• Title/Summary/Keyword: Cross current

Search Result 1,723, Processing Time 0.052 seconds

Coreless Hall Current Sensor for Automotive Inverters Decoupling Cross-coupled Field

  • Kim, Ho-Gi;Kang, Gu-Bae;Nam, Dong-Jin
    • Journal of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.68-73
    • /
    • 2009
  • Automotive inverters may require current sensors for motor torque control, especially, in applications of hybrid electric vehicles or fuel cell vehicles. In this paper, to achieve a compact, integrated and low cost current sensor, a hall current sensor without magnetic core is introduced for integrating an automotive inverter. The compactness of the current sensor is possible by using integrated magnetic concentrators based on the Hall effect. Magnetic fields caused by three-phase currents are analyzed and a magnetic shield design is proposed for decoupling the cross-coupled field. It offers galvanic isolation, wide bandwidth (>100kHz), and accuracy(< 1%). Using 2D FEM analysis, its performance is demonstrated with design parameters at a U-shaped magnetic shield. The proposed coreless current sensor is tested with rated current to validate the linearity and accuracy.

A Study on unperfected circuiting current of undergrounded cable (지중송전케이블의 불완전 순환전류에 관한 연구)

  • Lee, Kwan-Woo;Lee, Yong-Sung;Kim, Bo-Kyeng;Park, Bok-Ki;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.3-6
    • /
    • 2004
  • In this paper, we studied on permissible current of unperfected earthing for cross-bond system. The factors of unperfected earth were jacket damage, cross-bonding mistake, arrestor damage, effect of other circuit but we only studied permissible current of arrestor or jacket damage. In the result, we earned that permissible current of normal 154[[kV]] CV $1C{\times}400SQMM$ cable is 760[A] but current of unperfected earthing cable is 76[A], unperfected earthing confirmed that accident of underground cable could occur. So, we could confirmed that Earthing resistance of unperfected earthing need to limit.

  • PDF

Characteristic of Optical Current Sensors Output by Sensor design (센서 형태에 따른 광전류센서의 출력 특성)

  • Kim, Young-Min;Park, Jung-Hwan;Lee, Kwang-Sik;Kim, Jung-Bae;Park, Won-Zoo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.342-345
    • /
    • 2007
  • 본 연구에서는 광섬유형(Fiber Optic Current Sensor) 광전류센서 구성 시 발생하는 선형복굴절(Linear Birefringence)의 보상에 용이한 수직원형틀(Orthogonal Loop Type) 센서헤드(Sensor Heads)를 개선하여 1 Cross 수직원형틀(l Cross Orthogonal Loop Type)을 제시하였다. 그리고 기존의 페루프형 원형틀 (Closed Loop Type), 수직원형틀 그리고 1 Cross 수직원형틀의 편광상태를 비교하였다. 그 결과 편광상태 측정 시 페루프 원형틀을 수직원형틀로 교체할 경우 15.3%, 1 Cross 수직원형틀로 교체할 경우 33.8%의 선형복굴절 감소 효과가 나타났다. 이에 1 Cross 수직원형틀을 광전류센서에 적용할 경우 안정된 편광특성으로 고신뢰성 광전류센서 개발 가능성을 높게 할 것이다.

  • PDF

Electrical Properties of Organic Materials as Low Dielectric Constant Materials

  • Oh Teresa;Kim Hong Bae;Kwon Hak Yong;Son Jae Gu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.3 s.12
    • /
    • pp.5-9
    • /
    • 2005
  • The bonding structure of organic materials such as fluorinated amorphous carbon films was classified into two types due to the chemical shifts. The electrical properties of fluorinated amorphous carbon films also showed very different effect of two types notwithstanding a very little difference. Fluorinated amorphous carbon films with the cross-link break-age structure existed large leakage current resulting from effect of the electron tunneling. Increasing the cation due to the electron-deficient group increased the barrier height of the films with the cross-link amorphous structure, therefore the electric characteristic of the final materials with low dielectric constant was also improved. The lowest dielectric constant is 2.3 at the sample with the cross-link amorphous structure.

  • PDF

A Study on the Spot Weldability of Automotive Steel Sheets (자동차용 도금강판의 점용접성에 관한 연구)

  • 민준기;오영근;김광수
    • Journal of Welding and Joining
    • /
    • v.14 no.3
    • /
    • pp.41-47
    • /
    • 1996
  • The spot weldability of coated steels for automobile has been investigated. Coated steels of SPC-Zn DC, SPC Zn-Ni SC, SPC Zn-Ni DC, SPC Zn-Fe DC and OCCS were welded under different conditions of welding current, force and time. Coating thickness at the welded surface was reduced as increased welding current. Tensile shear strength(TSS) and cross tensile strength (CTS) were increased up to expulsion began, then dropped as increased current. Optimum conditions of welding force and time were different, however 200~250kgf and 15~20cycle were optimum for coated SPC (Steel Plate Cold). Weldability lobes were measured for each coated steel and they showed narrow range of working welding current. The organic composite coated steel (OCCS) had the highest current to get $\sqrt5{t}$ nugget size and narrowest working welding current range.

  • PDF

A Study on Cross-Cultural Validation of Web-Based User Information Satisfaction (Flow) Measurement Model (웹기반 정보시스템 이용자정보만족도(Flow) 측정모델의 교차문화 검증에 관한 연구)

  • Jung, Jin-Taek
    • Journal of Digital Convergence
    • /
    • v.6 no.2
    • /
    • pp.157-164
    • /
    • 2008
  • The current research utilized as its target population who are current users of web based information system in Korea. The research validated the dimensions by studying he constructs within the context of the web based information system user population. Correlation was found between Flow dimensions retained as components of a ross-Cultural Model. It was determined that these two dimensions-Intrinsic Interest and Control-are significant predictors of user success. The Cross-Cultural Model was validated, and it is therefore suggested as a basis for further study of user success indicators in he cross-cultural enterprise environment.

  • PDF

EMTP-analysis of Transposition Effects on Underground Transmission Cables (EMTP를 이용한 지중케이블의 도체 연가 영향 분석)

  • Ha, C.W.;Han, S.H.;Heo, H.D.;Lee, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.93-94
    • /
    • 2006
  • The sheath of a single-conductor cable for ac service acts as a secondary of a transformer, the current in the conductor induces a voltage in the sheath. When the sheaths of single-conductor cables are bonded to each other, as is common practice for multi-conductor cables, the induced voltage causes current to flow in the completed circuit. This current causes losses in the sheath. Various methods of bonding may be used for the purpose of minimizing sheath losses. In korea, sheath cross bonding system was employed for the prevention of sheath losses, the sheaths wire subjected to at voltages, and the bonding was designed to keep the magnitude of the induced voltages within small limits so as to prevent the possibility of sheath corrosion. But, sheath cross bonding system without transposition of cable can not achieve an exact balance of induced sheath voltages unless the cables are lain in trefoil. This paper describes a transposition system with sheath cross bonding using EMTP(Electromagnetic Transient Program). The transposition system with cross bonding can be extended to longer cable circuits for laid in flat as wall as trefoil by the methods described in this paper.

  • PDF

Efficiency of Marine Hydropower Farms Consisting of MultipleVertical Axis Cross-Flow Turbines

  • Georgescu, Andrei-Mugur;Georgescu, Sanda-Carmen;Cosoiu, Costin Ioan;Alboiu, Nicolae
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.150-160
    • /
    • 2011
  • This study focuses on the Achard turbine, a vertical axis, cross-flow, marine current turbine module. Similar modules can be superposed to form towers. A marine or river hydropower farm consists of a cluster of barges, each gathering several parallel rows of towers, running in stabilized current. Two-dimensional numerical modelling is performed in a horizontal cross-section of all towers, using FLUENT and COMSOL Multiphysics. Numerical models validation with experimental results is performed through the velocity distribution, depicted by Acoustic Doppler Velocimetry, in the wake of the middle turbine within a farm model. As long as the numerical flow in the wake fits the experiments, the numerical results for the power coefficient (turbine efficiency) are trustworthy. The overall farm efficiency, with respect to the spatial arrangement of the towers, was depicted by 2D modelling of the unsteady flow inside the farm, using COMSOL Multiphysics. Rows of overlapping parallel towers ensure the increase of global efficiency of the farm.

Standstill Identification of Magnetic Flux Saturation Model Including Cross-Saturation for Synchronous Motors (상호 포화를 포함한 자기저항 동기 전동기의 자속 포화 모델에 대한 정지 상태 추정 기법)

  • Woo, Tae-gyeom;Park, Sang-woo;Choi, Seung-Cheol;Yoon, Young-Doo;Lee, Hak-Jun;Hong, Chanook;Lee, Jeongjoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.5
    • /
    • pp.364-371
    • /
    • 2021
  • A magnetic flux saturation model of Synchronous Reluctance Motors (SynRMs) and a parameter estimation method are proposed at standstill. The proposed magnetic flux model includes the nonlinear relationship between the current and the magnetic flux for self-saturation and cross-saturation. Voltage is injected at standstill to estimate the magnetic flux saturation model. Voltages are injected into the d-axis and q-axis to obtain data on self-saturation. Subsequently, voltages are simultaneously injected into the d-q axis to obtain data on cross-saturation. On the basis of the measured current and the calculated magnetic flux, the parameters of the proposed model are estimated using the least square method (LSM). Simulation and experiment were performed on a 1.5-kW SynRM to verify the proposed method. The proposed model can be used to create a high-efficiency operation table, a sensorless algorithm, and a current controller to improve the control performance of a motor.

Characteristics of Electron Beam Extraction in Cold Cathode Type Large Cross-Sectional Pulsed Electron Beam Generator (냉음극형 대면적 펄스 전자빔 가속기의 빔인출 특성)

  • Woo, S.H.;Lee, K.S.;Lee, D.I.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1609-1611
    • /
    • 2001
  • A large cross-section pulsed electron beam generator of cold cathode type has been developed for industrial applications, for example, waste water cleaning, flue gas cleaning, and pasteurization etc. The operational principle is based on the emission of secondary electrons from cold cathode when ions in the plasma hit the cathode, which are accelerated toward exit window by the gradient of an electric potential. The conventional electron beam generators need an electron scanning beam because the small cross section thermal electron emitter is used. The electron beam of large cross-section pulsed electron beam generator do not need to be scanned over target material because the beam cross section is large by 300$cm^2$. We have fabricated the large cross-sectional pulsed electron beam generator with the peak energy of 200keV and beam diameter of 200mm and obtained the large area electron beam in the air. The electron beam current has been investigated as a function of accelerating voltage, glow discharge current, helium pressure, distance from the exit window and radial distribution in front of the exit window.

  • PDF