• 제목/요약/키워드: Cross tie detail

검색결과 8건 처리시간 0.023초

보강띠철근의 상세에 따른 중공 사각형 교각 압축부의 파괴 거동 (Behavior of Rectangular Hollow Bridge Compression Section by Detail of Cross-tie)

  • 이재훈;김호영;곽임종
    • 한국지진공학회논문집
    • /
    • 제21권1호
    • /
    • pp.21-29
    • /
    • 2017
  • Purpose of this study is to investigate structural behavior of the rectangular hollow column with various transverse reinforcement details. Experimental variables are diameter, arrangement details and lateral spacing of cross tie. A total of 66 column specimens have been prepared and tested under axial compressive load. Test results showed that behaviors of column specimens were different depending on the cross tie details. Specimens with cross tie wrapping longitudinal steel and transverse steel have greater strength and ductility than specimens with cross tie wrapping the longitudinal steel.

철근콘크리트 기둥에서 반복횡력에 대한 헤드형 횡보강근의 구속효과에 대한 실험연구 (Experimental Study on the Confinement Effect of Headed Cross Tie in RC Column Subjected to Cycling Horizontal Load)

  • 서수연;함주호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권5호
    • /
    • pp.1-10
    • /
    • 2012
  • 본 연구는 철근콘크리트 기둥 횡보강근의 형태 특히 크로스타이의 유무 및 단부 정착형태에 따른 내진성능을 평가하기 위한 실험연구이다. 계획된 실험변수인 크로스타이의 유무, 크로스타이의 단부 정착형태(헤드형 또는 갈고리형), 그리고 기둥 축응력의 크기에 따라 총 5개의 기둥 실험체를 제작한 뒤 일정 축력하에 횡방향 반복가력 실험을 수행한 후, 크로스타이가 철근콘크리트 기둥의 구조성능에 미치는 영향을 평가하였다. 실험으로부터, 크로스타이가 없이 띠철근만으로 횡보강된 기둥은, 낮은 횡력에서 균열과 함께 띠철근이 휨변형한 뒤 코아 콘크리트가 탈락되는 파괴양상을 보인 반면에 크로스타이가 있는 기둥은 균열이 발생한 이후에도 띠철근이 휨변형과 주근좌굴을 억제하고 코아 콘크리트를 효과적으로 구속하여 내력 및 연성을 증진시키는 것으로 나타났다. 횡방향 대변형시, 갈고리형 크로스타이는 $90^{\circ}$ 갈고리 부분이 펴지면서 코아 콘크리트가 탈락되는 양상을 보이지만 헤드형 크로스타이는 대변형 시에도 헤드가 매우 효과적으로 띠철근과 주근을 구속하여 높은 내력과 연성능력을 발휘하는 것으로 나타났다.

낮은 압축력을 받는 철근콘크리트 기둥의 내진성능에 대한 띠철근 상세의 영향 (Effects of Tie Details on Seismic Performance of RC Columns Subjected to Low Compression Loads)

  • 김철구;박홍근;엄태성;김태완
    • 한국지진공학회논문집
    • /
    • 제19권4호
    • /
    • pp.195-205
    • /
    • 2015
  • Various non-seismic tie details are frequently used for one- and two-story small buildings because the seismic demand on their deformation capacities is not relatively significant. To evaluate the effects of the non-seismic tie details on the seismic performance of reinforced concrete columns, six square columns with a cross section of $400{\times}400mm$ and six rectangular columns with a cross section of $250{\times}640mm$ were tested. The anchorage details at both ends and spacing of tie hoops, along with the cross-sectional shape and the magnitude of axial load, were considered as the primary test parameters. Test results showed that square columns had higher stiffness and lower lateral deformation rather than rectangular columns. Both lap spliced tie and U-shaped tie provided comparable or improved seismic performance to $90^{\circ}$ hook tie in terms of maximum strength, ductility, and energy dissipation. The predicted curves with modeling parameters in ASCE41-13 were conservative for test results of lap spliced tie and U-shaped tie specimens since plastic behavior after flexural yielding could not be considered. For economical design, ASCE41-13 should be revised with various test results of tie details.

철근콘크리트 기둥의 띠철근에서 135° 갈고리 대체 클립형 연결장치의 시공성 및 비용 분석 (Constructability and Cost Analysis of the Clip-Type Binding Implement Substituting 135° End-Hooked Transverse Reinforcement in Reinforced Concrete Columns)

  • 박경언;윤현도
    • 한국건축시공학회지
    • /
    • 제20권5호
    • /
    • pp.459-469
    • /
    • 2020
  • 이 연구의 목적은 철근콘크리트 기둥에서 띠철근 상세로 이용되는 갈고리 양단 135° 교차시공에 대해 동등이상의 구조적 성능을 확보하면서, 동시에 시공성을 개선할 목적으로 클립형 연결장치를 이용하여 90° 갈고리 띠철근에 결속하는 방법을 제시하였으며, 제안한 클립형 연결장치에 따른 시공성 평가 및 소요비용을 분석하였다. 분석 결과, 기둥 1개 전체 철근 조립하는 데 작업 시간은 클립형 연결장치 사용시 50%의 작업시간을 단축하는 것으로 나타났으며, 비용분석 결과 클립형 연결장치 1개 사용시 절감효과가 가장 효과적이었고, 표준 갈고리 상세 대비 약 32%의 비용 절감효과가 있는 것으로 분석되었다.

콘크리트 기둥과 철골 보 합성골조 접합부에서의 지압강도 (Bearing Strength of Concrete Column and Steel Beam Composite Joints)

  • 김병국;이원규;최완철
    • 콘크리트학회논문집
    • /
    • 제15권3호
    • /
    • pp.417-424
    • /
    • 2003
  • 철근콘크리트 기둥-철골보(RCS)합성골조 접합부에서 지압 거동을 평가하고 지압설계를 위하여 단순화한 국부지압 실험을 수행하였다. 편심하중에 의해 국부지압을 받을 때 콘크리트의 쐐기작용과 띠철근의 횡구속 효과에 의해 저항된다. 실험결과 U형 지압보강근은 지압내력을 철근 강도만큼 증가시키면서 상세와 설치가 단순하여 효과적으로 나타났다. 띠철근 양에 따라 지압강도가 증가하며 이중 띠철근이 더욱 효과적으로 약20% 증가된다. 현행 ASCE설계지침에서 띠철근 규정은 지압내력이 2 $f_{ck}$ 가 되기 위해서는 다소 미흡하며, 지압강도는 띠철근과 이중 띠철근을 증가시킴에 따라 최대한 2.5 $f_{ck}$ 까지 사용할 수 있다. 본 연구의 결과로서 RCS 보기둥 접합부의 지압내력 추정을 위한 예측식이 제안되었으며 실험결과와 비교적 잘 일치되고 있다.

Free vibrations of a two-cable network inter-supported by cross-links extended to ground

  • Zhou, H.J.;Wu, Y.H.;Li, L.X.;Sun, L.M.;Xing, F.
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.653-667
    • /
    • 2019
  • Using cross-ties to connect cables together when forming a cable network is regarded as an efficient method of mitigating cable vibrations. Cross-ties have been extended and fixed on bridge decks or towers in some engineering applications. However, the dynamics of this kind of system need to be further studied, and the effects of extending cross-links to bridge decks/towers on the modal response of the system should be assessed in detail. In this paper, a system of two cables connected by an inter-supported cross-link with another lower cross-link extended to the ground is proposed and analyzed. The characteristic equation of the system is derived, and some limiting solutions in closed form of the system are derived. Roots of cable system with special configurations are also discussed, attention being given to the case when the two cables are identical. A predictable mode behavior was found when the stiffness of inter-connection cross-link and the cross-link extended to the ground were the same. The vector of mode energy distribution and the degree of mode localization index are proposed so as to distinguish global and local modes. The change of mode behaviors is further discussed in the case when the two cables are not identical. Effects of cross-link stiffness, cross-link location, mass-tension ratio, cable length ratio and frequency ratio on $1^{st}$ mode frequency and mode shape are addressed.

Shaking table tests on seismic response of backdrop metal ceilings

  • Zhou, Tie G.;Wei, Shuai S.;Zhao, Xiang;Ma, Le W.;Yuan, Yi M.;Luo, Zheng
    • Steel and Composite Structures
    • /
    • 제32권6호
    • /
    • pp.807-819
    • /
    • 2019
  • In recent earthquakes, the failure of ceiling systems has been one of the most widely reported damage and the major cause of functionality interruption in some buildings. In an effort to mitigate this damage, some scholars have studied a series of ceiling systems including plaster ceilings and mineral wool ceilings. But few studies have involved the backdrop metal ceiling used in some important constructions with higher rigidity and frequency such as the main control area of nuclear power plants. Therefore, in order to evaluate its seismic performance, a full-scale backdrop metal ceiling system, including steel runners and metal panels, was designed, fabricated and installed in a steel frame in this study. And the backdrop metal ceiling system with two perimeter attachments variants was tested: (i) the ends of the runners were connected with the angle steel to form an effective lateral constraint around the backdrop metal ceiling, (ii) the perimeter attachments of the main runner were retained, but the perimeter attachments of the cross runner were removed. In the experiments, different damage of the backdrop metal ceiling system was observed in detail under various earthquakes. Results showed that the backdrop metal ceiling had good integrity and excellent seismic performance. And the perimeter attachments of the cross runner had an adverse effect on the seismic performance of the backdrop metal ceiling under earthquakes. Meanwhile, a series of seismic construction measures and several suggestions that need to be paid attention were proposed in the text so that the backdrop metal ceiling can be better applied in the main control area of nuclear power plants and other important engineering projects.

클립형 연결장치로 결속된 90도 갈고리를 갖는 띠철근의 정착거동 (Clip-type Binding Implement Effect on Anchorage Behavior of 90-Degree End-Hooked Transverse Reinforcement in Reinforced Concrete Columns)

  • 박경언;윤현도
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권4호
    • /
    • pp.72-80
    • /
    • 2020
  • 이 연구의 목적은 철근콘크리트 기둥에서 외부띠철근 상세로 이용되는 갈고리 양단 135도 교차 시공 상세에 대해, 대등한 구조적 성능을 확보하면서, 동시에 시공성을 개선할 목적으로 클립형 연결장치로 띠철근 갈고리 보강하는 방법을 제시하였다. 제안한 클립형 연결장치로 결속한 띠철근의 정착거동 및 강도를 파악하기 위해 콘크리트 압축강도, 클립형 연결장치의 묻힘길이, 설치 위치를 주요 변수로 28개 인발 실험체를 제작하여 실험하였다. 실험결과, 정착강도는 콘크리트 압축강도, 띠철근 직경, 클립의 묻힘길이, 설치 위치에 관계없이 클립형 연결장치로 결속하는 경우, 표준 갈고리 상세보다 모두 높게 나타났고 표준 갈고리 상세의 정착거동과 유사한 거동을 보여주었다. 그러므로, 90도 갈고리에 클립형 연결장치로 결속하는 상세는 표준 갈고리 상세와 대등한 정착거동 및 성능을 발휘할 수 있는 것으로 평가할 수 있다.