• 제목/요약/키워드: Cryogenic refrigerator

검색결과 37건 처리시간 0.023초

Conceptual design of cryogenic turbo expander for 10 kW class reverse Brayton refrigerator

  • Lee, Chang Hyeong;Kim, Dong Min;Yang, Hyung Suk;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권3호
    • /
    • pp.41-46
    • /
    • 2015
  • Recently, the development of the HTS power cable is actively promoted. As the length of HTS power cable increases, there have been many efforts to develop large capacity cryocooler. Among the various cryocooler, the Brayton refrigerator is the most competitive for HTS power cable. The Brayton refrigerator is composed of recuperative heat exchangers, a compressor, and a cryogenic turbo expander. In these components, the cryogenic turbo expander is a part to decrease the temperature and it is the most significant component that is closely related with overall system efficiency. It rotates with high speed using a high-pressure helium or neon gas at cryogenic temperature. This paper describes the design of a 10 kW class Brayton refrigeration cycle and the cryogenic turbo expander. Flow and structural analysis are performed for the rotating impeller and nozzle to verify the efficiency and the design performance.

Review on innovative small refrigeration methods for sub-Kelvin cooling

  • Dohoon, Kwon;Junhyuk, Bae;Sangkwon, Jeong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권4호
    • /
    • pp.71-77
    • /
    • 2022
  • Sub-Kelvin cooling has been generally demanded for the fields of low temperature physics, such as physical property measurements, astronomical detection, and quantum computing. The refrigeration system with a small size can be appropriately introduced when the measurement system does not require a high cooling capacity at sub-Kelvin temperature. The dilution refrigerator which is a common method to reach sub-Kelvin, however, must possess a large 3He circulation equipment at room temperature. As alternatives, a sorption refrigerator and a magnetic refrigerator can be adopted for sub-Kelvin cooling. This paper describes those coolers which have been developed by various research groups. Furthermore, a cold-cycle dilution refrigerator of which the size of the 3He circulation system is minimized, is also introduced. Subsequently, a new concept of dilution refrigerator is proposed by our group. The suggested cooler can achieve sub-Kelvin temperature with a small size since it does not require any recuperator and turbo-molecular vacuum pump. Its architecture allows the compact configuration to reach sub-Kelvin temperature by integrating the sorption pump and the magnetic refrigerators. Therefore, it may be suitably utilized in the low temperature experiments requiring low cooling capacity.

A review on a 4 K cryogenic refrigeration system for quantum computing

  • Park, Jiho;Kim, Bokeum;Jeong, Sangkwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권2호
    • /
    • pp.1-6
    • /
    • 2022
  • This paper reviews the literature that has been published since 1980s related to cryogenic refrigeration systems for quantum computing. The reason why such a temperature level of 10-20 mK is necessary for quantum computing is that the superconducting qubit is sensitive to even very small thermal disturbances. The entanglement of the qubits may not be sustained due to thermal fluctuations and mechanical vibrations beyond their thresholds. This phenomenon is referred to as decoherence, and it causes an computation error in operation. For the stable operation of the quantum computer, a low-vibration cryogenic refrigeration system is imperative as an enabling technology. Conventional dilution refrigerators (DR), so called 'wet' DR, are precooled by liquid helium, but a more convenient and economical precooling method can be achieved by using a mechanical refrigerator instead of liquid cryogen. These 'dry' DRs typically equip pulse-tube refrigerators (PTR) for precooling the DRs around 4 K because of its particular advantage of low vibration characteristic. In this review paper, we have focused on the development status of 4 K PTRs and further potential development issues will be also discussed. A quiet 4 K refrigerator not only serves as an indispensable precooler of DR but also immediately enhances the characteristics of low noise amplifiers (LNA) or other cryo-electronics of various type quantum computers.

초전도 전력 케이블 냉각 시스템 적용을 위한 극저온 터보 팽창기 설계 및 해석 (Design and Analysis of Cryogenic Turbo Expander for HTS Power Cable Refrigeration System)

  • 이창형;김동민;양형석;김석호
    • 한국기계가공학회지
    • /
    • 제14권3호
    • /
    • pp.141-148
    • /
    • 2015
  • The cryogenic cooling system should maintain the HTS power cable below 77 K. As the length of HTS power cables has increased, there have been many efforts to develop large capacity cryocoolers. Brayton, Joule-Thomson, and Claude refrigerators were considered for the large capacity cryocooler. Among the various cryocoolers, the Brayton refrigerator is the most competitive in terms of the HTS power cable. At present, it is thought that a 10-kW class refrigerator will be able to be used as a unit cooling system for the commercialization of HTS power cables in the near future. The Brayton refrigerator is composed of recuperative heat exchangers, a compressor, and a cryogenic turbo expander. Among the various components, the cryogenic turbo expander is the part that decreases the temperature, and it is the most significant component that is closely related with overall system efficiency. It rotates at high speed using high-pressure helium or neon gas at cryogenic temperatures. This paper describes the design of a 300-W class Brayton refrigeration cycle and the cryogenic turbo expander as a downscale model for the practical 10-kW class cycle. Flow and structural analyses are performed on the rotating impeller and nozzle to verify the efficiency and the design performance.

소형 GM 냉동기를 이용한 수소 액화에 관한 시뮬레이션 연구 (A Simulation Study on the Hydrogen Liquefaction through Compact GM Refrigerator)

  • 정하늘;한단비;양원균;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제33권5호
    • /
    • pp.534-540
    • /
    • 2022
  • Liquid hydrogen has the best storage capacity per unit mass and is economical among storage methods for using hydrogen as fuel. As the demand for hydrogen increases, the need to develop a storage and supply system of liquid hydrogen is emphasizing. In order to liquefy hydrogen, it is necessary to pre-cool it to a maximum inversion temperature of -253℃. The Gifford-McMahon (GM) refrigerator is the most reliable and commercialized refrigerator among small-capacity cryogenic refrigerators, which can extract high-efficiency hydrogen through liquefied hydrogen production and boil of gas re-liquefaction. Therefore, in this study, the optimal conditions for liquefying gas hydrogen were sought using the GM cryocooler. The process was simulated by PRO/II under various cooling capacities of the GM refrigerator. In addition, the flow rate of hydrogen was calculated by comparing with specific refrigerator capacity depending on the pressure and flow rate of a refrigerant medium, helium. Simulations were performed to investigate the optimal values of the liquefaction flow rate and compression pressure, which aim for the peak refrigeration effect. Based on this, a liquefaction system can be selected in consideration of the cycle configuration and the performance of the refrigerator.

2 kW급 브레이튼 냉동기용 열역학 사이클 및 극저온 터보 팽창기 설계 (Design of Thermodynamic Cycle and Cryogenic Turbo Expander for 2 kW Class Brayton Refrigerator)

  • 이진우;이창형;양형석;김석호
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.299-305
    • /
    • 2016
  • 초전도 전력 케이블의 상용화 노력에 따라 점차 장선화 되면서, 단위 냉각 시스템당 냉각용량이 큰 대용량 냉동기의 필요성이 증가하고 있다. 국내에서는 극저온 냉동기에 대한 기술 부족으로 인해 현재 극저온 냉동기는 해외 선진사로부터 고가의 비용으로 수입되고 있다. 초전도 전력 케이블의 상용화를 위해서는 대용량 브레이튼 냉동기의 국내 개발이 시급하다. 대용량 브레이튼 냉동기의 구성은 복열식 열교환기, 압축기, 극저온 터보 팽창기로 구성되어 있으며, 냉동기 효율과 가장 직접적인 연관이 있는 것은 극저온 터보 팽창기이다. 극저온 터보 팽창기는 극저온에서 고속으로 회전하면서 고압의 헬륨 혹은 네온 가스를 팽창시켜 온도를 낮추는 역할을 한다. 본 논문에서는 역브레이튼 냉동 사이클을 설계하고, 이에 적합한 극저온 터보 팽창기를 설계하였다.

Cryogenic cooling system for HTS cable

  • Yoshida, Shigeru
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권2호
    • /
    • pp.1-8
    • /
    • 2017
  • Recently, Research and development activity of HTS (High Temperature Superconducting) power application is very progressive worldwide. Especially, HTS cable system and HTSFCL (HTS Fault current limiter) system are proceeding to practical stages. In such system and equipment, cryogenic cooling system, which makes HTS equipment cooled lower than critical temperature, is one of crucial components. In this article, cryogenic cooling system for HTS application, mainly cable, is reviewed. Cryogenic cooling system can be categorized into conduction cooling system and immersion cooling system. In practical HTS power application area, immersion cooling system with sub-cooled liquid nitrogen is preferred. The immersion cooling system is besides grouped into open cycle system and closed cycle system. Turbo-Brayton refrigerator is a key component for closed cycle system. Those two cooling systems are focused in this article. And, each design and component of the cooling system is explained.

300 W급 브레이튼 냉동기용 극저온 터보 팽창기 구동축 설계 (Design of a Cryogenic Turbo Expander Drive Shaft for 300 W Class Brayton Refrigerators)

  • 김만렬;이창형;김동민;양형석;김석호
    • 한국기계가공학회지
    • /
    • 제15권6호
    • /
    • pp.129-135
    • /
    • 2016
  • There have been many types of development and commercialization efforts for superconducting power applications with the continuous development of High Temperature Superconducting (HTS) conductors. In particular, HTS power cables are going to be commercialized in real power grids. A cryogenic refrigeration system should be used to keep it below 77 K, and its required cooling capacity continuously increases as the unit length of the HTS power cable increases. Among the many kinds of cryogenic refrigerator, a reverse Brayton refrigerator that uses turbo expanders is a promising refrigerator due to its efficiency and reliability. Among the various components in refrigerators, the cryogenic turbo-expander is the most important part for increasing efficiency and assuring reliability. The design of a 300 W class turbo-expander is described in this paper prior to the development of a 10 kW class turbo expander, which is the required capability for the commercialization of a HTS power cable. The impeller shape and rotation speed are determined based on the cycle analysis. The Eigen frequency and harmonic analysis are conducted with gas bearings at cryogenic temperatures to determine the operational stability.

고온 초전도 회전자 냉각을 위한 탑재형 맥동관 냉동기 연구 (Investigation on-board pulse tube refrigerator for high temperature superconducting rotor)

  • 남중원;정상권
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.316-319
    • /
    • 2003
  • Cryogenic refrigerator system is necessary for cooling the superconducting rotor. Among the various cryogenic refrigerator systems, on-board hybrid pulse tube cryocooler is designed for cooling the superconducting rotor. Hybrid pulse tube cryocooler is composed of pulse tube cryocooler and Stirling cryocooler. This Stirling cryocooler precools the middle point of regenerator to obtain lower temperature at cold part of pulse tube cryocooler. In this paper, only Stirling cryocooler is on-boarded then rotated by motor for various rotating speeds and heat loads at cold part of Stilting cryocooler. Through this experiment the feasibility of the on-board cryocooler is investigated.

  • PDF

Basic Design of Hydrogen Liquefier Precooled by Cryogenic Refrigerator

  • Kim, Seung-Hyun;Chang, Ho-Myung;Kang, Byung-Ha
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.124-135
    • /
    • 1998
  • A thermodynamic cycle analysis is performed for refrigerator-precooled Linde-Hampson hydrogen liquefiers, including catalysts for the ortho-to-para conversion. Three different configurations of the liquefying system, depending upon the method of the o-p conversion, are selected for the analysis. After some simplifying and justifiable assumptions are made, a general analysis program to predict the liquid yield and the figure of merit (FOM) is developed with incorporating the commercial computer code for the thermodynamic properties of hydrogen. The discussion is focused on the effect of the two primary design parameters - the precooling temperature and the high pressure of the cycle. When the precooling temperature is in a range between 45 and 60 K, the optimal high pressure for the maximal liquid yield is found to be about 100 to 140 bar, regardless of the ortho-to-para conversion. However, the FOM can be maximized at slightly lower high pressures, 75 to 130 bar. It is concluded that the good performance of the precooling refrigerator is significant in the liquefiers, because at low precooling temperatures high values of the liquid yield and the FOM can be achieved without compression of gas to a very high pressure.

  • PDF