• Title/Summary/Keyword: Crown dental

Search Result 880, Processing Time 0.023 seconds

A comparison of the fidelity of various zirconia-based all-ceramic crowns fabricated with CAD/CAM systems (수종의 CAD/CAM 시스템으로 제작한 지르코니아 기반 완전도재관의 적합도 비교)

  • Kim, Sung-Jun;Jo, Kwang-Hun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.148-155
    • /
    • 2009
  • Statement of problem: The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems there is a need to evaluate the quality levels of these new fabrication techniques. Purpose: This study is to evaluate the crown fidelity(absolute marginal discrepancy and internal gap) of various zirconia-based all-ceramic crowns fabricated with different CAD/CAM(computer-assisted design/computer-assisted manufacturing) systems and conventional cast metal-ceramic crowns. Material and methods: A resin tooth of lower right second premolar was prepared. After an impression was taken, one metal master die was made. Then 40 impressions of metal master dies were taken for working dies. 10 crowns per each system were fabricated using 40 working dies. Metal-ceramic crowns were cast by using the conventional method, and Procera, Lava, and Cerec inLab crowns were fabricated with their own CAD/CAM manufactruing procedures. The vertical marginal discrepancies and internal gaps of each crown groups were measured on a metal master die without a luting agent. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test. Results: 1. Vertical marginal discrepancies were $50.6{\pm}13.9{\mu}m$ for metal-ceramic crowns, $62.3{\pm}15.7{\mu}m$ for Procera crowns, $45.3{\pm}7.9{\mu}m$ for Lava crowns, and $71.2{\pm}2.0{\mu}m$ for Cerec inLab crowns. 2. The Internal gaps were $52.6{\pm}10.1{\mu}m$ for metal-ceramic crowns, $161.7{\pm}18.5{\mu}m$ for Procera crowns, $63.0{\pm}10.2{\mu}m$ for Lava crowns, and $73.7{\pm}10.7{\mu}m$ for Cerec inLab crowns. Conclusion: 1. The vertical marginal discrepancies of, 4 crown groups were all within the clinically acceptable range($120{\mu}m$). 2. The internal gaps of LAVA, Cerec inlab, and metal-ceramic crowns were within clinically acceptable range except Procera crown($140{\mu}m$).

CASE OF DENTIGEROUS CYSTS TREATED BY MARSUPIALIZATION (조대술을 이용한 함치성 낭종의 치료)

  • Park, Sung-Jin;Lee, Kwang-Hee;Kim, Dae-Eop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.459-464
    • /
    • 2003
  • Dentigerous cyst is a cyst arising by tissue fluid accumulation between the enamel and the residual enamel epithelium. It includes the crown of the impacted tooth and excludes the root. The treatments of the dentigerous cyst are enucleation, marsupialization, decompression, surgical excision and etc. In these cases children were evaluated for the chief complaints of the remained mandibular primary second molar. Each cases showed swelling on the buccal side of the primary secondary premolar. In the radiologic evaluation a radiolucent lesion including the crown of the mandibular secondary premolar was found, and it was diagnosed as dentigerous cyst. And the histopathologic examination showed the same result. Marsupialization was operated through alveolar socket and the alveolar socket was protected with vaseline gauze, the obturator combined with space maintainer was followed by the operation. After the operation, the impacted permanent tooth was showing faster eruption speed than the other normal teeth.

  • PDF

Evaluation of the accuracy of linear and angular measurements on panoramic radiographs taken at different positions

  • Nikneshan, Sima;Sharafi, Mohamad;Emadi, Naghmeh
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.191-196
    • /
    • 2013
  • Purpose: This study assessed the accuracy of linear and angular measurements on panoramic radiographs taken at different positions in vitro. Materials and Methods: Two acrylic models were fabricated from a cast with normal occlusion. Straight and $75^{\circ}$ mesially and lingually angulated pins were placed, and standardized panoramic radiographs were taken at standard position, at an $8^{\circ}$ downward tilt of the occlusal plane compared to the standard position, at an $8^{\circ}$ upward tilt of the anterior occlusal plane, and at a $10^{\circ}$ downward tilt of the right and left sides of the model. On the radiographs, the length of the pins above (crown) and below (root) the occlusal plane, total pin length, crown-to-root ratio, and angulation of pins relative to the occlusal plane were calculated. The data were subjected to repeated measures ANOVA and LSD multiple comparisons tests. Results: Significant differences were noted between the radiographic measurements and true values in different positions on both models with linear (P<0.001) and those with angulated pins (P<0.005). No statistically significant differences were observed between the angular measurements and baselines of the natural head posture at different positions for the linear and angulated pins. Conclusion: Angular measurements on panoramic radiographs were sufficiently accurate and changes in the position of the occlusal plane equal to or less than $10^{\circ}$ had no significant effect on them. Some variations could exist in the pin positioning (head positioning), and they were tolerable while taking panoramic radiographs. Linear measurements showed the least errors in the standard position and $8^{\circ}$ upward tilt of the anterior part of the occlusal plane compared to other positions.

COMPARISON OF RETENTIVE FORCES OF TEMPORARY CEMENTS AND ABUTMENT HEIGHT USED WITH IMPLANT-SUPPORTED PROSTHESES

  • Lee, Dong-Hee;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.280-289
    • /
    • 2008
  • STATEMENT OF THE PROBLEM: Recent data regarding the effects the cement type and abutment heights on the retentive force of a prosthetic crown are inconsistent and unable to suggest clinical guidelines. PURPOSE OF THE STUDY: This study evaluated the effects of different types of temporary cements and abutment heights on the retentive strength of cement-retained implant-supported prostheses. MATERIALS AND METHODS: Prefabricated implant abutments, 4 mm in diameter, $8^{\circ}$taper per side, and light chamfer margins, were used. The abutment heights of the implants were 4 mm, 5.5 mm and 7 mm. Seven specimens of a single crown similar to a first premolar were fabricated. Six commercially available temporary cements, TempBond, TempBond NE, Cavitec, Procem, Dycal, and IRM, were used in this study. Twenty-four hours after cementation, the retentive strengths were measured using a universal testing machine with a crosshead speed of 0.5 mm/min. The cementation procedures were repeated 3 times. The data was analyzed using two-way analysis of variance and a Tukey test (${\alpha}$=0.05). RESULTS: The tensile bond strength ranged from 1.76 kg to 19.98 kg. The lowest tensile strengths were similar in the TempBond and Cavitec agents. Dycal showed the highest tensile bond strength (P<0.01). More force was required to remove the crowns cemented to the long abutments (P<0.05). CONCLUSION: TempBond and Cavitec agents showed the lowest mean tensile bond strength. The Dycal agent showed more than double the tensile bond strength of the TempBond agent.

Prosthetic restoration of the maxillary anterior teeth using implantation and forced eruption: Case report (인위적 정출술과 임플란트 치료를 통한 상악 전치부 보철치료)

  • Kim, Kyoung-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.80-86
    • /
    • 2011
  • When a tooth adjacent to implant has coronal damages caused by severe dental caries or fracture, the clinical crown lengthening by forced eruption makes it possible to get esthetic restoration due to the prevention of alveolar crestal bone resorption and loss of interdental papilla. A 54-years-old male patient wanted prosthetic treatment because his anterior 3 unit bridges had fallen out. A right maxillary central incisor showed mild dental caries but a right maxillary canine lost most clinical crowns. Forced eruption combined with a gingival fiberotomy of a right maxillary canine was performed for 1 month after the dental implant had been simultaneously placed with bone grafts on a right maxillary lateral incisor. About 5 months after implant placement, 2nd surgical operation was performed. The provisional restorations were adjusted to make esthetic gingival contour for 8 weeks. The porcelain fused gold restorations were fabricated and set. The patient was satisfied with the final restorations in esthetic and functional aspect.

In vitro performance and fracture resistance of novel CAD/CAM ceramic molar crowns loaded on implants and human teeth

  • Preis, Verena;Hahnel, Sebastian;Behr, Michael;Rosentritt, Martin
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.300-307
    • /
    • 2018
  • PURPOSE. To investigate the fatigue and fracture resistance of computer-aided design and computer-aided manufacturing (CAD/CAM) ceramic molar crowns on dental implants and human teeth. MATERIALS AND METHODS. Molar crowns (n=48; n=8/group) were fabricated of a lithium-disilicate-strengthened lithium aluminosilicate glass ceramic (N). Surfaces were polished (P) or glazed (G). Crowns were tested on human teeth (T) and implant-abutment analogues (I) simulating a chairside (C, crown bonded to abutment) or labside (L, screw channel) procedure for implant groups. Polished/glazed lithium disilicate (E) crowns (n=16) served as reference. Combined thermal cycling and mechanical loading (TC: $3000{\times}5^{\circ}C/3000{\times}55^{\circ}C$; ML: $1.2{\time}10^6$ cycles, 50 N) with antagonistic human molars (groups T) and steatite spheres (groups I) was performed under a chewing simulator. TCML crowns were then analyzed for failures (optical microscopy, SEM) and fracture force was determined. Data were statistically analyzed (Kolmogorow-Smirnov, one-way-ANOVA, post-hoc Bonferroni, ${\alpha}=.05$). RESULTS. All crowns survived TCML and showed small traces of wear. In human teeth groups, fracture forces of N crowns varied between $1214{\pm}293N$ (NPT) and $1324{\pm}498N$ (NGT), differing significantly ($P{\leq}.003$) from the polished reference EPT ($2044{\pm}302N$). Fracture forces in implant groups varied between $934{\pm}154N$ (NGI_L) and $1782{\pm}153N$ (NPI_C), providing higher values for the respective chairside crowns. Differences between polishing and glazing were not significant ($P{\geq}.066$) between crowns of identical materials and abutment support. CONCLUSION. Fracture resistance was influenced by the ceramic material, and partly by the tooth or implant situation and the clinical procedure (chairside/labside). Type of surface finish (polishing/glazing) had no significant influence. Clinical survival of the new glass ceramic may be comparable to lithium disilicate.

STUDY OF THE EFFECT OF ULTRASONIC INSTRUMENTATION ON BOND STRENGTH OF SEVERAL DENIAL CEMENTS (초음파 기구가 수종의 치과용 시멘트의 결합강도에 미치는 영향에 관한 연구)

  • Kim, Won-Sang;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.3
    • /
    • pp.504-516
    • /
    • 1997
  • Ultrasonic instruments transfer electrical energy to mechanical energy resulting in vibration used for various dental treatments. If we could know the effect of ultrasonic instruments on the dental cements within the cast crown, we could take care when conducting periodontal surgery and when using the ultrasonic instrument to remove cast crown, it would be much more convenient. The purpose of this study was to compare the bond strength of several dental cements according to ultrasonic instrumentation time. In this study 4 types of cements were used to cement the specimens. they were treated with ultrasonic instrumentation for 0-5 minutes and the change in bond strength were statistically compared. The results were as followed. 1. The tensile bond strength of zinc phosphate cement decreased according to the increase in time of ultrasonic instrument and showed significant difference between 0 minutes and the others and between 1 minute and 2,3,4,5 minutes (p<0.05). 2. The tensile bond strength of polycarboxylate cement decreased according to the increase in time of ultrasonic instrument and showed significant difference between 5 minutes and the others and between 4 minutes and 0 minutes (p<0.05). 3. The tensile bond strength of zinc phosphate cement decreased according to the increase in time of ultrasonic instrument and showed significant difference between 5 minutes and the others (p<0.05). 4. The tensile strength of resin cements showed no statistically differences according to the ultrasonic instrumentation time. In conclusion, it is considered that zinc phosphate cements is most affected by ultrasonic instrumentations and resin cement is the least affected. When using ultrasonic instruments the result avove should be used as an index.

  • PDF

Effect of abutment neck taper and cement types on the amount of remnant cement in cement-retained implant restorations: an in vitro study

  • Park, Yeon-Hee;Kim, Kyoung-A;Lee, Jung-jin;Kwon, Tae-min;Seo, Jae-Min
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.3
    • /
    • pp.162-172
    • /
    • 2022
  • PURPOSE. The present study aims to analyze the effect of abutment neck taper and types of cement on the amount of undetected remnant cement of cement-retained implant prostheses. MATERIALS AND METHODS. Three neck taper angles (53°, 65°, 77°) and three types of cement (RMGI: resin-modified glass ionomer, ZPC: zinc phosphate cement, ZOE: zinc oxide eugenol cement) were used. For each group, the surface percentage was measured using digital image and graphic editing software. The weight of before and after removing remnant cement from the abutment-crown assembly was measured using an electronic scale. Two-way ANOVA and Duncan & Scheffe's test were used to compare the calculated surface percentage and weight of remnant cement (α = .05). RESULTS. There were significant differences in remnant cement surface percentage and weight according to neck taper angles (P < .05). However, there were no significant differences in remnant cement surface percentage and weight on types of cement. No interaction was found between neck taper angles and types of luting cement (P > .05). The wide abutment with a small neck taper angle showed the most significant amount of remnant cement. And the types of luting cement did not influence the amount of residual cement. CONCLUSION. To remove excess cement better, the emergence profile of the crown should be straight to the neck taper of the abutment in cement-retained implant restoration.

Novel design of implant prosthesis considering esthetics and periodontal maintenance: case report (심미성 및 치주 조직의 유지 관리를 고려한 임플란트 보철 증례)

  • Paek, Janghyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.70-76
    • /
    • 2014
  • After extraction of tooth, alveolar ridge resorption is inevitable in most cases. Clinicians confront with horizontal and vertical resorption of alveolar bone. Without massive amount of bone and soft tissue graft, dental implant will be placed apically to gain stability. In those cases, not only white esthetic part, but also pink esthetic part should be restored with pink porcelain. The margin of prosthesis should be located apically to reproduce natural look with adjacent teeth. However, when the margin is located apically, it is always hard to remove remaining cement, thus complications may arise. In this report, a novel design of implant prosthesis is introduced to solve those issues. The novel design is consisted of zirconia framework with pink porcelain and separate crowns on top of the framework. It eliminates the possibility of cement remnants by bringing the crown margin coronally. Pink esthetic part is incorporated in abutment part instead of crown part and the screw hole is covered with separate crowns.

ROENTGENOLOGIC INVESTIGATIONS FOR THE ANTERIOR TOOTH LENGTH (전치장경에 관한 X-선학적 연구)

  • Cho Won Pyo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.2 no.1
    • /
    • pp.53-57
    • /
    • 1972
  • The author measured the length of crown, root and tooth on the films which was taken by intraoral bisecting technic with mesh plate on the films. The films were taken from the dry skulls, dentiform and patients who had to be removed their upper incisors and the other patients who adimitted for dental care. From this serial experiment the results was made as follows: 1. By using the film and mesh plate in the oral cavity, the real tooth length can be measured easily on the film surfaces. 2. It can be avoided the film distortion in the oral cavity when taking the film using the mesh plate and film together. 3. When measuring the film, length of crown was elongated and length of root was shortened. 4. When using the well-trained bisecting technic, the real tooth length can be measured directly on the intraoral film.

  • PDF