• Title/Summary/Keyword: Critical Line

Search Result 998, Processing Time 0.027 seconds

Longitudinal reaction on conductors due to tornado wind load

  • Dingyu Yao;Ashraf El Damatty
    • Wind and Structures
    • /
    • v.38 no.4
    • /
    • pp.325-339
    • /
    • 2024
  • The longitudinal force resulting from tornado loads on transmission line is considered a crucial factor contributing to the failure of transmission line structures during tornado events. Accurate estimation of this longitudinal force poses a challenge for structural designers. Therefore, the objective of this paper is to provide a set of charts that can be easily used to estimate the peak longitudinal forces transferred from the conductors to a tower. The critical wind field and corresponding configuration considered in this paper are previously studied and determined. The charts should account for all the conductor parameters that can affect the value of the longitudinal force. In order to achieve that, a parametric study is first conducted to assess the variation of the longitudinal forces with different conductor parameters, based on the critical tornado configuration. Results of this parametric study are used to develop the charts that can be used to calculate longitudinal forces by adopting a multi-variable line regression. The forces calculated from charts are validated by finite element analysis. An example for the usage of the charts is provided at the end of this paper.

THE AVERAGING VALUE OF A SAMPLING OF THE RIEMANN ZETA FUNCTION ON THE CRITICAL LINE USING POISSON DISTRIBUTION

  • Jo, Sihun
    • East Asian mathematical journal
    • /
    • v.34 no.3
    • /
    • pp.287-293
    • /
    • 2018
  • We investigate the averaging value of a random sampling ${\zeta}(1/2+iX_t)$ of the Riemann zeta function on the critical line. Our result is that if $X_t$ is an increasing random sampling with Poisson distribution, then $${\mathbb{E}}{\zeta}(1/2+iX_t)=O({\sqrt{\;log\;t}}$$, for all sufficiently large t in ${\mathbb{R}}$.

Critical Thinking and Debate Education under Non-Face-to-Face Situation - Through Online classes for Freshmen at the Engineering College (비대면 환경에서의 비판적 사고와 토론교육 - 공대 신입생 대상 온라인 수업 사례를 중심으로)

  • Shin, Heesun
    • Journal of Engineering Education Research
    • /
    • v.24 no.1
    • /
    • pp.34-45
    • /
    • 2021
  • This research is a case study about "Critical Thinking and Debate Education" class which was done for freshmen at the engineering college of "S" Women's University. Real time remote classes through LMS and ZOOM were the most effective tools under on-line circumstances, considering the fact that video lectures only cannot cultivate students' capabilities of critical thinking and communication. Throughout the analysis on students' self-reflection journals and lecture evaluations, this paper examined considerable future points and the pros and cons of "Critical Thinking and Debate Education" under online presentation and discussion situation. As research outputs, students told they could feel less nervousness and anxiety when they exercise and have a presentation because they could choose familiar space for them. In addition, students also told that they feel comfortable about both self-feedback and peer evaluation, repeatedly seeing the recorded video clip. However, on the contrary, sometimes students felt uncomfortable due to unstable internet connection through the online classes, and they also were regretful about the missing chances of interaction between a teacher and students and of intimate exchanges among students. They also told they had felt a kind of limit of enhancing their presentation skills just in front of the monitor. Considering these outcomes, this research paper points out that online education needs to be proceeded by strengthening multi layered feedback to students with the build-up of a non-face-to-face stable educational infrastructure, application of online instructional strategy, and utilization of YouTube platform and video contents. Through this research paper, I hope the new system of encompassing on/off line "Critical Thinking and Debate Education" and effective teaching and learning method can be developed soon by strengthening the strength of online education.

Nonlinear Finite Element Analysis for Mooring Chain Considering OPB/IPB (OPB/IPB를 고려한 계류체인의 비선형 수치해석)

  • Kim, Min-suk;Kim, Yooil
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.299-307
    • /
    • 2017
  • The design of the mooring line to maintain the position of an offshore structure in rough marine environments is recognized as a very important consideration. Conventional fatigue evaluation of a mooring line was performed by considering the tensile force acting on the mooring line, but the mooring line broke after 238 days in the girassol area even though the expected fatigue life was expected to be longer. The causes of this event are known to be due to OPB/IPB (out-of-plane bending/in-plane bending) caused by chain link friction due to the excessive tensile strength of the mooring line. In this study, three models with different boundary conditions were proposed for fatigue analysis of a mooring line considering OPB/IPB. Interlink stiffness was calculated by nonlinear structure analysis and a stress concentration factor was derived. In addition, the sensitivity of interlink stiffness according to the magnitude of tensile force, large deformation effect, and coefficient of friction was analyzed, and the effect of critical elastic slip and bending moment calculation position on interlink stiffness was confirmed.

Proposed Landslide Warning System Based on Real-time Rainfall Data (급경사지 붕괴위험 판단을 위한 강우기반의 한계영역 설정 기법 연구)

  • Kim, Hong Gyun;Park, Sung Wook;Yeo, Kang Dong;Lee, Moon Se;Park, Hyuck Jin;Lee, Jung Hyun;Hong, Sung Jin
    • The Journal of Engineering Geology
    • /
    • v.26 no.2
    • /
    • pp.197-205
    • /
    • 2016
  • Rainfall-induced landslide disaster case histories are typically required to establish critical lines based on the decrease coefficient for judging the likelihood of slope collapse or failure; however, reliably setting critical lines is difficult because the number of nationwide disaster case histories is insufficient and not well distributed across the region. In this study, we propose a method for setting the critical area to judge the risk of slope collapse without disaster case history information. Past 10 years rainfall data based on decrease coefficient are plotted as points, and a reference line is established by connecting the outermost points. When realtime working rainfall cross the reference line, warning system is operating and this system can be utilized nationwide through setting of reference line for each AWS (Automatic Weather Station). Warnings were effectively predicted at 10 of the sites, and warnings could have been issued 30 min prior to the landslide movement at eight of the sites. These results indicate a reliability of about 67%. To more fully utilize this model, it is necessary to establish nationwide rainfall databases and conduct further studies to develop regional critical areas for landslide disaster prevention.

Aero-elastic response of transmission line system subjected to downburst wind: Validation of numerical model using experimental data

  • Elawady, Amal;Aboshosha, Haitham;El Damatty, Ashraf
    • Wind and Structures
    • /
    • v.27 no.2
    • /
    • pp.71-88
    • /
    • 2018
  • At the University of Western Ontario (UWO), numerical tools represented in semi-closed form solution for the conductors and finite element modeling of the lattice tower were developed and utilized significantly to assess the behavior of transmission lines under downburst wind fields. Although these tools were validated against other finite element analyses, it is essential to validate the findings of those tools using experimental data. This paper reports the first aeroelastic test for a multi-span transmission line under simulated downburst. The test has been conducted at the three-dimensional wind testing facility, the WindEEE dome, located at the UWO. The experiment considers various downburst locations with respect to the transmission line system. Responses obtained from the experiment are analyzed in the current study to identify the critical downburst locations causing maximum internal forces in the structure (i.e., potential failure modes), which are compared with the failure modes obtained from the numerical tools. In addition, a quantitative comparison between the measured critical responses obtained from the experiment with critical responses obtained from the numerical tools is also conducted. The study shows a very good agreement between the critical configurations of the downburst obtained from the experiment compared to those predicted previously by different numerical studies. In addition, the structural responses obtained from the experiment and those obtained from the numerical tools are in a good agreement where a maximum difference of 16% is found for the mean responses and 25% for the peak responses.

Development of Enhanced Contingency Screening and Selection Algorithm for On-line Transient Security Assessment (과도안전도 평가를 위한 개선된 상정고장 선택 및 여과 알고리즘 개발)

  • Kim Yong-Hak;Song Sung-Geun;Nam Hae-Kon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.6
    • /
    • pp.306-314
    • /
    • 2005
  • In this paper, a new approach that is based on EEAC & only with network solutions for CS&S in the transient stability assessment is developed. The proposed CS&S algorithm in conjunction with EEAC to include the capability of performing on-line TSA without TDS is used to calculate the critical clearing time for stability index. In this algorithm, all generators are represented by classical models and all loads are represented by constant impedance load models. The accelerating & synchronizing power coefficient as an index is determined at its disturbance through solving network equation directly. As mentioned above, a new index for generator is generally used to determine the critical generators group. The generator rotor angle is fixed for non-critical generators group, but has equal angle increments for critical generators group. Finally, the critical clearing time is calculated from the power-angle relationship of equivalent OMIB system. The proposed CS&S algorithm currently being implemented is applied to the KEPCO system. The CS&S result was remarkably similar to TSAT program and SIME. Therefore, it was found to be suitable for a fast & highly efficient CS&S algorithm in TSA. The time of CS&S for the 139 contingencies using proposed CS&S algorithm takes less than 3 seconds on Pentium 4, 3GHz Desktop.

Erlotinib-Related Spontaneous Pneumothorax in Patient with Primary Lung Cancer

  • Nam, Hae-Seong;Lee, Hyeon-Jeong;Kim, Min-Su;Park, Sung-Wook;Jeon, Sang-Hoon;Cho, Jae-Hwa;Kwak, Seung-Min;Lee, Hong-Lyeol;Ryu, Jeong-Seon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.6
    • /
    • pp.465-468
    • /
    • 2010
  • Spontaneous pneumothorax (SPTx) associated with primary lung cancer is quite rare, but has been reported as the initial presentation or a complication of disease progression. Moreover, chemotherapy-related SPTx in primary lung cancer occurs at a very low frequency, accounting for less than 0.05% of all cases. Here, we report the first case of erlotinib-related SPTx in a patient with advanced lung adenocarcinoma in Korea. After 3 cycles of cisplatin-based chemotherapy as first-line therapy, erlotinib was administered as second-line treatment. Asymptomatic SPTx accompanied by a significant decrease in tumor size was observed in the left lung 7 weeks later. The patient received continuous administration of erlotinib, without additional treatment. This case showed that SPTx can occur in patients with primary lung cancer receiving erlotinib, and asymptomatic chemotherapy-related SPTx in primary lung cancer may not require therapeutic intervention.

Numerical Study of Particle Motion and Particle Beam Formation Through a Critical Orifice (임계 오리피스를 통과한 입자의 운동특성과 입자 빔에 관한 수치적 연구)

  • Ahn, Jin-Hong;Ahn, Kang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1240-1247
    • /
    • 1999
  • Particle motion through a disk type critical orifice placed in a 3.0cm diameter chamber has been studied numerically. In the simulation, the velocity field is solved using Pantankar's SIMPLER algorithm for the compressible flow and convergence of the computation is confirmed if the mass source at each control volume is smaller than $10^{-7}$. The particle motion in the flow field is solved in Lagrangian method. The particle trajectories showed that the particles injected away from the center line are expanded rapidly. At lower pressures, this expansion phenomena are more dominant. At lower pressures, the clear difference in particle and air speed is showed all the way down to the exit plan. It was found that particles with Stokes number of ca.2.5 tend to focus close to the center line very well except the particles travelling near the wall. However, particles with Stokes number greater than ca.2.5 show a tendency to cross the center line.

Study of Single-Stage High-Power-Factor Electronic Ballast for fluorescent lamps operating in critical conduction mode (임계모드에서 동작하는 단일 전력단을 갖는 고역률 형광등용 전자식 안정기에 관한 연구)

  • Seo, C.S.;Kim, D.H.;Byun, Y.B.;Lee, P.S.;Sim, K.Y.;Oh, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1126-1128
    • /
    • 2001
  • A single-stage high-power-factor electron ic ballast operating in critical conduction mode is presented in this paper. The proposed topology is based on integration of a boost-like converter and a LCC Type half-bridge serial resonant inverter. The power-factor-correction(PFC) stage is a boost-like converter operating in critical conduction mode for positive and negative half cycle voltage respectively at line frequency (60Hz) so that a high power factor is achieved naturally. The simulated and experimental results for 100w fluorescent lamps operating at 42kHz switching frequency and 220V line voltage have been obtained.

  • PDF