• Title/Summary/Keyword: Cross-sectional Study

Search Result 5,002, Processing Time 0.04 seconds

Experimental Study on the Unsteady Flow under Various Operating Conditions of a Counter Rotating Axial Flow Fan (엇회전식 축류팬의 작동조건 변화에 따른 비정상 유동에 관한 실험적 연구)

  • Kang, Hyun-Koo;Cho, Lee-Sang;Cho, Jin-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1389-1394
    • /
    • 2004
  • Experiments were done for the unsteady flow in a counter rotating axial flow fan near peak efficiency and stall point. Flow fields in a counter rotating axial flow fan were measured at cross-sectional planes of the upstream and downstream of each rotor. Cross sectional passage flow patterns were investigated through the acquired data by the $45^{\circ}$ inclined hot-wire. Comparison of flow characteristics between two different operating conditions such as tip vortex, secondary flow and turbulence intensity were performed through the analyses of axial, radial and tangential velocity distributions. As a result, tip vortex and secondary flows are enforced and measured obviously at stall point.

  • PDF

Effect of Tube Area on the Impulse Wave Discharged from the Exit of Tube (관출구로부터 방출되는 펄스파에 미치는 관단면적의 영향)

  • Shin, Hyun-Dong;Lee, Young-Ki;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.544-549
    • /
    • 2003
  • When a shock wave arrives at an open end of tube, an impulse wave is discharged from the tube exit and causes serious noise and vibration problems. In the current study, the effect of the cross-sectional area of tube on the impulse wave is numerically investigated using a CFD method. The Harten-Yee's total variation diminishing(TVD) scheme is used to solve the axisymmetric, two-dimensional, unsteady, compressible Euler equations. With three different cross-sectional areas of tube, the Mach number of the incident shock wave $M_{s}$ is varied between 1.01 and 1.5. The results obtained show that the directivity and magnitude of impulse wave strongly depend upon the Mach number of incident shock wave and are influenced by the tube area. It is also known that the tube cross-sectional area significantly affects the magnitude of impulse wave at or near the tube axis.

  • PDF

Out-line Space-Shape Variation of Clothing Fitness with Body by Useing the Image Processing (영상처리법을 이용한 의복의 착의 공간 형상 변화)

  • 이수정;윤진경;홍정민
    • Korean Journal of Human Ecology
    • /
    • v.2 no.1
    • /
    • pp.110-113
    • /
    • 1999
  • Clothing shape is principally described in seven factors that are composed of clothing design, clothing material, clothing size, pattern design, sewing method and body motion etc. The aims of this study was to measurement out-line space-shape variation of clothing fitness with body by using the image processing. The subjects for direct anthropometric measurements were 248 female college students aged from 19 to 22. The data were statistically analyzed by principal analysis and cluster analysis. The results selected one somatotype. for the out-line space-shape variation of clothing fitness with body, there dimensional clothing shapes measured. and cross-sectional clothing shape obtained by the measurement was considered to be space wave form. The out-line space-shape variation of clothing fitness with body was observed between the node number and amplitudes of clothing wave form, and node number was determined at the maxim of space-shape amplitude, and the space-shape amplitudes have related with aspect ratio of cross-sectional shape. (Korean J of Human Ecology 2(1) :110-113, 1999)

  • PDF

Numerical Study on the Turbulent Flow in the $180^\circ$ Bends increasing Cross-sectional Aspect Ratio (단면의 폭이 증가하는 $180^\circ$ 곡덕트 내 난류유동의 수치해석적 연구)

  • 김원갑;김철수;최영돈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.804-810
    • /
    • 2004
  • This paper reports the characteristics of the three dimensional turbulent flow by numerical method in the 180 degree bends with increasing cross-sectional area. Calculated pressure and velocity, Reynolds stress distributions are compared to the experimental data. Turbulence model employed are low Reynolds number $textsc{k}$-$\varepsilon$ model and algebraic stress model(ASM). The results show that the main vortex generated from the inlet part of the bend maintained to outlet of the bend and vortices are continually developed at the inner wall region. The distribution of turbulent kinetic energy along the bend are increase up to 120$^{\circ}$ because of increment of cross-sectional area. Secondary flow strength of the flow is lower about 60% than that of square duct flow.

Comparison of Muscle Architecture of Lower Extremity using Rehabilitative Ultrasound Image in Young Adults: a Comparative Study of Muscle Cross-sectional area of Lower Extermity of Seoul and Hanoi in Vietnam (재활 초음파 영상을 이용한 젊은 성인의 하지 근 구조 비교: 서울과 하노이 하지 근 단면적비교 연구)

  • Lee, Hwang-Jae;Kim, Min-Kyu;Ha, Hyun-Geun;Lee, Wan-Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.5
    • /
    • pp.324-330
    • /
    • 2014
  • Purpose: The aim of the current study was to compare the muscle architecture of lower extremity using rehabilitative ultrasound imaging (RUSI) in young adults in Seoul and Hanoi. Methods: The study design was a comparative study of muscle cross-sectional area of lower extremity. Sixty healthy young subjects (Seoul group: 30, Hanoi group: 30) participated in this study. Real-time B-mode RUSI with a 7.5MHz linear transducer was used for measurement of cross-sectional area, pennation angle, and muscle thickness of the rectus femoris, tibialis anterior, and medial gastrocnemius muscles. Independent t-test was used for statistical analysis. Results: Significant difference in cross sectional area of rectus femoris was observed between Korean young adults and Hanoi young adults (p<0.01). Muscle thickness and pennation angle of tibialis anterior in Korean young adults were greater than in Hanoi young adults (p<0.01). In addition, the muscle thickness and pennation angle of the medial part of gastrocnemius muscle were greater in Korean young adults than in Hanoi young adults (p<0.01). In addition, in the results for gender, men had larger muscle architectures than women in both groups (p<0.01). Conclusion: This study, using RUSI, showed significant difference in muscle architectures of lower extremity in a diverse group of young adults RUSI.

Relationship of trunk muscle atrophy and provocation position in patients with chronic low back pain

  • Shin, Doo Chul;Song, Chang Ho
    • Physical Therapy Rehabilitation Science
    • /
    • v.1 no.1
    • /
    • pp.28-32
    • /
    • 2012
  • Objective: The purpose of this study is to compare chronic low back pain patients' pain provocation position so as to identify the relevance with lumbar stabilizing muscles atrophy and pain provocation position. Design: Cross-sectional study. Methods: Fifty five chronic low back pain patients were participated in this study. Subjects were eligible for study participation if they were 35-55 years old and had experienced low back pain for more than 3 months. Subjects were questioned about pain and pain provocation test were done. And then they were inspected their cross sectional area (CSA) of lumbar muscles (erector spinae, iliopsoas, and multifidus) by using computed tomography. Analyze the relevance through the result data with painful area, aspect of pain and pain provocation position. Results: CSA of erector spinae showed significant decrease on ipsilateral extension position (p<0.05). Iliopsoas muscle showed significant decrease on contralateral position (p<0.05). Multifidus showed significant decrease on the position of contralateral extension and contralateral flexion (p<0.05). Conclusions: Based on the results of our study, it may be possible to evaluate muscle atrophy by assessing causing position.

  • PDF

COVID-19 Impact on the Quality of Life of Teachers: A Cross-Sectional Study

  • Rabacal, Judith S.;Oducado, Ryan Michael F.;Tamdang, Khen A.
    • Asian Journal for Public Opinion Research
    • /
    • v.8 no.4
    • /
    • pp.478-492
    • /
    • 2020
  • The COVID-19 global health crisis has affected the mental and psychological health and well-being of the people around the world. However, little is known about the impact of COVID-19 among Filipino teachers. This study was conducted to determine the impact of the COVID-19 pandemic on the quality of life (QoL) of professional teachers in the Philippines. A descriptive cross-sectional study was used involving 139 licensed professional teachers. The COVID-19 Impact on Quality of Life (COV19-QoL) was the primary measure used in this study. Descriptive statistics, t-test, and one-way ANOVA were the statistical tools employed to analyze the data. Results indicated a moderate COVID-19 impact on the QoL of the teachers. There was a significant difference in the impact of COVID-19 on QoL by degree program. However, the impact of COVID-19 on QoL did not significantly differ by age, sex, marital status, employment status, monthly salary, presence of a COVID-19 case near their residence, personal knowledge of someone who was infected or died of COVID-19, presence of a medical condition, and perceived threat. The psychological well-being and QoL of teachers must be recognized and teachers must be provided with support as they continue to adapt to the impact brought by the COVID-19 pandemic. This study contributes to the growing literature on the impact of the pandemic.

Study on the Characteristics of Impulse Wave Discharged from the Tube Exit with Non-Circular Cross-Section (비원형 관출구로부터 방출되는 펄스파의 특성에 관한 연구)

  • Shin, Hyun-Dong;Kweon, Yong-Hun;Lee, Young-Ki;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.550-555
    • /
    • 2003
  • When a shock wave arrives at an open end of tube, an impulse wave is discharged from the tube exit and complicated flow is formed near tube exit. The flow field is influenced by the cross-sectional geometry of tube exit, such as circular, square, rectangular, trapezoid and etc. In the current study, three-dimensional propagation characteristics of impulse wave discharged from the tube exit with non-circular cross section are numerically investigated using a CFD method. Total variation diminishing (TVD) scheme is used to solve the three-dimensional, unsteady, compressible Euler equations. Computations are performed for the Mach numbers of the incident shock wave $M_{s}$ below 1.5. The results obtained show that the peak pressure of the impulse wave and propagation directivity depends on the cross-sectional geometry of tube exit and the Mach number of incident shock wave.

  • PDF

Study of the Method to Examine the Cause of Damage to a Flat-Type Vinyl Cord (VFF) According to the Type of Energy Source (에너지원의 종류에 따른 비닐평형코드(VFF)의 소손원인 판정기법에 관한 연구)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.83-88
    • /
    • 2011
  • This study presented the structure and characteristics of vinyl cords used for wiring electric equipment and appliances and analyzed the photographs of damaged flat-type vinyl cords (VFF, $1.25mm^2$) and the metallic cross-sectional structure of melted conductors. Normal VFFs were made by twisting several strands together and the surface of the conductor was red brown. In addition, from the analysis of the metallic structure of the conductor, it was found that its grains had been elongated. The surface of a VFF damaged by normal flame showed no sheen with carbonized insulation material fused on the conductor surface. In addition, from the analysis of the cross-sectional structure of the melted area, it was found that voids of a certain shape were formed on it but that the cord's own elongation structure could not be checked. The cross-sectional analysis of the melted conductor damaged by the external flame applied to a VFF to which electric current was being applied showed no elongation structure for each cord, and revealed that irregular voids and a columnar structure had grown. The surface of the VFF damaged by overcurrent was uniformly carbonized and the cross-sectional structure analysis of the melted conductor revealed that the dendritic structure had grown. The analysis of the characteristics of the VFF melted by short-circuit showed that even though some part of the surface was contaminated, it showed little sheen and that the area rebounded by melting was round in shape. In addition, the cross-sectional structure analysis using a metallurgical microscope showed the boundary surface and columnar structure and revealed an amorphous structure like normal copper at areas other than the melted conductor.

Study on the Irregular Shape Rolling Process (비대칭 형상 압연 공정에 대한 연구)

  • 김용철;김동진;김병민
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.98-106
    • /
    • 1999
  • In this study cold rolling process for the irregular cross-sectional shape has been investigated. The product analyzed in present study is the steel cutter, which is frequently used to cut the desired shape on leather. Because steel cutter always has a irregular cross-section, after rolling process the workpiece is severely bended to every direction. The bending of the workpiece affects the processed performed after rolling such as heat treatment and grinding, then that of the workpiece becomes more severe. In this study, therefore, to prevent the bending of the workpiece to the left and right sides. rigid-plastic finite element method has been utilized and in order to find optimal roll geometry rapidly, one dimensional equal interval search technique has been also introduced. By using both rigid plastic finite element method and optimum technique, cold rolling process for the irregular cross-sectional shape has been successfully investigated.