• 제목/요약/키워드: Critical heat flux

검색결과 296건 처리시간 0.026초

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

열변형으로 인한 틸팅패드 저널베어링의 예압 변화 (Thermal Deformation Induced Preload Changein the Tilting Pad Journal Bearing)

  • 서준호;황철호
    • Tribology and Lubricants
    • /
    • 제32권1호
    • /
    • pp.1-8
    • /
    • 2016
  • This paper focuses on the thermal deformation induced preload change in the tilting pad journal bearing, using a three-dimensional (3D) thermo-hydro-dynamic (THD) approach. Preload is considered as a critical factor in designing the tilting pad journal bearing. The initial preload measured under nil external load and nil thermal gradient is influenced by two factors, namely, the thermal deformation and elastic deformation. Thermal deformation is due to a temperature distribution in the bearing pads, whereas the elastic deformation is due to fluid forces acting on the pads. This study focuses on the changes induced in preload and film clearance due to thermal deformation. The generalized Reynolds equation is used to evaluate the force of the fluid and the 3D energy equation is used to calculate the temperature of the lubricant. The abovementioned equations are combined by establishing a relationship between viscosity and temperature. The heat transfer within the bearing pads, the lubricant, and the spinning journal is calculated using the heat flux boundary condition. The 3D Finite Element Method (FEM) is used in modeling the (1) heat conduction in the spinning journal and bearing pads, (2) thermal gradient induced thermal distortion of the spinning journal and pads, and (3) viscous shearing, and heat conduction and convection in a thin film. This evaluation method has an increased fidelity, and it can prove to be a cost-effective tool that can be used by designers to predict the dynamic behavior of a bearing.

고리 1호기에 대한 증기배관 파열사고 연구 (Study on the Steam Line Break Accident for Kori Unit-1)

  • Tae Woon Kim;Jung In Choi;Un Chul Lee;Ki In Han
    • Nuclear Engineering and Technology
    • /
    • 제14권4호
    • /
    • pp.186-195
    • /
    • 1982
  • SYSRAN code를 사용하여 고리 1호기의 중기배관파열사고를 분석하였다. SYSRAN code는 중성자출력과 열선속계산은 각각 점근사 중성자 운동방정식과 집중정수 모형을 이용하고 냉각수 계통 과도현상에 대해서는 전 계통을 균일한 압력으로 취급하여 질량 및 에너지 평형방정식을 이용하여 계산한다. 사고 결과를 심각하게 만드는 노심상태로 부냉각재 온도계수가 커지는 노심말기와 증기발생기의 유체함량이 가장 많은 고온 정지상태를 호기조건으로 하여, 격납용기외부의 가장 큰 배관면적인 1.4f $t^2$ 크기의 증기배관이 파열되었을때 Moody critical flow model에 따라 증기가 방출된다고 가정하여 분석하였다. 그 결과 노심의 최대 열선속은 사고후 60초에 정상상대의 38%로서 FSAR의 26%에 비해 높은 값을 나타냈으나 모든 과도현상의 경향은 FSAR의 결과와 잘 일치하였다. 민감도 조사결과 이 사고는 냉각재밀도 계수와 노심 하부공간혼합인자에 가장 민감한 것으로 나타났다. B bank중 한 개의 RCCA가 완전인출 상태에서 노심에 삽입되지 않았다고 가정했을 경우의 FSAR 분석결과인 $F_{$\Delta$H}$를 3.66으로 Fz를 1.55로 하여 DNBR을 계산해 본 결과, 최소 DNBR은 1.62가 되어 핵연료의 손상은 예상되지 않았다. 점근사중성자 운동방정식, 집중 정수모형 및 질량과 에너지평형 방정식을 이용한 계통 과도 현상모델은 발전소 전 계통의 과도 현상의 경향을 연구하는데 적합한 것으로 밝혀졌다.구하는데 적합한 것으로 밝혀졌다.

  • PDF

핵연료 수로내 난류 유동에 대한 횡방향 볼록구배의 영향 (Effect of Transverse Convex Curvature on Turbulent Fluid Flow in Fuel Channel)

  • Lee, Yung;Ahn, Seung-Hoon;Kim, Hyong-Chol
    • Nuclear Engineering and Technology
    • /
    • 제26권3호
    • /
    • pp.440-452
    • /
    • 1994
  • 핵연료 다발의 설계는 핵연료 표면에서의 열속이 임계열속에 도달되지 않도록 이루어져야한다. 이를 위해서는 설계된 핵연료 다발에 대한 임계열속이 정화하고 신뢰성 있게 평가되는 것이 매우 중요하다. 그러나 현재 사용되고 있는 임계열속 상관식에 관한 쟁점 대상중의 하나는 원통튜브관에서 실험적으로 얻어진 임계열속 자료가 유효직경 형태의 변수와 적당한 보정인자를 사용하여 핵연료다발 부수로 분석에 사용되고 있다는 것인데, 이러한 방법은 임계열속 예측에 있어서 불확실도 요인으로 작용하고 있다. 유효직경은 유동단면적상의 국부적 유체 특성을 제대로 표현하지 못 할 뿐만 아니라 표면구배효과 등을 고려할 수 없다. 더구나 난류유동은 오목구배면에서 보다는 볼록구배면에서 더욱 두드러진다. 즉, 횡방향 볼록구배면이 오목구배면 보다 유동의 반경방향으로의 난류 형성에 영향이 훨씬 크게 나타나는데, 이는 정화한 핵연료 임계열속 평가에 있어서 볼록구배의 영향이 반드시 고려되어야 함을 암시하는 것이다. 본 논문에서는 횡방향 구배의 유동영향에 대하여 전반적으로 심도있게 고찰하고 임계열속에 대한 영향이 논의 되었으며, 이 영향을 정량화하기 위하여 고려되어야 할 유동 모델과 향후 연구 방향이 제시되었다.

  • PDF

MOD-TFA공정에 의한 YBCO박막 제조 시 cerium첨가효과에 관한 연구 (Effect of Cerium Doping on Superconducting Properties of YBCO Film Prepared by TFA-MOD Method)

  • 이금영;권연경;김병주;안지현;이종범;김호진;이희균;홍계원;유재무;이형철
    • Progress in Superconductivity
    • /
    • 제8권1호
    • /
    • pp.87-92
    • /
    • 2006
  • The effects of Ba and Ce addition has been investigated in YBCO prepared by trifluoroacetate(TFA) metalorganic depostition(MOD) method. Precursor solutions with cation ratios of Y:Ba:Cu:Ce=1:2+x:3:x(x=0, 0.05, 0.1 and 1.5) have been prepared by adding an excess amount of cerium and barium. Coated film was calcined at lower temperature under a moisture-containing oxygen atmosphere. Superconducting YBCO films have been obtained by performing conversion heat treatment at temperature of $780{\sim}810^{\circ}C$ under a moisture-containing Ar(1,000 ppm oxygen) atmosphere. It has been shown that the critical current($I_c$) of YBCO film was degraded by doping of Ba and Ce atoms. But $I_c$ was increased as the amount of doped Ba and Ce content increased from 5% to 15 %. It was observed that there was little increase of a flux pinning force with Ba and Ce addition in YBCO film prepared by TFA-MOD process.

  • PDF

Enhanced critical current density of in situ processed MgB2 bulk superconductors with MgB4 additions

  • Kim, S.H.;Kang, W.N.;Jun, B.H.;Lee, Y.J.;Kim, C.J.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권1호
    • /
    • pp.36-41
    • /
    • 2017
  • The effects of $MgB_4$ addition on the superconducting properties and the microstructure of in situ processed $MgB_2$ bulk superconductors were studied. $MgB_4$ powder of 1-20 wt.% was mixed with (Mg + 2B) powder and then pressed into pellets. The pellets of (Mg + 2B + $xMgB_4$) were heat-treated at $650^{\circ}C$ for 1 h in flowing argon. The powder X-ray diffraction (XRD) analysis for the heat-treated samples showed that the major formed phase in all samples was $MgB_2$ and the minor phases were $MgB_4$ and MgO. The full width at half maximum (FWHM) values showed that the grain size of $MgB_2$ decreased as the amount of $MgB_4$ addition increased. $MgB_4$ particles included in a $MgB_2$ matrix is considered to suppress the grain growth of $MgB_2$. The onset temperatures ($T_{c,onset}$) of $MgB_2$ with $MgB_4$ addition (0-10 wt.%) was between 37-38 K. The 20 wt.% $MgB_4$ addition slightly reduced the $T_{c,onset}$ of $MgB_2$ to 36.5 K. This result indicates that $MgB_4$ addition did not influence the superconducting transition temperature ($T_c$) of $MgB_2$ significantly. On the other hand, the small additions of 1-5 wt.% $MgB_4$ increased the critical current density ($J_c$) of $MgB_2$. The $J_c$ enhancement by $MgB_4$ addition is attributed not only to the grain size refinement but also to the possible flux pinning of $MgB_4$ particles dispersed in a $MgB_2$ matrix.

마그네슘과 글리세린 처리한 붕소 분말로 합성한 Mg(B1-xCx)2의 초전도 특성 (Superconducting Properties of Mg(B1-xCx)2 Bulk Synthesized Using Magnesium and Glycerin-treated Boron Powder)

  • 김이정;전병혁;박순동;탄카이신;김봉구;손재민;김찬중
    • 한국분말재료학회지
    • /
    • 제15권3호
    • /
    • pp.182-187
    • /
    • 2008
  • Carbon was known to be one of effective additives which can improve the flux pinning of $MgB_2$ at high magnetic fields. In this study, glycerin $(C_3H_8O_3)$ was selected as a chemical carbon source for the improvement of critical current density of $MgB_2$. In order to replace some of boron atoms by carbon atoms, the boron powder was heat-treated with liquid glycerin. The glycerin-treated boron powder was mixed with an appropriate amount of magnesium powder to $MgB_2$ composition and the powder pallets were heat treated at $650^{\circ}C\;and\;900^{\circ}C$ for 30 min in a flowing argon gas. It was found that the superconducting transition temperature $(T_c)$ of $Mg(B_{1-x}C_x)_2$ prepared using glycerin-treated boron powder was 36.6 K, which is slightly smaller than $T_c$(37.1 K) of undoped $MgB_2$. The critical current density $(J_c)$ of $Mg(B_{1-x}C_x)_2$ was higher than that of undoped $MgB_2$ and the $T_c$ improvement effect was more remarkable at higher magnetic fields. The $T_c$, decrease and $J_c$ increase associated with the glycerin treatment for boron powder was explained in terms of the carbon substitution to boron site.

복합발전플랜트 내의 가스 화재 거동에 관한 수치해석 (Numerical Study of Fire Behavior Induced by Gas Leakage in Combined Cycle Power Plant)

  • 박재용;성건혁;이용남;최진욱;김대중;이성혁;유홍선
    • 한국분무공학회지
    • /
    • 제20권2호
    • /
    • pp.107-113
    • /
    • 2015
  • To date, the demand for Combined Cycle Power Plant (CCPP) has been continuously increased to overcome the problem of air pollution and lack of energy. In particular, the underground CCPP is exposed to substantial fire and explosion risks induced by gas leakage. The present study conducted numerical simulations to examine the fire behavior and gas leakage characteristics for a restricted region including gas turbine and other components used in a typical CCPP system. The commercial code of FLUENT V.14 was used for simulation. From the results, it was found that flammable limit distribution of leakage gas affects fire behavior. Especially, the flame is propagated in an instant in restricted region with LNG gas. In addition, consequence analysis factors such as critical temperature and radiation heat flux are introduced. These results would be useful in making the safety guidelines for the underground CCPP.

IMPLEMENTATION OF DATA ASSIMILATION METHODOLOGY FOR PHYSICAL MODEL UNCERTAINTY EVALUATION USING POST-CHF EXPERIMENTAL DATA

  • Heo, Jaeseok;Lee, Seung-Wook;Kim, Kyung Doo
    • Nuclear Engineering and Technology
    • /
    • 제46권5호
    • /
    • pp.619-632
    • /
    • 2014
  • The Best Estimate Plus Uncertainty (BEPU) method has been widely used to evaluate the uncertainty of a best-estimate thermal hydraulic system code against a figure of merit. This uncertainty is typically evaluated based on the physical model's uncertainties determined by expert judgment. This paper introduces the application of data assimilation methodology to determine the uncertainty bands of the physical models, e.g., the mean value and standard deviation of the parameters, based upon the statistical approach rather than expert judgment. Data assimilation suggests a mathematical methodology for the best estimate bias and the uncertainties of the physical models which optimize the system response following the calibration of model parameters and responses. The mathematical approaches include deterministic and probabilistic methods of data assimilation to solve both linear and nonlinear problems with the a posteriori distribution of parameters derived based on Bayes' theorem. The inverse problem was solved analytically to obtain the mean value and standard deviation of the parameters assuming Gaussian distributions for the parameters and responses, and a sampling method was utilized to illustrate the non-Gaussian a posteriori distributions of parameters. SPACE is used to demonstrate the data assimilation method by determining the bias and the uncertainty bands of the physical models employing Bennett's heated tube test data and Becker's post critical heat flux experimental data. Based on the results of the data assimilation process, the major sources of the modeling uncertainties were identified for further model development.

PREDICTIONS OF CRITICAL HEAT FLUX USING THE ASSERT-PV SUBCHANNEL CODE FOR A CANFLEX VARIANT BUNDLE

  • Onder, Ebru Nihan;Leung, Laurence Kim-Hung;Rao, Yanfei
    • Nuclear Engineering and Technology
    • /
    • 제41권7호
    • /
    • pp.969-978
    • /
    • 2009
  • The ASSERT-PV subchannel code developed by AECL has been applied as a design-assist tool to the advanced $CANDU^{(R)1}$ reactor fuel bundle. Based primarily on the $CANFLEX^{(R)2}$ fuel bundle, several geometry changes (such as element sizes and pitch-circle diameters of various element rings) were examined to optimize the dryout power and pressure-drop performances of the new fuel bundle. An experiment was performed to obtain dryout power measurements for verification of the ASSERT-PV code predictions. It was carried out using an electrically heated, Refrigerant-134a cooled, fuel bundle string simulator. The axial power profile of the simulator was uniform, while the radial power profile of the element rings was varied simulating profiles in bundles with various fuel compositions and burn-ups. Dryout power measurements are predicted closely using the ASSERT-PV code, particularly at low flows and low pressures, but are overpredicted at high flows and high pressures. The majority of data shows that dryout powers are underpredicted at low inlet-fluid temperatures but overpredicted at high inlet-fluid temperatures.