• Title/Summary/Keyword: Cryogenic insulation

Search Result 176, Processing Time 0.026 seconds

Effects of Pressure on the Breakdown Characteristics of Cryogenic Liquid and Gaseous Nitrogen (극저온 액체 및 기체 질소의 압력에 따른 절연파괴 특성)

  • 백승명;정종만;김상헌
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.1-4
    • /
    • 2002
  • Electrical properties of liquid nitrogen ($LN_2$) and gaseous nitrogen($GN_2$) have become of great interest again since the discovery of high temperature superconductors . It is very important from a point of superconducting apparatus protection to elucidate breakdown characteristics in $LN_2$ and $GN_2$ at atmospheric and pressurized conditions Therefore. this paper studies the effect of pressure on the breakdown characteristics in $LN_2$ and $GN_2$. Af high voltage is applied to electrode system with uniform and non-unform field in various gap length. And Breakdown voltages of $LN_2$ and $GN_2$ are investigated under AC voltage for Pressure ranging from 0 and 0.5 MPa. This research presented basis information of electrical insulation design for liquid nitrogen immersed HTS power apparatus.

Numerical study on Comparison of Self-Pressurization Behavior of Liquid Nitrogen Cryostat for Umbilical Cord Blood Storage System Design

  • Mahfud, M.I.;Phil, K.E.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.409-414
    • /
    • 2009
  • Since cryogens are stored at very low temperatures, the cryogenic storage systems are quite sensitive to heat leaks. Even though the vessel operated under sealed condition with vacuum insulation and reflective coatings are used, the heat leakage into the vessel is still unavoidable. Therefore, this paper concerns with numerical study of self-pressurization used to analysis the optimum design with the variation volume fraction, effect of heat flux and storage pressure of liquid nitrogen. The result shows that as the volume fraction increases, the pressure rise reduces and the relatively at atmosphere pressure is better than the higher one. In addition, higher heat flux leads the pressure rise increases faster than low one. The additional of heat pipe system to reduce the pressure rise rate also has been done. By this comparison, the optimum design for storage umbilical cord blood can be selected.

  • PDF

Design of 22.9kV High Temperature Superconducting Cable Considering AC losses and Stability (교류손실 및 안정성을 고려한 22.9kV 초전도 케이블 설계)

  • Jang, H.M.;Lee, C.Y.;Kim, C.D.;Sim, K.D.;Cho, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1210-1212
    • /
    • 2005
  • High temperature superconducting(HTS) power cable system consists of HTS cable, termination and cryogenic system. And the HTS cable consists of the former, HTS phase conductor, electric insulation, HTS shield and cryostat. Taking the advantage of HTS shield, the cold dielectric has been adopted. The phase conductor and the shield have been designed to minimize the AC loss below 1W/m/phase. The former has been designed to transport the fault current of 25kA, at fault condition. This paper describes the design process of 22.9kV HTS cable considering AC losses at normal state and the stability at fault condition.

  • PDF

Thermal analysis of LNG storage tank for LNG bunkering system (LNG 벙커링용 고효율 LNG 저장탱크 열해석)

  • Yun, Sang-kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.876-880
    • /
    • 2015
  • In 2016, the IMO's new rules for an 80% reduction in NOx emissions in newly built ships will necessitate the use of LNG as a clean fuel. So far, the developed European countries have led the development of LNG bunkering ships and related facilities. An LNG bunkering system stores LNG in a horizontal or vertical IMO "C"-Type tank insulated with perlite powder, and a vacuum in the annular space between the double walls, like the cryogenic liquid nitrogen tank. Current storage tanks have high heat leakage, evaporating over 2.0% daily, and are difficult to build with the required vacuum. A more efficiently insulated storage tank could reduce the evaporation rate. This research carried out thermal analysis on a new effective insulation method that separates high vacuum in the annular space between two tanks with a solid insulation material, such as urethane foam, lining the outer vessel. This highly efficient insulation system obtained an evaporation rate of 0.03% per day under a $10^{-3}torr$ vacuum, and an evaporation rate of 0.11% at $10^{-45}torr$. Even if the space loses its vacuum, the new insulation system showed a lower evaporation rate of 4.12% than the present perlite system of 4.9%. This newly developed tank can increase the efficiency of LNG storage tank and may help keep LNG bunkering systems safe.

Design Considerations on the Standby Cooling System for the integrity of the CNS-IPA

  • Choi, Jungwoon;Kim, Young-ki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.104-104
    • /
    • 2015
  • Due to the demand of the cold neutron flux in the neutron science and beam utilization technology, the cold neutron source (CNS) has been constructed and operating in the nuclear research reactor all over the world. The majority of the heat load removal scheme in the CNS is two-phase thermosiphon using the liquid hydrogen as a moderator. The CNS moderates thermal neutrons through a cryogenic moderator, liquid hydrogen, into cold neutrons with the generation of the nuclear heat load. The liquid hydrogen in a moderator cell is evaporated for the removal of the generated heat load from the neutron moderation and flows upward into a heat exchanger, where the hydrogen gas is liquefied by the cryogenic helium gas supplied from a helium refrigeration system. The liquefied hydrogen flows down to the moderator cell. To keep the required liquid hydrogen stable in the moderator cell, the CNS consists of an in-pool assembly (IPA) connected with the hydrogen system to handle the required hydrogen gas, the vacuum system to create the thermal insulation, and the helium refrigeration system to provide the cooling capacity. If one of systems is running out of order, the operating research reactor shall be tripped because the integrity of the CNS-IPA is not secured under the full power operation of the reactor. To prevent unscheduled reactor shutdown during a long time because the research reactor has been operating with the multi-purposes, the introduction of the standby cooling system (STS) can be a solution. In this presentation, the design considerations are considered how to design the STS satisfied with the following objectives: (a) to keep the moderator cell less than 350 K during the full power operation of the reactor under loss of the vacuum, loss of the cooling power, loss of common electrical power, or loss of instrument air cases; (b) to circulate smoothly helium gas in the STS circulation loop; (c) to re-start-up the reactor within 1 hour after its trip to avoid the Xenon build-up because more than certain concentration of Xenon makes that the reactor cannot start-up again; (d) to minimize the possibility of the hydrogen-oxygen reaction in the hydrogen boundary.

  • PDF

AC loss dependency on the arrangement of the HTS wires in the current limiting module for SFCL (초전도 한류모듈 내 고온초전도 선재 배치에 따른 교류손실 변화)

  • Kim, W.S.;Yang, S.E.;Lee, J.Y.;Kim, H.;Yu, S.D.;Hyun, O.B.;Kim, H.R.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.9-12
    • /
    • 2012
  • Usually, the AC loss from the superconducting element of an SFCL due to the load current is very small because it is composed of the combination of bifilar windings with very small reactance. Although the AC loss is small enough, we should be albe to predict for the design and control of the cryogenic system. In fact, an SFCL for the transmission voltage class may not generate ignorable AC loss because of the inevitable space between the HTS wires for the high voltage insulation and cryogenic efficiency. To measure the AC loss dependency on the space between the 2G HTS wires with the width of 4.4 mm, we prepared an experimental setup which could adjust the distance between the wires. We used two 500-mm length HTS wires in parallel and applied the current in the opposite direction for each wire to simulate a part of a current limiting module for a high voltage SFCL. We also put two couples of voltage taps at the ends of each wire and a cancel coil in the voltage measurement circuit to compensate the reactive component from the voltage taps. In this condition, we varied the distance between the wires to investigate the change of the transport current loss. A similar experimental study with HTS wire with the width of 12 mm is now in progress.

Evaluation of a Prototype SF6 Purification System for Commercialization

  • Seo, Hai-Kyung;Lee, Jeong Eun;Kim, Kwang Sin;Kim, Kyeongsook
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.1
    • /
    • pp.53-58
    • /
    • 2020
  • Korea Electric Power Corporation (KEPCO) uses large amount of SF6, one of the potent greenhouse gases, in electric equipment for electrical insulation. KEPCO is developing SF6 recovery and purification technology to minimize the release of SF6 into the environment, to secure certified emission reduction, and to save purchase cost of new SF6 by reusing the refined SF6. A prototype SF6 purification system using cryogenic solidification technology has been built in demonstration scale. To evaluate the feasibility of the commercialization, the system has been operated to purify large amount of used SF6 in a long-term operation and the performance has been economically evaluated. The system was stable enough for commercial operation such that it was able to purify 5.4 tons of used SF6 from power transmission equipment in 2-month operation. Over 99% of the SF6 was recovered from the used gas and the purity of the purified gas was over 99.7 vol%. The operation cost, which is the cost of refrigerant (liquid nitrogen), electricity and labor, per kilogram of purified SF6 was 6,526 KRW. Considering the price of new SF6 in Korea is about 15,000 KRW per kilogram this year, about 56% of the purchase cost can be saved.

Assessment of Cryogenic Material Properties of R-PUF Used in the CCS of an LNG Carrier

  • Song, Ha-Cheol
    • Journal of Ocean Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.217-231
    • /
    • 2022
  • Reinforced polyurethane foam (R-PUF), a material for liquefied natural gas cargo containment systems, is expected to have different mechanical properties depending on its stacking position of foaming as the glass fiber reinforcement of R-PUF sinks inside R-PUF under the influence of gravity. In addition, since R-PUF is not a homogeneous material, it is also expected that the coordinate direction within this material has a great correlation with the mechanical properties. So, this study was conducted to confirm this correlation with the one between the mechanical properties and the stacking position. In particular, in this study, R-PUF of 3 different densities (130, 170, and 210 kg/m3) was used, and tensile, compression, and shear tests of this material were performed under 5 temperatures. As a result of the tests, it was confirmed that the strength and modulus of elasticity of the material increased as the temperature decreased. Specifically, the strength and modulus of elasticity in the Z direction, which was the lamination direction, tended to be lower than those in the other directions. Finally, the strength and elastic modulus of different specimens of the material found at the bottom of their lamination compared to the specimens with these properties found at positions other than their lamination bottom were evaluated. Further analysis confirmed that as the temperature decreased, hardening of R-PUF occurred, indicating that the strength and modulus of elasticity increased. On the other hand, as the density of R-PUF increased, a sharp increase in strength and elastic modulus of R-PUF was observed.