• 제목/요약/키워드: Cross Head Assembly

검색결과 5건 처리시간 0.019초

평면 2자유도 모델을 이용한 LMG 상에서 이동되는 Cross Head의 사행동 해석 (Analysis of the Snake Motion of a Machine Tool Cross Head Assembly Travelling on Parallel Linear Motion Guides Using a Planar 2-D.O.F. Model)

  • 최영휴;김성훈;정택수;장은성
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 추계학술대회(한국공작기계학회)
    • /
    • pp.111-116
    • /
    • 2001
  • In this paper, a simple 2 D.O.F. planar motion model is proposed in order to analyze the snake motion of a machining center cross head assembly, that is travelling on linear guide rails. In the proposed mathematical model, the friction between head and guide ways is neglected, and also the support structures including guide rails, rear- and side-panels of the machining center are assumed to be rigid. The equations of motion of the proposed model are derived and successfully solved to determine vibration responses of the head assembly due to some applied traction forces.

  • PDF

LM 가이드 상에서 건마찰 접촉을 하면서 운동하는 Cross Head의 사행동에 관한 연구 (A Study on the Snake Motion of a Machine Tool Cross-Head Moving with Dry Friction on LM Guides)

  • 최영휴
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.708-713
    • /
    • 2000
  • This paper reviews the concepts of the snake motion which can be often observed on the bodies moving along guide rails. A simple modelling is proposed in order to analyze the snake motion of the cross head assembly and force and moment equilibrium equations are established. It is determined the critical conditions at which snake motion just brings about. Some possible methods to reduce or prevent snake motion are discussed in detail.

  • PDF

A COMPARATIVE STUDY ON THE DISLODGING FORCE OF MAGNETIC ATTACHMENT TO THE DENTURE RESIN BY MAGNETIC DESIGN AND FIXING MATERIALS

  • Lee, Jung-Hwa;Lee, Jong-Hyuk;Cho, In-Ho
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.261-268
    • /
    • 2008
  • STATEMENT OF PROBLEM: Detachment of the magnetic assembly from the denture base has been a problem in magnetic overdenture patients. PURPOSE: The objectives of this study were to compare the dislodging force by the fixing materials and the designs of the magnetic assembly, and to compare the effect between the fixing materials and the designs of the magnetic assembly. MATERIAL AND METHODS: Two fixing materials, Jet denture repair $acrylic^{(R)}$ and Super-$Bond^{(R)}$ C&$B^{(R)}$ and two types of magnetic assembly designed with or without wing were used. Each magnetic assembly was fixed in the chamber of the denture base resin block ($Lucitone^{(R)}$199) with each fixing material respectively. These specimens were thermocycled 2,000 cycles in the water held at $4^{\circ}C$ and $60^{\circ}C$ with a dwell time of 1 min each time. Each specimen was seated in a testing jig and then a push-out test was performed with a universal testing machine at a cross head speed of 0.5 mm/min to measure the maximum dislodging forces. RESULTS: Comparing the fixing materials, Super-Bond C&$B^{(R)}$ showed superior dislodging force than Jet denture repair $acrylic^{(R)}$. Comparing the design of the magnetic assemblies, the wing design magnetic assembly showed better dislodging force. Combination of the Super-Bond C&$B^{(R)}$ as a fixing material and wing design magnetic assembly revealed a greatest dislodging force. The kind of fixing material was more influential than the type of magnetic assembly. CONCLUSION: The dislodging force of Super-Bond C&$B^{(R)}$ was significantly higher than Jet denture repair $acrylic^{(R)}$. And the dislodging force of magnetic assembly which have wing design was significantly higher than magnetic assembly which have no wing design.

카복실레이트계 시멘트의 접착력에 관한 비교 연구 (COMPARATIVE STUDIES OF THE ADHESIVE QUALITIES OF POLYCARBOXYLATE CEMENTS)

  • 이한무
    • 대한치과보철학회지
    • /
    • 제17권1호
    • /
    • pp.23-34
    • /
    • 1979
  • In this study, the adhesive strength of three commercial polycarboxylate cements to ten types of dental casting alloys, such as gold, palladium, silver, indium, copper, nickel, chromium, and human enamel and dentine were measured and compared with that of a conventional zinc phosphate cement. The $8.0mm{\times}3.0mm$ cylindrical alloy specimens were made by casting. The enamel specimens were prepared from the labial surface of human upper incisor, and the dentine specimens were prepared from the occulusal surface of the human molar respectively. Sound extracted human teeth, which had been kept in a fresh condition since, extraction, were mounted in a wax box with a cold-curing acrylic resin to expose the flattened area. The mounted teeth were then placed in a Specimen Cutter (Technicut) and were cut down under a water spray, and then the flat area on the all specimens were ground by hand with 400 and 600 grit wet silicone carbide paper. Two such specimens were then cemented together face-to-face with freshly mixed cement, and moderate finger pressure was applied to squeeze the cement to a thin and uniform film. All cemented specimens were then kept in a thermostatic humidor cabinet regulated at $23{\pm}2^{\circ}C.$ and more than 95 per cent relative humidity and tested after 24 hours and 1 week. Link chain was attached to each alloy specimen to reduce the rigidity of the jig assembly, and then all the specimens were mounted in the grips of the Instron Universal Testing Machine, and a tensile load was delivered to the adhering surface at a cross head speed of 0.20 mm/min. The loads to which the specimens were subjected were recorded on a chart moving at 0.50 mm/min. The adhesive strength was determined by measuring the load when the specimen separated from the cement block and by dividing the load by the area. The test was performed in a room at $23{\pm}2^{\circ}C.$ and $50{\pm}10$ per cent relative humidity. A minimum of five specimens were tested each material and those which deviated more than 15 per cent from the mean were discarded and new specimens prepared. From the experiments, the following results were obtained. 1) It was found that the adhesive strength of the polycarboxylate cement to all alloys tested was considerably greater than that of the zinc phosphate cement. 2) The adhesive strength of the polycarboxylate cements was superior to the non precious alloys, such as the copper, indium, nickel and chromium alloys, but it was inferior to the precious gold, silver and palladium alloys. 3) Surface treatment of the alloy was found to be an important factor in achieving adhesion. It appears that a polycarboxylate cement will adhere better to a smooth surface than to a rough one. This contrasts with zinc phosphate cements, where a rough helps mechanical interlocking. 4) The adhesion of the polycarboxylate cement with enamel was found superior to its adhesion with dentine.

  • PDF

자성 어태치먼트의 형태와 수에 따른 하악 임플란트 피개의치의 유지력에 대한 비교 연구 (A Comparative Study on the Retention of Implant Overdenture According to the Shape and the Number of Magnetic Attachment)

  • 서민지;이준석;조인호
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.169-181
    • /
    • 2008
  • 치과용 자석의 개선으로 자성 어태치먼트를 이용한 임플란트 피개의치의 사용이 늘고 있다. 또한 여러 형태의 자성 어태치먼트가 개발되어 임상 상황에 따라 적절히 선택하여 사용할 수 있게 되었다. 이에 시중에 판매되는 세 가지 형태의 임플란트용 자성 어태치먼트를 이용해 자성 어태치먼트의 형태와 임플란트 수에 따른 임플란트 피개의치의 유지력을 비교 분석하였다. 식립된 임플란트가 1개인 경우를 1군, 2개인 경우 2군, 4개인 경우를 3군으로 하였고, 자성 어태치먼트의 형태에 따라 flat type, cushion type, dome type으로 세분하였다. Instron으로 수직방향, 사선방향, 전후방향의 인장력을 가하여 자성 어태치먼트의 형태에 따른 유지력의 차이, 힘의 방향에 따른 유지력의 차이, 자성 어태치먼트의 수에 따른 유지력의 변화를 비교 분석하여 다음의 결과를 얻었다. 1) 임플란트의 수와 상관없이 수직력은 flat type이 가장 컸으며, 측방력은 dome type이 가장 작은 것으로 나타났다. 2) 임플란트가 1개일 때 flat type의 수직력이 전후방회전력보다 크게 나타났고, 임플란트가 2개일 때는 dome type과 flat type이, 임플란트가 4개일 때는 cushion type과 flat type에서 수직력이 전후방회전력보다 크게 나타났다. 3) 임플란트 수에 따른 유지력 측정결과, 자석의 형태에 상관없이 임플란트 수가 많을수록 유지력은 증가하였다. 이상의 결과로 볼 때, 큰 유지력이 필요한 환자에게는 flat type이, 유해한 수평력이 존재하는 환자에게는 dome type의 이용이 유리하고, 임플란트가 1개일 때 flat type, 2개일 때 dome type과 flat type, 임플란트가 4개일 때 cushion type과 flat type이 피개의치의 안정성이 더 좋은 것으로 나타났다. 또한 자성 어태치먼트의 형태에 상관없이 임플란트의 수가 증가할수록 더 큰 유지력을 나타냈다. 따라서 임플란트 피개의치 사용 시 적절한 유지력과 안정성을 얻기 위해서 임플란트의 수와 자성 어태치먼트 형태의 고려가 필요하다고 사료된다.