• 제목/요약/키워드: Cross-member

검색결과 358건 처리시간 0.021초

건강결과와 건강결정요인간의 횡단면 시계열 연구 : 주요 OECD 국가를 대상으로 (Analysis of Health Promotion determinants in Major OECD Countries: A pooled cross-sectional time series)

  • 최윤정;배성일;이영호;강민선
    • 보건행정학회지
    • /
    • 제19권4호
    • /
    • pp.33-52
    • /
    • 2009
  • Health promotion policies have needed to assess in detailed and evidence-based work to set a policy goal and clear future directions of health promotion in Korea. To identify the major factors related with health promotion, we assessed the associations between public health outcome (potential years of life loss, PYLL) and national health determinants. For this purpose, we used a pooled cross sectional time-series regression analysis with corrected fixed effect models involving sixteen member countries of the Organisation for Economic Cooperation and Development during the period 1970 to 2001. The PYLL was positively associated with tobacco and alcohol consumption (model 1 and 2) and calories intake (model 2 and 3) while the PYLL was negatively associated with GDP, fruit and vegetable intake (model 2), number of doctors (model 3), coverage rates of health care security, and elderly population rates (model 4). In conclusion, health behaviors related with tobacco, alcohol, and nutrition were significant health determinants for health outcome. Overall analysis results of this study will provide a guidance toward improved macro- and micro-policy development for future health promotion policy in Korea.

Behavior and design of perforated steel storage rack columns under axial compression

  • El Kadi, Bassel;Kiymaz, G.
    • Steel and Composite Structures
    • /
    • 제18권5호
    • /
    • pp.1259-1277
    • /
    • 2015
  • The present study is focused on the behavior and design of perforated steel storage rack columns under axial compression. These columns may exhibit different types of behavior and levels of strength owing to their peculiar features including their complex cross-section forms and perforations along the member. In the present codes of practice, the design of these columns is carried out using analytical formulas which are supported by experimental tests described in the relevant code document. Recently proposed analytical approaches are used to estimate the load carrying capacity of axially compressed steel storage rack columns. Experimental and numerical studies were carried out to verify the proposed approaches. The experimental study includes compression tests done on members of different lengths, but of the same cross-section. A comparison between the analytical and the experimental results is presented to identify the accuracy of the recently proposed analytical approaches. The proposed approach includes modifications in the Direct Strength Method to include the effects of perforations (the so-called reduced thickness approach). CUFSM and CUTWP software programs are used to calculate the elastic buckling parameters of the studied members. Results from experimental and analytical studies compared very well. This indicates the validity of the recently proposed approaches for predicting the ultimate strength of steel storage rack columns.

Analytical model for high-strength concrete columns with square cross-section

  • Campione, G.
    • Structural Engineering and Mechanics
    • /
    • 제28권3호
    • /
    • pp.295-316
    • /
    • 2008
  • In the present paper a mechanical model to predict the compressive response of high strength short concrete columns with square cross-section confined by transverse steel is presented. The model allows one to estimate the equivalent confinement pressures exercised by transverse steel during the loading process taking into account of the interaction of the stirrups with the inner core both in the plane of the stirrups and in the space between two successive stirrups. The lateral pressure distributions at hoop levels are obtained by using a simple model of elastic beam on elastic medium simulating the interaction between stirrups and concrete core, including yielding of steel stirrups and damage of concrete core by means of the variation in the elastic modulus and in the Poisson's coefficient. Complete stress-strain curves in compression of confined concrete core are obtained considering the variation of the axial forces in the leg of the stirrup during the loading process. The model was compared with some others presented in the literature and it was validated on the basis of the existing experimental data. Finally, it was shown that the model allows one to include the main parameters governing the confinement problems of high strength concrete members such as: - the strength of plain concrete and its brittleness; - the diameter, the pitch and the yielding stress of the stirrups; - the diameter and the yielding stress of longitudinal bars; - the side of the member, etc.

Axial compressive strength of short steel and composite columns fabricated with high stength steel plate

  • Uy, B.
    • Steel and Composite Structures
    • /
    • 제1권2호
    • /
    • pp.171-185
    • /
    • 2001
  • The design of tall buildings has recently provided many challenges to structural engineers. One such challenge is to minimise the cross-sectional dimensions of columns to ensure greater floor space in a building is attainable. This has both an economic and aesthetics benefit in buildings, which require structural engineering solutions. The use of high strength steel in tall buildings has the ability to achieve these benefits as the material provides a higher strength to cross-section ratio. However as the strength of the steel is increased the buckling characteristics become more dominant with slenderness limits for both local and global buckling becoming more significant. To arrest the problems associated with buckling of high strength steel, concrete filling and encasement can be utilised as it has the affect of changing the buckling mode, which increases the strength and stiffness of the member. This paper describes an experimental program undertaken for both encased and concrete filled composite columns, which were designed to be stocky in nature and thus fail by strength alone. The columns were designed to consider the strength in axial compression and were fabricated from high strength steel plate. In addition to the encased and concrete filled columns, unencased columns and hollow columns were also fabricated and tested to act as calibration specimens. A model for the axial strength was suggested and this is shown to compare well with the test results. Finally aspects of further research are addressed in this paper which include considering the effects of slender columns which may fail by global instabilities.

Determination of strut efficiency factor for concrete deep beams with and without fibre

  • Sandeep, M.S.;Nagarajan, Praveen;Shashikala, A.P.;Habeeb, Shehin A.
    • Advances in Computational Design
    • /
    • 제1권3호
    • /
    • pp.253-264
    • /
    • 2016
  • Based on the variation of strain along the cross section, any region in a structural member can be classified into two regions namely, Bernoulli's region (B-region) and Disturbed region (D-region). Since the variation of strain along the cross section for a B-region is linear, well-developed theories are available for their analysis and design. On the other hand, the design of D-region is carried out based on thumb rules and past experience due to the presence of nonlinear strain distribution. Strut-and-Tie method is a novel approach that can be used for the analysis and design of both B-region as well as D-region with equal importance. The strut efficiency factor (${\beta}_s$) is needed for the design and analysis of concrete members using Strut and Tie method. In this paper, equations for finding ${\beta}_s$ for bottle shaped struts in concrete deep beams (a D-region) with and without steel fibres are developed. The effects of transverse reinforcement on ${\beta}_s$ are also considered. Numerical studies using commercially available finite element software along with limited amount of experimental studies were used to find ${\beta}_s$.

Performance of Adhesives in Glulam after Short Term Fire Exposure

  • Quiquero, Hailey;Chorlton, Bronwyn;Gales, John
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.299-311
    • /
    • 2018
  • As engineered timber such as Glulam is seeing increasing use in tall timber buildings, building codes are adapting to allow for this. In order for this material to be used confidently and safely in one of these applications, there is a need to understand the effects that fire can have on an engineered timber structural member. The post-fire resilience aspect of glulam is studied herein. Two sets of experiments are performed to consider the validity of zero strength guidance with respect to short duration fire exposure on thin glulam members. Small scale samples were heated in a cone calorimeter to different fire severities. These samples illustrated significant strength loss but high variability despite controlled quantification of char layers. Large scale samples were heated locally using a controlled fuel fire in shear and moment locations along the length of the beam respectively. Additionally, reduced cross section samples were created by mechanically carving a way an area of cross section equal to the area lost to char on the heated beams. All of the samples were then loaded to failure in four-point (laterally restrained) bending tests. The beams that have been burnt in the shear region were observed as having a reduction in strength of up to 34.5% from the control beams. These test samples displayed relatively little variability, apart from beams that displayed material defects. The suite of testing indicated that zero strength guidance may be under conservative and may require increasing from 7 mm up to as much as 23 mm.

주거용 내화단면 중공슬래브의 휨거동 평가 (A Evaluation on Flexural Behavior for Hollow Core Slab of Fire Resistance section for Residence Building)

  • 부윤섭;배규웅;신상민
    • 한국공간구조학회논문집
    • /
    • 제23권2호
    • /
    • pp.61-68
    • /
    • 2023
  • A two-hour fire-resistance PC hollow slab for residential use was developed to secure structural and fire-resistance performance and to be applied to the general building and apartment housing markets. Compared to the existing hollow slab, in order to secure the same or better structural performance and economic feasibility by reducing the quantity, it was attempted to secure the fire resistance performance by reducing the concrete filling rate in the cross section and adjusting the thickness of the upper and lower flanges by optimizing the hollow shape in the cross section of the slab. For structural performance evaluation, experiments were performed on PC hollow slabs by varying the member thickness and the presence or absence of overlaid concrete, and all of the experimental results showed that the design strength was sufficiently exhibited and that stability during construction was possible. The developed synthetic PC hollow slab has secured fire resistance and residential performance so that it can be applied to all buildings, and it is intended to be immediately applied to the field.

Fire Behavior of Reinforced Concrete Filled Square Steel Tube Columns Under Constant Axial Loads

  • Jeeyoung Lee;Seulgi Han;Jinwon Shin;Inrak Choi;Sungmo Choi
    • 국제초고층학회논문집
    • /
    • 제13권1호
    • /
    • pp.85-95
    • /
    • 2024
  • A composite member made of concrete-filled steel tubes (CFT columns) has been recognized for its fire resistance due to the thermal mass effect of concrete inside the steel tube, as shown in various studies. In this study, the fire resistance performance of reinforced CFT columns under constant axial load was evaluated using finite element analysis with ABAQUS. For this purpose, the variables including cross-section size, steel tube thickness, and concrete cover thickness were set, and the temperature distribution in the column cross-section exposed to a standard fire was investigated using heat transfer analysis. Ultimately, a P-M interaction curve was obtained by evaluating the overall residual strength of columns, and the fire resistance time was determined by evaluating axial displacement-time responses due to the reduction in load capacity during fire through stress analysis.

전력선 단선으로 인한 이상시 송전철탑의 안전성 평가방법 (Safety Evaluation Method of Transmission Tower Subjected to Special Load Case According to Broken Wires)

  • 진석원;김종민;박종섭;강영종
    • 한국강구조학회 논문집
    • /
    • 제20권1호
    • /
    • pp.131-149
    • /
    • 2008
  • 최근 급증하는 전력수요 충족을 위해 송전선로 및 송전철탑의 대형화가 진행되고 있다. 국내 송전철탑 설계기준에서는 선로방향하중에 대해 상시와 이상시로 구분하여 검토하고 있다. 송전철탑 붕괴의 가장 큰 원인이 되고 있는 선로 단선으로 인한 이상시 철탑 주재의 안전성 검토가 필요하다. 국내 설계기준은 축력이 지배적인 트러스요소를 철탑에 적용하고 있으며, 단선으로 인한 불평형 하중을 암끝단에 재하하도록 하고 있다. 불평형 하중을 유발하는 단선은 두 곳에서 동시에 발생하는 경우까지 고려하고 있으며, 그 이상 여러 상의 전선이 동시에 단선되는 것은 고려하고 있지 않다. 이에 본 연구는 발생 가능한 모든 단선의 경우에 대해서 보요소를 적용한 유한요소해석을 실시하여 극한상태를 파악하고 국내 설계기준에 따른 안전성를 평가하였다. 유한요소해석 결과분석을 통해 철탑 주주재에는 이상시 휨응력의 영향력이 매우 크게 나타났으며, 비대칭 일측의 모든 전선이 단선된 경우 기존 철탑의 설계방법이 안전하지 않음을 알 수 있었다. 따라서 이상시 철탑의 경제성과 정확한 안전성 확보를 위해 부재의 극한상태와 이상시 발생빈도를 고려하는 설계법의 적용이 필요할 것으로 판단된다.

영상 분석 기법을 이용한 RC 부재의 항복 후 휨 거동 분석(II): 인장부를 중심으로 (Evaluation on the Bending Behavior After Yield of RC Beam by Using Image Processing Method(II): Focused on the Tensile Part)

  • 김건수;박기태;우태련
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권6호
    • /
    • pp.47-53
    • /
    • 2022
  • 콘크리트구조물의 한계상태설계법이 적용되면서 구조물의 극한상태까지 고려하는 설계가 이루어지고 있다. 실제 철근콘크리트 부재가 인장력을 부담할 때 부재가 항복한 후에도 극한상태까지 콘크리트가 인장력을 부담한다. 따라서 한계상태 거동에 대한 정확한 평가를 위해서는 휨 부재의 항복 후 인장강화효과에 대한 연구가 필요하다. 본 연구에서는 복철근 직사각형 단면을 가지는 RC 단순보에 대하여 4점 휨 실험을 수행하였고, 영상분석기법을 이용하여 부재의 거동을 상세하게 분석하였다. 분석 결과를 이용하여 휨 인장강화효과 계수를 도입한 항복 후 인장강화효과 추정식을 제안하였고, 이를 기존 연구들의 실험 결과를 통해 적용성을 검증하였다. 부재의 연성거동을 대표하는 극한 변형률과 항복 변형률 차이가 실험 결과와 유사하게 나타나 제안식의 예측이 비교적 정확한 것으로 판단된다.