• Title/Summary/Keyword: Crown teeth

Search Result 568, Processing Time 0.03 seconds

A clinical case of hybrid telescopic double crown using friction pin with an isolated few remaining teeth (고립된 소수 잔존치 환자에서 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관 국소의치의 임상증례)

  • Sohn, Sang-Hyuk;Cho, Jin-Hyun;Cho, Sung-Am
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.80-86
    • /
    • 2016
  • A few authors have reported good clinical results using double crown removable partial denture (RPD) with a few remaining teeth. Hybrid telescopic double crown is a good indication for a patient with poor periodontal condition and/or few remaining teeth after extraction, especially located in cross-arch position. In this case, there was a poor periodontal condition with teeth mobility. Several teeth with poor prognosis were extracted. Remaining anterior teeth was restored with fixed prostheses and edentulism was restored with Kennedy class I removable partial denture in maxilla. In mandible, it was hard to restore with clasp removable partial prostheses because of bilaterally isolated remaining teeth so that hybrid double crown removable partial denture with friction pin was suitable for this case. The objective of this report is to discuss the characteristics and the utility of hybrid double crown prostheses using a few remaining teeth in mandible.

GLASS FIBER REINFORCED STRIP CROWN IN PRIMARY TEETH (강화형 strip crown의 사용)

  • Kim, Dae-Eop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.132-135
    • /
    • 2005
  • The purpose of this study was to propose the modified strip crown technique for esthetic restoration of primary anterior teeth using glass fibers. Celluloid crown form(3M, USA), Z100(P shade, 3M, USA). Aeliteflo(Bisco Inc., USA), and Clearfil SE Bond(Kuraray Medical Inc., Japan) were used for this technique. Mesh type of glass fiber(TESCERA Fiber Mesh, Bisco Inc, USA) was used for reinforcing material. After trimming the celluloid crown form, resin adhesive and flowable resin were applied on the pre-shaped glass fiber mesh. That mesh was placed on the lingual surface of inside of celluloid crown form and followed by light activation. Composite resin was filled into the celluloid crown form and put it on a prepared tooth and then light activated and finished the margin. The new modified strip crown technique can provide esthetics and increased durability for restoration of primary anterior teeth.

  • PDF

Clinical outcomes of rigid and non-rigid telescopic double-crown-retained removable dental prostheses: An analytical review

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.1
    • /
    • pp.38-48
    • /
    • 2020
  • PURPOSE. The objective of this literature review was to analyze the cumulative survival rates (CSRs) of rigid and non-rigid double-crown-retained removable dental prostheses. MATERIALS AND METHODS. Screening of the literature published from January 1995 to December 2019 was performed by using electronic data base (Pubmed) and manual search. The CSRs of rigid and non-rigid double crown removable dental prostheses were investigated. RESULTS. A total of 403 articles were reviewed and 56 relevant articles of them were selected. Subsequently, 25 articles were included for data extraction. These articles were classified according to rigid and non-rigid type double crowns and further subdivided into teeth, implants, and teeth-implant combination types. The CSRs of rigid type double crown ranged from 68.9% to 95.1% of 5 to 10 years in tooth abutments, 94.02% to 100% over a 3-year mean observation periods in implant abutments, and 81.8% to 97.6% in tooth-implant combination. Non-rigid type double crowns had various CSR ranges from 34% to 94% maximum during 10 years observation in teeth abutment. The CSRs of non-rigid type had over 98% in implant abutments, and ranged from 85% to 100% in tooth-implant combination. CONCLUSION. The CSRs of double crowns varies according to types. With accurate evaluation of the remaining teeth and plan of the strategic implant placement, it could be successful treatment alternatives for partially or completely edentulous patients.

Volume difference in upper central incisor preparation according to the changes of restorative design and marginal location (상악 중절치 삭제 시 수복 디자인과 변연부 위치에 따른 부피 변화)

  • Kim, Chong-Hyun;Park, Young-Bum;Kim, Sung-Tae;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.152-160
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the volumetric change of teeth after preparation for various designs and margin locations through Micro CT analysis (Skyscan 1076: SKYSCAN, Konitch, Belgium). Materials and methods: The 36 artificial teeth were used to determine reduction volume of upper central incisor. According to the restorative design these 36 teeth were divided into 4 groups and according to the marginal location each group was divided into 3 subgroups. The volume of unprepared teeth was obtained by using Micro CT and the volume of prepared teeth was obtained in the same method. The CT scanned images before and after preparation were superimposed. Results: The volume difference was significantly increased as follows: traditional laminate veneer < full laminate veneer < all ceramic crown < metal ceramic crown. One-way ANOVA and Tukey multiple comparison analyses were used to analyze the data in this study. In each group the volume difference was significantly increased as follows: 1 mm above CEJ < CEJ < 1 mm below CEJ (P<.05). The % volume difference of all ceramic crown and metal ceramic crown was 31 - 48% and that of laminate veneer was 14 - 30%. The volume difference of the traditional laminate veneer was 1/3 of that of metal ceramic crown. The full laminate (1 mm below CEJ) and all ceramic crown (1 mm above CEJ) showed a similar volume difference. Metal ceramic crown showed 13.7% more volume difference than all ceramic crown. Conclusion: There exists the difference in volumetric change according to designs of restoration and margin locations of preparation.

Hybrid telescopic double crown denture on maxillary few remaining teeth and 2 mandibular implants in case of failed implant overdenture (상악의 소수 잔존치와 실패한 하악의 임플란트 오버덴처의 재수복 임상증례: 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관법)

  • Ha, Seok-Joon;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.246-252
    • /
    • 2016
  • Double crown prostheses can be used in patients who have a few remaining teeth and poor periodontal condition because of secondary splinting of abutments, vertical loading, decrease of the length of lever arm due to fulcrum line located on margin of inner and outer crown. Successful results of treatments using double crown prostheses for the partially edentulous patients who have a few remaining teeth and implant overdenture using a small number of implants have been reported. In this case, there were a few remaining teeth with a very poor periodontal condition in maxilla, and there were a failed implant with severe alveolar bone resorption and shrinkage in the mandible. The main objective of this report is to introduce our case because a double crown partial denture showed satisfactory results in functional and esthetical aspects during more than one-year follow-up period.

Causes of failures of long-term used double crown denture and new rehabilitation with dental implant and tooth combined denture using remaining teeth and implants (장기간 사용한 이중관 의치의 실패원인 및 자연치와 임플란트를 이용한 이중관 의치 수복증례)

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.384-390
    • /
    • 2018
  • Hybrid telescopic double crown have ever been good treatment option for patient with periodontally unfavorable few remaining teeth for successful prognosis. Tooth and implant combined telescopic double crown can be used for improving retention and support for denture with strategically placed implants on edentulous ridge. In this case, an 55-year-old female patient had chronic periodontitis with few remaining teeth on maxilla and fixed partial prosthodontics on mandible. Treatment of hybrid telescopic double crown with friction pin lasted 9.5 years only with natural teeth. After 9.5 years, additional implants was installed due to fracture of cast-posted abutment teeth. After implantation, tooth and implant combined double crown had fabricated. Through re-treatment, no complications of new denture has been found during 2 years follow up. This case presents fair prognosis of tooth and implant combined double crown denture in periodontally unfavorable condition.

Clinical Report by using hybrid telescopic double crown Removable Partial Denture on a few remaining teeth with severe periodontal disease (치주적으로 불리한 소수 잔존치에서 하이브리드 텔레스코픽 이중관 국소의치를 이용한 임상증례)

  • Seo, Jang-Won;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.24-30
    • /
    • 2019
  • The successful results of the treatment using a double crown denture have been reported in several papers for some of the few remaining teeth in patient. In particular, double crown dentures may be an alternative to treatment in cases where the periodontal status is poor and clasp type removable partial dentures are inappropriate (crown/root ratio > 1). In this case, the patient visited clinic with a chief complaint of difficulty in mastication due to loss of posterior teeth and overall teeth mobility. After teeth with severe periodontitis were extracted, treatment plan of mandible is Kennedy class I removable partial denture (RPD) and treatment plan of maxilla is hybrid telescopic double crown RPD with a friction pin. Patient is well adapted after the prosthetic treatment and we report due to achieving satisfactory results in pronunciation, mastication, retention and aesthetics.

A STUDY ON THE SIZE OF THE DECIDUOUS TEETH (유치의 치아크기에 관한 연구)

  • Baik, Byeong-Ju;Jeon, So-Hee;Kim, Jae-Gon;Kim, Young-Sin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.382-388
    • /
    • 2002
  • In the present study, crown diameters and their sexual differences in deciduous teeth were investigated in children of Chon-ju city, Korea. Plaster casts of the deciduous dentitions obtained from 50 boys and 50 girls were examined. Mesiodistal and buccolingual crown diameters were measured using a digital caliper(0.01mm) according to the definitions of Seipel and Moorees et al. These measurements were performed three times, and intra-observer measurement errors were calculated by the single determination method. The crown index, module and area were calculated in order to provide a comparison of crown proportions. The results obtained were summarized as follows; 1. The mean values of intra-observer measurement errors were 0.255mm and are unlikely to have influenced the statistical analysis. 2. The mean values of mesiodistal and buccolingual crown diameters examined were larger in boys than girls. 3. The mean coefficient of variation was 5.6 in the deciduous dentition. There were a trend for the primary second molar to be the least variable in size of all teeth both in boys and girls. 4. Fluctuating asymmetry is the difference between left and right antimeres in individuals. Primary second molars were less asymmetrical than primary first molars in both dimensions. 5. In maxillary teeth, Crown index is larger in boys than in girls. In contrast, in mandibular teeth, except primary canine, it is larger in girls than in boys. Crown module is larger in boys than in girls and increased progressively from primary first incisor to primary second molar. Crown area is consistently larger in boys than in girls. The minimum crown area is mandibular primary incisor and maximum crown area is maxillary primary second molar.

  • PDF

Periodontal prosthesis on medically compromised patient with few remaining teeth: hybrid telescopic double crown with friction pin method (의과적 문제가 있고 소수 잔존치를 가지는 환자에서의 치주보철 임상증례: 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관법)

  • Ha, Seok-Joon;Lee, Cheong-Hee;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.359-365
    • /
    • 2014
  • Successful results of treatments using double crown prostheses for the partially edentulous patients who have a few remaining teeth have been reported in several journals. A double crown removable partial denture can be an alternative treatment for the patients with a poor periodontal condition of remaining teeth. Since a double crown removable partial denture can be applied without the risk of surgical operation to the medically compromised patients with a poor periodontal condition which is inadequate for dental implants, it has psychological and economical advantages. In this case, there were sufficient remaining teeth to be restored with fixed prostheses in maxilla, while there were a few remaining teeth with a very poor periodontal condition so that it was almost impossible to restore with a clasp removable partial denture using these remaining teeth in mandible. In addition, the patient had the medical history of surgical operation due to osteomyelitis in the mandibular anterior areas a year ago, thus difficult to conduct an implant placement. The main objective of this report is to introduce our case because a double crown partial denture using a few mandibular remaining teeth showed satisfactory results in functional and esthetical aspects during more than two years follow-up period in this unfavorable condition.

Crown-root angulations of the maxillary anterior teeth according to malocclusions: A cone-beam computed tomography study in Korean population

  • Lee, Kyoung-Hoon;Choi, Dong-Soon;Jang, Insan;Cha, Bong-Kuen
    • The korean journal of orthodontics
    • /
    • v.52 no.6
    • /
    • pp.432-438
    • /
    • 2022
  • Objective: To compare crown-root angulations of the permanent maxillary anterior teeth in skeletal Class I, Class II, and Class III Korean malocclusion patients using cone-bean computed tomography (CBCT) images. Methods: Sixty CBCT images were collected from orthodontic patients archive based on skeletal Class I (0˚< A point-nasion-B point angle [ANB] < 4˚), Class II (ANB ≥ 4˚), and Class III (ANB ≤ 0˚) to have 20 samples in each group. Mesiodistal crown-root angulation (MDCRA) and labiolingual crown-root angulation (LLCRA) were evaluated after orientation of images. Crown-root angulations were compared among Class I, Class II, and Class III groups and among the maxillary anterior teeth in each group. Results: LLCRAs of the maxillary central incisor and the lateral incisor were significantly lower in Class III group than those in Class I group. However, those of the canine showed no significant differences among groups. MDCRAs of the maxillary anterior teeth did not significantly differ among groups either. Conclusions: Our results suggest that skeletal Class III malocclusion might affect LLCRA of the maxillary incisors, especially the central incisor.