• 제목/요약/키워드: Crown diameters

검색결과 39건 처리시간 0.027초

영구치 전치의 근원심경과 치관 길이에 관한 연구 (A Study on the Mesio-Distal Crown Diameters and Crown Length of the Permanent Anterior Teeth)

  • 이태정
    • 대한치과기공학회지
    • /
    • 제13권1호
    • /
    • pp.21-26
    • /
    • 1991
  • The mesiodistal crown diameters and crown length of the permanent anterior teeth have been studied and analyzed about the mean size, S.D, S.E etcs from stone models of 100 Korean male and 74 female. From the study, the following conclusions were made : 1. Statistical differences of left and right teeth were not found in the mesio distal crown diameters and crown length of the permanent anterior teeth. 2. The mean values of mesiodistal crown diameters of permanent anterior teeth were slightly larger in male than in females and statistical differences of males and females were found in maxillary right central incisor, mandibular left canine, mandibular right lateral incisor and mandibular right canine. 3. The mean values of crown length of permanent anterior teeth were slightly larger in male than in female and statistical differences of males and females were found in mandibular left canine, mandibular right canine. 4. Mesiodistal crown diameters and crown length of maxillary left lateral incisors and right lateral incisors of female are larger than that of male.

  • PDF

유치와 후속 영구치 근원심 폭경의 상관관계에 관한 연구 (A STUDY ON THE CORRELATIONS BETWEEN MESIODISTAL CROWN DIAMETERS OF THE DECIDUOUS AND SUCCESSIONAL PERMANENT TEETH)

  • 이두희;정규림;이기수
    • 대한치과교정학회지
    • /
    • 제15권2호
    • /
    • pp.341-352
    • /
    • 1985
  • The primary objective of this study is to estimate of the mesiodistal crown diameters of the unerupted permanent successors derived from the mesiodistal crown diameters of the deciduous teeth in Korean population. The subjects were 54 individuals (twenty nine boys and twenty five girls) with normal occlusion aged 6 to 13 years. The mesiodistal crown diameters of the deciduous and the successional permanent teeth were measured from the longitudinal dental cast models using the sliding calipers (Mitutoyo Co.). From the study, the results are as follows; 1. Sex differences of mesiodistal won diameters were less in the deciduous teeth, but male were more than that of female in the successional permanent teeth. 2. The mesiodistal crown diameters of the deciduous central incisors, lateral incisors, canines were smaller than that of the successional permanent teeth and the deciduous 1st molars, and 2nd molars were more larger than that of the successional permanent teeth. 3. Size differences between sum of the mesiodistal crown diameters of central incisors and lateral incisors in the decidous teeth and the successional permanent teeth were $7.20{\pm}1.79mm$ in upper, $5.38{\pm}1.64mm$ in lower and that of canine,1st molar and 2nd molar in the deciduous teeth and the successional permanent teeth were $0.56{\pm}1.19mm$ in upper, $2.22{\pm}1.19mm$ in lower. 4. In male, the correlation coefficients between the upper deciduous central incisor and the successional permanent tooth (r = 0.57) and in female, the correlation coefficients between the upper deciduous 1st molar and the successional permanent tooth (r=0.67) appeared the highest. 5. The regression constants were determined to estimate the mesiodistal crown diameters of the unerupted successional permanent teeth.

  • PDF

유치의 치아크기에 관한 연구 (A STUDY ON THE SIZE OF THE DECIDUOUS TEETH)

  • 백병주;전소희;김재곤;김영신
    • 대한소아치과학회지
    • /
    • 제29권3호
    • /
    • pp.382-388
    • /
    • 2002
  • 전라북도 전주시 유치원 어린이 650명을 대상으로 구강내 검사 실시하여 평균 연령 4.5세 어린이 100명(남아 50명, 여아 50명)의 유치열 석고모형을 계측하여 다음과 같은 결과를 얻었다. 1. 유치의 계측자내 오차는 제1유구치에서 다소 크고, 총평균치는 0.255mm이었다. 2. 유치의 근원심 및 순(협)설측 치관 직경은 전체 유치에서 남아가 여아보다 컸다. 3. 변동계수(coefficient variation)는 남 여아 모두 유전치부위가 유구치부위에 비해 다소 큰 경향을 보였고, 근원심 및 순(협)설측 치관 직경 모두 제2유구치에서 크기변화가 가장 적게 나타났다. 4. 좌, 우측 동명치 사이의 차이를 나타내는 비대칭성에서는 상악 근원심 크기 측정을 제외하고는 근원심 및 협설측 치관 크기 측정 모두에서 제2유구치가 제1유구치보다 보다 덜 비대칭적이었다. 5. Crown index는 상악의 경우 여아보다 남아에서 큰 반면, 하악의 경우에는 유견치를 제외하고는 여아에서 컸다. Crown module은 여아보다 남아에서 컸고, 일반적인 치아크기가 유중절치에서부터 제2유구치까지 점차 증가하였다. Crown area도 여아보다 남아에서 컸으며 하악 유중절치가 가장 적은 면적을 나타냈고, 상악 제2유구치가 가장 큰 면적을 나타냈다.

  • PDF

유구치 치관 및 기성금속관의 크기에 관한 계측학적 연구 (A MORPHOMETRIC STUDY ON THE PRIMARY MOLARS AND PREFORMED STAINLESS STEEL CROWN)

  • 최지은;정태성;김신
    • 대한소아치과학회지
    • /
    • 제28권3호
    • /
    • pp.355-362
    • /
    • 2001
  • 치아의 크기는 유전적으로나 비교해부학적, 치과 임상적인 면에서도 중요하다. 치아의 크기는 주로 복합적인 유전에 의해 결정되며, 다른 인종간에 차이가 나므로 인류학적 조사를 하는 데에도 사용된다. 특히 유치의 크기는 치과 임상적인 면에서 중요한데, 교합의 변화와 공간분석에 큰 역할을 한다. 소아치과 임상에서 사용하는 유구치의 수복에 주로 사용되는 금속관은 대부분 기성 제품이므로 수복시에는 치아 크기에 맞추어 선택해 사용한다. 유치 치관 크기는 인종에 따른 차이가 많은데 현재 임상에서 사용중인 기성금속관은 한국인 기준으로 만들어진 것이 아니므로, 기성 제품을 사용하기 위해서는 한국 아동 유치의 형태학적 특성을 정립하는 것이 우선되어야 한다. 한국 아동의 유구치의 인종적 특성과 좌우 비교, 성별을 비교하고, 소아치과 임상에서 많이 사용하는 기성 금속관의 크기와의 비교를 위한 기초자료를 얻기 위하여 부산 경남지역 아동 235명의 경석고 모형을 채득하여 유구치의 근원심경과 협설경을 digital calipers로 측정하였다. 또 시판중인 2종의 기성금속관의 근원심경과 협설경을 측정하여, 모형에서 계측한 유구치의 측정치와 비교하여 다음과 같은 결과를 얻었다. 1. 유구치 치관의 크기에 있어서 좌우 차이는 인정되지 않았으나, 모든 유구치에서 남아의 경우가 여아보다 큰 것으로 나타났다(P<0.05). 2. 회귀분석을 통한 비교결과 상, 하 제1유구치와 그 기성금속관간에는 다른 유구치에 비해 상대적으로 큰 차이를 보였다.

  • PDF

A morphometric study on stainless steel crowns of the primary first molar using a three dimensional scanner

  • Lee, Jihyun;Shin, Teo Jeon;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Hyun, Hong-Keun
    • 대한치과의사협회지
    • /
    • 제54권6호
    • /
    • pp.414-428
    • /
    • 2016
  • Objectives: The aim of this study was to assess the morphologic characteristics of two types of stainless steel crowns (SSCs) for the first primary molar using a 3D scanner. Study design: Two types of SSCs, KIDS CROWN (KC) and 3M ESPE ND-96 (ND), for the first primary molars were scanned using a 3D scanner. The mesiodistal and buccolingual diameters at the height of the contour and the cervical margin, occlusocervical diameters on the mesial, distal, buccal, and lingual aspects were measured, and the crown shape ratio, the smooth surface crown height ratio, and the cervical convergence were calculated. Results: In the crown shape ratio of the mandibular SSC, KC was larger buccolingually compared with ND. In the smooth surface crown height ratio, ND was larger than KC in all of the maxilla and mesial, distal, and lingual aspects of the mandible. ND was more convergent to the cervical mesiodistally and buccolingually compared with KC. Conclusion: In the superimposed images of the maxillary SSC, the mesiolingual and distolingual line angles of KC were more prominent compared with ND. In the mandible, ND demonstrated higher cusps and more obvious buccal developmental lobes than KC. ND showed a larger cervical undercut than KC.

  • PDF

유한요소법을 이용한 치과 임플란트 고정체의 직경과 길이에 따른 지지골의 응력 분석 (Finite element analysis on the stress of supporting bone by diameters and lengths of dental implant fixture)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.151-156
    • /
    • 2016
  • Purpose: The dental implant should be enough to endure chewing load and it's required to have efficient design and use of implant to disperse the stress into bones properly. This study was to evaluate the stress distribution on a supporting bone by lengths and diameters of the implant fixture. Methods: The modeling and analysis of stress distribution was used for the simple molar porcelain crown model by Solidworks as FEM program. It was designed on applying with tightening torque of 20 Ncm of a abutment screw between a cement retained crown abutment and a fixture. The fixtures of experimental model used 10, 13mm by length and 4, 5mm by diameter. A external vertical loading on the two buccal cusps of crown and performed finite element analysis by 100 N. Results: The maximum von Mises stress(VMS) of all supporting bone models by fixture length and diameter were concentrated on the upper side of supporting compact bone. The maximum stress of each model under vertical load were 164.9 MPa of M410 model, and 141.2 MPa of M413 model, 54.3 MPa of M510 model, 53.6 MPa of M513 model. Conclusion: The stress reduction was increase of fixture's diameter than it's length. So it's effective to use the wider fixture as possible to the conditions of supporting bone.

영구치 근원심 폭경의 상관관계에 관한 연구 (Correlations Between Mesiodistal Crown Diameters of Permanent Teeth)

  • 구중회;이기수
    • 대한치과교정학회지
    • /
    • 제11권2호
    • /
    • pp.143-150
    • /
    • 1981
  • Casts of 180 Korean male and female with normal occulsion of early permanent dentition (from dental age of Hellman III C, to IV A) were studied to measure the mesiodistal crown diameters and to calculate the coefficients of correlation between the teeth. From the study, the following conclusions were made: 1. Mesiodistal dimension of maxillary central incisors, canines, first molars and mandibular canines, first premolars, second premolars and first molars of male are larger than that of female. 2. Korean teeth are roughly intermediate between those of American Caucasian and those of American Negro. 3. In both sexes, the relation between the first and second premolars appeared highly correlated not only in the maxillary arch but also in the mandibular arch, and the relation between the central incisor and lateral incisor appeared highly correlated in the mandibular arch. 4. The relation between the maxillary and mandibular first premolars appeared highly correlated in both sex, and the relation between the maxillary canine and mandibular canine in male as well as between the maxillary central incisor and mandibular central incisor in female appeared highly correlated.

  • PDF

경북 봉화 지역 소나무림에 대한 수관연료 특성과 연료량 추정 (Crown Fuel Characteristics and Fuel Load Estimation of Pinus densiflora S. et Z. in Bonghwa, Gyeongbuk)

  • 장미나;이병두;서연옥;김성용;이영진
    • 한국산림과학회지
    • /
    • 제100권3호
    • /
    • pp.402-407
    • /
    • 2011
  • 본 연구의 목적은 경북 봉화 지역에 분포하는 소나무림을 대상으로 수관의 수직적 구조, 수관연료밀도, 수관특성을 분석하고, 수관연료량 추정을 위한 회귀모형을 개발하는 것이다. 소나무림에 대한 수관의 수직적 구조에서 연료량 비율은 수관의 중간부분이 가장 높은 것으로 나타났으며, 수관연료량에서 잎과 가지가 차지하는 비율은 잎 25%, 직경 1 cm이하 가지 33%로 수관화 확산 시 이용 가능한 수관연료량은 총 58%를 차지하는 것으로 나타났다. 봉화 지역 소나무림에 대한 평균 수관연료밀도는 $0.45kg/m^3$으로 매우 높게 나타났고, 잎과 1 cm이하의 이용 가능한 연료밀도는 $0.27kg/m^3$으로 나타났다. 선형회귀식과 비선형회귀식을 이용하여 이용 가능한 수관연료량과 전체 수관연료량을 추정한 결과, 선형회귀식의 경우 결정계수($R^2$)가 각각 84%, 88%로 나타난 반면에, 비선형회귀식의 경우 결정계수가 각각 90%, 95%로 더 높게 나타났다. 본 연구에서 제시된 상대생장식은 봉화 지역 소나무림의 산불관리와 수관화모델에 대한 정량적인 연료량 정보를 제공해 줄 수 있다.

유치용 수종 기성금속관의 형태에 대한 계측학적 연구 (A MORPHOMETRIC STUDY ON THE PREFORMED STAINLESS STEEL CRORWNS OF SOME BRANDS)

  • 한은옥;이지현;김신;정태성
    • 대한소아치과학회지
    • /
    • 제39권2호
    • /
    • pp.145-152
    • /
    • 2012
  • 소아치과 임상의는 유구치의 수복 치료에 있어 기성 금속관을 사용할 때, 실제 치아의 크기와 형태가 유사한 기성 금속관을 사용하는 것이 중요하다. 유치 치관의 크기와 형태는 인종에 따라 많은 차이를 보이며, 현재 많이 사용되고 있는 기성금속관은 외국 아동의 기준에 맞춰 제작된 제품으로 한국 아동의 유구치에 적용 시 실제 치아와 차이가 있을 것으로 생각된다. 하지만 최근에는 국산 제품의 기성금속관이 개발되었으며, 이는 한국 아동 유치의 형태학적 특징을 반영하였을 것으로 기대되고 있다. 본 연구에서는 부산, 경남 지역 아동 263명의 상, 하 제 1, 2 유구치 각각의 근원심경, 협설경을 측정한 자료를 바탕으로 한국 아동의 유구치 치관 크기에 대한 계측치를 현재 사용되고 있는 3종의 기성금속관(3M ESPE Stainless Steel Primary Molar Crown, Kids Crown, Sankin Anatom Primary Crown)과 회귀분석을 통해 비교 연구하여 다음과 같은 결과를 얻었다. 1. 세가지 기성금속관 모두에서 근원심경에 대한 협설경의 비율이 실제 치아보다 더 컸다. 2. 근원심경에 대한 협설경의 비율에 있어 3M ESPE Stainless Steel Primary Molar Crown과 Kids Crown은 대체로 비슷했으며, Sankin Anatom Primary Crown은 앞의 두 기성금속관과 차이가 났다. 그리고 이러한 차이는 하악 유구치에서 더욱 두드러졌다. 3. 실제 치아의 근원심경이 평균값과 가까울수록 기성금속관과의 적합도는 더 높으며, 반대로 평균값에서 멀어질수록 적합도는 낮아진다. 4. 실제 치아와 기성금속관 간에 가장 차이가 많이 나는 치아는 하악 제1유구치, 상악 제1유구치이다.

단일치 임플랜트 지지 보철물에서 고정체와 지대주 나사 직경의 차이에 따른 삼차원 유한요소법적 응력 분석 (THREE-DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF SINGLE IMPLANT RESTORATION USING DIFFERENT FIXTURE AND ABUTMENT SCREW DIAMETERS)

  • 권주홍;최민호;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.105-119
    • /
    • 2005
  • Statement of problem. As the effects of the various diameters of fixture and abutment screw on stress distribution was not yet examined, this study focused on the different design of single implant restoration using three dimensional finite element analysis. Purpose. This study was to compare five different fixture-abutment combinations for single implant supported restorations with different fixture and abutment screw diameters. Material of methods. The five kinds of finite element models were designed by 3 diameter fixtures ($\oslash$3.3, 3.75, 5.0 mm) with 3 different abutment screws $\oslash$1.5, 1.7, 2.0 mm). The crown for mandibular first molar was made using UCLA abutment according to Wheeler's anatomy. 244 N was applied at the central fossa with two different loading directions, vertically and obliquely (30$^{\circ}$) and at the buccal cusp vertically. Maximum von Mises stresses were recorded and compared in the supporting bone, crowns, fixtures, and abutment screws. Results. 1. The stresses in supporting bone and implant-abutment structure under oblique loading were greater than those under vertical or offset loading. The stresses under vertical loading were the least among 3 loading conditions regardless of the implant and abutment screw diameters. 2. The stresses in the narrow implants were greater than the wider implants. The narrow implant with narrow abutment screw showed highest stresses in the lingual crest, but the narrow implant with standard abutment screw showed highest stress in abutment screw. 3. The stresses of abutment screws were influenced by the diameter of fixtures and loading conditions. The wide implants showed least difference between two different abutment screw diameters. Conclusions. The wide implants showed lesser stresses than the narrow implants and affected least by the different abutment screw diameters. The narrow implants with standard abutment screw showed highest stresses in the lingual bony crest under oblique loading.