• 제목/요약/키워드: Cryogenic liquid sensor

검색결과 7건 처리시간 0.022초

오븀 첨가 광섬유의 증폭 자발 방출을 이용한 저온 측정 (Cryogenic Temperature Measurement Using Amplified Spontaneous Emission of Erbium-Doped Fiber)

  • 이용욱
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1992-1994
    • /
    • 2007
  • In this paper we propose a cryogenic sensor system which can measure the temperature at higher resolution at low temperature using temperature-dependent amplified spontaneous emission of erbium-doped fiber pumped by a 1480 nm laser diode. The measurement resolution of the sensor system could be enhanced through the modulation of injection current of the pump laser diode. The measurement resolution considering the fluctuation of the light source in the sensor system was ${\sim}0.4$ K in the room temperature regime and ${\sim}0.07$ K in the liquid nitrogen temperature regime.

Design and manufacture of horn lens antennas of 80 GHz MM wave FMCW radar for cryogenic fluids level measurement

  • Jeon, S.M.;Mun, J.M.;Lee, S.C.;Sim, K.D.;Kim, S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권1호
    • /
    • pp.29-33
    • /
    • 2022
  • Recently, development of a cryogenic fluids storage tank for storing or transporting liquid hydrogen is actively in progress. In cryogenic fluids storage tanks, hydrogen evaporates due to the extreme temperature difference inside and outside the tank. As the mass of the cryogenic fluids changes with continuous vaporization, the fluids level also changes. Therefore, there is need for a method of accurately measuring the level change in the storage tank. In the case of general cryogenic fluids, it is difficult to accurately measure the level because the dielectric constant is very low. As a method of measuring cryogenic fluids level with low dielectric constant, it can be used an Millimeter wave (MM wave) FMCW radar sensor. However, the signal sensitivity is very weak and the level accuracy is poor. In this paper, the signal sensitivity is improved by designing the horn lens antenna of the existing 80 GHz FMCW radar sensor. Horn lens antenna is fabricated by FDM/SLA type 3D printer according to horn and lens characteristics. The horn is used to increase the signal gain and the lens improves the signal straightness. This makes it possible to measure the level of cryogenic fluids with a low dielectric constant.

적외선 우주망원경 냉각시스템 열설계 및 열침입량 측정 (Thermal Design and Heat Load Measurement of PSICS)

  • 양형석;김동락;이병섭;최연석
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.43-46
    • /
    • 2005
  • A Protomodel Space Infrared Cryogenic System (PSICS) cooled by a stirling cryocooler was designed. The PSICS has an IR sensor inside a cold box which is cooled by a stilting cryocooler with refrigeration capacity of 500mw at 80K in a vacuum vessel. It is important to minimize heat load for reducing background thermal noise. In order to design the cryogenic system of low heat load and to reduce heat load, we did several numerical analyses and tested using boil-off calorimetry with liquid nitrogen to measure the heat leak of the system. In this paper, we present the results obtained by thermal analysis and heat load measurement for designing the PSICS.

The latest trend in magnetocardiogram measurement system technology

  • Lee, Y.H.;Kwon, H.;Kim, J.M.;Yu, K.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권4호
    • /
    • pp.1-5
    • /
    • 2020
  • Heart consists of myocardium cells and the electrophysiological activity of the cells generate magnetic fields. By measuring this magnetic field, magnetocardiogram (MCG), functional diagnosis of the heart diseases is possible. Since the strength of the MCG signals is weak, typically in the range of 1-10 pT, we need sensitive magnetic sensors. Conventionally, superconducting quantum interference devices (SQUID)s were used for the detection of MCG signals due to its superior sensitivity to other magnetic sensors. However, drawback of the SQUID is the need for regular refill of a cryogenic liquid, typically liquid helium for cooling low-temperature SQUIDs. Efforts to eliminate the need for the refill in the SQUID system have been done by using cryocooler-based conduction cooling or use of non-cryogenic sensors, or room-temperature sensors. Each sensor has advantage and disadvantage, in terms of magnetic field sensitivity and complexity of the system, and we review the recent trend of MCG technology.

극저온(20K) 수소동위원소 흡착 등온선의 온도 변화에 대한 자동 저온 부피 교정 (Automated Cold Volume Calibration of Temperature Variation in Cryogenic Hydrogen Isotope Sorption Isotherm)

  • 박재우;오현철
    • 한국재료학회지
    • /
    • 제29권5호
    • /
    • pp.336-341
    • /
    • 2019
  • The gas adsorption isotherm requires accurate measurement for the analysis of porous materials and is used as an index of surface area, pore distribution, and adsorption amount of gas. Basically, adsorption isotherms of porous materials are measured conventionally at 77K and 87K using liquid nitrogen and liquid argon. The cold volume calibration in this conventional method is done simply by splitting a sample cell into two zones (cold and warm volumes) by controlling the level sensor in a Dewar filled with liquid nitrogen or argon. As a result, BET measurement for textural properties is mainly limited to liquefied gases (i.e. $N_2$ or Ar) at atmospheric pressure. In order to independently investigate other gases (e.g. hydrogen isotopes) at cryogenic temperature, a novel temperature control system in the sample cell is required, and consequently cold volume calibration at various temperatures becomes more important. In this study, a cryocooler system is installed in a commercially available BET device to control the sample cell temperature, and the automated cold volume calibration method of temperature variation is introduced. This developed calibration method presents a reliable and reproducible method of cryogenic measurement for hydrogen isotope separation in porous materials, and also provides large flexibility for evaluating various other gases at various temperature.

기계적/전기적 측정 센서를 이용한 Kogas Pilot LNG 저장탱크 멤브레인 변형 거동 측정(I) (The Measurement of Membrane Deformation Behavior in Kogas Pilot LNG Storage Tank by the use of Mechanical/Electrical Sensor (I))

  • 김영균;오병택;윤인수;김지훈;김석순;홍성호
    • 한국가스학회지
    • /
    • 제7권3호
    • /
    • pp.13-17
    • /
    • 2003
  • LNG 저장탱크의 주요 구조인 멤브레인은 LNG 누설을 방지하기 위하여 설계되었다. 멤브레인 유닛은 $-162^{\circ}C$의 액화시킨 LNG의 접촉에 따라 발생하는 가스압, 액압, 그리고 열하중을 지지하도록 설계되므로 멤브레인 구조의 강도를 실험적 방법을 이용하여 측정하는 것이 매우 중요하다. 본 논문에서는 상용 전기저항식 스트레인 게이지와 자체적으로 제작한 기계적 열 변형 측정 장치를 이용한 변형 측정 시스템을 제안하였다.

  • PDF