• Title/Summary/Keyword: Critical span

Search Result 256, Processing Time 0.022 seconds

Living Labs as boundary-spanners between Triple Helix actors

  • van Geenhuizen, Marina
    • Journal of Contemporary Eastern Asia
    • /
    • v.15 no.1
    • /
    • pp.78-97
    • /
    • 2016
  • Living labs are an increasingly popular methodology to enhance innovation. Living labs aim to span boundaries between different organizations, among others Triple helix actors, by acting as a network organization typically in a real-life environment to foster co-creation by user-groups. This paper presents critical factors of Living labs in boundary-spanning between Triple Helix actors. Derived from a mixed-method approach and applications in the healthcare sector, the three main critical factors turn out to be 1) an adequate user-group selection and involvement, specifically a rich interaction and absorption of its results, 2) a balanced involvement of all relevant actors, and 3) a sufficient (early) attention for values, both values of user-groups and values of the management. People-oriented Living labs tend to differ from institution-oriented Living labs regarding these critical factors. Further, universities tend to take on diverse roles and strength of involvement, while the business sector tends to be actively involved only if this has been set as an explicit aim at start. The paper closes with a summary and future research paths.

A Study on the Equivalent Dynamic Stiffness of Bearing-pedestal (베어링 대의 등가 동강성에 관한 고찰)

  • Kim, Hee-Soo;Bae, Yong-Chae;Lee, Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.5 s.110
    • /
    • pp.452-456
    • /
    • 2006
  • The critical speeds and mode shapes are most important to determine the behaviors of rotor in designing rotating machinery. As the capacity and span of turbine-generator increases, the turbine-generator system is composed of many components such as bearings, pedestal, turbine and hood and so on. Also, it is getting flexible and has many critical speeds. Especially, as the characteristics of bearing-pedestal are very complicated, they affect the entire vibration characteristics of turbine-generator system. In this paper, it is observed how to determine the equivalent dynamic stiffness of bearing-pedestal by analytical and experimental method.

Wind Tunnel Testing of a Concrete Pylon for Long Span Cable-Stayed Bridge (장대 사장교 콘크리트 주탑의 풍동실험 연구)

  • 윤태양
    • Journal of KSNVE
    • /
    • v.4 no.2
    • /
    • pp.239-248
    • /
    • 1994
  • Wind tunnel tests and analyses of the response of the concrete pylon for the Seo Han Grand Bridge were conducted using aeroelastic model technique. A 1/250 scale aeroelastic model was used to measure the responses of the pylon at the several critical locations and to find any possible vibrational behavior. In order to confirm the model design and fabrication, natural frequencies and mode shapes measured from the model were compared with those from the calculation. Tests were conducted under the various angles ranging from $0^{\circ}$ to $90^{\circ}$ to find the critical angle of the wind. In order to evaluate the sensitivity of the response to changes in structural damping, a series of tests were conducted with two different values of structural damping such as 0.2% and 1.0% of critical. Additional tests were also conducted considering construction sequence.

  • PDF

A Study on the Equivalent Dynamic Stiffness of Bearing-Pedestal (베어링-페데스탈의 등가 강성에 관한 고찰)

  • Kim, Hee-Soo;Bae, Yong-Chae;Lee, Hyun;Lee, Dae-Seong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.263-266
    • /
    • 2005
  • The critical speeds and mode shapes are most important to determine the behaviors of rotor in designing rotating machinery. As the capacity and the span of turbine-generator increases, the turbine-generator system has many components such as bearings, pedestal, turbine and baseplates etc. and it is getting flexible and has many critical speeds. Especially, the characteristics of bearing-pedestal are very complicated and then they affect the entire vibration characteristics of turbine-generator system. In this paper, it is observed how to determine the equivalent dynamic stiffness of bearing-pedestal by analytic and experimental method.

  • PDF

Large deflections of variable-arc-length beams under uniform self weight: Analytical and experimental

  • Pulngern, Tawich;Halling, Marvin W.;Chucheepsakul, Somchai
    • Structural Engineering and Mechanics
    • /
    • v.19 no.4
    • /
    • pp.413-423
    • /
    • 2005
  • This paper presents the solution of large static deflection due to uniformly distributed self weight and the critical or maximum applied uniform loading that a simply supported beam with variable-arc-length can resist. Two analytical approaches are presented and validated experimentally. The first approach is a finite-element discretization of the span length based on the variational formulation, which gives the solution of large static sag deflections for the stable equilibrium case. The second approach is the shooting method based on an elastica theory formulation. This method gives the results of the stable and unstable equilibrium configurations, and the critical uniform loading. Experimental studies were conducted to complement the analytical results for the stable equilibrium case. The measured large static configurations are found to be in good agreement with the two analytical approaches, and the critical uniform self weight obtained experimentally also shows good correlation with the shooting method.

Chromatic Dispersion Compensation via Mid-span Spectral Inversion with Periodically Poled $LiNbO_3$ Wavelength Converter at Low Pump Power

  • Kim, Min-Su;Ahn, Joon-Tae;Kim, Jong-Bae;Ju, Jung-Jin;Lee, Myung-Hyun
    • ETRI Journal
    • /
    • v.27 no.3
    • /
    • pp.312-318
    • /
    • 2005
  • Mid-span spectral inversion (MSSI) has to utilize high optical pump power, for its operation principle is based on a nonlinear optical wavelength conversion. In this paper, a low pump-power operation of MSSI-based chromatic dispersion compensation (CDC) has been achieved successfully, for the first time to our knowledge, by introducing a noise pre-reduction scheme in cascaded wavelength conversions with periodically poled $LiNbO_3$ waveguides at a relatively low operation temperature. As preliminary studies, phase-matching properties and operation-temperature dependence of the wavelength converter (WC) were characterized. The WC pumped at 1549 nm exhibited a wide conversion bandwidth of 59 nm covering the entire C-band and a conversion efficiency of -23.6 dB at 11 dBm pump power. CDC experiments were implemented with 2.5 and 10 Gb/s transmission systems over 100 km single-mode fiber. Although it is well-known that the signal distortion due to chromatic dispersion is not critical at a 2.5 Gb/s transmission, the clear recovery of eye patterns was identified. At 10 Gb/s transmission experiments, eye patterns were retrieved distinctly from seriously distorted ones, and notable improvements in bit-error rates were acquired at a low pump power of 14 dBm.

  • PDF

Study on the Prestressing Effect of 3 Span Continuous Preflex Composite Beam of Bridges by Re-Up Down of Supports (지점 재 상승·하강에 의한 3경간 연속 프리플렉스 합성형의 프리스트레싱 효과에 관한 연구)

  • Koo, Min Se;Park, Young Je;Kim, Phil Sik
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.4
    • /
    • pp.433-441
    • /
    • 2001
  • Thus study presents the basic concepts of 3 span continuous preflex composite beam of bridges by re-up down of supports and analysis relationship of between variables and stress of critical section. Also, it shows the pre-compression effects of re-up down of supports method by presenting the difference of between old section and new section got from new method. This study's new method makes more economic sections to be possible and when the sections designed with the existing method are used in the new method. efficient stress state is accomplished.

  • PDF

Dynamic Characteristics of High-speed Railway Steel Bridges (고속철도 강교량의 진동특성 분석)

  • Lee, Jung-Whee;Kim, Sung-Il;Kwark, Jong-Won;Lee, Pil-Goo;Yoon, Tae-Yang
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.7 s.124
    • /
    • pp.632-637
    • /
    • 2007
  • The dynamic behavior of two steel bridges crossed by the Korean High Speed Train(KHST) has been investigated experimentally and the results are compared with the specification requirement of BRDM and other typical PSC Box bridge's responses. The investigated bridges are a 2-girder steel bridge of 1@40m span length(E-Won Bridge), 2@50m span length (Ji-Tan Bridge), and a PSC Box girder bridge of 2@40m span length (Yeon-Jae Bridge). A set of experimental tests were performed during operation of KHST, and a number of accelerometers, LVDTs and ring-type displacement transducers were utilized for measurement of three kinds of dynamic responses (acceleration, deflection, and end-rotation angle). Measured responses show that the vertical deflections and end-rotation angles of the three bridges are all satisfying the spec. requirement with large margin, but it was also found acceleration responses which are very close or exceed the limit value. Most of the excessive acceleration responses were found when the passing velocity of the KHST is close to the critical velocity ($V_{cr}$) which causes resonance. No noticeable differences of dynamic responses due to the different materials(steel or concrete) could be found within these experimental results.

Non-uniform wind environment in mountainous terrain and aerostatic stability of a bridge

  • Chen, Xingyu;Guo, Junjie;Tang, Haojun;Li, Yongle;Wang, Lei
    • Wind and Structures
    • /
    • v.30 no.6
    • /
    • pp.649-662
    • /
    • 2020
  • The existence of a dam has potential effects on the surrounding wind environment especially when it is located in mountainous areas. In this situation, the long-span bridge over the reservoir can easily be exposed to non-uniform incoming flows, affecting its wind-resistance performance. This paper presents a study on the aerostatic stability of such a bridge. Wind tunnel tests were first carried out to investigate the wind environment above a mountainous reservoir. The results show that the angle of attack and the wind speed along the bridge axis show obvious non-uniform characteristics, which is related to the inflow direction. When winds come from the south where the river is winding, the angle of attack varies along the span direction significantly. The finite element model for the bridge was established using ANSYS software, and effects of non-uniform wind loads on the aerostatic stability were computed. Non-uniform angle of attack and wind speed are unfavorable to the aerostatic stability of the bridge, especially the former. When the combined action of non-uniform angle of attack and wind speed is considered, the critical wind speed of aerostatic instability is further reduced. Moreover, the aerostatic stability of the bridge is closely related to the dam height.

A Study on the Modified Simple Truss Model to Predict the Punching Shear Strength of PSC Deck Slabs (PSC 바닥판의 뚫림전단강도 예측을 위한 단순트러스모델 개선 연구)

  • Park, Woo Jin;Hwang, Hoon Hee
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.67-73
    • /
    • 2015
  • In this paper, the simple truss model was modified to predict the punching shear strength of long-span prestressed concrete (PSC) deck slabs under wheel load including the effects of transverse prestressing and long span length between girders. The strength of the compressive zone arounding punching cone was evaluated by the stiffness of inclined strut which was modified by considering aging effective modulus. The stiffness of springs which control lateral displacement of the roller supports consists of the steel reinforcement and prestressing which passed through the punching cone. Initial angle of struts was determined by the experimental observation to compensate for uncertainties in the complexities of the punching shear. The validity of computed punching shear strength by modified simple truss model was shown by comparing with experimental results and the experimental results were also compared with existing punching shear equations to determine level of predictability. The modified simple truss model appeared to better predict the punching shear strength of PSC deck slabs than other available equations. The punching shear strength, which was determined by snap-through critical load of modified simple truss model, can be used effectively to examine punching shear strength of long span PSC deck slabs.