• Title/Summary/Keyword: Critical Facility

Search Result 315, Processing Time 0.027 seconds

Organizational Reform for the Successful Implementation of Infrastructure Asset Management using Balanced Score Cards (균형성과지표를 활용한 사회기반시설 자산관리 조직 개선 방안)

  • Chae, Myung Jin;Park, Ha Jin;Lee, Gu;Lee, Geon Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6D
    • /
    • pp.745-752
    • /
    • 2009
  • Management of social infrastructure has been advanced from facility management (FM) to asset management (AM), which adopts the aggressive and proactive methods in predicting the deterioration of infrastructure, prevents failures, and eventually saves maintenance cost. Infrastructure asset management is not a simple engineering technique, but it is a new paradigm evolved from facility management practices. To implement the infrastructure asset management successfully, organizational reform is very important. This paper suggests critical success factors and key performance indicators to implement the infrastructure asset management for facility managers of government owned social infrastructures such as roads and bridges. Reorganizing the facility management group requires new vision, objectives, strategies for the paradigm-changing asset management. This paper uses Balanced Score Card (BSC) which is a proven method in measuring and setting new objectives for an organization. Once the performance indicators are reviewed repeatedly by facility managers through experts workshops, developed BSC can be used in practice. This paper discusses the development of robust BSC scoring method through in depth literature reviews and investigation of asset management practices of domestic and international cases.

Flutter performance of central-slotted plate at large angles of attack

  • Tang, Haojun;Li, Yongle;Chen, Xinzhong;Shum, K.M.;Liao, Haili
    • Wind and Structures
    • /
    • v.24 no.5
    • /
    • pp.447-464
    • /
    • 2017
  • The flutter instability is one of the most important themes need to be carefully investigated in the design of long-span bridges. This study takes the central-slotted ideal thin flat plate as an object, and examines the characteristics of unsteady surface pressures of stationary and vibrating cross sections based on computational fluid dynamics (CFD) simulations. The flutter derivatives are extracted from the surface pressure distribution and the critical flutter wind speed of a long span suspension bridge is then calculated. The influences of angle of attack and the slot ratio on the flutter performance of central-slotted plate are investigated. The results show that the critical flutter wind speed reduces with increase in angle of attack. At lower angles of attack where the plate shows the characteristics of a streamlined cross-section, the existence of central slot can improve the critical flutter wind speed. On the other hand, at larger angles of attack, where the plate becomes a bluff body, the existence of central slot further reduces the flutter performance.

CRITICAL HEAT FLUX FOR DOWNWARD-FACING BOILING ON A COATED HEMISPHERICAL VESSEL SURROUNDED BY AN INSULATION STRUCTURE

  • Yang, J.;Cheung, F.B.;Rempe, J.L.;Suh, K.Y.;Kim, S.B.
    • Nuclear Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.139-146
    • /
    • 2006
  • An experimental study was performed to evaluate the effects of surface coating and an enhanced insulation structure on the downward facing boiling process and the critical heat flux on the outer surface of a hemispherical vessel. Steady-state boiling tests were conducted in the Subscale Boundary Layer Boiling (SBLB) facility using an enhanced vessel/insulation design for the cases with and without vessel coatings. Based on the boiling data, CHF correlations were obtained for both plain and coated vessels. It was found that the nucleate boiling rates and the local CHF limits for the case with micro-porous layer coating were consistently higher than those values for a plain vessel at the same angular location. The enhancement in the local CHF limits and nucleate boiling rates was mainly due to the micro-porous layer coating that increased the local liquid supply rate toward the vaporization sites on the vessel surface. For the case with thermal insulation, the local CHF limit tended to increase from the bottom center at first, then decrease toward the minimum gap location, and finally increase toward the equator. This non-monotonic behavior, which differed significantly from the case without thermal insulation, was evidently due to the local variation of the two-phase motions in the annular channel between the test vessel and the insulation structure.

CRITICAL FLOW EXPERIMENT AND ANALYSIS FOR SUPERCRITICAL FLUID

  • Mignot, Guillaume;Anderson, Mark;Corradini, Michael
    • Nuclear Engineering and Technology
    • /
    • v.40 no.2
    • /
    • pp.133-138
    • /
    • 2008
  • The use of Supercritical Fluids(SCF) has been proposed for numerous power cycle designs as part of the Generation IV advanced reactor designs, and can provide for higher thermal efficiency. One particular area of interest involves the behavior of SCF during a blowdown or depressurization process. Currently, no data are available in the open literature at supercritical conditions to characterize this phenomenon. A preliminary computational analysis, using a homogeneous equilibrium model when a second phase appears in the process, has shown the complexity of behavior that can occur. Depending on the initial thermodynamic state of the SCF, critical flow phenomena can be characterized in three different ways; the flow can remain in single phase(high temperature), a second phase can appear through vaporization(high pressure low temperature) or condensation(high pressure, intermediate temperature). An experimental facility has been built at the University of Wisconsin to study SCF depressurization through several diameter breaks. The preliminary results obtained show that the experimental data can be predicted with good agreement by the model for all the different initial conditions.

Criteria of Installing Delineators Considering Human Factors (인간공학적인 시선유도시설 설치기준에 관한 연구)

  • Park, Je-Jin;Park, Tae-Hoon;Ha, Tae-Jun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.2
    • /
    • pp.100-109
    • /
    • 2008
  • Traffic accidents at night occur more than any other time because of improper road light facility and delineators. Therefore, cost-effective criteria of installing delineators are needed instead of expensive road light facility, especially, on rural road including light volume of traffic. This paper presents the criteria of installing 'Chevron Alignment Sign' considering driver's visual behavior characteristics and 'Raised Pavement Marker' considering critical encroachment angie of both straight section and curve one in order to reduce both the number of accidents on curve sections and the number of road encroachment accidents, respectively. The characteristics of visual behaviors can be expressed by visual angle involving curve radius and intersection angle. The estimated installing angles are $1^{\circ}{\sim}2.5^{\circ}$ by radii, which is based on changes in sensitivity across visual field by exogenous attention. Also, the raised pavement marker is installed every 2m, 3m, and 4m considering critical encroachment angles by radii.

  • PDF

Development of the Computer-Assisted HACCP System Program and Developing HACCP-Based Evaluation Tools of Sanitation for Institutional Foodservice Operations (단체급식의 HACCP 전산프로그램 및 위생관리 평가도구 개발)

  • 이정숙;홍희정;곽동경
    • Korean Journal of Community Nutrition
    • /
    • v.3 no.4
    • /
    • pp.655-667
    • /
    • 1998
  • The Computer-assisted Hazard Analysis and Critical Control Point(HACCP) program has been developed for a systematic implementation of HACCP principles in identifying, assessing and controlling hazards in institutional foodservics operations. The HACCP-based sanitation evaluation tool has been developed, based on the results of the computerized assisted HACCP program in 4 service sites of C contracted foodservice company, including 2 general hospitals with 650-beds, one office operation of 400 meals per day, and one factory foodservice of 1,000 meals per day. All database files and processing programs were created by using Unify Vision tool with Windows 95 of user environments. The results of this study can be summarized as follows : 1. This program consists of the pre-stage for HACCP study and the implementation stage of the HACCP system. 1) The pre-stage for HACCP study includes the selection of menu items, the development of the HACCP recipe, the construction of product flow diagrams, and printing the HACCP recipes and product flow diagrams. 2) The implementation of the HACCP system includes the identification of microbiological hazards, the determination of critical control points based on the decision tree base files. 3) The HACCP-based sanitation evaluation tool consisted of 3 dimensions of time-temperature relationship, personal hygiene, and equipment-facility sanitation. The Cronbach's alphas calculation indicated that the tool was reliable. The results showed that the focus groups rated the mean of importance in time-temperature relationship, personal hygiene, and equipment-facility sanitation as 4.57, 4.59 and 4.55 respectively. Based on the results, this HACCP-based sanitation evaluation tool was considered as an effective tool for assuring product quality. This program will assist foodservice managers to encourage a standardized approach in the HACCP study and to maintain a systematic approach for ensuring that the HACCP principles are applied correctly.

  • PDF

Power control of CiADS core with the intensity of the proton beam

  • Yin, Kai;Ma, Wenjing;Cui, Wenjuan;He, Zhiyong;Li, Xinxin;Dang, Shiwu;Yang, Feng;Guo, Yuhui;Duan, Limin;Li, Meng;Hou, Yikai
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1253-1260
    • /
    • 2022
  • This paper reports the control method for the core power of the China initiative Accelerator Driven System (CiADS) facility. In the CiADS facility, an intense external neutron source provided by a proton accelerator coupled to a spallation target is used to drive a sub-critical reactor. Without any control rod inside the sub-critical reactor, the core power is controlled by adjusting the proton beam intensity. In order to continuously change the beam intensity, an adjustable aperture is considered to be used at the Low Energy Beam Transport (LEBT) line of the accelerator. The aperture size is adjusted based on the Proportional Integral Derivative (PID) controllers, by comparing either the setting beam intensity or the setting core power with the measured value. To evaluate the proposed control method, a CiADS core model is built based on the point reactor kinetics model with six delayed neutron groups. The simulations based on the CiADS core model have indicated that the core power can be controlled stably by adjusting the aperture size. The response time in the adjustment of the core power depends mainly on the adjustment time of the beam intensity.

Earthquake hazard and risk assessment of a typical Natural Gas Combined Cycle Power Plant (NGCCPP) control building

  • A. Can Zulfikar;Seyhan Okuyan Akcan;Ali Yesilyurt;Murat Eroz;Tolga Cimili
    • Geomechanics and Engineering
    • /
    • v.35 no.6
    • /
    • pp.581-591
    • /
    • 2023
  • North Anatolian Fault Zone is tectonically active with recent earthquakes (Mw7.6 1999-Kocaeli and Mw7.2 1999-Düzce earthquakes) and it passes through Marmara region, which is highly industrialized, densely populated and economically important part of Turkey. Many power plants, located in Marmara region, are exposed to high seismic hazard. In this study, open source OpenQuake software has been used for the probabilistic earthquake hazard analysis of Marmara region and risk assessment for the specified energy facility. The SHARE project seismic zonation model has been used in the analysis with the regional sources, NGA GMPEs and site model logic trees. The earthquake hazard results have been compared with the former and existing earthquake resistant design regulations in Turkey, TSC 2007 and TBSCD 2018. In the scope of the study, the seismic hazard assessment for a typical natural gas combined cycle power plant located in Marmara region has been achieved. The seismic risk assessment has been accomplished for a typical control building located in the power plant using obtained seismic hazard results. The structural and non-structural fragility functions and a consequence model have been used in the seismic risk assessment. Based on the seismic hazard level with a 2% probability of exceedance in 50 years, considered for especially these type of critical structures, the ratios of structural and non-structural loss to the total building cost were obtained as 8.8% and 45.7%, respectively. The results of the study enable the practical seismic risk assessment of the critical facility located on different regions.

Core${\cdot}$Quality${\cdot}$Basic Service Factors of Family Restaurants and Differentiation Strategy for Customer Service Management (패밀리 레스토랑의 핵심${\cdot}$고품질${\cdot}$기본서비스 요인과 요인 별 고객관리 차별화 전략에 관한 연구)

  • Park, Jung-Young
    • Journal of the Korean Society of Food Culture
    • /
    • v.23 no.2
    • /
    • pp.184-193
    • /
    • 2008
  • The purpose of this study was to determine the detailed customer satisfaction and dissatisfaction factors of family restaurants in Korea, and to then classify the factors into 3 groups, inlcuding core service, quality service, and basic service. ‘Core service’ represents the critical factors that generate both satisfaction and dissatisfaction; ‘quality service’ generates only satisfaction; and ‘basic service’ generates only dissatisfaction. This categorization is based on Herzberg’s motivation-hygiene theory (1976) as well as Cadotte & Turgeon (1988). Based on the characteristics of the three groups, differentiation strategies in managing customer service were suggested to the family restaurant managers. A qualitative research method, termed the critical incident technique (CIT), was used in the study. This method helps researchers find new factors or attributes by grouping key issues from the anecdotes (critical incidents) and then categorizing common factors from the key issues. This research categorized key satisfiers and dissatisfiers into 33 factors, which were from 402 critical incidents described by 261 respondents. Eleven factors (response to service failures, food taste and quality, attention paid to customers, coupon/mileage point/discount card, customer’s ordinary requests, waiting, food diversity, food price, facility sanitation, checking out, customer’s special requests) were classified into core service, which required maximum management not regarding the level of customer satisfaction. Six factors (employee attitude, event, education and explanation, complementary food, customer’s mistakes, attention paid to children) were classified into quality service, which required differentiation strategy management. Finally, nine factors (speed of food service, employee’s mistakes, food sanitation, atmosphere and interior, seating, forcing orders, parking, other customers, reservations) were classified into basic service, which required minimum management at the level of the industry standards.

Study for Reducing Safety Distance by Installing Ammunition Storage Facility in Underground (탄약저장시설 지하화에 따른 안전거리 축소방안 연구)

  • Park, Sangwoo;Jun, Jonghoon;Choi, Hangseok;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.253-260
    • /
    • 2020
  • With increasing interest in an underground-type ammunition storage facility, several design results have been provided recently. However, since not only experts in the tunnel but also military persons in charge of ammunition have not fully understood the safety distance standard, reliable design results are not being produced. In this study, the effective design method of an underground-type ammunition storage facility was provided by analyzing the current safety distance standard. First, the critical safety distances that dominate the size of construction site for underground-type ammunition storage facilities were evaluated, which are the layout of chambers and the configuration of the entrances. Then, the decreasing effect of inter-chamber distance was studied according to the rock type and the storage density of ammunition. In addition, the method of designing tunnels with parallel lines and two-floors was considered for arranging more chambers while complying with the safety distance standards. In particular, numerical simulations were carried out to determine the satisfaction of the safety distance standards when an underground-type ammunition storage facility is composed of two-floor and the decreasing effect of inter-chamber distance according to the inner explosive pressure reduction. Finally, the method to adjust the size of entrances and the path of pressure were studied for decreasing the safety distance at the entrance.