• Title/Summary/Keyword: Cross-Tension

Search Result 248, Processing Time 0.032 seconds

Hydrodynamic Motion and Structural Performance of Concrete Floating Structure by Length Using Numerical Analysis (수치해석을 통한 콘크리트 부유구조체 길이에 따른 운동 및 구조성능 검토)

  • Lee, Du-Ho;You, Young-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.4
    • /
    • pp.401-409
    • /
    • 2013
  • In the present study, numerical analysis was performed for hydrodynamic motion and structural performance on four different concrete floating structures, which have same cross-section but different length. The hydrodynamic analysis of floating structures is carried out using ANSYS AQWA with the different 34 wave load on regular wave period from three seconds to ten seconds in 35 m water depth. In order to evaluate structural performance of floating structures under the critical wave load which obtained from hydrodynamic analysis. The integrated analysis is also carried out through the mapping method, which can directly connect the wave-induced hydraulic pressure obtained form ANSYS AQWA to Finite Element Model in ANSYS Mechanical. As a results of this study, the hydrodynamic motion of floating structures is decreased as the length of structure increased. It means that the effect of wave-structure interaction is strongly dependent on the relationship between a wave period and a length of structure. Moreover, it is found that tension stress on bottom slab of floating structure is occurred by the critical wave load, the sectional force is not influenced by length of a structure.

Effects of Comfort Nursing Measures on Postoperative Recovery of Patient (안위대책 간호가 수술 후 회복에 미치는 영향)

  • 한윤복
    • Journal of Korean Academy of Nursing
    • /
    • v.3 no.1
    • /
    • pp.85-95
    • /
    • 1972
  • For the purpose to clarify the effects of nursing, intervention with comfort measures which promote rest, exercise and sleep on the patient′s rehabilitation, this study was carried out on 119 postoperative patients at St. Mary′s Hospital, the National Medical Center and Seoul Red Cross Hospital during the 9 months period from March 1971 to November 1971. In this study one experimental nursing approach was utilized; an emphasis on interpersonal techniques along with physical care-comfort measures. A daily evening care including support and instruction was given to facilitate interaction of nursing to the experimental group by the investigator. For the control group, routine hospital nursing care was performed. The nursing observation was followed for 4 days postoperatively and recorded in check list. The results of the findings were as follows. 1. 3.5% of control group and 32.3% of experimental group got out of bed within 24 hours postoperatively. 38.6% of control group got out of bed within 72 hours postoperatively where only 16.1% of the experimental group did (x$^2$= 19.865, p<0.005). Interaction in nursing is, in turn, significantly more effective than the usual routine care in improving rate of healing. 2. The irritations and tension that may interfere patient′s sleep and rest at night can be reduced to a minimum if nursing environment is better controlled with planned nursing care for individual patient. Various treatments which tend to give patient discomfort may preferably be performed before 6 p.m. if not absolutely indicated. 3. During 4 days of observation the patients without administration of sedatives and analgesics postoperatively were 25.9% in the experimental group where as 10.5% in the control group. The frequency of administration of sedatives and analgesics in average was 1.4 in the experimental group, and 2.0 in the control group. This indicates that not all postoperative discomforts expressed by the patients should be regarded as incision pain, and those discomforts could be relieved to a certain extent by nursing interventions effectively. 4. There were significant differences between the responses to nursing care given in the experimental group and 33% of the control group in average through 4 days of observation responded "good". 3.6% of the experimental group and 17. 1% of the control group responded "poor" in this study. It was recommended that the study be replicated in a more defined and controlled manner. Some alternative areas for investigation were suggested.

  • PDF

Finite Element Analysis on the Behavior of Soyanggang Dam and its Comparison with Observed (소양강(昭陽江)댐의 거동(擧動)에 대한 유한요소해석(有限要素解析)과 실측치(實測値)와의 비교(比較))

  • Kim, Sang Kyu;Lim, Heui Dae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.141-150
    • /
    • 1987
  • The Soyanggang Dam completed in 1973 was well instrumented during construction period. The measured results for stresses and movements of the embankment have already been published elsewhere, but theoretical analyses have not been made until now. This study intends to analyze the stress and deformation behavior of the embankment numerically which have been subjected to the load of materials during construction and water load during impounding. The constitutive law used for the analyses is hyperbolic model developed by Duncan et al., and a nonlinear incremental finite element analysis simulating its contruction steps is. used in this study. Hyperbolic parameters for each Zone are estimated from literature. The results obtained from the theoretical analyses clearly show deformation characteristics and stress vectors in arbitrary section of the dam. The analytical results ate well agreed with the measured deformations at the maximum cross section, however, there are some discrepancy in horizontal movements and in stresses generated in the core zone. From the numerical analyses and its comparison with the measured values, it is charaterized that relatively large construction settlements occurred in core zone, overburden pressure in the core zone was considerably reduced by arching effect, and tension zones might occur near both abutments because of the large horizontal displacement.

  • PDF

Bioequivalence of Tofim Tablet to Grandaxin Tablet (Tofisopam 50 mg) (그란닥신 정(토피소팜 50 mg)에 대한 토핌 정의 생물학적 동등성)

  • Cho, Hea-Young;Jeong, Hyun-Cheol;Her, Su-Hi;Lim, Dong-Gu;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.2
    • /
    • pp.131-136
    • /
    • 2001
  • Tofisopam is a new type of tranquilizer valuable for the relief of anxiety and tension in a wide range of emotional disorders. Tofisopam has the therapeutic characteristics of a minor tranquilzer and a mild stimulatory effect. The purpose of the present study was to evaluate the bioequivalence of two tofisopam tablets, $Grandaxin^{TM}$ (Hwan In Pharmaceutical Co., Ltd.) and $Tofim^{TM}$ (Kyung Dong Pharmaceutical Co., Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). Eighteen normal male volunteers, $23.11\;{\pm}\;2.83$ years in age and $65.43\;{\pm}\;7.64\;kg$ in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After one tablet containing 50 mg of tofisopam was orally administered, blood was taken at predetermined time intervals and the concentrations of tofisopam in serum were determined using HPLC method with UV detector. The pharmacokinetic parameters such as $AUC_t$, $C_{max}\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters. The results showed that the differences in $AUC_t$, C_{max}\;and\;T_{max}$ between two tablets based on the $Grandaxin^{TM}$ were -5.59%, 2.22% and -13.18%, respectively. Minimum detectable differences $({\Delta})$ at ${\alpha}=0.10$ and $1-{\beta}=0.8$ were less than 20% (e.g., 14.95% and 19.34% for $AUC_t\;and\;C_{max}$, respectively). The powers $(1-{\beta})$ at ${\alpha}=0.10$, ${\Delta}=0.2$ for $AUC_t$ and $C_{max}$ were 95.21% and 81.93%, respectively. The 90% confidence intervals were within {\pm}20%$ (e.g., $-15.64{\sim}4.45$ and $-10.77{\sim}15.21$ for $AUC_t\;and\;C_{max}$, respectively). Two parameters met the criteria of KFDA for bioequivalence, indicating that $Tofim^{TM}$ tablet is bioequivalent to $Grandaxin^{TM}$ tablet.

  • PDF

Effect of Recovery of Pulmonary Function in Hypothermic Lung Preservation (肺의 低溫保存法이 肺機能 回復에 미치는 영향)

  • Lee, Man Bok;Kim, U Jong;Gang, Chang Hui;Lee, Gil No
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.253-253
    • /
    • 1997
  • Hypothermia during lung preservation decreases metabolic processes. After the rabbit lung was flushed with modified Euro-Collins solution, heart-lung block was harvested and the left lung was assessed after ligation of the right pulmonary artery and right main-stem bronchus. Heart-lung block was immersed in the same solution for 6 hours. The modified Euro-Collins solution and storage temperature of group 1(10 cases) was 4t, roup 2(10 cases) was l0℃. On completion of the storage period, the left lung was ventilated and reperfused with blood u:high used a cross-circulating paracorporeal rabbit as a "biologic deoxygenator" for 60 minutes. Pulmonary artery pressure, airway pressure, difference in oxygen tension between mow and outflow perfusate and degree of pulmonary edema were assessed at 10-minute intervals while the left lung was ventilated at 0.8 of the inspired oxygen fraction. The mean pulmonary venous oxygen tensions at 10 and 60 minutes after reperfusion were 209.52±42.46 and 103.48± 15.96 mmHg in group I versus 247.78±36.19 and 147.91 ± 11.07 mmHg in group II(p=0.049, (0.0001). The mean alveolar-arterial oxygen differences at 20 and 60 minutes after reperfusion were 357. 95± 12.84 and 437.31 14.26 mmHg in group I versus 310.88±3).47 and )90.93± 15.86 mmHg in group II (p=0.0092, (0.0001). The mean pulmonary arterial pressures at 10 and 60 minutes after reperfusion were 40.56± 18.66 and 87. 2± 17.22 mmHg in group I versus 31.22±6.84 and 65.78± 11.02 mmHg in group rl (p : 0.048, 0.0062). The mean pulmonary vascular resistances at 10 and 60 minutes after reperfusion were 2.69±0.85 and 4.36±0.86 mmHg/ml/min in group I versus 1.99±0.39 and 3.29±0.55 mmHg/ml/min in group II(p : 0.0323, 0.0062). There were no difference between groups in peak airway pressure, lung compliance and degree of pulmonary edema. In conclusion that preservation of lung at l0℃ was superior to preservation at 4℃.

An Experimental Study on Flexural Behavior of Steel Fiber Reinforced Ultra High Performance Concrete Prestressed Girders (강섬유 보강 초고성능 콘크리트 프리스트레스트 거더의 휨거동 실험 연구)

  • Yang, In-Hwan;Joh, Chang-Bin;Kim, Byung-Suk
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.777-786
    • /
    • 2010
  • This paper examines the flexural behavior of full-scale prestressed concrete girders that were constructed of steel fiber reinforced ultra high performance concrete (UHPC). This study is designed to provide more information about the bending characteristics of UHPC girders in order to establish a reasonable prediction model for flexural resistance and deflection for future structural design codes. Short steel fibers have been introduced into prestressed concrete T-girders in order to study their effects under flexural loads. Round straight high strength steel fibers were used at volume fraction of 2%. The girders were cast using 150~190 MPa steel fiber reinforced UHPC and were designed to assess the ability of steel fiber reinforced UHPC to carry flexural loads in prestressed girders. The experimental results show that steel fiber reinforced UHPC enhances the cracking behavior and ductility of beams. Moreover, when ultimate failure did occur, the failure of girders composed of steel fiber reinforced UHPC was observed to be precipitated by the pullout of steel fibers that were bridging tension cracks in the concrete. Flexural failure of girders occurred when the UHPC at a particular cross section began to lose tensile capacity due to steel fiber pullout. In addition, it was determined that the level of prestressing force influenced the ultimate load capacity.

Research on Re-creational Experiment and Technique of Gold Powder Painting for Goryeo Gold-painted Porcelain (고려시대 금채자기의 채색기법 재현실험 연구)

  • Hwang, Hyun-Sung;Lee, Da-Hae
    • Journal of Conservation Science
    • /
    • v.27 no.4
    • /
    • pp.403-414
    • /
    • 2011
  • This study is re-creational experiment of Goryeo gold-painted decoration based on the research of the gold remaining and gold painting technique on the two pieces of Goryeo gold-painted celadon and the three pieces of Chinese gold-painted porcelain on North Song period which ones have been owned by National Museum of Korea since 2007. For the observation of glue state and color developing ability, four kinds of agglutinative agent and gold powder were mixed over the porcelain sherds, then gradually fired from $100^{\circ}C$ to $1200^{\circ}C$. Visual effect and ideal temperature were measured. Among of them, oil and glue showed the best results in glue state and color developing ability. Through those results, the entire Goryeo engraved celadon were reproduced in modern facilities. Oil and glue were gold-painted over the glaze then it was fired at the ideal temperature 700 to $800^{\circ}C$. For observation the binding condition, the gold-painting cross section was looked by the scanning electron microscope (SEM). As the result, oil and glue did not make much difference in Agglutinative agent, but gold was good, the color developing ability, however, in the case of oil, the edge of gold is curled because of its interfacial tension, and it is not dried well at room temperature so the working property is not as good as the glue. Glue more effective in terms of work efficiency, but color developing ability to fall slightly in this experiment were able to see through.

A Study on High Speed Laser Welding by using Scanner and Industrial Robot (스캐너와 산업용 로봇을 이용한 고속 레이저 용접에 관한 연구)

  • Kang, Hee-Shin;Suh, Jeong;Kim, Jong-Su;Kim, Jeng-O;Cho, Taik-Dong
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.29-29
    • /
    • 2009
  • On this research, laser welding technology for manufacturing automobile body is studied. Laser welding technology is one of the important technologies used in the manufacturing of lighter, safer automotive bodies at a high level of productivity; the leading automotive manufacturers have replaced spot welding with laser welding in the process of car body assembly. Korean auto manufacturers are developing and applying the laser welding technology using a high output power Nd:YAG laser and a 6-axes industrial robot. On the other hand, the robot-based remote laser welding system was equipped with a long focal laser scanner system in robotic end effect. Laser system, robot system, and scanner system are used for realizing the high speed laser welding system. The remote laser welding system and industrial robotic system are used to consist of robot-based remote laser welding system. The robot-based remote laser welding system is flexible and able to improve laser welding speed compared with traditional welding as spot welding and laser welding. The robot-based remote laser systems used in this study were Trumpf's 4kW Nd:YAG laser (HL4006D) and IPG's 1.6kW Fiber laser (YLR-1600), while the robot systems were of ABB's IRB6400R (payload:120kg) and Hyundai Heavy Industry's HX130-02 (payload:130kg). In addition, a study of quality evaluation and monitoring technology for the remote laser welding was conducted. The welding joints of steel plate and steel plate coated with zinc were butt and lapped joints. The quality testing of the laser welding was conducted by observing the shape of the beads on the plate and the cross-section of the welded parts, analyzing the results of mechanical tension test, and monitoring the plasma intensity and temperature by using UV and IR detectors. Over the past years, Trumf's 4kW Nd:YAG laser and ABB's IRB6400R robot system was used. Nowadays, the new laser source, robot and laser scanner system are used to increase the processing speed and to improve the efficiency of processes. This paper proposes the robot-based remote laser welding system as a means of resolving the limited welding speed and accuracy of conventional laser welding systems.

  • PDF

Measurement of Distributed Temperature and Strain Using Raman OTDR with a Fiber Line Including Fiber Bragg Grating Sensors (광섬유 브래그 격자 센서가 있는 광섬유 라인에 라만 OTDR을 이용한 분포 온도 및 변형률 측정 가능성에 대한 연구)

  • Kwon, Il-Bum;Byeon, Jong-Hyun;Jeon, Min-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.443-450
    • /
    • 2016
  • In this study, we propose a novel fiber optic sensor to show the measurement feasibility of distributed temperature and strains in a single sensing fiber line. Distributed temperature can be measured using optical time domain reflectometry (OTDR) with a Raman anti-Stokes light in the sensing fiber line. Moreover, the strain can be measured by fiber Bragg gratings (FBGs) in the same sensing fiber line. The anti-Stokes Raman back-scattering lights from both ends of the sensing fiber, which consists of a 4 km single mode optical fiber, are acquired and inserted into a newly formulated equation to calculate the temperature. Furthermore, the center wavelengths from the FBGs in the sensing fiber are detected by an optical spectrum analyzer; these are converted to strain values. The initial wavelengths of the FBGs are selected to avoid a cross-talk with the wavelength of the Raman pulsed pump light. Wavelength shifts from a tension test were found to be 0.1 nm, 0.17 nm, 0.29 nm, and 0.00 nm, with corresponding strain values of $85.76{\mu}{\epsilon}$, $145.55{\mu}{\epsilon}$, $247.86{\mu}{\epsilon}$, and $0.00{\mu}{\epsilon}$, respectively. In addition, a 50 m portion of the sensing fiber from $30^{\circ}C$ to $70^{\circ}C$ at $10^{\circ}C$ intervals was used to measure the distributed temperature. In all tests, the temperature measurement accuracy of the proposed sensor was less than $0.50^{\circ}C$.

Structural Performance of Pre-tensioned Half-depth Precast Panels (프리텐션 반두께 바닥판을 갖는 바닥판의 구조성능 평가)

  • Kim, Dong Wook;Shim, Chang Su
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1707-1721
    • /
    • 2014
  • Half-depth panels were developed with the merits of CIP (Cast In Place) decks and precast decks for constructability and fast construction. In this paper, details of half-depth panels with pre-tensioning were suggested. For evaluation of structural performance, five half-depth panel specimens were fabricated and static tests were conducted. The cross-sections of these specimens were composed of pre-tensioned half-depth panels and pre-tensioned two-span half-depth panels. Test parameters were the amount of the prestressing force and the longitudinal reinforcements. Static tests on simply-supported slabs showed that ultimate strength was 1.55 times greater than calculated nominal strength. The flexural strength was only 10 % increased and the influence on crack width control was negligible when the member of tendons was increased twice. For two-span continuous specimens, the ultimate strength increased 1.2 times and 1.38 times respectively as the reinforcement was additionally provided. The verified half-depth panels by this research can be effectively utilized for the fast replacement or construction of bridges.