park, Ji Ae;Kim, Kyeong Min;Choi, Yang-Kyu;Kang, Joo Hyun;Lim, Sang Moo;Lee, Yong Jin
    • 대한방사성의약품학회지
    • /
    • 제1권2호
    • /
    • pp.123-129
    • /
    • 2015
  • $^{64}Cu$-labeled diacetyl-bis($N^4$-methylthiosemicarbazone) is a promising agent for internal radiation therapy and imaging of hypoxic tissues. In the study, we confirmed hypoxia regions in VX2 tumor implanted rabbits with injection $^{64}Cu$-ATSM and $^{18}F$-FDG using positron emission tomography (PET)/computed tomography (CT). PET images with $^{18}F$-FDG and $^{64}Cu$-ATSM were obtained for 40 min by dynamic scan and additional delayed PET images of $^{64}Cu$-ATSM the acquired up to 48 hours. Correlation between intratumoral $O_2$ level and $^{64}Cu$-ATSM PET image was analyzed. $^{64}Cu$-ATSM and $^{18}F$-FDG were intravenously co-injected and the tumor was dissected and cut into slices for a dual-tracer autoradiographic analysis. In the PET imaging, $^{64}Cu$-ATSM in VX2 tumors displayed a specific uptake in hypoxic region for48 h. The uptake pattern of $^{64}Cu$-ATSM in VX2 tumor at 24 and 48 h did not match to the $^{18}F$-FDG. Through ROI analysis, in the early phase (dynamic scan), $^{18}F$-FDG has positive correlation with $^{64}Cu$-ATSM but late phase (24 and 48 h) of the $^{64}Cu$-ATSM showed negative correlation with $^{18}F$-FDG. High uptake of $^{64}Cu$-ATSM in hypoxic region was responded with significant decrease of oxygen pressure, which confirmed by $^{64}Cu$-ATSM PET imaging and autoradiographic analysis. In conclusion, $^{64}Cu$-ATSM can utilize for specific targeting of hypoxic region in tumor, and discrimination between necrotic- and viable hypoxic tissue.

Effect of filters and reconstruction method on Cu-64 PET image

  • Lee, Seonhwa;Kim, Jung min;Kim, Jung Young;Kim, Jin Su
    • 대한방사성의약품학회지
    • /
    • 제3권2호
    • /
    • pp.65-71
    • /
    • 2017
  • To assess the effects of filter and reconstruction of Cu-64 PET data on Siemens scanner, the various reconstruction algorithm with various filters were assessed in terms of spatial resolution, non-uniformity (NU), recovery coefficient (RC), and spillover ratio (SOR). Image reconstruction was performed using filtered backprojection (FBP), 2D ordered subset expectation maximization (OSEM), 3D reprojection algorithm (3DRP), and maximum a posteriori algorithms (MAP). For the FBP reconstruction, ramp, butterworth, hamming, hanning, or parzen filters were used. Attenuation or scatter correction were performed to assess the effect of attenuation and scatter correction. Regarding spatial resolution, highest achievable volumetric resolution was $3.08mm^3$ at the center of FOV when MAP (${\beta}=0.1$) reconstruction method was used. SOR was below 4% for FBP when ramp, Hamming, Hanning, or Shepp-logan filter were used. The lowest NU (highest uniform) after attenuation & scatter correction was 5.39% when FBP (parzen filter) was used. Regarding RC, 0.9 < RC < 1.1 was obtained when OSEM (iteration: 10) was used when attenuation and scatter correction were applied. In this study, image quality of Cu-64 on Siemens Inveon PET was investigated. This data will helpful for the quantification of Cu-64 PET data.

Cl$_2$ 플라즈마를 인가한 CuCl$_{x}$성장 및 PEt$_3$를 이용한 CuCl$_{x}$의 식각에 대한 연구 (A study of CuCl$_{x}$ growth mechanism and etching with Cl$_2$ plasma and PEt$_3$(Tri-ethyl phospine))

  • 박성언;김기범
    • 한국표면공학회지
    • /
    • 제30권2호
    • /
    • pp.111-120
    • /
    • 1997
  • The growth kinetion of $CuCl_x$ layer on Cu was investigated using $Cl_2$ gas with/without plasma. The etching kinetics ofit was also studied, in which PEt3 gas as well as $Cl_2$ gas were used. when plasma and DC bias were applied, not only the growth rate of $CuCl_x$ layer but also the surface concentration of Cl in $CuCl_x$ layer drastically increased. The growth mode is divided into three regimes, where the thinkness $CuCl_x$ layer ise proportional to t, lo9g $T^{1/2}$ , respectively, whether plasma, is applied or not. These three regime. It is also identified that the eath rate of Cu is drastically increased as the $Cl_2$ pressure is increased. However, when plasma and DC bias were applied, the etching rate is decreased, and ClCu-P-U layer is formed. in addition, as the etching time is increased, the surface concentration of Cl is increased and $CuCl_2$ formed partially.

  • PDF

PET 필름상 형성한 전자파차폐용 박막과 그 특성 (Formation of Electromagnetic Wave Shielding Thin Film on PET Film Substrate and Their Properties)

  • 임경민;이훈성;배일용;문경만;최철수;이명훈
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2011년도 춘계학술대회 및 Fine pattern PCB 표면 처리 기술 워크샵
    • /
    • pp.205-206
    • /
    • 2011
  • Cu thin films for electromagnetic wave shielding were prepared on PET film and Ni-coated PET film by using Dry and Wet coating method, such as evaporation method, DC sputtering method and copper sulfate($CuSO_4$). After that, Zn thin film and Ni thin film were prepared onto the Cu thin films by using evaporation dry process and Ni electro plating wet process as a finishing treatment, respectively. The result of conductivity test and corrosion resistance test revealed Cu thin films which were formed with bigger grain size and high Cu composition rate have superior properties. Zn thin film by dry evaporation process and Ni thin film by wet electro plating process on Cu thin films were largely contributed to corrosion resistance. However, Ni thin film by wet process made conductivity of all specimen worse, the other hand, Zn thin film by dry process made it better to improve condictivity of specimens just prepared by dry process.

  • PDF

Cu-64 as a Cancer Theranostics Agent

  • Kwang Il Kim
    • 대한방사성의약품학회지
    • /
    • 제8권2호
    • /
    • pp.139-150
    • /
    • 2022
  • Theranostics, a composite word of therapy and diagnosis, is known as personalized medicine and the concept of diagnosis and treatment at the same time. In nuclear medicine, it means performing both therapeutic and diagnostic radioisotope therapy using the same target molecule. The increased production and utilization of 64Cu opens a new era of theranostics. The studies introduced here have shown that 64CuCl2 and various compounds or biomolecules labeled with 64Cu are unique radiopharmaceuticals with physiological properties suitable for use as diagnostic and therapeutic agents. So far, these two abilities have been described only for radioactive iodine. Although 64Cu has complex chemical properties compared to other PET radioisotopes such as 68Ga, it has an appropriate half-life and enables high-quality PET images similar to 18F, which is an advantage in terms of diagnosis. In addition, since it also has therapeutic properties through the release of β- particles and Auger electrons by electron capture, radiopharmaceuticals using 64Cu stand for innovative radiopharmaceuticals for theranostic purposes. Therefore, based on the initial results obtained using 64Cu as a therapeutic agent, it is expected that additional research on the application of 64Cu will lead to a new era in the theranostics field.