• Title/Summary/Keyword: Crown diameter

Search Result 281, Processing Time 0.029 seconds

Effect of Weight of Crown Part on Growth and Bolting Response in Ostericum koreanum Kitagawa. (노두무게에 따른 북강활의 생육 및 추대반응)

  • Kim, Soo-Yong;Lee, Sang-Seok;Choi, Hyo-Sim;Sohn, Hyoung-Rac;Oh, Sei-Myoung
    • Korean Journal of Medicinal Crop Science
    • /
    • v.17 no.3
    • /
    • pp.161-164
    • /
    • 2009
  • This study was conducted to investigate the weight of crown part effect on growth and bolting response of Ostericum koreanum Kitagawa. Bolting rate with crown part weight was represented 0%, 0%, 4.1%, 12.9%, 25.1%, 34.9% corresponding to each crown part weight 5 g, 10 g, 20 g, 30 g, 40 g, 50 g. The heavier the crown part weight was the higher the direction rate rose and the flowering time came earlier. The dried root amount was the highest at 30 g and crown part number, the length of root, and crown diameter showed all the highest figures at 30 g. The relation between amount per 10 g and outcrop weight increased on secondary regression formula as weight increased and reached its peak at 29.7 g and then decreased over 29.7 g.

Assessment of Wear Resistance in Tooth-Colored Materials for Primary Molar Crown Restoration in Pediatric Dentistry

  • Hyun Seok Kang;Yooseok Shin;Chung-Min Kang;Je Seon Song
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.51 no.1
    • /
    • pp.22-31
    • /
    • 2024
  • The objective of this study was to assess the wear resistance of tooth-colored materials used in crown restoration for primary molars with a chewing simulator. In this study, four groups-three experimental groups and one control group-were included. They consisted of three-dimensional (3D) printed resin crowns (NextDent and Graphy), milled nano-hybrid ceramic crowns (MAZIC Duro), and prefabricated zirconia crowns (NuSmile). Twelve mandibular second molar specimens were prepared from each group. In the wear experiment, 6.0 × 105 cycles were conducted with a force of 50 N, and a 6 mm-diameter steatite ball was used as an antagonist. The amount of wear was calculated by comparing the scan files before and after the chewing simulation using 3D metrology software, and the worn cross-section was confirmed by scanning electron microscopy (SEM). The resin and ceramic groups did not exhibit any statistically significant differences. However, compared to other crown groups, the zirconia crown group demonstrated notably reduced levels of wear (p < 0.05). In SEM images, layers and cracks were observed in the 3D-printed resin crown groups, which differed from those in the other groups.

Influence of size-anatomy of the maxillary central incisor on the biomechanical performance of post-and-core restoration with different ferrule heights

  • Domingo Santos Pantaleon;Joao Paulo Mendes Tribst;Franklin Garcia-Godoy
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.2
    • /
    • pp.77-90
    • /
    • 2024
  • PURPOSE. The study aims to investigate the influence of the ferrule effect and types of posts on the stress distribution in three morphological types of the maxillary central incisor. MATERIALS AND METHODS. Nine models were created for 3 maxillary central incisor morphology types: "Fat" type - crown 12.5 mm, root 13 mm, and buccolingual cervical diameter 7.5 mm, "Medium" type - crown 11 mm, root 14 mm, and buccolingual cervical diameter 6.5 mm, and "Slim" type - crown 9.5 mm, root 15 mm, and buccolingual cervical diameter 5.5 mm. Each model received an anatomical castable post-and-core or glass-fiber post with resin composite core and three ferrule heights (nonexistent, 1 mm, and 2 mm). Then, a load of 14 N was applied at the cingulum with a 45° slope to the long axis of the tooth. The Maximum Principal Stress and the Minimum Principal Stress were calculated in the root dentin, crown, and core. RESULTS. Higher tensile and compression stress values were observed in root dentin using the metallic post compared to the fiber post, being higher in the slim type maxillary central incisor than in the medium and fat types. Concerning the three anatomical types of maxillary central incisors, the slim type without ferrule height in mm presented the highest tensile stress in the dentin, for both types of metal and fiber posts. CONCLUSION. Post system and tooth morphology were able to modify the biomechanical response of restored endodontically-treated incisors, showing the importance of personalized dental treatment for each case.

Spot Heating Technology Development for Strawberry Cultivated in a Greenhouse by Using Hot Water Pipe (온수배관을 이용한 시설딸기 부분난방기술 개발)

  • Moon, Jongpil;Kang, Geum-Choon;Kwon, Jin-Kyung;Paek, Yee;Lee, Tae Seok;Oh, Sung-Sik;Nam, Myeong-Hyeon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.5
    • /
    • pp.71-79
    • /
    • 2016
  • The effects of spot heating for growing the strawberry cultivated in a plastic greenhouse during the winter that were estimated in Nonsan strawberry experiment station located in Chungnam. The temperature of water for heating was controlled by a electric hot water boiler and kept at the range of $22{\sim}24^{\circ}C$. Heating pipes were set up in root zone for root zone heating and very close to crown for crown heating. Spot heating effects were estimated by applying spot heating system in three test factors of heating root zone, crown only and crown plus root zone. The material for crown heating pipe was white low density polyethylene and the nominal diameter of that pipe was 16 mm. The material for root zone heating pipe was flexible stainless steel and the nominal diameter of that pipe was 15A. The flow rate of heating water circulation was 480 L/h and water circulation lasted for all day long. Temperatures, harvest yield by test beds were surveyed from Nov. 10, 2013 to Apr. 29, 2014. The temperature of crown spot for crown heating bed was at the range of $13.0{\sim}17.0^{\circ}C$ during the night and that of crown spot in control bed was at the range of $8.0{\sim}14.0^{\circ}C$. Also, the temperature of root zone for root zone heating bed was at the range of $18{\sim}21.0^{\circ}C$ and that of root zone in control bed was at the range of $13.0{\sim}15.0^{\circ}C$. The cumulative yield growth rate in earlier harvest period (from Dec. 20 to Mar. 15) of crown heating bed was 43% compared with that of control bed and the cumulative yield of crown plus root zone heating bed was 39 % and that of root zone heating bed was 39 %.

Three Dimensional Analysis of Primary Maxillary Central and Lateral Anterior Zirconia Crown (상악 유절치 지르코니아 전장관 수복을 위한 3차원 분석)

  • Lee, Jungmin;Lee, Hyoseol;Nam, Okhyung;Kim, Misun;Choi, Sungchul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.2
    • /
    • pp.176-186
    • /
    • 2016
  • This study was performed to compare the shape and dimension of anterior zirconia crowns to other pediatric crowns using a three-dimensional scanner to investigate adequate amount of tooth preparation. Primary central and lateral anterior zirconia crowns, stainless steel crowns and celluloid strip crowns were scanned by a three-dimensional scanner. Outer and inner surfaces of zirconia and stainless steel crowns, and outer surface of celluloid strip crowns were analyzed. In outer scanned images, all sizes of central and lateral size 1 zirconia crown had the largest labiolingual diameter among the three crowns. In inner scanned images, zirconia crown's mesiodistal diameter was 0.7-1.0 mm smaller and crown length was approximately 1 mm shorter than those of stainless steel crowns. Zirconia crown's labiolingual diameter was larger in central crowns whereas it was smaller in lateral crowns than that of stainless steel crowns. Recommended preparation required for zirconia crown is incisal 2.5-3.0 mm, mesiodistal 1.5-2.0 mm, labial 0.5-1.0 mm. Cingulum should be trimmed parallel to the long axis. No more lingual reduction is needed in central incisors whereas additional 0.5 mm reduction is suggested in lateral incisors.

Crown Fuel Characteristics and Allometric Equations of Pinus densiflora Stands in Youngju Region (영주지역 소나무림의 수관연료특성 및 수관연료량 추정)

  • Kim, Sungyong;Lee, Byungdoo;Seo, Yeonok;Lee, Youngjin
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.2
    • /
    • pp.266-272
    • /
    • 2011
  • This study was conducted to analyze the characteristics of crown fuel biomass and to develop allometric equations for the estimation of crown fuel biomass by subjectively categorized the crown component in Pinus densiflora stands. A total of ten representative trees were destructively sampled in Youngju region. Crown fuel were weighed separately for each fuel category by size class. The results of this study showed that foliar moisture content was 119% while the average crown moisture content was 105.3%. The crown fuel/total fuel loading ratio was 30%, needles and twigs with less than 1 cm diameter accounted 50.3% for its fuel/crown fuel loading ratio. Adjusted multiple coefficient of determination of suggested allometric equations ranged from 0.6846 to 0.9246 for crown fuel biomass, 0.8308 for crown volume.

Relation between crown-length, tree-height, diameter Clear-bale length and the longest branch length in a Pinus densiflora stand (적송림(赤松林)에 있어서의 성장인자간(成長因子間)의 상관(相關))

  • Yim, Kyong Bin;Pack, Myong Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.5 no.1
    • /
    • pp.27-32
    • /
    • 1966
  • Taking an opportunity of the application of clearcutting method, 140 red pine (Pinus densiflora Sieb. et Zucc.) trees grown at Chon-nam province, the southern part of South Korea, were fellen and the tree height, clear-bole length, D.B.H. diameter at base(0.2m above from the ground line) and the length of the longest branch were measured. The correlation between factors mentioned were analysed. The results are summarized as follows: 1. The correlation between crown length and tree height (r=0.821) was sinificant. 2. The correlation between the diameter at base and D.B.H. was highly significant (r=0.961). D.B.H. can be calculated from multiplying the diameter at base by 0.88. 3. A weak relation between D.B.H and tree height was abserved. 4. The positive correlation between tree height and clear-bole-length was calculated, but it was not sharp between D.B.H. and the length of the longest branch. 5. The height, basal area, D.B.H. and volume increment by tree class calculated from the data of the stem analysis are presented (Tab. 3~10).

  • PDF

Modeling Knot Properties for Mongolian Pine in Northeast China

  • Jia, Weiwei;Li, Fengri;Jiang, Lichun
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.5
    • /
    • pp.485-491
    • /
    • 2008
  • This study was performed in 14 unthinned Mongolian pine (Pinus sylvestris L. var. mongolica Litvin) plantations in northeast China. Data were collected on 70 sample trees of different canopy position with diameter at breast height (DBH) ranging from 6.9 cm to 34.5 cm. Diameter and length of knots per whorl below the living crown were studied by different vertical levels divided by relative knot height (RHK) in this paper. Models taking DBH and height to the crown base (HCB) as independent variables were developed to predict knot diameter (KD) in a sample whorl. According to the vertical distribution tendency and range of sound knot length (KLsound), KLsound was modeled as multiple linear function of DBH, KD and relative knot height (RHK). The loose knot length (KLloose) was described as a function of DBH, KD and height above the ground for knots (HK) in a mixed log-linear model. Results from this study can provide abundant knot information so as to describe the knot size and vertical distribution tendency of Mongolian pine plantation.

Critical evaluation of fracture strength testing for endodontically treated teeth: a finite element analysis study

  • Uzunoglu-Ozyurek, Emel;Eren, Selen Kucukkaya;Eraslan, Oguz;Belli, Sema
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.2
    • /
    • pp.15.1-15.8
    • /
    • 2019
  • Objectives: The aim of this study was to investigate whether the diameter and direction of the plunger and simulation of the periodontal ligament (PDL) affected the stress distribution in endodontically treated premolars. Methods: A fracture strength test was simulated via finite element analysis. A base model was set up, and the following parameters were modified: plunger diameter (3 mm vs. 6 mm), plunger direction (vertical vs. $135^{\circ}$ angular to the central fossa), and PDL simulation. The analysis was conducted using the CosmosWorks structural analysis program, and the results are presented in terms of von Mises stresses. Results: The smaller plunger increased the stresses at the contact area of the crown, but the plunger diameter had no effect on the stress distribution within the root. An angular plunger direction increased stresses within the root, as well as at the buccal cusp of the crown, compared with the vertical direction. Simulation of the PDL caused higher stress accumulation, especially in the cervical region of the root. Conclusions: The plunger diameter had no effect on the stress distribution in the roots, whereas the plunger direction and PDL simulation did affect the stress distribution. More stringent standards can be established by taking such parameters into account when performing fracture testing in future studies.

SINGLE TOOTH IMPLANT RESTORATION USING COMBINATION IMPLANT CROWN : A CASE REPORT (콤비네이션 임프란트 크라운(Combination Implant Crown)을 이용한 단일치아의 임프란트 보철수복증례)

  • Kim, Rae-Gyoung;Song, Eon-Hee;Choi, Byeong-Gap;Kim, Hyoun-Chull;Ahn, Hyun-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.375-382
    • /
    • 1999
  • The purpose of this article is to present the clinical and laboratory procedures for single tooth restoration using 'Combination Implant Crown'. It is cemented on implant abutment and that abutment is screw-retained over implant body. This type of implant restorations has the advantages of cement-retained restoration while being antirotational and retrievable. And, more esthetic and functional result can be achieved by minimizing the size of access hole. The results were as follows : 1. Preparation of abutment below the cuff line should be avoided 2. Axial reduction of implant abutment should not be excessive because it may weaken the abutment 3. More esthetical and functional occlusal surface was achieved with a minimal access hole which is slightly larger than the diameter of hex driver to enable future total retrievability. 4. Combination Implant Crown has the advantages of both the cement-retained and screw-retained type implant restoration. 5. Cementation between implant crown and abutment reduces screw loosening through even force distribution

  • PDF