• 제목/요약/키워드: Crown length

검색결과 354건 처리시간 0.03초

외과적 정출술을 이용한 치관-치근 파절된 미성숙 영구치의 치료: 3년 간의 증례보고 (Surgical extrusion of immature permanent tooth with crown-root fractures: a case report with 36-month follow up)

  • 전수진
    • 대한치과의사협회지
    • /
    • 제57권11호
    • /
    • pp.679-688
    • /
    • 2019
  • A 8-year-old patient presented with a crown-root fracture of the maxillary right central incisor with an oblique subgingival fracture line. A multidisciplinary treatment approach including endodontic treatment, surgical extraction and intraalveolar repositioning was used to gain sufficient crown length of the fractured maxillary incisor. The coronally repositioned maxillary right central incisor was stabilized by a resin wire splint. Apexification using MTA was performed. Resin core and direct resin restoration(Cl IV) on fractured teeth was built up. Clinical and radiographic follow-up of the maxillary right central incisor after 36 months showed no signs of root resorption or pathology and acceptable aesthetics and functions were maintained. Surgical extrusion can be considered as a good treatment modality for young patients.

  • PDF

일반인과 일부 치위생과 학생들의 상악 전치부 심미 선호도 (Perception of Maxillary Anterior Esthetics by General Public and Dental Hygiene Student of the Specific College)

  • 이병호
    • 치위생과학회지
    • /
    • 제7권3호
    • /
    • pp.201-205
    • /
    • 2007
  • 부산 시내에 소재하는 1곳의 치과의원에 치료를 위해 내원한 111명의 환자와 D대학 치위생과에 재학 중인 학생 105명을 대상으로, 상악 전치부 치은선에 대한 심미 선호도를 조사한 본 연구에서 얻은 결론은 다음과 같다. 두 그룹 간에 상악 전치부 치은선에 대한 심미 선호도 차이는 없었다. 측절치 치은변연의 위치에 대해 측절치 변연이 중절치보다 0.5 낮은 형태를 선호하였다. 중절치 치은선의 형태에서 수평선분의 접촉량이 1/9인 형태를 선호하였다. 인접 접촉점의 길이에서 치관 길이의 1/2이 접촉하는 형태를 선호하였다. 이런 결과는 치과의료기관에서 실제 환자의 치아 및 치은 수복시 이용할 수 있는 심미적 치은선 형태에 관한 기초자료로 도움이 되리라 사료된다.

  • PDF

초음파를 이용한 임신초기 태아의 두개내투명대 표준치 제시 (Design of Standard Value Intracranial Translucency of Fetus in Early Pregnancy Using Ultrasound)

  • 양성희;김창수
    • 한국방사선학회논문지
    • /
    • 제15권2호
    • /
    • pp.131-137
    • /
    • 2021
  • 본 연구는 임신초기 초음파 선별검사에서 태아의 후뇌 정중면을 이용하여 태아의 두개내투명대 기준 값을 제시하고 임상적인 의의를 찾고자 하였다. 2018년 8월부터 2020년 2월까지 I 병원 정기검진을 받는 산모들 중 머리엉덩길이 40.6 mm에서 78.3 mm에 해당되는 단태아 1529명의 두개내투명대를 측정하여 후향적으로 분석하였다. 회귀분석에서 머리엉덩길이가 증가할수록 두개내투명대는 54.3%의 설명력을 보이며 증가하는 경향을 보였다(P<0.001). 또한 빈도분석을 통해 임신주수별 두개내투명대의 백분위수 기준치를 산출하였다. 결과적으로 태아 두개내투명대의 한국인 기준치를 마련할 수 있었으며 임신초기 태아 후뇌의 평가에 있어서 척추이분증의 보조적 선별검사로 유용하게 적용될 것이다.

Clinical predictors of potentially impacted canines in low-risk patients: A retrospective study in mixed dentition

  • Sergio Estelita Barros;Bianca Heck;Kelly Chiqueto;Eduardo Ferreira
    • 대한치과교정학회지
    • /
    • 제53권2호
    • /
    • pp.106-115
    • /
    • 2023
  • Objective: To evaluate the null hypothesis that there is no difference in a set of clinical predictors of potentially impacted canines between low-risk patients with and without displaced canines. Methods: The normal canine position group consisted of 30 patients with 60 normally erupting canines ranked in sector I (age, 9.30 ± 0.94 years). The displaced canine group comprised 30 patients with 41 potentially impacted canines ranked in sectors II to IV (age, 9.46 ± 0.78 years). Maxillary lateral incisor crown angulation, inclination, rotation, width, height, and shape, as well as palatal depth, arch length, width, and perimeter composed a set of clinical predictors, which were evaluated on digital dental casts. Statistical analyses consisted of group comparisons and variable correlations (p < 0.05). Results: There was a significant association between sex and mesially displaced canines. Unilateral canine displacement was more prevalent than bilateral displacement. The crown of the maxillary lateral incisors was significantly angulated more mesially and rotated mesiolabially in low-risk patients with displaced canines, who also had a shallower palate and shorter anterior dental arch length. Lateral incisor crown angulation and rotation, as well as palatal depth and arch length, were significantly correlated with the canine displacement severity. Conclusions: The null hypothesis was rejected. Maxillary lateral incisor angulation inconsistent with the "ugly duckling" stage as well as a shallow palate and short arch length are clinical predictors that can significantly contribute to the early screening of ectopic canines in low-risk patients.

한국인의 안정위시 상악중절치 노출량에 관한 연구 (A study on exposure length of Maxillary central incisor in rest position in Korean)

  • 박준섭;류재준
    • 대한심미치과학회지
    • /
    • 제13권1호
    • /
    • pp.19-24
    • /
    • 2004
  • This study is intended to provide a referable information of exposed amount of maxillary central incisor of Korean by ages and gender under rest position. The result of this study will give guidelines for making prothesis. The subjects of this study are patients of Charmgoun Dental Hospital in Busan, Korea. A statistical analysis was conducted after taking digital photos of patients' teeth with a ruler and measuring the length of teeth on the computer program. The results of this study were as follows : 1. The length of maxillary central incisor that exposed under upper lip is decreased by increasing age in rest position.; the average length is 3.455mm in 20s, 2.525mm in 30s, and 1.543mm in 40s. 2. The exposal length in females is more than males, average length is 2.796mm in female and 2.342mm in male. However, there is not significant difference between the genders. 3. The exposed average length of maxiallry central incisor under upper lip is 2.618mm at rest. 4. The clinical crown average length of maxillary central incisor is 10.195mm, but incresing age, there is no significant defference. 5. There is significant difference between the genders in the clinical crown length of maxillary central incisor.; the length is 10.637mm in men, 9.90mm in women.

  • PDF

폴리머 배터리 전극제조용 압연 고온롤 표면의 형상 및 유한요소 열변형 해석 (Shapes and Thermomechanical Analyses of a Hot Roll for Manufacturing Electrodes of Polymer Batteries)

  • 김철;장동수;유선준
    • 대한기계학회논문집A
    • /
    • 제31권8호
    • /
    • pp.847-854
    • /
    • 2007
  • The battery electrode of a mobile phone is made of layered polymer coated on aluminum foils and the hot rolling process is applied to increase the density per volume of an electrode for a high capacity battery. The flatness of batteries surfaces should be less than $2{\mu}m$. To satisfy the required flatness, the deformation of roll surface due to bending and heating of the roll should be minimized. Complicated hot oil paths of $100^{\circ}C$ inside the roll are required for heating the polymer layers. FEA was used to calculate thermal deformations and temperatures distributions of the roller. Based on FEA, a modified surface curvature called a crown roll was suggested and this gave the area of 30% improved flatness compared with a flat roll. The flat roll satisfied the flatness of $2{\mu}m$ in the length of 340 mm and the crown roll resulted in the longer length of 460 mm. Experiments to measure the temperature distribution and thermal strain were performed and compared with FEA. There were only 6% difference between two results.

연결고정, 인접면 접촉강도 및 치관길이에 따른 엔도포어 임플란트를 이용한 고정성 국소의치의 광탄성 응력 분석 (A PHOTOELASTIC STRESS ANALYSIS OF FIXED PARTIAL DENTURES WITH ENDOPOREIMPLANTS ACCORDING TO SPLINTING, CONTACT TIGHTNESS, AND CROWN LENGTH)

  • 정회열;최민호;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제42권4호
    • /
    • pp.425-442
    • /
    • 2004
  • Statement of problem: A difficulty in achieving a passive-fitting prosthesis can be overcome by individual crown restoation of multiple implants. But individualized crown has another difficulty in control of contact tightness and stress distribution. Purpose: This in vitro study is to evaluate the stress distribution and the magnitude in the supporting tissues around Endopore implants with different crown lengths, interproximal contact tightness, and the splinting effects. Material & methods: Three Endopore implants($4.1{\times}9mm$) were placed in the mandibular posterior edentulous area distal to the canine and photoelastic model was made with PL-2 resin(Measurements Group, Raleigh, USA). Restorations were fabricated in two crown lengths: 9, 13 mm. For non-splinted restorations, individual crowns were fabricated on three custom-milled titanium abutments. After the units were cemented, 4 levels of interproximal contact tightness were evaluated: open, ideal($8{\mu}m$ shim stock drags without tearing), medium($40{\mu}m$), and heavy($80{\mu}m$). For splinted restorations, 3-unit fixed partial dentures were fabricated. This study was examined under simulated non-loaded and loaded conditions(6.8 kg). Photoelastic stress analysis was carried out to measure the fringe order around the implant supporting structure. Results: 1. When restorations were not splinted, the more interproximal contact tightness was increased among the three implants, the more stress was shown in the cervical region of each implant. When crown length was increased, stresses tended to increase in the apex of implants but there were little differences in stress fringes. 2. When nonsplinted restorations were loaded on the first or third implant, stresses were increased in the apex and cervical region of loaded implant. Regardless of interproximal contact tightness level, stresses were not distributed among the three implants. But with tighter interproximal contact, stresses were increased in the cervical region of loaded first or third implant. 3. When the nonsplinted restorations were not loaded, there were little stresses on the supporting structure of implants, but low level stresses were shown in the splinted restorations even after sectioning and soldering. 4. With splinted restorations, there were little differences in stresses between different crown lengths. When splinted restorations were loaded, stresses were increased slightly on the loaded implant, but relatively even stress distribution occurred among the three implants. Conclusions: Splinting the crowns of adjacent implants is recommended for Endopore implants under the overloading situation.

외과적 정출술을 이용한 치관-치근 파절된 미성숙 영구치의 치험례 (SURGICAL EXTRUSION OF THE CROWN-ROOT FRACTURED INCISORS: CASE REPORTS)

  • 이은미;김태완;김현정;김영진;남순현
    • 대한소아치과학회지
    • /
    • 제35권2호
    • /
    • pp.305-312
    • /
    • 2008
  • 치아의 치관-치근 파절은 치아파절이 치관과 치근에 걸쳐 발생되어 법랑질, 상아질 및 백악질까지 이환된 경우로 정의되며, 치수이환여부에 따라 복잡파절과 비복잡파절로 분류될 수 있다. 치관-치근 파절의 빈도는 유치열에서 2%, 영구치열에서 5%로 나타나며, 보통 상악 전치부에 호발한다. 이러한 치관-치근 파절된 치아의 수복을 위해서는 생물학적 폭경이 유지되어야 한다. 이를 위하여 사용되는 방법은 골삭제 후 치은절제술, 교정적 견인, 외과적 정출 후 수복하는 방법과, 인위적으로 발치하여 근관치료와 수복 후 재식하는 방법 등이 있다. 이중 외과적 정출술은 치아를 발거하여 파절부를 치은 연상으로 이동시켜 재식하는 방법으로서, 이는 치관부 파절편이 임상치근의 1/2 미만인 경우에 적응증이 될 수 있으며, 발견하지 못한 다른 파절편을 직접 시진할 수 있고 때로는 파절선을 순측에 위치시켜 치료시 시야확보 및 접근이 용이하다는 등의 장점이 있다. 본 증례에서는 외상으로 치관-치근 파절된 미완성 치근단의 상악 중절치를 가진 환아에서 외과적 정출술 후 근관치료와 광중합복합레진을 이용한 치관수복을 시행하였으며, 정기적 검진시 양호한 결과가 관찰됨을 확인할 수 있었다.

  • PDF

외과적 정출술을 통한 치은 하방 치경부 파절선이 있는 상악 전치부의 심미 보철 치료 (Esthetic restoration of subgingival crown-root fractured maxillary anterior tooth using surgical extrusion)

  • 이소진;김유진;박영범;조규성;정문규
    • 대한치과보철학회지
    • /
    • 제50권3호
    • /
    • pp.204-209
    • /
    • 2012
  • 치은연 하방에 치아 우식증이나 치아 파절이 발생했을 때, 치아를 탈구시켜 즉시 정출시키는 외과적 정출술을 이용한 치관 연장술은 자연치를 보존하고 추가적인 치주적 수술 없이 단기간에 심미적인 보철 치료를 가능하게 한다. 본 환자는 16세 남환으로 본원 보존과로부터 상악 좌측 중절치의 심미 수복을 위해 본원 보철과로 의뢰되었다. 상악 좌측 중절치는 근관치료가 되어 있었으며 치관-치근 파절로 인해 협측 치관 길이는 4mm였으며 구개측 판막을 열었을 때 근심 구개측 치경부 파절 범위는 치은 하방 3-4mm에 위치하였다. 외과적 정출술을 통한 치관연장술을 시행하였으며 경과 관찰 및 임시 치아의 단계를 거쳐 3개월 후에 전부 도재관으로 수복하여 만족할 만한 임상결과를 얻을 수 있었다.