• Title/Summary/Keyword: Crown dental

Search Result 880, Processing Time 0.026 seconds

Causes of failures of long-term used double crown denture and new rehabilitation with dental implant and tooth combined denture using remaining teeth and implants (장기간 사용한 이중관 의치의 실패원인 및 자연치와 임플란트를 이용한 이중관 의치 수복증례)

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.384-390
    • /
    • 2018
  • Hybrid telescopic double crown have ever been good treatment option for patient with periodontally unfavorable few remaining teeth for successful prognosis. Tooth and implant combined telescopic double crown can be used for improving retention and support for denture with strategically placed implants on edentulous ridge. In this case, an 55-year-old female patient had chronic periodontitis with few remaining teeth on maxilla and fixed partial prosthodontics on mandible. Treatment of hybrid telescopic double crown with friction pin lasted 9.5 years only with natural teeth. After 9.5 years, additional implants was installed due to fracture of cast-posted abutment teeth. After implantation, tooth and implant combined double crown had fabricated. Through re-treatment, no complications of new denture has been found during 2 years follow up. This case presents fair prognosis of tooth and implant combined double crown denture in periodontally unfavorable condition.

A STUDY ON THE CORRELATIONS BETWEEN MESIODISTAL CROWN DIAMETERS OF THE DECIDUOUS AND SUCCESSIONAL PERMANENT TEETH (유치와 후속 영구치 근원심 폭경의 상관관계에 관한 연구)

  • Lee, Doo-Hee;Chung, Kyu-Rhim;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.15 no.2
    • /
    • pp.341-352
    • /
    • 1985
  • The primary objective of this study is to estimate of the mesiodistal crown diameters of the unerupted permanent successors derived from the mesiodistal crown diameters of the deciduous teeth in Korean population. The subjects were 54 individuals (twenty nine boys and twenty five girls) with normal occlusion aged 6 to 13 years. The mesiodistal crown diameters of the deciduous and the successional permanent teeth were measured from the longitudinal dental cast models using the sliding calipers (Mitutoyo Co.). From the study, the results are as follows; 1. Sex differences of mesiodistal won diameters were less in the deciduous teeth, but male were more than that of female in the successional permanent teeth. 2. The mesiodistal crown diameters of the deciduous central incisors, lateral incisors, canines were smaller than that of the successional permanent teeth and the deciduous 1st molars, and 2nd molars were more larger than that of the successional permanent teeth. 3. Size differences between sum of the mesiodistal crown diameters of central incisors and lateral incisors in the decidous teeth and the successional permanent teeth were $7.20{\pm}1.79mm$ in upper, $5.38{\pm}1.64mm$ in lower and that of canine,1st molar and 2nd molar in the deciduous teeth and the successional permanent teeth were $0.56{\pm}1.19mm$ in upper, $2.22{\pm}1.19mm$ in lower. 4. In male, the correlation coefficients between the upper deciduous central incisor and the successional permanent tooth (r = 0.57) and in female, the correlation coefficients between the upper deciduous 1st molar and the successional permanent tooth (r=0.67) appeared the highest. 5. The regression constants were determined to estimate the mesiodistal crown diameters of the unerupted successional permanent teeth.

  • PDF

Stress Analysis of Abutment and Supporting Tissues by Changing Angles and Heights of Konus Telescope Inner Crown (Konus Telescopic Denture의 내관 각도 및 높이에 따른 지대치 및 지지조직의 응력 분석)

  • Vang, Mong-Sook;Gettleman, Lawrence
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.139-151
    • /
    • 2003
  • This study was to evaluate and to compare the compressive strength and the displacement effecting the abutment or the residual ridge which are transformed by the angle and the heights of the konus denture inner crown when restorating the unilateral konus denture by using the mandibular canine and the 1st premolar as an abutment. The author made 9 different models for different inner crown heights and konus angles. The inner crown height were divided to 5mm, 6mm, and 7mm and konus angles was divided to $4^{\circ}$, $6^{\circ}$, and $8^{\circ}$. And then in each model, 5kg of $15^{\circ}$ mesial load was stressed on the central fossa of the 1st premolar and the 1st molar. The stresses and displacement were measured using the finite element analysis. The results were as follows 1. The maximum compressive strength was shown on the connective area of the abutment and the denture base. 2. As the angle of the inner crown becomes increased, the compressive strength was shown smaller. 3. As the height of the inner crown becomes increased, the maximum compressive strength was shown smaller while the compressive strength of the root apex and the residual ridge showed larger. 4. When the stress was loaded only on the 1st premolar, the more compressive strength was concentrated on the root apex area of the 1st premolar. 5. When the stress was loaded only on the 1st premolar, the compressive strength was concentrated uniformly on the abutment and the residual ridge. 6. When the stress was loaded only on the 1st molar, the maximum displacement was shown on the distal part of the residual ridge.

A Study on Remake of Dental Prosthesis According to Dental Laboratory Characteristics (Focusing on Daegu and Gyeong-buk of Dental lab) (치과기공소의 특성에 따른 치과보철물의 재제작에 관한 연구 - 대구.경북 치과기공소 중심으로 -)

  • Kim, Jeong-Sook;Lee, Hee-Sung
    • Journal of Technologic Dentistry
    • /
    • v.33 no.3
    • /
    • pp.227-236
    • /
    • 2011
  • Purpose: The purpose of this study was to reduce the remake rate of dental prosthesis. We examined remake cause and major factor of dental prosthesis to determine methods for raising dental prosthesis satisfaction. Methods: Subjects included dental technicians in the metropolitan areas of the cities of Daegu and Gyeong-buk. Surveys were filled out by consenting dental technicians. Statistical analysis was done using SPSS version 19.0 for Windows. We determined frequencies and percentage, calculating means, and standard deviations, and determining statistical significance using t-tests, analysis of variance. Results: Impression or material transform is high among remake cause and margin is high among remake major factor. Crown class showed differences in General characteristics associated with age, number of employees, and number of connection dental. Porcelain class showed differences in General characteristics associated with age, number of employees, and number of connection dental. Denture class showed differences in General characteristics associated with age, monthly salaray, and career. Implant class showed differences in General characteristics associated with age, education, and career. Conclusion: In order to reduce remake rate of dental prosthesis, communication of dentist, dental technician, and the patient are require and correct information of patient and dental prosthesis are need.

A Feasibility Study for the Development of Dental Technology curriculum (Focusing on Daegu-Gyeongbuk Area) (치기공과 교육과정의 타당성에 관한 연구 - 대구.경북지역을 중심으로 -)

  • Kim, Jeong-Sook;Park, Kwang-Sig;Kim, Won-Gi
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.165-177
    • /
    • 2012
  • Purpose: The purpose of this study is to lay the groundwork for the development of appropriate training courses for a rapidly changing digital technology in the field of Dental technology. Methods: The subjects of this study were dental technicians, dental technology students, a professor of dental technology in Daegu and Gyeongbuk area and a self-administered structured questionnaire survey was conducted for 350 randomly selected people. Collected data were analyzed using SPSS Win 17.0 statistics program and analysis techniques include the frequency, percentage and cross-analysis. Results: The results of the survey are as follows. The usefulness of Major subjects was Full Denture laboratory (4.72 points), Dental Morphology (4.71 points), Crown and Bridge laboratory (4.69 points) in the instructor's group. The usefulness of Major subjects was Dental Morphology (4.56 points), Full Denture (4.36 points), Crown and Bridge laboratory (4.69 points) in the student's group. The usefulness of Major subjects was Dental Morphology (4.58 points), Dental Morphology laboratory (4.34 points), Partial Denture laboratory (4.30 points) in the dental technician's group. Subject with the highest usefulness of required course to open was CAD/CAM lecture and laboratory, the highest proportion of 91.2% and Implant laboratory was very useful (91.2%) in the instructor's group. Subject with the highest usefulness of required course to open was CAD/CAM lacture and laboratory, the highest proportion of 90.0% and Implant laboratory was very useful (91.2%) in the student's group. Subject with the highest usefulness of required course to open was CAD/CAM lacture and laboratory, the highest proportion of 91.2% and Implant laboratory was very useful (90.2%) in the dental technician's group. Conclusion: Semester of the subjects was required establishment of CAD/CAM lecture and laboratory in the third year first semester (85.1%) and Implant laboratory in the third year second semester the third year was the highest proportion of 94.1% in the instructor's group. 87.0% of students need to open CAD/CAM lacture and laboratory in the third year first semester, Implant laboratory in the third year second semester the third year was the highest proportion of 85.0% in the student's group. Semester of the subjects was required establishment of CAD/CAM lecture and laboratory in the third year first semester (81.0%) and Implant laboratory in the third year second semester the third year was the highest proportion of 80.0% in the dental technician's group.

Diagnostic imaging analysis of the impacted mesiodens (매복 정중치의 진단영상분석)

  • Noh, Jeong-Jun;Choi, Bo-Ram;Jeong, Hwan-Seok;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.40 no.2
    • /
    • pp.69-74
    • /
    • 2010
  • Purpose : The research was performed to predict the three dimensional relationship between the impacted mesiodens and the maxillary central incisors and the proximity with the anatomic structures by comparing their panoramic images with the CT images. Materials and Methods : Among the patients visiting Seoul National University Dental Hospital from April 2003 to July 2007, those with mesiodens were selected (154 mesiodens of 120 patients). The numbers, shapes, orientation and positional relationship of mesiodens with maxillary central incisors were investigated in the panoramic images. The proximity with the anatomical structures and complications were investigated in the CT images as well. Results : The sex ratio (M : F) was 2.28 : 1 and the mean number of mesiodens per one patient was 1.28. Conical shape was 84.4% and inverted orientation was 51.9%. There were more cases of anatomical structures encroachment, especially on the nasal floor and nasopalatine duct, when the mesiodens was not superimposed with the central incisor. There were, however, many cases of the nasopalatine duct encroachment when the mesiodens was superimpoised with the apical 1/3 of central incisor (52.6%). Delayed eruption (55.6%), crown rotation (66.7%) and crown resorption (100%) were observed when the mesiodens was superimposed with the crown of the central incisor. Conclusion : It is possible to predict three dimensional relationship between the impacted mesiodens and the maxillary central incisors in the panoramic images, but more details should be confirmed by the CT images when necessary.

Analysis of quality for fixed prostheses fabricated by dental CAD-CAM system (치과용 캐드캠 시스템으로 제작된 고정성 보철물의 품질 분석)

  • Kim, Won-Soo;Han, Man-So;Jung, Jae-Kwan;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.36 no.3
    • /
    • pp.159-164
    • /
    • 2014
  • Purpose: The purpose of this study was analysis of quality of fixed prostheses fabricated by dental CAD/CAM system. Methods: The ten same cases of stone models were manufactured by dental scannable model, and stone models were scanned using the dental scanner for changing digital model. Ten digital models were completed. The design of zirconia core for zirconia based all-ceramic crown was conducted by the dental CAD program. The samples were fabricated using the pre-sintered zirconia block by dental milling machine. Marginal gaps were analyzed using by silicone replica technique at the eight parts for quality analysis of samples. One-way ANOVA was used for statistical analysis(${\alpha}=0.05$). Results: The mean for marginal gaps were $93.2{\sim}99.1{\mu}m$ at the eight parts. One-was ANOVA didn't show significant differences(p=0.089). Conclusion: The fixed dental prostheses fabricated by dental CAD/CAM were within clinically acceptable range.

Alternate metal framework designs for the metal ceramic prosthesis to enhance the esthetics

  • Vernekar, Naina Vilas;Jagadish, Prithviraj Kallahalla;Diwakar, Dr Srinivasan;Nadgir, Ramesh;Krishnarao, Manjunatha Revankar
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.3
    • /
    • pp.113-118
    • /
    • 2011
  • PURPOSE. The objective of the present study was to evaluate the effect of five different metal framework designs on the fracture resistance of the metal-ceramic restorations. MATERIALS AND METHODS. For the purpose of this study, the central incisor tooth was prepared, and the metal analogue of it and a master die were fabricated. The counter die with the 0.5 mm clearance was used for fabricating the wax patterns for the metal copings. The metal copings with five different metal framework designs were designed from Group 1 to 5. Group 1 with the metal collar, Group 2, 3, 4 and 5 with 0 mm, 0.5 mm, 1 mm and 1.5 mm cervical metal reduction respectively were fabricated. Total of fifty metal ceramic crown samples were fabricated. The fracture resistance was evaluated with the Universal Testing Machine (Instron model No 1011, UK). The basic data was subjected to statistical analysis by ANOVA and Student's t-test. RESULTS. Results revealed that the fracture resistance ranged from 651.2 to 993.6 N/$m^2$. Group 1 showed the maximum and Group 5 showed the least value. CONCLUSION. The maximum load required to fracture the test specimens even in the groups without the metal collar was found to be exceeding the occlusal forces. Therefore, the metal frameworks with 0.5 mm and 1 mm short of the finish line are recommended for anterior metal ceramic restoration having adequate fracture resistance.

Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model

  • Jang, Yeon;Sim, Ji-Young;Park, Jong-Kyoung;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.367-373
    • /
    • 2018
  • PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the "Best-fit alignment" method using the analysis software. One-way and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (${\alpha}=.05$). Tukey's HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<$120{\mu}m$).

ESTHETIC RESTORATION OF ANTERIOR STAINLESS STEEL CROWN WITH COMPOSITE RESIN VENEER (Stainless steel crown 순면위에 레진피복을 이용한 전치부 심미적 수복)

  • Park, Jong-Ha;An, Soo-Hyeon;Kim, Jae-Gon;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.4
    • /
    • pp.805-812
    • /
    • 1997
  • Despite dentistry's attempts to improve the dental health of the public and to minimize the effects of caries, many children still present with extensive destruction of primary anterior teeth. One of dentistry's most challenging tasks is to repair these teeth with restoration which are durable, retentive, and esthetic. Esthetic restoration can often be achieved with polycarbonate crowns, strip crowns, conventional S-S crowns, open-faced S-S crowns, commercially veneered S-S crowns. But, all of these have limitation. Advances in restorative materials and metal-bonding procedures have made possible new restorative techniques that combine the advantages of S-S crowns with the cosmetics of composite restoration methods. The described technique of bonding composite to trimmed and fitted S-S crowns offers many advantages over other techniques currently used to restore primary anterior teeth. 1. If S-S crowns are accurate trimmed and contoured, good retention of crowns is achieved. 2. The patient time required is similar to that of conventional S-S crowns. 3. Good esthetics and high bond strengths are achieved. 4. It is possible to use this veneering technique intraorally on crowns that have fractured veneers.

  • PDF