• 제목/요약/키워드: Critical Load

검색결과 1,578건 처리시간 0.033초

Leipholz 기둥의 안정성에 미치는 자유단의 탄성구속과 말단질량의 영향 (Influence of Elastic Restraint and Tip Mass at Free End on Stability of Leipholz's Column)

  • 윤한익;박일주;김영수
    • 소음진동
    • /
    • 제7권1호
    • /
    • pp.91-97
    • /
    • 1997
  • An analysis is presented on the stability of an elastic cantilever column having the elastic restraints at its free end, carrying an added tip mass, and subjected to uniformly distributed follower forces. The elastic restraints are formed by both a translational spring and a rotatory spring. For this purpose, the governing equations and boundary conditions are derived by using Hamilton's principle, and the critical flutter loads and frequencies are obtained from the numerical evaluation of the eigenvalue functions of this elastic system. The added tip mass increases as a whole the critical flutter load of the elastic cantilever column, but the presence of its moment of inertia of mass has a destabilizing effect. The existence of the translational and rotatory springs at the free end increases the critical flutter load of the elastic cantilever column. Nevertheless, their effects on the critical flutter load are not uniform because of their coupling. The translational spring restraining the free end of the cantilever column decreases the critical flutter load by coupling with a large value of tip mass, while by coupling with the moment of inertia of tip pass its effect on the critical flutter load is contrary. The rotatory spring restraining the free end of the cantilever column increases the critical flutter load by coupling with the tip mass, but decreases it by coupling with the moment of inertia of the tip mass.

  • PDF

주기 하중을 받는 3-자유절점 공간 트러스의 동적 불안정 현상과 주파수 특성 (Dynamic Snapping and Frequency Characteristics of 3-Free-Nodes Spatial Truss Under the Periodic Loads)

  • 손수덕;황경주
    • 한국공간구조학회논문집
    • /
    • 제20권4호
    • /
    • pp.149-158
    • /
    • 2020
  • The governing equation for a dome-type shallow spatial truss subjected to a transverse load is expressed in the form of the Duffing equation, and it can be derived by considering geometrical non-linearity. When this model under constant load exceeds the critical level, unstable behavior is appeared. This phenomenon changes sensitively as the number of free-nodes increases or depends on the imperfection of the system. When the load is a periodic function, more complex behavior and low critical levels can be expected. Thus, the dynamic unstable behavior and the change in the critical point of the 3-free-nodes space truss system were analyzed in this work. The 4-th order Runge-Kutta method was used in the system analysis, while the change in the frequency domain was analyzed through FFT. The sinusoidal wave and the beating wave were utilized as the periodic load function. This unstable situation was observed by the case when all nodes had same load vector as well as by the case that the load vector had slight difference. The results showed the critical buckling level of the periodic load was lower than that of the constant load. The value is greatly influenced by the period of the load, while a lower critical point was observed when it was closer to the natural frequency in the case of a linear system. The beating wave, which is attributed to the interference of the two frequencies, exhibits slightly more behavior than the sinusoidal wave. And the changing of critical level could be observed even with slight changes in the load vector.

BASINS-SWAT 모델을 이용한 경안천 유역의 비점원 오염배출 중점관리 대상지역 결정 (Decision of Critical Area Due to NPS Pollutant Loadings from Kyongan Stream Watershed using BASINS-SWAT)

  • 장재호;윤춘경;정광욱;손영권
    • 한국농공학회논문집
    • /
    • 제51권5호
    • /
    • pp.69-78
    • /
    • 2009
  • In order to improve water quality of upper watershed of Paldang reservoir, it is necessary to evaluate non-point source pollution loads and identify critical watershed pollution sources. A GIS based Soil and Water Assessment Tool was applied to evaluate model application and reliability, estimate NPS pollution load, identify critical watershed by NPS pollution sources, and suggest various best management practices for Kyongan Stream watershed. Yearly NPS pollution loads were estimated 30.0% SS, 60.1% TN and 35.4% TP, respectably. The watershed pollution load is mainly decided by precipitation condition and SS and nutrients load have a significant regression relationship. Based on 10-year average yearly NPS pollution load, critical sub-watersheds were identified. The No. 5 and 17 which have lots of relatively intensive agricultural fields and scattered industrial area were vary critical sub-watersheds and under more intensive pollution load. In order to control critical watershed, watershed best management practices such as scientific fertilizer, contour farming and parallel terrace, transferring the sloppy farmland to grass or forest and constructing a buffer zone, and constructing wetlands and retention ponds will be applied. Overall the SWAT model can be efficiently used for identification of critical sub-watersheds in order to develop a priority watershed management plan to reduce water pollutions.

지지조건을 고려한 낮은 포물선 아치의 동적 임계하중의 해석 (An Analysis of Dynamic Critical Loads for Low Parabolic Arches with Different End Conditions)

  • 박승범
    • 한국농공학회지
    • /
    • 제28권2호
    • /
    • pp.87-92
    • /
    • 1986
  • The differential equation, which can determine the dynamic critical loads for low parabcoic arches, is derived in this study. The dynamic critical loads of the parabolic arches subjected to a concentrated step load are nummerically analyzed for the changes of load positions. In cases of arches with different end conditions (both hinged, fixed hinged, both fixed), the effect of end conditions and that of the rises are investigated in detail. The summary of the results are the following: 1)The snapthrough does not occur when the rise of arch is very low, and the bifurcation appears clearly as the rise of arch increases. 2)The regions in which the dynamic critical loads are not defined for the both ends fixed are broader than that for the both ends hinged. 3)For all case, the load positions of minimum dynamic critical loads exsit at the near position from the end hinged. Thus, the results obtained in present study show that the magnitude of dynamic critical loads, the load positions of minimum dynamic critical loads and the regions in which the dynamic critical loads are not defined depend on end conditions of arches.

  • PDF

Leipholz 기둥의 안정성에 미치는 자유단의 탄성구속과 말단질량의 영향 (Influence of Elastic Restraints and Tip Mass at Free End on stability of Leipholz Column)

  • 윤한익;박일주;진종태;김영수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 춘계학술대회논문집; 부산수산대학교, 10 May 1996
    • /
    • pp.309-315
    • /
    • 1996
  • An analysis is presented on the stability of elastic cantilever column subjected to uniformly distributed follower forces as to the influence of the elastic restraints and a tip mass at the free end. The elastic restraints are formed by both the translational and the rotatory springs. For this purpose, the governing equations and boundary conditions are derived by using Hamilton's principle, and the critical flutter loads and frequencies are obtained from the numerical evaluation of the eigenvalue functions of this elastic system. The added tip mass increases as a whole the critical flutter load in this system, but the presence of its moment of inertia of mass has a destabilizing effect. The existence of the translational and rotatory spring at the free end increases the critical flutter load of the elastic cantilever column. Nevertheless their effects on the critical flutter load are not uniform because of their coupling. The translational spring restraining the end of cantilever column decreases the critical flutter load by coupling with a large value of tip mass, while by coupling with the moment of inertia of tip mass its effect on the critical flutter load is contrary. The rotatory spring restraining the free end of cantilever column increases the critical flutter load by coupling with the tip mass, but decreases it by coupling with the moment of inertia of tip mass.

  • PDF

압입 시험에 의한 플라즈마 세라믹 용사코팅의 특성 평가 (Evaluation of the characteristics of plasma sprayed ceramic coatings by Indentation test)

  • 최세영;채영훈;김석삼
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.248-254
    • /
    • 2002
  • The most controversial topics in plasma sprayed ceramic coating system are recently mechanical properties such as bond strength, cohesive strength, toughness and so on. Determination of bond strength of coatings is one of the most important problems. In the industry, the bond strength of coating system has been estimated by Pull-off test(ASTM standard C633-79). But, without a fixed jig and specimen, it is impossible to obtain the bond strength. Therefore, it is necessary to study the critical fracture load on interface of the coating by indentation test. Because the critical fracture load plays an important role in evaluating the bond strength for plasma sprayed ceramic coating system. So, we have estimated critical fracture load in plasma sprayed ceramic coating system, and it was shown that inverse relationship between the cross-section hardness of coating and the critical fracture load(Pc). In case of the high load(1kgf, 2kgf) in $Al_{2}O_{3}+13%TiO_{2}$, it was found that the critical point(Pco), which the coating was broken on.

  • PDF

계통연계 인버터의 주요 부하 불평형 시 상전류 제어를 통한 부하 상전압 평형 제어 (An Output Voltage Balance Control of Grid Connected Inverter by Phase Current Control at Critical Load Unbalanced Condition)

  • 박태현;김학원;조관열;민준기;최원일
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.22-29
    • /
    • 2023
  • A grid-connected inverter can be used in grid-connected or stand-alone modes. Generally, a grid-connected inverter operates in a grid-connected mode, but the inverter operates in stand-alone mode if grid faults occur. In the stand-alone mode, the grid-connected inverter must supply electric power to a critical load that needs to receive stable power even though grid faults occur. Generally, three-phase loads are used as critical loads, but a single phase is configured in some cases. In these conditions, the critical load is required to unbalance the load power consumption, which makes the three-phase load voltage unbalancd. This unbalanced voltage problem can cause fatal problems to the three-phase critical loads, and thus must be addressed. Hence, this paper proposes an algorithm to solve this unbalanced voltage problem by the individual phase current control. The proposed method is verified using Psim simulation and experiments.

Buckling behavior of composite cylindrical shells with cutout considering geometric imperfection

  • Heidari-Rarani, M.;Kharratzadeh, M.
    • Steel and Composite Structures
    • /
    • 제30권4호
    • /
    • pp.305-313
    • /
    • 2019
  • Creating different cutout shapes in order to make doors and windows, reduce the structural weight or implement various mechanisms increases the likelihood of buckling in thin-walled structures. In this study, the effect of cutout shape and geometric imperfection (GI) is simultaneously investigated on the critical buckling load and knock-down factor (KDF) of composite cylindrical shells. The GI is modeled using single perturbation load approach (SPLA). First, in order to assess the finite element model, the critical buckling load of a composite shell without cutout obtained by SPLA is compared with the experimental results available in the literature. Then, the effect of different shapes of cutout such as circular, elliptic and square, and perturbation load imperfection (PLI) is investigated on the buckling behavior of cylindrical shells. Results show that the critical buckling load of a shell without cutout decreases by increasing the PLI, whereas increasing the PLI does not have a great impact on the critical buckling load in the presence of cutout imperfection. Increasing the cutout area reduces the effect of the PLI, which results in an increase in the KDF.

대용량 MCFC 발전시스템을 이용한 비상부하 전력 공급 장치 설계 및 제어방법 (Design and Control Method for Critical Load Supply Equipment using MCFC Electricity Generation Systems)

  • 김동희;김종수;최규영;이병국;곽철훈
    • 전력전자학회논문지
    • /
    • 제16권1호
    • /
    • pp.20-29
    • /
    • 2011
  • 본 논문에서는 동특성이 느린 용융탄산염 연료전지 (Molten Carbonate Fuel Cell, MCFC) 스택을 사용하여 계통사고 시 추가적인 UPS (Uninterruptible Power Supply) 없이 비상부하 (Critical Load)로 전력 공급이 가능하고, 사고 발생 후에도 정격전력으로 발전 가능한 비상부하 추종형 백업 시스템을 제안한다. 제안된 MCFC 발전 시스템용 비상부하 추종형 백업 시스템은 3상 인버터로 구성된 PCS (Power Conditioning System) 출력단에 3상 PWM 컨버터를 연결한 구조이고, 비상부하 추종이 가능한 추가적인 제어 알고리즘을 가지는 Load Leveler를 제어한다. 제안된 비상부하 추종형 백업 시스템의 회로와 제어 알고리즘의 타당성을 5kW 기반의 컴퓨터 시뮬레이션을 통하여 검증한다.

가늘고 긴 소형로켓의 비행특성에 영향을 주는 외력에 기인한 임계하중에 관한 연구 (A study on critical load due to external force influencing on flight characteristics of a small slender body rocket.)

  • 고태식;나선화
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.393-397
    • /
    • 2007
  • 이 연구의 목적은 추력, 항력, 중량 등의 외력들에 기인하여 가늘고 긴 동체의 소형로켓의 비행궤도에 영향을 줄 수 있는 임계하중을 조사하는데 있다. 임계하중은 먼저 Euler 기둥식을 이용하여 구하였고, 검증을 위해 유한 요소법의 수치해석 결과와 비교하였다.

  • PDF