• 제목/요약/키워드: Cross current

검색결과 1,727건 처리시간 0.028초

국내 송전 케이블 시스 순환전류 실측 및 분석 (Measurement and Analysis of Sheath Circulating Current in Domestic Underground Transmission Cables)

  • 하체웅;김정년;이수길;김동욱;이종범;강지원
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권4호
    • /
    • pp.193-200
    • /
    • 2003
  • The use of underground transmission tables has continuously increased in densely inhabited urban and suburban area. Due to a increasing demand of underground cables, two or more circuits are installed in parallel for several kilometers. It, however, has not been realized that the sheath circulating current is generated in the system where a large number of cables are laid in the same route. In this paper, Author studied diversely the sheath circulating current on underground cables depending on the various length rate, the phase arrangement, and the grounding resistance of the sheath in the cross-bonded section. It was clear that very large circulating current is generated in cable systems due to unbalanced length rate and phase arrangement in the cross-bonded section.

Islanding Detection Method for Inverter-based Distributed Generation Systems using a Signal Cross-correlation Scheme

  • Bae, Byung-Yeol;Jeong, Jong-Kyou;Lee, Ji-Heon;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.762-768
    • /
    • 2010
  • This paper describes the development of a new islanding detection method for inverter-based distributed generation systems, which uses a signal cross-correlation scheme between the injected reactive current and the power frequency deviation. The proposed method injects 1% of the reactive current to the rated current which brings about a negligible degradation of the power quality. It discriminates the islanding state, when the calculated cross-correlation index is larger than 0.5. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software and experimental research with a hardware prototype. The proposed method can detect the islanding state without degrading the power quality at the point of common connection. Further study is required to overcome the cancellation of the injected reactive current from multiple distributed generation units interconnected with the utility grid.

교차판매(CROSS-SELL) 스코어링 모형 개발 (A Development of Cross-Sell Scoring Model)

  • 한상태;강현철;이성건;정요천
    • 응용통계연구
    • /
    • 제17권2호
    • /
    • pp.229-238
    • /
    • 2004
  • 기업의 입장에서 가장 중요한 이유 중 하나는 자사에 있는 많은 고객들 중 회사에 수익을 가져다 줄 수 있는 고객이 누구인가라는 문제이다. 이러한 문제에 대한 기업의 고객 관리 전략 중 하나가 ‘교차판매(cross-sell)’ 전략이다. 본 연구에서는 국내 A손해보험사의 고객 데이터베이스를 활용하여 데이터마이닝 모형 개발이 어떻게 진행되고 있는지 실제 프로젝트를 중심으로 설명하고자 한다. 특히, 본 연구에서 목표로 하고 있는 것은 기존의 자동차보험에 가입한 보험사 고객 중에서 장기보험 및 세부 보험(상해, 질병, 암, 화제 보험 등)에 추가로 가입하는 고객의 특성을 파악하기 위한 교차판매 스코어링 모형을 개발하는 것이다.

Cross Entropy 기반의 주파수 영역에서 스펙트럼 센싱 성능 개선 (An Improved Cross Entropy-Based Frequency-Domain Spectrum Sensing)

  • 타사미아;구준롱;장성진;김재명
    • 대한전자공학회논문지TC
    • /
    • 제48권3호
    • /
    • pp.50-59
    • /
    • 2011
  • 본 논문은 주파수 영역에서 과거와 현재에 센싱된 결과들의 관계를 이용한 스펙트럼 센싱기법을 제안하였다. 기존에 제안된 대부분의 스펙트럼 센싱기법은 해당 시간에 센싱된 우선사용자의 신호만을 다루고 있다. 해당 시간 이전의 우선사용자의 상태는 조건부확률을 사용하여 검출기의 신뢰성을 증가시킬 수 있다. 따라서, 본 논문은 이전 시간과 해당 시간의 스펙트럼 센싱 결과를 사용하는 cross entropy 기반의 스펙트럼 센싱기법을 제안하며 이를 통해 우선사용자 신호 검출 성능을 향상시키고 잡음에 강인한 성능을 가질 수 있다. 이전 시간에 검출된 신호가 잡음인 경우 cross entropy 기반의 스펙트럼 센싱 성능 감소는 기존의 entropy 기반의 센싱기법과 동일하게 된다. 이러한 문제를 해결하기 위해 본 논문에서는 보다 향상된 cross entropy 센싱기법을 제안하였다. 본 논문은 시뮬레이션을 통해 가장 최근에 제안된 주파수 영역에서의 entropy 기반 스펙트럼 센싱기법 보다 제안된 방법이 더 나은 성능을 보이는 것을 보였다.

A Cross-Cultural Investigation of Adults' Formation of Sense of Community through Environmental Autobiography

  • Kim, Wonpil
    • Architectural research
    • /
    • 제14권4호
    • /
    • pp.125-132
    • /
    • 2012
  • In contemporary Korean society, urban community environment is often associated with high-density and high-rise residences that make people's relationships superficial, instrumental and impersonal. Furthermore, urban community consistently interplays with neighboring residents and childhood emotional experience are influential on their unconscious images and attitude about their current neighborhood environment, while affecting the environmental attitude and the formation of community sense. Previous research found evidences that increased level of community sense is fostering more feeling of living in so-called "real neighborhood environment." This study aimed to cross-culturally examine what the respondents' emotional perception and their attitude were about the community environment in their childhood through environmental autobiography method and to examine the effects of the results on adults' formation of sense of community for their current community environment. Extensive literature review explored a few important theoretical framework which are closely related to sense of community (SOC) as a result of emotional experience: membership, influence, integration and fulfillment of needs, shared emotional connection and community satisfaction. Chi-square and GLM analysis revealed that there were no demographic, and socio-economic differences between two groups of Korean and US residents. Correlation analysis indicated that childhood emotional experience of Koreans and US citizens was statistically significant on sense of community for their current living community. Multi-regression analysis also found that the degree of influence were the main predictors for building strong sense of current community throughout a cross-cultural group. Furthermore, the relationship between various emotional experience of each factor in previous and current community environment were statistically significantly related. It is concluded that as the positive childhood experience of influence in their past community was going up, the level of sense of community for their current community was strengthened across their cross-cultural background.

일부 전류분류영역을 가짐으로서 최소 열손실을 갖는 초전도 전류도입선 (Minimum Heat Dissipation of HTS Current Lead Having Partial Current Sharing Region)

  • 설승윤;허광수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.131-136
    • /
    • 2001
  • In this paper, a high-temperature superconductor(HTS) current lead operating in current sharing mode is described. The minimum heat dissipation and the optimum safety factor(cross-sectional area) is obtained analytically for partial current sharing HTS leads. It is assumed that the current lead is in conduction cooled state, and the sheath material is the alloy of silver and gold. The reduced cross-sectional area results partial current sharing state, and consequently reduces conduction heat transfer, but the Joule heat generation is increased. The optimized HTS current lead is different from the conventional copper leads. In the copper leads, the minimum heat dissipation is obtained for the zero gradient of temperature at warm end. However, the temperature gradient at warm end is not zero when the HTS lead operates at minimum dissipation state.

  • PDF

PVP-기반 유기 절연막 형성과 OTFT 제작 (Formation of PVP- Based Organic Insulating Layers and Fabrication of OTFTs)

  • 장지근;서동균;임용규
    • 한국재료학회지
    • /
    • 제16권5호
    • /
    • pp.302-307
    • /
    • 2006
  • The formation and processing of organic insulators on the device performance have been studied in the fabrication of organic thin film transistors (OTFTs). The series of polyvinyls, poly-4-vinyl phenol(PVP) and polyvinyltoluene (PVT), were used as solutes and propylene glycol monomethyl ether acetate(PGMEA) as a solvent in the formation of organic insulators. The cross-linking of organic insulators was also attempted by adding the thermosetting material, poly (melamine-co-formaldehyde) as a hardener in the compound. The electrical characteristics measured in the metal-insulator-metal (MIM) structures showed that insulating properties of PVP layers were generally superior to those of PVT layers. Among the layers of PVP series: PVP(10 wt%) copolymer, 5 wt% cross-linked PVP(10 wt%), PVP(20 wt%) copolymer, 5 wt% cross-linked PVP(20 wt%) and 10 wt% cross-linked PVP(20 wt%), the 10 wt% cross-linked PVP(20 wt%) layer showed the lowest leakage current characteristics. Finally, inverted staggered OTFTs using the PVP(20 wt%) copolymer, 5 wt% cross-linked PVP(20 wt%) and 10 wt% cross-linked PVP(20 wt%) as gate insulators were fabricated on the polyether sulphone (PES) substrates. In our experiments, we could obtain the maximum field effect mobility of 0.31 $cm^2/Vs$ in the device from 5 wt% cross-linked PVP(20 wt%) and the highest on/off current ratio of $1.92{\times}10^5$ in the device from 10 wt% cross-linked PVP(20 wt%).

새로운 상호결합 이득증가형 적분기를 이용한 1.8V 200MHz대역 CMOS 전류모드 저역통과 능동필터 설계 (Design of A 1.8V 200MHz band CMOS Current-mode Lowpass Active Filter with A New Cross-coupled Gain-boosting Integrator)

  • 방준호
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1254-1259
    • /
    • 2008
  • A new CMOS current-mode integrator for low-voltage analog integrated circuit design is presented. The proposed current-mode integrator is based on cross-coupled gain-boosting topology. When it is compared with that of the typical current-mirror type current-mode integrator, the proposed current-mode integrator achieves high current gain and unity gain frequency with the same transistor size. As a application circuit of the proposed integrator, we designed the 1.8V 200MHz band current-mode lowpass filter. These are verified by Hspice simulation using $0.18{\mu}m$ CMOS technology.

Multiple Decoupling Current Control Strategies for LCL Type Grid-Connected Converters Based on Complex Vectors under Low Switching Frequencies

  • Liu, Haiyuan;Shi, Yang;Guo, Yinan;Wang, Yingjie;Wang, Wenchao
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.1034-1044
    • /
    • 2019
  • In medium-voltage and high-voltage high-power converters, the switching devices need to operate at a low switching frequency to reduce power loss and increase the power capacity. This increases the delay of the signal sampling and PWM. It also makes the cross-couplings of the d-q current components more severe. In addition, the LCL filter has three cross-coupling loops and is prone to resonance. In order to solve these problems, this paper establishes a complex vector model of an LCL type grid-connected converter. Based on this model, two multiple decoupling current control strategies with passive damping / notch damping are proposed for the LCL type grid-connected converter. The proposed strategies can effectively eliminate the cross-couplings of the converter, achieve independent control of the d-q current components, expand the stable region and suppress the resonance of the LCL filter. Simulation and experimental results verify the correctness of the theoretical analysis and the feasibility of the proposed strategies.

입방정질화붕소입자 전착지석에 의한 전해디버링 시스템 (Electrochemical Deburring System by the Electroplated CBN Wheel)

  • 최인휴
    • 대한기계학회논문집A
    • /
    • 제21권3호
    • /
    • pp.430-438
    • /
    • 1997
  • Deburring and edge finishing technology as the final process of machining operation is required for manufacturing of advanced precise conponents. But, deburring is considered as a difficult problem on going to the high efficient production and automation in the FMS. Removal of burr couldn't have a standard of its definition because of its various shapes, dimensions and properties and mostly depends on manual treatment. Especially, deburring for cross hole inside is very difficult owing to its shape passing through out perpendicular to a main hole. The electrochemical method is suggested as its solution in practical aspect. Therefore, electrochemical deburring technology needs to be developed for the high efficiency and automation of internal deburring in the cross hole. In this study, the new process in the eliminating burr inside cross hole, electrochemical deburring by the wheel electroplated with Cubic-Boron-Nitrade abrasives, is suggested. Its deburring mechanism is described and machining performances is investigated. Also, CBN electroplated wheel is designed and manufactured and then characteristics of electrochemical deburring are investigated through experiments. Overall electrochemical deburring performance against burr inside cross hole is examined in the various power sources such as peak current and direct current.