• Title/Summary/Keyword: Critical flow angle

Search Result 102, Processing Time 0.021 seconds

Structure and Characteristics of Diffusion Flame behind a Bluff-Body in a Divergent Flow(I) (확대유로내의 Bluff-Body 후류확산화염의 구조 및 특성 (1))

  • 최병륜;이중성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.5
    • /
    • pp.1269-1279
    • /
    • 1995
  • An experimental study is carried out on turbulent diffusion flames stabilized by a circular cylinder in a divergent duct flow. A commercial grade gaseous propane is injected from two slits on the rod as fuel. Flame stability limits, as well as size and temperrature of recirculation zone, are measured by direct and schlieren photographs to clarify the characteristics and structure of diffusion flames and to assess the effect of various divergent angle of duct. The results of the present study are as follows. Temperature in the recirculation zone decreases with increasing divergent angle. The blow-off velocity in parallel duct is higher than that in divergent duct. Critical blow-off velocity is expected to be about 8-12 degree through blow-off velocity pattern. Regardless of divergent angles, the length of recirculation zone is nearly constant, and this length becomes longer with rod diameter. Pressure gradient has an effect on the eddy structure in shear layer behind the rod. With the increase of divergent angle, large scale eddies by dissipated energy in shear layer are split into small scale eddies, and the flame becomes a typical distributedreacting flame.

A Study on the Standardization of Test Method of Flat-Plate Liquid-heating Solar Collectors (액체식 평판형 태양열 집열기 성능 실험의 표준화에 관한 연구)

  • 윤석범
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.3
    • /
    • pp.27-32
    • /
    • 1990
  • Standardization of solar collector test method is desirable for improvement solar collector quality and Valuation of collector thermal performance. In the present work, test loop proposed by Chun, is modified for convenience of test and obtained accurate collector thermal performance. An experimental investigation hat been carried out with a modified collector test loop under a real sun condition in order to confirm the utility of modified test loop and study the effect of variation of flow rate on thermal efficiency, the range of optimum flow rate and critical incident angle.

  • PDF

Transient stability analysis of the Yongwol.Bupyong power system by electronic analog computer techniques (상이형전자계산기에 의한 영월.부평간 송전계통의 과도안전도 해석)

  • 한만춘
    • 전기의세계
    • /
    • v.15 no.1
    • /
    • pp.14-19
    • /
    • 1966
  • Transient stability analysis of Yongwol-Bupyong power system, which contains Yongwol steam power station, the largest one in Korea, was undertaken by using the Yonsei 101 Analog computer. The critical switching time and phase angle for the present 150MW power flow to be stable were found. And the transient stability power limit for the system was also found. It is concluded that the system becoms unstable if the power flow increases much more than 151MW.

  • PDF

Single Bubble Dynamic Behavior in AL2O3/H2O Nanofluid on Downward-Facing Heating Surface

  • Wang, Yun;Wu, Junmei
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.915-924
    • /
    • 2016
  • After a severe accident to the nuclear reactor, the in-vessel retention strategy is a key way to prevent the leakage of radioactive material. Nanofluid is a steady suspension used to improve heat-transfer characteristics of working fluids, formed by adding solid particles with diameters below 100nm to the base fluids, and its thermal physical properties and heat-transfer characteristics are much different from the conventional working fluids. Thus, nanofluids with appropriate nanoparticle type and volume concentration can enhance the heat-transfer process. In this study, the moving particle semi-implicit method-meshless advection using flow-directional local grid method is used to simulate the bubble growth, departure, and sliding on the downward-facing heating surface in pure water and nanofluid (1.0 vol.% $Al_2O_3/H_2O$) flow boiling processes; additionally, the bubble critical departure angle and sliding characteristics and their influence are also investigated. The results indicate that the bubble in nanofluid departs from the heating surface more easily and the critical departure inclined angle of nanofluid is greater than that of pure water. In addition, the influence of nanofluid on bubble sliding is not significant compared with pure water.

Effect of Angle and Density of Grooves between Friction Plate Segments on Drag Torque in Wet Clutch of Automatic Transmission (마찰재 그루브에 따른 습식 클러치 드래그 토크 변화 연구)

  • Ryu, Jin Seok;Sung, In-Ha
    • Tribology and Lubricants
    • /
    • v.30 no.2
    • /
    • pp.71-76
    • /
    • 2014
  • As the importance of transmission efficiency to reducing fuel consumption and conserving the environment rapidly increases, reducing the drag torque in an automotive wet clutch is emerging as an important issue in the automotive industry. The drag torque in a clutch occurs from viscous drag generated by automatic transmission fluid in the narrow gap between separate friction plates. In this study, the drag torques in an automotive wet clutch are investigated with respect to the angle and density of the grooves between separate friction plates by three-dimensional finite element simulation of a single set of wet clutch disks considering the two-phase flow of air and oil. The simulation results shows that the drag torque generally increases with the rotational speed to a critical point and then decreases at the high-speed regime. The grooves between the plates plays an important role in reducing the drag peak, and the inclined angle of the grooves affects the oil flow. The grooves with an angle of $50^{\circ}$ shows the lowest drag torques at both low and high speeds. The flow vectors inside the $50^{\circ}$ grooves shows clear evidence that the fluid flows out more easily from the grooves compared with the flow vectors inside grooves with lower angles. The simulation results shows that increasing the number of grooves (density of grooves) decreases the drag torque.

Coupling effects of vortex-induced vibration for a square cylinder at various angles of attack

  • Zheng, Deqian;Ma, Wenyong;Zhang, Xiaobin;Chen, Wei;Wu, Junhao
    • Wind and Structures
    • /
    • v.34 no.5
    • /
    • pp.437-450
    • /
    • 2022
  • Vortex-induced vibration (VIV) is a significant concern when designing slender structures with square cross sections. VIV strongly depends on structural dynamics and flow states, which depend on the conditions of the approaching flow and shape of a structure. Therefore, the effects of the angle of attack on the coupling effects of VIV for a square cylinder are expected to be significant in practice. In this study, the aerodynamic forces for a fixed and elastically mounted square cylinder were measured using wind pressure tests. Aerodynamic forces on the stationary cylinder are firstly discussed by comparisons of variation of statistical aerodynamic force and wind pressure coefficient with wind angle of attack. The coupling effect between the aerodynamic forces and the motion of the oscillating square cylinder by VIV is subsequently investigated in detail at typical wind angels of attack with occurrence of three typical flow regimes, i.e., leading-edge separation, separation bubble (reattachment), and attached flow. The coupling effect are illustrated by discussing the onset of VIV, characteristics of aerodynamic forces during VIV, and interaction between motion and aerodynamic forces. The results demonstrate that flow states can be classified based on final separation points or the occurrence of reattachment. These states significantly influence coupling effects of the oscillating cylinder. Vibration enhances vortex shedding, which creates strong fluctuations in aerodynamic forces. However, differences in the lock-in range, aerodynamic force, and interaction process for angles of attack smaller and larger than the critical angle of attack revealed noteworthy characteristics in the VIV of a square cylinder.

A Study of the Relation Between Nozzle Geometry, Internal flow and Sprays Characteristics in Diesel Fuel Injection Systems

  • Payri, Raul;Molina, S.;Salvador, F.J.;Gimeno, J.
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.7
    • /
    • pp.1222-1235
    • /
    • 2004
  • This study examines the influence of geometry on the internal flow and macroscopic behavior of the spray in Diesel nozzles. For this investigation, two bi-orifice nozzles were employed: one cylindrical and one conical. The first step is to use a non-destructive characterization method which is based on the production of silicone moulds so that the precise internal geometry of the two nozzles can be measured. At this stage the nozzles have been characterized dimensionally and therefore the internal flow can be studied using CFD calculations. The results gained from this experiment make it possible also to ascertain the critical cavitation conditions. Once the critical cavitation conditions have been identified, the macroscopic parameters of the spray can be studied in both cavitating and non-cavitating conditions using a test rig pressurized with nitrogen and with the help of a image acquisition system and image processing software. Consequently, research can be carried out to determine the influence that cavitation has on macroscopic spray behavior. From the point of view of the spray macroscopic behavior, the main conclusion of the paper is that cavitation leads to an increment of the spray cone angle. On the other hand, from the point of view of the internal flow, the hole outlet velocity increases when cavitation appears. This phenomenon can be explained by the reduction in the cross section of the liquid phase in the outlet section of the hole.

The Hydrodynamic Stability of Natural Convection Flows Adjacent to an Inclined Isothermal Surface Submerged in Cold, Pure Water (순수한 찬물속에 잠겨있는 경사진 등온벽면 부근의 자연대류에 관한 수동력학적 안정성)

  • Hwang, Y.K.;Jang, M.R.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.4
    • /
    • pp.268-278
    • /
    • 1990
  • Hydrodynamic stability equations are formulated for natural convection flows adjacent to a heated or cooled, inclined, isothermal surface in pure water at $4^{\circ}C$, where the density variation with temperature becomes nonlinear. The resulting stability equations, when reduced to ordinary differential equations by a similarity transformation, constitute a two-point boundary-value problem, which was solved numerically. It is found from the obtained stability results that the neutral stability curves are systematically shifted to have lower critical Grashof numbers, as the inclination angle of upward-facing plate increases. Also, the nose of the neutral stability curve becomes blunter as the angle increases. It implies that the greater the inclination of the upward-facing plate, the more susceptible of the flow to instability for the wide range of disturbance wave number and frequency.

  • PDF

Experimental Study on the Performance of a Turbopump Inducer

  • Hong, Soon-Sam;Kim, Jin-Sun;Park, Chang-Ho;Kim, Jinhan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.240-244
    • /
    • 2004
  • Characteristics of steady and unsteady cavitation in a turbopump inducer were investigated in this paper. To see the effect of tip clearance on the inducer performance, three cases of tip clearance were tested. The helical inducer, which has two blades with inlet tip blade angle of 7.8 degree and tip solidity of 2.7, was tested in the water. In the non-cavitating condition, the inducer head decreased with increase in the tip clearance. Rotating cavitation and cavitation surge were observed through unsteady pressure measurements at the inducer inlet. The cell number and propagation speed of the rotating cavitation were determined through cross-correlation analysis. During the rotating cavitation one cell rotated at the same rotational speed as that of the inducer rotation and the cavitation surge did not rotate. The critical cavitation number increased with increase in the tip clearance at the same flow rate, but the change of critical cavitation number was small at the nominal flow rate.

  • PDF

Reduced Scale Model Experiments and Numerical Simulation for Flow Uniformity in de-NOx SCR Reactor (배연탈질 SCR 반응기내 유동균일 화를 위한 축소모형실험 및 전산해석)

  • 이인영;김동화;이정빈;류경옥
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.4
    • /
    • pp.347-354
    • /
    • 2001
  • SCR (Selective Catalytic Reduction) process is presently considered as one of the most effective techniques for removing nitric oxides from exhaust gases. In this study, based on the conceptually designed SCR reactor of 500 MW coal fired power plant. a reduced scale (1/20) SCR reactor model was made to analyze the flow pattern in front of catalyst layer according to the guide vane's design factors such as the number, interval, and angle of vanes. The results of the test were compared to those numerical simulation in order to assure the reliability of two methods. On the basis of our study. the critical Reynolds number (2.0$\times$ 10$^{5}$ ) was proposed for ensuring the similarity between the reduced scale model and the prototype of SCR reactor. Optimum design parameters of guide vanes were determined as follows, 4 vanes, the first vane angle of 93$^{\circ}$, and the vane intervals of 0.85 S/n, 1.05 S/n, 1.1 S/n, 1.0S/n, 1.0S/n (S: the distance of duct, n: the number of guide vanes). The excellent agreement between the results of the numerical simulation and the reduced scale model provides the validation of two methods for prediction of flow through SCR reactor.

  • PDF