• Title/Summary/Keyword: CsI

Search Result 631, Processing Time 0.032 seconds

Design and Fabrication of HgI2 Sensor for Phosphor Screen based flat panel X-ray Detector (형광체 스크린 기반 평판형 X선 검출기 적용을 위한 요오드화수은 필름 광도전체 센서 설계 및 제작)

  • Park, Ji Koon;Jung, Bong Jae;Choi, Il Hong;Noh, Si Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.189-194
    • /
    • 2014
  • In this study, from a new x-ray detector that combines a columnar CsI:Na scintillation layer with a photosensitive mercuric iodide layer was investigated. In this structure, X-rays are converted into visible light on a thick CsI:Na layer, which is then converted to electric charges in a thin $HgI_2$ bottom layer. The thin coplanar mercuric iodide films as a photosensitive converter requiring only a few tens of volts of bias, associated with a thick columnar coating of phosphor layer, were simulated and designed. The results of this research suggest that the new coplanar x-ray detector with a hybrid-type structure can resolve the following problems: high voltage from the a-Se, and low conversion efficiency from the indirect conversion method. The results of this research suggest that the new CsI:Na/$HgI_2$ x-ray detector with a double-layer type structure can resolve the following problems: high voltage from the direct conversion method, and low conversion efficiency from the indirect conversion method.

Cesium NMR in a Paramagnetic $CsMnCl_{3}$ Single Crystal (상자성체 $CsMnCl_{3}$ 단결정에서 $^{133}Cs$ 핵자기공명 연구)

  • Tae-Jong Han
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.2
    • /
    • pp.184-187
    • /
    • 1994
  • Nuclear magnetic resonance of $^{133}Cs$ in a $CsMnCl_{3}$ single crystal grown by the Czochralski method has been investigated by employing a Bruker FT NMR spectrometer. The $^{133}Cs$ resonance of two different groups were recorded. Various transitions belonging to two cesium spectra of a different intensity ratio are analyzed. The quadrupole coupling constant of Cs(I) is $0.15{\pm}0.01$ MHz, and that of Cs(II) is $0.21{\pm}0.01$ MHz. The anisotropy parameter is zero for both. The principal axes of the EFG tensors for these two sites are found to be the same. The Z axis, conventionally the largest component of the EFG tensor, is parallel to the crystallographic c-axis.

  • PDF

Study on Electrical Properties of X-ray Sensor Based on CsI:Na-Selenium Film

  • Park Ji-Koon;Kang Sang-Sik;Lee Dong-Gil;Choi Jang-Yong;Kim Jae-Hyung;Nam Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.3
    • /
    • pp.10-14
    • /
    • 2003
  • In this paper, we have introduced the x-ray detector built with a CsI:Na scintillation layer deposited on amorphous selenium. To determine the thickness of the CsI:Na layer, we have estimated the transmission spectra and the absorption of continuous x-rays in diagnostic range by using computer simulation (MCNP 4C). A x-ray detector with 65 ${\mu}m$-CsI:Na/30 ${\mu}m$-Se layer has been fabricated by a thermal evaporation technique. SEM and PL measurements have been performed. The dark current and x-ray sensitivity of the fabricated detector has been compared with that of the conventional a-Se detector with 100 ${\mu}m$ thickness. Experimental results show that both detectors exhibit a similar dark current, which was of a low value below $400 pA/cm^2$ at 10 V/${\mu}m$. However, the CsI:Na-Se detector indicates high x-ray sensitivity, roughly 1.3 times that of a conventional a-Se detector. Furthermore, a CsI:Na-Se detector with an aluminium reflective layer shows a 1.8 times higher x-ray sensitivity than an a-Se detector. The hybrid type detector proposed in this work exhibits a low dark current and high x-ray sensitivity, and, in particular, excellent linearity to the x-ray exposure dose.

Electron Probe Micro Analysis of Cs in $UO_2$ (우라늄산화물중 Cs의 전자탐침 미세분석)

  • Park, Soon Dal;Joe, Kih Soo;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.203-211
    • /
    • 2001
  • In this paper it was described on the intereference effect of uranium to analyze Cs in $UO_2$ by Electron Probe Micro Analysis(EPMA) and the beam stability of Cs $L_{\alpha}$ X-ray intensity for some Cs compounds. According to the experimental results, the CsI showed the highest $L_{\alpha}$ X-ray intensity among the tested Cs compounds at the experimental condition; 15~30 kV of accelerating voltage and PET, LiF crystal. When 100 nA of beam current was applied to Cs compounds, Cs $L_{\alpha}$ X-ray intensity was continuously decreased with increasing time. The decreasing rate of Cs $L_{\alpha}$ X-ray intensity was directly proportional to the applied beam current and accelerating voltage but inversely proportional to the applied beam size. It was found that uranium interference can be prevented by using Cs $L_{\alpha}$ X-ray wavelength of Lif crytal for Cs analysis in $UO_2$ by EPMA.

  • PDF

Crystal Structure of Dehydrated Partially Ag$^+$-Exchanged Zeolite A treated with Cesium Vapor at 250${^{\circ}C}$

  • Kim, Duk-Soo;Song, Seong-Hwan;Kim, Yang
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.3
    • /
    • pp.234-238
    • /
    • 1989
  • The crystal structure of partially $Ag^+$-exchanged zeolite A, $Ag_{3.2}Na_{8.8}$-A, vacuum dehydrated at $360^{\circ}C$ and then exposed to 0.1 torr of cesium vapor for 12 hours at $250^{\circ}C$ has been determined by single-crystal X-ray diffraction techniques in the cubic space group Pm3m (a = 12.262(2)${\AA})\;at\;21(1)^{\circ}C$. The structure was refined to the final error indexes $R_1=0.068\;and\;R_2=0.072$ by using 338 reflections for which $I_o\;>\;3{\sigma}(I_o)$ and the composition of unit cell is $Ag_{3.2}Cs_{8.8}-A.\;3\;Cs^+$ ions lie on the centers of the 8-rings at sites of D4h symmetry. Two crystallographycally different 6-ring $Cs^+$ ions were found: 1.5 $Cs^+$ ions at Cs(2) are located inside of sodalite cavity and 4.3 $Cs^+$ ions at Cs(3) are located in the large cavity. The fractional occupancies observed at Cs(2) and Cs(3) indicate that the existence of at least three types of unit cells with regard to the 6-ring $Cs^+$ ions. For example, 50% of unit cells may have two $Cs^+$ ions at Cs(2) and 4 $Cs^+$ ions at Cs(3). 30% of unit cells may have one Cs+ ion at Cs(2) and 5 $Cs^+$ ions at Cs(3). The remaining 20% would have one $Cs^+$ ion at Cs(2) and 4 $Cs^+$ ions at Cs(3). On threefold axes of the unit cell two non-equivalent Ag atom positions are found in the large cavity, each containing 0.64 and 1.92 Ag atoms, respectively. A crystallographic analysis may be interpreted to indicate that 0.64 $(Ag_5)^+$ clusters are present in each large cavity. This cluster may be viewed as a tetrasilver molecule $(Ag_4)^0$(bond length, 2.84${\AA}$) stabilized by the coordination of one $Ag^+$ ion.

A Study of the Inorganic Scintillator Properties for a Phoswich Detector (Phoswich 검출기 제작을 위한 무기 섬광체 특성 연구)

  • Lee, Woo-Gyo;Kim, Yong-Kyun;Kim, Jong-Kyung;Tarasov, V.;Zelenskaya, O.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.251-256
    • /
    • 2004
  • CsI(Tl), $CdWO_4(CWO),\;Bi_4Ge_3O_{12}(BGO)\;and\;Gd_2SiO_5:Ce(GSO)$ scintillators were studied to manufacture a phoswich detector. The maximum wavelengths of the CsI(Tl), CWO, BGO and GSO scintillators are 550 nm, 475 nm, 490 nm and 440 nm for the radioluminescence, and the absolute light outputs of the CsI(Tl), CWO, BGO and GSO scintillators are 54890 phonon/MeV, 17762 phonon/MeV, 8322 phonon/MeV and 8932 phonon/MeV with a neutral filter, and the decay time of the CsI(Tl), CWO, BGO and GSO scintillators is $1.3{\mu}s,\;8.17{\mu}s$, 213 ns and 37 ns by a single photon method. The phoswich detector which was manufactured with plastic and CsI(Tl) scintillators could separate the ${\beta}$ particle and ${\gamma}$ ray. The phoswich detector could also measure the pulse height spectra of the ${\beta}$ particle and ${\gamma}$ ray by a PSD method.

Status of a national monitoring program for environmental radioactivity and investigation of artificial radionuclide concentrations (134Cs, 137Cs, 131I) in rivers and lakes (방사성물질 측정망 현황 및 하천·호소 내 인공방사성물질 (134Cs, 137Cs, 131I) 조사)

  • Kim, Jiyu;Jung, Hyun-ji;An, Mijeong;Hong, Jung-Ki;Kang, Taegu;Kang, Tae-Woo;Cho, Yoon-Hae;Han, Yeong-Un;Seol, Bitna;Kim, Wansuk;Kim, Kyunghyun
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.377-384
    • /
    • 2015
  • A survey of the artificial radionuclides in rivers and lakes was conducted to investigate their levels in surface water. Water samples were collected at 60 points and analyzed by gamma-ray spectrometry with a measurement time of 10,000 seconds for 134Cs, 137Cs, and 131I. The obained values were lower than MDA for all points, except one point for 131I that was 0.533±0.058 Bq/L. 131I is known as a radioactive material that occurs frequently in sewage treatment plants. Because it is often used for medical treatments and subject to spreading into the environment due to the excretion from the patients. For the point where 131I was detected, we conducted additional investigation on the upstream river point and the effluent points of nearby sewage treatment plant to find the source of 131I. 131I was not detected at the upstream points of one of the upstream sewage treatment plants but found at the downstream points with the level being 0.257±0.034 to 0.799±0.051 Bq/L, proving the sewage treatment plant was the 131Isource.

Removal of cesium(137Cs) and iodide(127I) by microfiltration·nanofiltration·reverese osmosis membranes (정밀여과·나노여과·역삼투 막에 의한 세슘과 요오드의 제거)

  • Chae, Seon-Ha;Kim, Chung-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.5
    • /
    • pp.549-554
    • /
    • 2014
  • This study was evaluated the applicability of the membrane filtration process (Micro Filtration (MF), nanofiltration membranes (NF), reverse osmosis (RO)) on the major radioactive substances, iodine ($I^-$) and cesium ($Cs^+$) using membranes produced in Korea and domestic raw water. Iodine ($I^-$) or cesium ($Cs^+$) in the microfiltration membrane (MF) process could not be expected removal efficiency by eliminating marginally at the combined state with colloidal and turbidity material. At the domestic raw water (lake water, turbidity 1.2 NTU, DOC 1.3 mg/L) conditions, nanofiltration membrane (NF) and reverse osmosis (RO) showed a high removal rate of about 88 ~ 99% for iodine ($I^-$) and cesium ($Cs^+$) and likely to be an alternative process for the removal of radioactive material.

Adsorption Characteristics of Sr(II) and Cs(I) ions by Zeolite Synthesized from Coal Fly Ash (Coal Fly Ash로 합성한 제올라이트에 의한 Sr(II)과 Cs(I) 이온의 제거 특성)

  • Lee, Chang-Han;Park, Jeong-Min;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.1987-1998
    • /
    • 2014
  • Zeolite was synthesized from power station waste, coal fly ash, as an alternative low-cost adsorbent and investigated for the removal of Sr(II) and Cs(I) ions from single- and binary metal aqueous solutions. In order to investigate the adsorption characteristics, the effects of various operating parameters such as initial concentration of metal ions, contact time, and pH of the solutions were studied in a batch adsorption technique. The Langmuir model better fitted the adsorption isotherm data than the Freundlich model. The pseudo second-order model was found more applicable to describe the kinetics of system. The adsorption capacities of Sr(II) and Cs(I) ions obtained from the Langmuir model were 1.7848 mmol/g and 0.7640 mmol/g, respectively. Although the adsorption capacities of individual Sr(II) and Cs(I) ions was less in the binary-system, the sum of the total adsorption capacity (2.3572 mmol/g) of both ions in the binary-system was higher than the adsorption capacity of individual ion in the single-system. Comparing the homogeneous film diffusion model with the homogeneous particle diffusion model, the adsorption was mainly controlled by the particle diffusion process.

Structure design of Csl-Se Detector using Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 Csl-Se 검출기의 구조 설계)

  • Park, Ji-Koon;Kang, Sang-Sik;Choi, Jang-Young;Lee, Hung-Won;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.420-423
    • /
    • 2002
  • In recent years, there has been keen interest in developing f1at panel detectors for all modalities of radiology, including gerneral radiology, fluoroscopy(angiography and cardiology), electronic portal imaging, and mammography. In this paper, we report the new hybrid x-ray detector consisted of CsI(Tl) photoemission layer and a-Se photoconductor layer to resolve conventional x-ray detector such as the direct detector using a-Se and the indirect detector using CsI(Tl)/a-Si. To design the structure of CsI(Tl)/a-Se detector, the penetrated energy spectrum and absorption fraction was estimated using MCNP 4C code. Experimental results showed that the absorption fraction of $500{\mu}m-Se$ film and $150{\mu}m-CsI\left(Tl \right)/a-Se\left( 30{\mu}m \right)$ film is 70% at 70 kVp. The absorption energy is 90% at $350{\mu}m-CsI(Tl)$.

  • PDF