• Title/Summary/Keyword: Crown area

Search Result 480, Processing Time 0.03 seconds

A PHOTOELASTIC STRESS ANALYSIS OF FIXED PARTIAL DENTURES WITH ENDOPOREIMPLANTS ACCORDING TO SPLINTING, CONTACT TIGHTNESS, AND CROWN LENGTH (연결고정, 인접면 접촉강도 및 치관길이에 따른 엔도포어 임플란트를 이용한 고정성 국소의치의 광탄성 응력 분석)

  • Jeong, Hoe-Yeol;Choi, Min-Ho;Kim, Yu-Lee;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.425-442
    • /
    • 2004
  • Statement of problem: A difficulty in achieving a passive-fitting prosthesis can be overcome by individual crown restoation of multiple implants. But individualized crown has another difficulty in control of contact tightness and stress distribution. Purpose: This in vitro study is to evaluate the stress distribution and the magnitude in the supporting tissues around Endopore implants with different crown lengths, interproximal contact tightness, and the splinting effects. Material & methods: Three Endopore implants($4.1{\times}9mm$) were placed in the mandibular posterior edentulous area distal to the canine and photoelastic model was made with PL-2 resin(Measurements Group, Raleigh, USA). Restorations were fabricated in two crown lengths: 9, 13 mm. For non-splinted restorations, individual crowns were fabricated on three custom-milled titanium abutments. After the units were cemented, 4 levels of interproximal contact tightness were evaluated: open, ideal($8{\mu}m$ shim stock drags without tearing), medium($40{\mu}m$), and heavy($80{\mu}m$). For splinted restorations, 3-unit fixed partial dentures were fabricated. This study was examined under simulated non-loaded and loaded conditions(6.8 kg). Photoelastic stress analysis was carried out to measure the fringe order around the implant supporting structure. Results: 1. When restorations were not splinted, the more interproximal contact tightness was increased among the three implants, the more stress was shown in the cervical region of each implant. When crown length was increased, stresses tended to increase in the apex of implants but there were little differences in stress fringes. 2. When nonsplinted restorations were loaded on the first or third implant, stresses were increased in the apex and cervical region of loaded implant. Regardless of interproximal contact tightness level, stresses were not distributed among the three implants. But with tighter interproximal contact, stresses were increased in the cervical region of loaded first or third implant. 3. When the nonsplinted restorations were not loaded, there were little stresses on the supporting structure of implants, but low level stresses were shown in the splinted restorations even after sectioning and soldering. 4. With splinted restorations, there were little differences in stresses between different crown lengths. When splinted restorations were loaded, stresses were increased slightly on the loaded implant, but relatively even stress distribution occurred among the three implants. Conclusions: Splinting the crowns of adjacent implants is recommended for Endopore implants under the overloading situation.

Comparison of occusal aspects in monolithic zirconia crown before and after occlusal adjustment during intraoral try-in: a case report (CAD/CAM으로 제작된 monolithic zirconia crown의 시적 전후 교합양상에 대한 비교)

  • Yong, Ki-Hoon;Shim, Jun-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.246-251
    • /
    • 2014
  • In case of prosthesis fabrication by CAD/CAM, location, area and contour of occlusal contacts can be adjusted so more functional occlusion can be acquired. Also, errors in a manufacturing process is reduced compared to cast metal prostheses and porcelain fused metal prostheses fabricated by conventional methods such as casting and porcelain build up. Therefore, prostheses by CAD/CAM show superior occlusion accuracy. Recently, virtual articulator function has been introduced to CAD/CAM system, which reproduces mandibular movement against maxilla. Thus, it is possible to consider occlusal interference in anterior/lateral movement as well as closing movement. There have been many studies on the marginal and internal fit of prostheses using zirconia but the occlusal fit of zirconia crown fabricated by CAD/CAM has not been researched as much. In this case report, 7 zirconia crowns were designed and fabricated by CAD/CAM for total 5 patients. The models of zirconia crowns before and after occlusal adjustment during intraoral try-in were scanned for occlusal contacts, which were compared to evaluate accuracy of prostheses and understand patterns of occlusal adjustment. Most of the occlusal adjustments were done on functional cusps and slopes of zirconia crown, and the magnitude of occlusal adjustment ranged from $15{\mu}m$ to $60{\mu}m$. In the zirconia crown fabricated with CAD/CAM systems, the occlusal adjustment is a necessary procedure, so additional procedures will be needed for compensating reduced mechanical properties.

A STUDY ON FRACTURE STRENGTH OF COLLARLESS METAL CERAMIC CROWN WITH DIFFERENT METAL COPING DESIGN (금속코핑 설계에 따른 Collarless Metal Ceramic Crown의 파절강도에 관한 연구)

  • Yun, Jong-Wook;Yang, Jae-Ho;Chang, Ik-Tae;Lee, Sun-Hyung;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.454-464
    • /
    • 1999
  • The metal ceramic crown is currently the most popular complete veneer restoration in dentistry, but in many cases, the metal cervical collar at the facial margin is unesthetic and unacceptable. Facial porcelain margin has been used in place of it. But this dose not solve the problems, such as dark gingival discoloration and cervical opaque reflection of porcelain veneer. Recently, metal copings which were designed to terminate its labio-cervical end on the axial walls coronal to the shoulder have been clinically used to solve the esthetic problem of metal ceramic crown. But in this design, porcelain veneer of labio-cervical area which is not supported by metal may not be able to resist the stress during cementation and mastication. The purpose of this study was to evaluate fracture strength and fractured appearance of crowns according to different coping designs. A resin maxillary left central incisor analogue was prepared for a metal ceramic crown, and metal dies were made with duplication mold. Metal copings were made and assigned to one of four groups based on facial framework designs: group 1, coping with 0.5mm metal collar; group 2, metal extended to the shoulder; group 3, metal extended to 1mm coronal tn the shoulder: group 4, metal extended to 2mm coronal to the shoulder. Copings and crowns were adjusted to be same size and thickness, and cemented to metal dies with zinc phosphate cement by finger pressure. Fracture strength was measured with Instron Universal Testing Machine. Metal dies were anchored in Three-way-vice at 3mm below finish line and at $130^{\circ}$ inclined to the long axis of the crown. Load was directed lingually at 2mm below midincisal edge. Load value at initial crack and at catastrophic fracture was recorded. The results obtained were as follows : 1. Fracture strength values at initial crack were higher in groups 1, 2 than in groups 3, 4 but this difference was not statistically significant(P<0.05). 2. Conventional metal collared crown had greater catastrophic fracture strength than any other collarless crowns. 3. The greater the labial metal coping reduction, the lower the catastrophic fracture strength of crowns but when more than 1mm of labial metal reduction was done, the difference in strengths was not statistically significant(p<0.05). 4. The strongest collarless coping design was group 2.

  • PDF

Changes of Spatial Distribution of Korean fir Forest in Mt. Hallasan for the Past 10 Years(2006, 2015) (최근 10년(2006~2015년) 동안 한라산 구상나무림의 공간분포변화)

  • Kim, Jong-Kab;Koh, Jung-Goon;Yim, Hyeong-Taek;Kim, Dong-Soon
    • Korean Journal of Environment and Ecology
    • /
    • v.31 no.6
    • /
    • pp.549-556
    • /
    • 2017
  • The purpose of this study was to investigate the change of spatial distribution of Korean fir (Abies koreana E. H. Wilson) in Mt. Hallasan for the past 10 years. We examined the distribution and crown density between 2006 and 2015 and analyzed the elevation, direction, and regional characteristics. The total area of Korean fir was 626.0ha in 2015, which declined by 112.3ha accounting for 15.2% for the past 10 years compared to 738.3ha in 2006. For the past 10 years, the area of moderately dense Korean fir with the crown density of 41% to 70% decreased by 72.6ha while the area of dense Korean fir with the crown density of 71% or more deceased by 21.3ha. The area with an elevation between 1,510m and 1,600m showed the largest change, accounting for 32.6% of the total declining area. Regarding the distribution by the direction, the area in the southeastern direction decreased by 23.4ha while the area in the southeast and northeast centered on the eastern direction decreased by 62.3ha, which accounted for 55.5% of the total area. Regarding the change of the distribution of Korean fir forest area by the region, the decrease of the area from the Jindallaebat to the top of the mountain was the largest at 84.6ha, or 71.8% of the total decreased area. The Yeongshil Trail area decreased by 25.3ha or 21.5% of the total while the Keundurewat area decreased by 8.0ha or 6.8%. On the contrary, the Bangaeoreum area increased by 5.6ha. The results indicate the large decrease of area of Korean fir forest centered on a particular location of Mt. Hallasan. Considering the changes according to the elevation, direction, and regional characteristics, it can be attributed to increasing frequency of abnormal climates such as typhoons and droughts.

A MORPHOMETRIC STUDY OF THE MAXILLARY PRIMARY FIRST MOLARS USING THREE-DIMENSIONAL SCANNER (3차원 스캐너를 이용한 상악 제1유구치 치관의 크기와 형태에 관한 연구)

  • Lee, Jong-Beom;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.643-652
    • /
    • 2006
  • The purpose of this study was to elucidate the size and morphologic characteristics of maxillary primary first molars in Korean children using three-dimensional laser scanner and compare three-dimensional image with preformed stainless steel crown. Scanned three-dimensional images of dental cast taken from 132 children(male 62, female 70) by three-dimensional laser scanner(Breuckmann opto-Top HE100, INUS, Korea) were used. Mesiodistal diameter, buccolingual diameter, occlusogingival height and crown shape of each image were calculated by Rapidform 2004 program(INUS, Korea). The values were statistically compared by independent samples t-test with 95% of significant level. The results were as follows : 1. No significant difference in crown size was found between left and right maxillay primary first molar(p>0.05). 2, Significant difference in mesiodistal diameter, buccolingual diameter, buccal occlusogingival height was found between male and female (p<0.05), and crown size of male was bigger than that of female. 3. Average image of maxillay primary first molar was shaped three-dimensionally and measured. In comparison with 3M stainless steel crown, this image was similar with No.4 or No.5 SS crown in male, No.4 in female. In comparison with ILSUNG SS crown, this image was similar with No.5 in male, No.4 in female. 4 Mesiolingual line angle area, distolingual line angle area and buccogingival ridge were more obvious in average image than 3M stainless steel crown. ILSUNG SS crown was more square and had longer mesiodistal diameter than average 3D image.

  • PDF

Changes of Species Diversity on Moth Communities at Forest Fire Region in Samcheok, Korea (삼척시산불지역에서의 나방류에 관한 종다양성 변화)

  • Bae, Yang-Seop;Chae, Do-Young;Ju, Young-Don;Bae, Jung-Hoon;Kim, Jong-Myung;Ahn, Neung-Ho;Lee, Cheol-Min
    • Korean journal of applied entomology
    • /
    • v.50 no.1
    • /
    • pp.7-14
    • /
    • 2011
  • We investigated moth communities in Samcheok, Korea, to elucidate the influence of the East Coast Fire in 2000. Moths were collected with UV light traps 4 times a year from 2006 to 2009 at 3 sites: Unburned area (Site 1), Surface fire area (Site 2), and Crown fire area (Site 3) sites, respectively. A total of 3,804 individuals belonging to 727 species from 30 families were captured at the 3 study 1,727 individuals of 505 species (27 families) at Site 1, 1,193 individuals of 353 species (24 families) at Site 2, and 885 individuals of 340 species (25 families) at Site 3. Species richness and individuals of Noctuidae, Pyralidae, Geometridae, and Tortricidae were the highest at all 3 sites. All of species richness, individuals, and species diversity (H') were the highest in Site 1 for 4 years. The index of similarity (${\alpha}$-Index) was higher between Site 2 and 3 in 2006, while higher between Site 1 and 2 in 2009. Moths were grouped into 16 categories by hosts of the larval stage. Individuals of moths of herbaceous feeding habit continuously decreased at Site 3, but proportion of individuals of tree feeding habits continuously increased. The present results showed that moth communities was relatively recovered according to vegetation change after forest fire and regeneration of moth communities in surface fire area was more faster than in crown fire area.

Within0tree Disribution of matsucoccus thunbergianae on Pinus thunbergiana (해송에서의 솔껍질깍지의 벌레 수상분포 양식)

  • 박승찬
    • Korean journal of applied entomology
    • /
    • v.33 no.2
    • /
    • pp.114-121
    • /
    • 1994
  • Population densities of intermediate nymphs and egg saw of Matsucoccus thunbergianae, a major insect pest of Pinus thunbergiona in southern coastal area of Korean peninsula, were est~mated. Tree samples of ca. 10cm D.B.H. were collected from old infestation area and newly invaded area. The numben of plimaly branches per tree were not significantly different by the locality, but those of secondaly and smaller branches were smaller in old infestation area The numbers of intermediate nymphs per tree in old infestation area and in newly invaded area were 10.8 and 13.1 times more than those on the trunk, respectively Approximately between 4, 200 and 208, 500 nymphs per tree were estimated. Men secondaw and smaller bmnch samples collected from the basal part of middle crown height, or from the central or the basal part of lower crown height, the number of samples required for the emr range of 20% were 21 and 11 far 10-20cm and 20-3 crn long branches, respectively. Approx~mately 63.6% of egg sacs of the whole tree were on the trunk. The node/intemode bearing the largest branch had the highest egg sac density; including that, four adjacent nodes/intemodes had ca. 37% of egg saw on the trunk.

  • PDF

Report on Forests Damaged Due to Cutting Trees Infected by Pine Wilt Disease (소나무재선충 고사목 제거에 따른 산림훼손 보고)

  • Hong, Suk-Hwan;Lee, Soo-Dong
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.4
    • /
    • pp.590-598
    • /
    • 2015
  • Despite various control methods for pine wilt disease, the disease has been increasing at an alarming rate every year in Korea. Still there is a lack of research on the problems of the current methods used to curb the disease. One main method to control pine wilt disease is fumigation for eliminating the larva of the pine sawyer beetle (Monochamus alternatus) which is known as the vector insect for pine wilt disease. We surveyed and analyzed the amount of destroyed uninfected trees in the fumigated area by studying 32 survey plots ($100m^2$) in Miryang city. The destroyed trees' crown area was estimated by induced regression between root collar area and crown area of the remaining trees (coniferous tree: $R^2=57.4$, deciduous broad-leaved tree: $R^2=63.8$). According to the analysis results, the infected trees (cut trees) were 18.7% and cut trees which were not infected were 35.5% of the total tree population of the study area on the basis of total crown area. In case of pine trees, 8.4% of uninfected trees were cut off but 62% of uninfected deciduous broad-leaved trees including Quercus spp. were affected and damaged during the fumigation process. Since these broad-leaved trees dominate the sub-canopy layer of the forest, this indiscriminate interruption of broad-leaved trees has the adverse effect of depriving the public benefits such as shadow, a cooler weather, controlling humidity, etc.

Diameter Growth Characteristics of Quercus mongolica and Quercus variabilis in Natural Deciduous Forests (천연활엽수림(天然濶葉樹林)내 신갈나무와 굴참나무의 직경생장(直徑生長) 특성(特性))

  • Choi, Jung-Kee;Yoo, Byoung-Oh
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.1
    • /
    • pp.131-138
    • /
    • 2006
  • This study was conducted to assess the diameter growth patterns of Quercus mongolica and Quercus variabilis dominant species in natural deciduous forests in Korea. The diameter growth data were collected from 83 destructively sample trees for stem analysis in Gangwon-Do region. The relationship between diameter growth and 14 tree measurements was also analyzed. The average diameter growth rate of dominant trees for both species increased until ages of 15-20 years, and exhibited generally constant trend for subsequent ages. The diameter growth rate of both species ranged from 0.09-0.83 cm/yr across the all ages. Average annual diameter growth for last 5 measurement years was 0.28 cm/yr for Quercus mongolica and 0.27cm/yr for Quercus variabilis. The observed growth rate decreased with decreasing crown class. The difference between diameter growth rates for different crown classes was only statistically significant (p<0.0001) for Quercus mongolica. Pearson correlation coefficient between the diameter growth rate decreased with relative diameter (r=0.64), relative height (r=0.61), exposed crown area (r=0.58) and total crown area (r=0.56) for Quercus mongolica. For Quercus variabilis, Pearson correlation coefficient decreased with dbh (r=0.57), crown width (r=0.55), age (r=0.39), competition index (r=-0.39), and height (r=0.35).

Electrochemical Immunosensing of GOx-labeled CRP Antigen on Capture Antibody Monolayer Immobilized on Calixcrown-5 SAMs

  • Jung, Hye-Sook;Song, Kum-Soo;Kim, Tai-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.10
    • /
    • pp.1792-1796
    • /
    • 2007
  • Insulating effects on Au electrode according to the thickness and density of coated materials are well-known. To do electrochemical immunoassay reproducibly the glod electrode would be coated with self-assembled monolayers and antobodies. To get reproducibility, the antobody monolayer should be packed at highest density so that the amount of immobilized antibody at defined area should be the same. The calix[4]crown-5 SAMs could provide the basis for the antibodies to be immobilized reproducibly and at highest density. But the insulating effect would be highest too. We proved that the compactly packed protein monolayers on SAMs inhibited the electron transfer by block the free shuttling of redox molecules. The inhibition was minimized by inserting redox molecules in between the proteins during immobilization process. In this paper, we demonstrated that the calix[4]crown-5 SAMs would provide the protein monolayers with highest density and new method to minimize the insulating effect by inserted redox molecules in between the compactly packed protein monolayers.