• Title/Summary/Keyword: Crown to root ratio

Search Result 49, Processing Time 0.032 seconds

Effect of Plant Density on Growth Responses and Yield in Yacon

  • Ryu, Jeom-Ho;Doo, Hong-Soo;Lee, Kang-Soo;Park, Sun-Young
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.46 no.5
    • /
    • pp.407-410
    • /
    • 2001
  • This study was conducted to determine the optimal planting distance in cultivation of yacon (Polymnia sonchifolia Poeppig & Endlicher). Plug seedlings were planted with 6 different plant densities of 80 $\times$ 60, 80 $\times$ 50, 70 $\times$ 50, 70 $\times$ 45, 70 $\times$ 40 and 60 $\times$ 45 cm. The plant height and the petiole length were increased with increasing the planting distance. The tallest plant height of yacon was 165.4cm with the plant density of 80 $\times$ 60 cm. However, branch number per plant, leaf number on main stem and stem diameter were not significantly difference among planting densities. Tuberous root was harvested 31.42 tons/ha in 70 $\times$ 50 cm spacing. The ratio of heavier tuberous roots than 200 g to total tuberous roots decreased significantly according to increase of planting density. Fresh weights of shoot and root, contain the crown bud, were decreased, as planting distance was shorter. Tuberous root number was fewer but its weight was heavier in wide planting than in dense planting. We think that optimal planting density is about 30,000 plants/ha, if it were to be 70 cm row spacing, intrarow spacing should calculate about 47cm.

  • PDF

A Clinical Study on The Truss Bar-Joint Removable Denture (I) (Truss Bar-Joint denture의 임상적 응용에 관한 연구(I))

  • Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.22 no.1
    • /
    • pp.7-15
    • /
    • 1984
  • A rationale and compendium of treatment for a specific situation of cases have been presented. It consists of a cast metal bar called a truss bar joint removable denture which is soldered to crowns and dowel core on a few remaining teeth, i.e., cuspids or bicuspids. This system gives additional support and retention to the individual teeth and makes possible a more stable removable denture. It is my opinion that the prognosis of the chosen cases may be obtained Successful results when applied on the teeth of less favorable crown-root ratio.

  • PDF

An Analytical Study on Strain Distribution Using Strain Gauge Attached On Root Surface (치근 부착 스트레인 게이지를 이용한 응력 분포 분석)

  • Kim, Sang-Cheol;Park, Kyu-Chan
    • The korean journal of orthodontics
    • /
    • v.31 no.3 s.86
    • /
    • pp.325-333
    • /
    • 2001
  • Optimal orthodontic treatment could be possible when a orthodontist can predict and control tooth movement by applying a planned force system to the dentition. The moment to force(M/F) ratio at the bracket, has been shown to be a primary determinate of the pattern of tooth movement. As various n/F ratios are applied to the bracket on the tooth crown, strain distribution in periodontium can be changed, and the center of rotation in tooth movement can be determined. It is, therefore, so important in clinicalorthodontics to know the strain distribution in a force system of a M/F ratio. The purpose of this study was to analyze the strain distribution in orthodontic force system by strain gauge attached to tooth root, and to evaluate the usage of the method. For this study, an experimental upper anterior arch model was constructed, where upper central incisors, on the root surface of which, 8 strain gauges were attached, were implanted In the photoelastic resin, as in the case of 4mm midline diastema. Three types of closing of upper midline diastema closure were compared : 1. with elastomeric chain(100g force) in no arch wire, 2. elastomeric chain in .016“ round steel wire, 3. elastomeric chain in .016”x.022“ rectangular steel wire. The results were as follows. 1. Strain distributions on labial, lingual, mesial and distal root surface of tooth were able to be evaluated with the strain gauge method, and the patterns of tooth rotation were understood by presuming the location of moment arm. 2. Extrusion and tipping movement of tooth was seen in closing in no arch wire, and intrusion and bodily movement was seen with steel arch wire inserted.

  • PDF

A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS (엔진구동형 NiTi 파일의 근관성형효과 비교)

  • Kim, Bo-Hye;Choi, Kyoung-Kyu;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.88-95
    • /
    • 2010
  • The purpose of this study was to compare the root canal shaping ability of 4 rotary NiTi instruments in simulated root canals. For the preparation of thirty two curved root canals, Mtwo instruments using "single length"technique, and Profile, ProTaper Universal, and K3 using crown-down technique (N = 8) were used. All canal samples were prepared by reaching an apical canal size of #30. Pre- and post-instrumentation digital images were recorded and an assessment of canal shape was determined using a computer image analysis program SigmaScan Pro (Systat Software Inc., San Jose, CA, USA). The changes of the dimension of inner walls of canals, (2) the changes of the dimension of outer walls of canals, and (3) the centering ratio were measured at 7 measuring points, and then data were statistically analyzed using one-way ANOVA and Duncan's test. The results were as below; 1. The root canal shaping ability of Profile was significantly faster than that of other rotary NiTi instruments (p < 0.05). 2. The deformation and fracture of all instruments used for this study were not experienced. 3. In the degree of changes of the dimension of inner walls of canals, Profile demonstrated the lowest changes of the dimension of inner walls of canals except at the measuring points of the 1 and 2 mm (p < 0.05). However, the ProTaper Universal showed the highest changes of the dimension of inner walls of canals at all measuring points (p < 0.05). 4. In the degree of changes of the dimension of outer walls of canals, Mtwo demonstrated the lowest changse of the dimension of outer walls of canals except at the measuring point of the 1 mm (p < 0.05). However, Profile exhibited the highest changes of the dimension of outer walls of canals at the measuring points of 3 and 4 mm and ProTaper Universal and K3 showed the largest changes of the dimension of outer walls of canals at the measuring points of 1, 2, 6, and 7 mm (p < 0.05). 5. In degree of centering ratio, Profile demonstrated the least centering ratio comparing with the centering ratio shown by other NiTi instruments at the measuring points of 1, 4, 5, and 6 mm. Results suggest that in the coronal part of canal preparation, active cutting files such as ProTaper Universal may efficiently flare the canal orifice and form a better taper, and in the apical part of the canal, files which have a better centering ability such as Profile may maintain the original canal curvature and reduce the shaping time.

A CLINICAL STUDY ON THE ATTACHMENT-FIXATION OVERDENTURE (I) - Preliminary Periodontal Status Study - (ATTACHMENT-FIXATION OVERDENTURE에 관한 임상적 연구(I))

  • Yang, Jae-Ho
    • The Journal of the Korean dental association
    • /
    • v.22 no.11 s.186
    • /
    • pp.953-960
    • /
    • 1984
  • The author applied the attachment fixation overdenture on the patient whose residual alveolar ridge height was poor to increase mechanical denture retention, and observed the periodontal condition of the abutment roots after insertion of attachment fixation overdenture. The author obtained the conclusions as follows; 1. Attachment fixation overdenture showed better mechanical retention than conventional overdenture did, but it resulted unfavorable crown-root ratio. 2. Within one year after insertion, there were not significant changes in periodontal health, which was indicated by plaque index, gingival index, pocket depth, tooth mobility gingival hyperplasia and alveolar bone change. 3. Mild periodontal thickening was observed. 4. This study emphasized the importance of adequate follow-up care and home care instructions.

  • PDF

BILATERALLY PRIMARY FIRST MOLARS WITH SINGLE ROOT (단일 치근을 가진 하악 제1유구치)

  • Yoon, Sang-Il;Kim, Sung-Oh;Lee, Jae-Ho;Son, Heung-Kyu;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.701-704
    • /
    • 2004
  • In this case, we would like to discuss about the single rooted deciduous mandibular first molar. The deciduous mandibular molar of a five years old boy was shown to have a single root, bilaterally. Ordinarily, the maxilary molars have three roots and the mandibular molars have two roots. However, when the hertwig's epithelial root sheath do not invaginate properly during tooth development, root fusion can occur from the absence of root separation. Molars with fused roots not only have unfavorable crown to root ratio, but also according to many reports, have higher probability of having multiple congenitally missing teeth or dens invaginatus in the maxillary incisors, consequently requiring preventive dental treatment In addition, disorders such as ectodermal dysplasia, syndactyly, clinodactyly, bluish sclera can also be related to this condition. Root fusion is known to be of autosomal recessive inheritance. Up to date, single rooted molars have been reported several times in permanent dentitions but hardly in deciduous dentition, which is the motive for this paper.

  • PDF

THE EFFECT OF SMEAR LAYER TREATMENT ON THE MICROLEAKAGE (Smear layer 처리에 따른 미세누출에 대한 연구)

  • Lee, Jung-Min;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.378-389
    • /
    • 2006
  • The purpose of this study was to compare the sealing ability of root canal obturation with or without the treatment of smear layer. Eighty extracted human teeth with one canal were selected Instrumentation was performed with crown-down technique. After instrumentation, root canals of the NaOCl group and NaOCl-6 group were irrigated with 3% NaOCl. EDTA group and EDTA-6 group were irrigated with 17% EDTA. Then all teeth were obturated using continuous wane obturation technique NaOCl group and EDTA group were immersed in methylene blue solution for 84hours. NaOCl-6 group and EDTA-6 group were immersed in methylene blue solution for 6months. The teeth were sectioned at 1.5 mn (Level 1), 3.0 mm (Level 2) and 4.5 mm (Level 3) from the root apex. The length of dye-penetrated inter-face and the circumferential length of canal at each level were measured using Sigma-Scan Pro 5.0. 1. The mean leakage ratio was decreased cervically. 2. NaOCl group showed higher mean leakage ratio than EDTA group at each level. But there was significant difference at level 1 only (p < 0.05). 3. NaOCl-6 group showed higher mean leakage ratio than EDTA-6 group at each level. But there was significant difference at level 1 only (p < 0.05). 4. NaOCl-6 group showed higher mean leakage ratio than NaOCl group at each level. But there was significant difference at level 1 only (p < 0.05). 5. EDTA-6 group showed higher mean leakage ratio than EDTA group at each level. But there was no significant difference. 6. In NaOCl group and NaOCl-6 group, scanning electron micrographs of tooth sections generally covered with smear layer. In EDTA group and EDTA-6 group, tooth sections showing the penetration of sealers to opened dentinal tubules. The results suggest that removal of smear layer was effective to reduce the apical microleakage of the root canal.

Morphological Characters of Superior Populus alba × Populus glandulosa F1 Clones under Intensive Culture (밀식재배(密植栽培)한 제일대(第一代) 잡종(雜種)포플러, Populus alba × Populus glandulosa F1 우량(優良)클론의 형태학적(形態學的) 형질(形質)에 관한 연구(硏究))

  • Lee, Kyeong Hack;Lee, Don Koo
    • Journal of Korean Society of Forest Science
    • /
    • v.64 no.1
    • /
    • pp.1-10
    • /
    • 1984
  • Two fast-growing clones 65-29-19 and 66-6-8 and two less fast-growing clones 66-14-29 and 66-14-99 were compared at intensively cultured plots to identify what morphological characters are related to fast growth and high biomass yield of Populus alba ${\times}$ Populus glandulosa $F_1$. The plantations were established in the spring of 1982 and 1983 at the Seoul National University nursery in Suweon. Differences in dry matter production were found among two-year-old clones but not, among one-year-old clones. Highly significant correlations were found between total leaf area per tree and total dry weight per tree and between total branch length per tree and total dry weight per tree for two-year-old clones. This relation was more obvious during the late growing season. Morphological characters desirable for producing high biomass identified in fast-growing clones were as follows; high shoot-root ratio, high leaf surface area per tree, long leaf retention period, and many small leaves and compact crown architecture in the upper portion of true crown.

  • PDF

Comparison of shaping ability between single length technique and crown-down technique using Mtwo rotary file (Mtwo 전동 파일을 사용한 single length technique과 crown-down technique의 근관성형 효율 비교)

  • Lim, Yoo-Kyoung;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.385-396
    • /
    • 2007
  • The aims of this study were to compare the shaping effect and safety between single length technique recommended by manufacturer and crown-down technique using Mtwo rotary file and to present a modified method in use of Mtwo file. Sixty simulated root canal resin blocks were used. The canals were divided into three groups according to instrument and the manner of using methods. Each group had 20 specimens. Group MT was instrumented with single length technique of Mtwo, group MC was instrumented with crown-down technique of Mtwo and group PT was instrumented with crown-down technique of ProTaper. All of the rotary files used in this study were operated by an electric motor. The scanned canal images of before and after preparation were superimposed. These superimposed images were evaluated at apical 1 to 8 mm levels Angle changes were calculated. The preparation time, weight loss, instrument failure and binding, canal aberrations, and centering ratio were measured. Statistical analysis of the three experimental groups was performed with ANOVA and Duncan's multiple range tests for post-hoc comparison and Fisher's exact test was done for the frequency comparison. In total preparation time, group MT and group MC were less than group PT. In the aberrations, group MT had more elbows than those of group MC and group PT. The binding of group MC was least and group MT was less than group PT (P < 0.05). Under the condition of this study, crown-down technique using Mtwo rotary file is better and safer method than single length technique recommended by the manufacturer.

A Study on the Shaping Ability of Three Different Rotary Nickel-Titanium Instruments in Simulated Curved Root Canal (만곡 근관에서 다양한 엔진 구동형 Nickel-Titanium 파일의 근관 성형능력에 대한 연구)

  • Kim, Kyoung-A;Chon, Seong-Min;Kwon, Su-Mi;Lee, Kwang-Won;Yu, Mi-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.293-302
    • /
    • 2007
  • I. Objectives The purpose of this study was to compare the shaping ability between the single length technique performed with Mtwo instruments (VDW, Munich, Germany) and the crown-down technique using K3 (SybronEndo, West Collins, CA, USA) and RaCe (FKG, La Chaux-de-Fonds, Switzerland) instruments. II. Materials & Methods Forty five curved canals in resin blocks were equally divided in to three groups. Group 1 (Mtwo) was instrumented used the full length of canal according to the manufacturer's instructions. The simulated canals was prepared to an instrument size of 35, 0.04 taper canal terminus. In group 2 (Race) and group 3 (K3) was instrumented in a crown-down manner and prepared to an instrument size of 30, 0.06 taper canal terminus. Pre- and post-instrumentation images were scanned and assessment of canal shape was completed with a computer image analysis program. Material removal was measured at 7 measuring points, beginning 1mm from the end point of preparation. Differenced of centering ratio were statistically analyzed using One-way ANOVA followed by Duncan's test. II. Results & Conclusion There was no significant difference on 1, 2, 3 and 7mm measuring point. At 4 and 5 measuring point, significant difference showed between the Mtow instruments and other two instruments. (p<0.05)