• Title/Summary/Keyword: Cross Mode

Search Result 711, Processing Time 0.035 seconds

A Study on the Reduction of Standby Power Consumption for Multiple Output Converters (다출력 컨버터의 대기전력 저감에 관한 연구)

  • Jung, Jee-Hoon;Choi, Jong-Moon;Kwon, Joong-Gi
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.433-440
    • /
    • 2007
  • Recently, the reduction of standby power consumption is significantly issued in electronic and electrical industry for the conservation of environment. In the case of a switched mode power supply (SMPS), it is demanded high efficiency at extremely low output power conditions by consumers. However, it is very different from high efficiency techniques at full load conditions. In addition, many SMPSs are designed as a multi-output circuit for various loads because of cost down. This circuit is difficult to implement both high efficiency and good cross regulation performance, simultaneously. In this paper, secondary side post regulator (SSPR), current mode control method, and power sequence control technique are proposed to reduce standby power consumption and to improve cross regulation performance of the multi-output SMPSs which consist of single or multiple converter. The proposed methods are analyzed by their operational principles and optimal designs verified by experimental results with 110[W] and 270[W] SMPSs.

Efficient Video Streaming Mechanism through a New Rate Adaptation Scheme (새로운 전송률 적응기법을 통한 효율적인 비디오 스트림 전송 메커니즘)

  • Lee, Sun-Hun;Chung, Kwang-Sue
    • Journal of Broadcast Engineering
    • /
    • v.14 no.1
    • /
    • pp.44-58
    • /
    • 2009
  • To provide efficient video streaming service over a wireless networks, the rate adaptation scheme should be applied at the low layer and the quality adaptation scheme should be considered at the high layer. In this paper, we propose a new cross-layer design which includes rate adaptation scheme at the MAC/PHY layers and quality control at the application layer. Proposed rate adaptation scheme improves the wireless channel utilization by transmitting the consecutive frames and selects optimal transmission mode by calculating the goodputs for each transmission mode. Based on selected transmission mode, the rate adaptation scheme calculates the rate limits and informs that to the application layer. Then the video streaming application utilizes this rate limits to adjust the quality of the video stream. Through performance evaluations, we prove that our cross-layer design improves the quality of the wireless video streaming service by means of the proposed rate adaptation scheme.

An experimental study of a circular cylinder's two-degree-of-freedom motion induced by vortex

  • Kim, Shin-Woong;Lee, Seung-Jae;Park, Cheol-Young;Kang, Donghoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.4
    • /
    • pp.330-343
    • /
    • 2016
  • This paper presents results of an experimental investigation of vortex-induced vibration (VIV) of a flexibly mounted and rigid cylinder with two-degrees-of-freedom with respect to varying ratio of in-line natural frequency to cross-flow natural frequency, $f^*$, at a fixed low mass ratio. Combined in-line and cross-flow motion was observed in a sub-critical Reynolds number range. Three-dimensional displacement meter and tension meter were used to measure dynamic responses of the model. To validate the results and the experiment system, x and y response amplitudes and ratio of oscillation frequency to cross-flow natural frequency were compared with other experimental results. It has been found that the higher harmonics, such as third and more vibration components, can occur on a certain part of steel catenary riser under a condition of dual resonance mode. In the present work, however, due to the limitation of a size of circulating water channel, the whole test of a whole configuration of the riser at an adequate scale for VIV phenomenon was not able to be conducted. Instead, we have modeled a rigid cylinder and assumed that the cylinder is a part of steel catenary riser where the higher harmonic motions could occur. Through the experiment, we have found that even though the cylinder was assumed to be rigid, the occurrence of the higher harmonic motions was observed in a small reduced velocity ($V_r$) range, where the influence of the in-line response is relatively large. The transition of the vortex shedding mode from one to another was examined by using time history of x and y directional displacement over all experimental cases. We also observed the influence of in-line restoring force power spectral density with $f^*$.

A Study on Evaluation Method for Piping Shell Mode Vibration (배관 Shell Mode 진동 평가방법에 대한 연구)

  • Chun, Chang-Bin;Park, Soo-Il;Chun, Hyong-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1285-1289
    • /
    • 2006
  • In a large diameter piping system, high frequency energy can produce excessive noise, high vibration, and failures of thermo-well, instrumentation, and attached small-bore piping. High frequency energy is generated by flow induced vibration like vortex shedding in orifices and valves. Once this energy is generated, amplification may occur from acoustical and/or structural resonances, resulting in high amplitude vibration and noise. At low frequencies, pipe vibration occurs laterally along the pipe's length, but at higher frequencies, the pipe shell wall vibrates radially across its cross-section. The simple beam analogy which is based on the beam mode vibration can not be applied to evaluate shell mode vibration. ASME OM3 recommends that the stress be measured directly by strain gauge and be evaluated according to the fatigue curves of the piping material. This Paper discusses the excitation and amplification mechanism relevant to high frequency energy generation in piping system, the monitoring method of the shell mode vibration in ASME OM3, the evaluation method generally used in the industry. Finally this paper presents the stress evaluation of the cavitating venturi down stream piping, where high frequency shell mode vibrations were observed during the operation.

  • PDF

Design and Test of an Experimental Optical Cross-Connect

  • Lee, Sung-Un;Seo, Wan-Seok
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.3
    • /
    • pp.336-341
    • /
    • 1998
  • We describe the architecture of an optical cross-connect (OXC) which is modular in structure and is able to be upgraded to a virtual wavelength path by adding wavelength converters. The additional feature of the OXC is the all-optical nature. It can be implemented with commercial components including mechanical optical switches. As a result of the test on the experimental OXC, it has been shown that 2.5 Gb/s signal can be transmitted via the OXC through 100 km length o an ordinary single mode fiber with 3 dB penalty.

  • PDF

ON HOMOGENEOUS SHEAR FLOWS WITH BOTTOM CROSS SECTION

  • S. LAVANYA;V. GANESH;G. VENKATA RAMANA REDDY
    • Journal of applied mathematics & informatics
    • /
    • v.41 no.5
    • /
    • pp.1071-1084
    • /
    • 2023
  • We consider inviscid, incompressible homogeneous shear flows of variable cross section known as extended Rayleigh problem. For this extended Rayleigh problem, we derived instability region which intersect with semi-circle instability region under some condition. Also we derived condition for stability, upper bound for amplification factor and growth rate of an unstable mode.

A Study on the Fatigue Crack Growth of Cracks in Mechanical Joints (기계적 체결부 균열의 피로균열성장에 관한 연구)

  • 허성필;양원호;정기현
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.1
    • /
    • pp.187-194
    • /
    • 2002
  • It has been reported that cracks in mechanical joints is generally under mixed-mode and there is critical inclined angle at which mode I stress intensity factor becomes maximum. The crack propagates in arbitrary direction and thus the prediction of crack growth path is needed to provide against crack propagation or examine safety. In order to evaluate the fatigue life of cracks in mechanical joints, horizontal crack normal to the applied load and located on minimum cross section is major concern but critical inclined crack must also be considered. In this paper mixed-mode fatigue crack growth test is performed far horizontal crack and critical inclined crack in mechanical joints. Fatigue crack growth path is predicted by maximum tangential stress criterion using stress intensity factor obtained from weight function method, and fatigue crack growth rates of horizontal and inclined crack are compared.

Recent Topics on Injection and Combustion in High Speed Flow (Keynote)

  • Tomioka, Sadatake
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.3-8
    • /
    • 2009
  • Wall flush mounted injector with various orifice shape and injection conditions, were examined to enhance jet penetration and mixing in supersonic cross flow, in view of application to air-breathing accelerator vehicle. Orifice shapes with high aspect ratio were found to preferable for better penetration in the cold flow, and in the reacting flow for scramjet-mode combustion conditions. However, the effectiveness of the high aspect ratio was diminished in the dual-mode combustion conditions. Supersonic injection was applied to the high aspect ratio orifice, and further increase in penetration was observed in the cold and reactive flow for scramjet-mode combustion conditions, however, mixing enhancement due to mixing layer / pseudo-shock wave system interaction was dominant in the dual-mode combustion conditions. Difficulty in attaining ignition in the case with the high aspect ratio orifice was encountered during the combustion tests.

  • PDF

Fabrication and Characteristics Analysis of Ti:LiNbO$_{3}$ Optical Waveguide (Ti:LiNbO$_{3}$ 광도파로 제작 및 특성분석)

  • 윤형도;김성구;이한영;윤대원
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.7
    • /
    • pp.109-116
    • /
    • 1998
  • In this work was produced and analyzed a z-cut Ti:LiNbO$_{3}$ optical waveguide which applies for various optical devices.A waveguide channel with a thickness 8 .mu.m and a length 66,000.mu.m and a mach-zehnder interferometer type waveguide were fabricated at a diffusion temperature 1050.deg. C for 6-8hours in a wet $O_{2}$ environment. The resulting Ti:LiNbO$_{3}$ optical waveguide was measured to have a Ti-strip thickness of 950.angs. and low loss. Surfaces and cross-sections of a fabricated waveguide were analysed. The mode pattern anaysis revealed that the waveguide showed a single mode at a 1550nm wavelength. The effective dimension of the waveguide was calculated by measuring a gaussian profile; Wx=10.95.mu. and Wy=9.14.mu.m. a propagation loss, of 0.50dB/cm for a TM mode and 0.45dB/cm for a TE mode, was low enough to be accepatable for optical devices.

  • PDF

Fabrication and characterization of SILO isolation structure (SILO 구조의 제작 방법과 소자 분리 특성)

  • Choi, Soo-Han;Jang, Tae-Kyong;Kim, Byeong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.328-331
    • /
    • 1988
  • Sealed Interface Local Oxidation (SILO) technology has been investigated using a nitride/oxide/nitride three-layered sandwich structure. P-type silicon substrate was either nitrided by rapid thermal processing, or silicon nitride was deposited by LPCVD method. A three-layered sandwich structure was patterned either by reactive ion etch (RIE) mode or by plasma mode. Sacrificial oxidation conditions were also varied. Physical characterization such as cross-section analysis of field oxide, and electrical characterization such as gate oxide integrity, junction leakage and transistor behavior were carried out. It was found that bird's beak was nearly zero or below 0.1um, and the junction leakages in plasma mode were low compared to devices of the same geometry patterned in RIE mode, and gate oxide integrity and transistor behavior were comparable. Conclusively, SILO process is compatible with conventional local oxidation process.

  • PDF