• Title/Summary/Keyword: Crosslinked polyethylene

Search Result 71, Processing Time 0.034 seconds

Relationship between Crosslinking Processes and Mechanical Properties of UHMWPE for Artificial Joint (인공관절용 초고분자량폴리에틸렌의 가교결합 공정변수와 기계적 특성과의 상관관계)

  • Kim, H.M.;Kim, S.K.;Lee, J.D.;Yun, I.S.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1570-1574
    • /
    • 2008
  • Various mechanical test were conducted on conventional and crosslinked ultra-high molecular weight polyethylene(UHMWPE) all prepared from the same lot of medical grade GUR 1050 for artificial joint. The conventional materials were not irradiated and treated by heating. The cosslinked materials were irradiated with $25kGy{\sim}200kGy$ by gamma-ray andthen annealed or remelted. Gamma-ray irradiation and heat treatment process were found to significantly impact the crystallinity, and hence the mechanical behavior, of the highly crosslinked UHMWPE. The radiation dose and heating conditions were key predictors of the uniaxial yielding, plastic flow, and failure properties of conventional and highly crosslinked UHMWPE. The correlation model from experiments would be the basic information to enhance the were resistance of artificial joint liner.

  • PDF

Evaluation of Radiation Degradation or Crosslinked Polyethylene using TGA (TGA를 이용한 가교폴리에틸렌의 방사선 열화 평가)

  • Lee, Chung;Kim, Ki-Yup;Ryu, Boo-Hyung;Lim, Kee-Joe
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.50-55
    • /
    • 2003
  • Radiation degradation of crosslinked polyethylene(XLPE) was investigated using thermogravimetric analysis(TGA), The results of TGA were compared with FT-IR, melting temperature, oxidation induction time, and elongation at break on the XLPE exposed by $\gamma$-ray. 5% decomposition temperature of $\gamma$-ray irradiated XLPE showed similar tendencies with the case of elongation at break. Both properties agreed below 1000 KGy, however, did not show any remarkable characteristics above 1000 kGy, these properties can be useful to evaluate the radiation degradation of XLPE for only low irradiated region. Above 1000 kGy, the thermal decomposition activation energy showed decreased, on the contrary, increasing below 1000 kGy. Compared with FT-IR spectrum of irradiated XLPE, it was confirmed that the oxidation reaction was still occurring below 1000 kGy. Radiation degradation of XLPE was dependent upon the irradiation doses, TGA can be a useful tool to evaluate the degradation.

Charge Distributions in Polyethylene/Ethylene n-Butyl Acrylate Blends (Polyethylene/Ethylene n-Butyl Acrylate Blends의 전하형성특성)

  • Kim, Ok;Lee, Chang-R.;Lee, Mi-Kyung;Suh, Kwang-S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.143-147
    • /
    • 1995
  • The space charge formation in polyethylene (PE)/ethylene n-butyl acrylate (EnBA) blends were investigated. Heterocharge was found in PE and EnBA containing 5 mole% of nBA while homocharge was found in EnBAs containing 19 and 20% of nBA. All PE/EnBA blends except the one with the EnBA containing 5% nBA showed heterocharge formation. Heterocharge was also found in crosslinked PE/EnBA blends, which was attributed to the volatile residuals generated by the thermal decomposition of peroxide.

  • PDF

Characteristics of Heat Shrinkable High Density Polyethylene Crosslinked by ${\gamma}$-Irradiation

  • Kang, Phil-Hyun;Nho, Young-Chang
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.184-191
    • /
    • 2001
  • The effects of ${\gamma}$-irradiation on the crosslinking of high density polyethylene (HDPE) was investigated for the purpose of obtaining a suitable formulation for heat shrinkable materials. In this study the HDPE specimens were prepared by blending with cross linking agents and pressed into a 0.2 mm sheet at 18$0^{\circ}C$. ${\gamma}$-irradiation was conducted at 40 to 100 kGy in nitrogen. The heat shrinkable property and thermal mechanical property of the HDPE sheets have been investigated. It was found that the degree of crosslinking of the irradiated HDPE samples were increased with irradiation dose. Compared with the HDPE containing triallylisocyanurate, the HDPE containing trimethylol propane triacrylate shows a slight increase in crosslinking density. The heat transformation and dimension change of HDPE decreased with increasing radiation dose. The heat shrinkage of the samples increased with increasing annealing temperatures. The thermal resistance of HDPE increased upon the crosslinking of HDPE.

  • PDF

Drug Release Characteristics of Crosslinked Poly(alkylene oxide) Hydrogels (가교된 폴리 알킬렌 옥사이드 하이드로겔의 약물방출 특성)

  • Kim, Shin-Jeong;Lee, Seung-Jin
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.2
    • /
    • pp.91-95
    • /
    • 1991
  • Polyethylene glycol, polypropylene glycol and block copolymer of ethylene glycol and propylene glycol were crosslinked by triisocyanate to form water swellable, rubbery polymer. The equilibrium swelling of the hydrogels ranged from 3% to 60% according to the hydrophobic-hydrophilic properties of the prepolymers. Model drugs, sodium salicylate and prednisolone were incorporated in the polymer matrices by swelling loading. Physical properties of the drugs affected the drug release mechanisms due to the change in the swelling behaviors of the polymeric devices. Zero order release was observed in the case of relatively hydrophobic polymer matrices.

  • PDF

Water Tree Characteristics of Crosslinked Polythylene (가교 폴리에틸렌의 수트리 특성)

  • Nam, Jin-Ho;Kim, Woong;Kim, Hyeon-Seok;Kim, Joon-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.295-295
    • /
    • 2008
  • Water tree experiments were done for several types of cross-linked polyethylenes. Test method is followed by ASTM D6097. Polyethylene is divided for four subgroup. First One is chemically cross-linked general XLPE, and second one is chemically cross-linked tree-retardant XLPE, and the third one is silane cross-linked polyethylene made by monosil process, and the last one is silane cross-linked polythylene made by copolymer. Tree retardant XLPE shows the shortest water tree length. Cahemcally cross-linked general XLPE shows the longest water tree length. Silane cross-linked polyethylene by copolymer is similar to tree retardant XLPE and similar breakdown strength. So silane cross-linked XLPE by copolymer could be used for the the medium voltage cable which should have tree retardant characteristics.

  • PDF

Ionic Impurities and Dielectric Breakdown of XLPE (이온성 불순물과 폴리에틸렌의 절연파괴특성)

  • 윤종복;서광석;변재동;한재홍;김상준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.58-61
    • /
    • 1997
  • Effects of ionic impurities on the dielectric breakdown of the crosslinked polyethylene (XLPE) were studied using aqueous electrolytes. It was found that the AC breakdown strength of XLPE decreases considerably when the ions are present in the electrodes composed of aqueous electrolyte. Details of results were described.

  • PDF

Variations of the Electrical Treeing and Breakdown Characteristics on LDPE Due to Gamma-ray Irradiation

  • Lee, Chung;Ryu, Boo-Hyung
    • International Journal of Safety
    • /
    • v.8 no.1
    • /
    • pp.14-17
    • /
    • 2009
  • The $Co^{60}$ $\gamma$-ray irradiation effects on the electrical and thermal characteristics of low density polyethylene crosslinked by Dicumyl peroxide (DCP) were investigated. We experimented on electrical properties as following; electrical tree inception and growing type for applying AC step voltage, AC breakdown strength, volume resistivity with increasing dosage. Also, chemical analyses were performed TGA, gel fraction. These electrical properties changed depending upon its crosslinking degree and byproducts from crosslinking reactions. Crosslinking reactions were considered causing by $\gamma$-ray irradiation and DCP had contained in low density polyethylene.

Synthesis and Physical Properties of Biocompatible and Biodegradable Polypeptide Copolymers(II) (생체적합성과 생분해성을 갖는 Polypeptide Copolymer의 합성과 물성에 관한 연구(II))

  • 강인규;권대룡
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.237-242
    • /
    • 1989
  • The physical properties and drug release behaviours of polyethylene glycol grafted poly ${\gamma}$- benzyl L-glutamate (PEG- g- PBLG), polyethylene glycol crosslinked poly ${\gamma}$-benzyl L- glutamate(PEG-c-PBLG), and PBLG homopolymer are compared. PBLG containing PEG segements showed higher wettability and larger enlongation than PBLG homoplymer, but lower elastic modulus. The release rate of rhodamine is strongly influenced by the wettability of the polymer. Rhodamine is more rapidly released from PEG-c-PBLG membrane having a larger water contact angle than from other polymer having a lower water contact angle. The surfaces of PBLG derivative membranes are modified by substitution reaction using hydroxyalkylamine. The resulting polymer membranes showed hider wettability and swelling ratio than virgin membranes.

  • PDF

The Improvement of Radiation Characteristics of Low Density Polyethylene by Adding Treeing Inhibitors (I) (트리억제제 첨가에 의한 저밀도 폴리에틸렌의 내방사선성 향상 (I))

  • Kim, Ki-Yup;Lee, Chung;Ryu, Boo-Hyung;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.926-928
    • /
    • 1999
  • Treeing inhibitors of barbituric acid derivatives effects on the electrical properties of crosslinked low density polyethylene under radiation environments were investigated. The electrical parameters for tree inception voltage, AC breakdown strength, volume resistivity, capacitance and dissipation factor at 1MHz and thermoluminescence, gel content measurements were discussed as a function of irradiated dosages. From the results, barbituric acid among the treeing inhibitors was shown the best treeing and radiation resistance.

  • PDF