• Title/Summary/Keyword: Crack Examination

Search Result 104, Processing Time 0.035 seconds

EFFECTS OF ER:YAG LASER ABLATION ON THE DENTIN (Er:YAG 레이저를 이용한 치아삭제 효과)

  • Choi, Nam-Ki;Yang, Kyu-Ho;Park, Sang-Won;Kim, Ok-Joon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.683-693
    • /
    • 2001
  • The purpose of this study was to evaluate the effects of Er:YAG laser on cutting efficacy and its histologic findings. Dentin specimens of human premolars and molars were used and irradiated by Er:YAG laser with noncontact handpiece type delivery system under different treatment condition of irradiation time. Cavity pattern and volume were evaluated to determine the cutting efficacy and following results were obtained. 1. Cutting volume of sound dentin was getting larger with time immersed in water increase 2. With the condition of irradiation (150mJ, 10Hz, 30sec), surface irregularity was more increased in sound dentin comparing to carious dentin. For the light microscopic examination, dentinal tubules were opened and ash flecks and cracks were noted with inconsistence of dentinal tubules. 3. In case of 30 sec. irradiation in carious dentin, dark zone was limited to small focus whereas 1 min. irradiation, more wider, and cracks were noted in the perpendicular to direction of dentinal tubules. For the 2 min. irradiation, cavity was the widest and more cracks were found.

  • PDF

THE EFFECT OF THE 5-FLUOROURACIL ON THE HAIR OF RAT : SCANNING ELECTRONMICROSCOPIC STUDY (5-Fluorouracil이 백서 체모에 미치는 영향에 관한 실험적 연구)

  • Choi, Yong-Chul;Kim, Kyung-Wook;Lee, Jae-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.2
    • /
    • pp.158-165
    • /
    • 1998
  • This study was undertaken to observe the effects of the antineoplastic agent, 5-Fluorouracil(5 FU) on the hair in Sprague-Dawley white rats. Twenty four sprague-Dawley strain white rats, each weighing about 150-200 grams were used and divided into control and experimental groups. In the experimental group, eighteen rats were injected intraperitonially with 60 mg of 5-FU per killogram body weight with one time per two days, Six rats were injected with 0.5 cc of normal saline solution intraperitoneally as a placebo on this control group. Rats were serially sacrificed on the first, third, fifth, seventh, tenth and fourteenth day after 2 times of injection of 5-FU and saline. The hair were obtained and observed SEM. After examination and comparision of all specimens, the results of this study were as follows: 1. In the control group, the scale and cuticle of hair was observed smooth surface and equal interval 2. In the experimental group, the first day, scale change was seen from body of hair and crack was seen. from fifth day, and irregular scale and cuticle of hair was seen from 10, 14 days 3. The apperance of root of hair was not almost change From above results, 5-Fluorouracil was more effective on the hair body. The change was begun from first day and crack of scale was seen from fifth day and irregular scale and cuticle of hair was seen from 10,14 days. The.

  • PDF

FATIGUE DESIGN OF BUTT-WELDED TUBULAR JOINTS

  • Kim, D. S.;S. Nho;F. Kopp
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.127-132
    • /
    • 2002
  • Recent deepwater offshore structures in Gulf of Mexico utilize butt welded tubular joints. Application of welded tubular joint includes tendons, production risers, and steel catenary risers. Fatigue life assessment of these joints becomes more critical because the structures to which they are attached are allowed to undergo cyclic and sometimes large displacements around an anchored position. Estimating the fatigue behavior of these tubular members in the design stage is generally conducted by using S-N curves specified in the codes and standards. Applying the stress concentration factor of the welded structure to S-N approach often results in very conservative assessment because the stress field acting on the tubular has a non-uniform distribution through the thickness. Fracture mechanics and fitness for service (FFS) technology have been applied in the design of the catenary risers. This technology enables the engineer to establish proper requirements on weld quality and inspection acceptance criteria to assure satisfactory structural integrity during its design life. It also provides guidance on proper design curves to be used and a methodology for accounting for the effects of non-uniform stress distribution through the wall thickness. An attempt was made to develop set of S-N curves based on fracture mechanics approach by considering non-uniform stress distribution and a threshold stress intensity factor. Series of S-N curves generated from this approach were compared to the existing S-N curves. For flat plate butt joint, the S-N curve generated from fracture mechanics matches with the IIW class 100 curve when initial crack depth was 0.5 mm (0.02"). Similar comparison with API X′ was made for tubular joint.. These initial crack depths are larger than the limits of inspection by current Non-destructive examination (NDE) means, such as Automatic Ultrasonic Inspection (AUT). Thus a safe approach can be taken by specifying acceptance criteria that are close to limits of sizing capability of the selected NDE method. The comparison illustrates conservatism built into the S-N design curve.

  • PDF

A Case of Gunshot Injury to the Spinal Cord in a Cat:Clinical, Surgical, and Computed Tomographic Features (고양이 척수 총상 증례: 임상소견, 수술소견, 컴퓨터단층영상소견)

  • Ahn, Seoung-Yob;Yoon, Hun-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.32 no.2
    • /
    • pp.187-190
    • /
    • 2015
  • An 18-month-old female spayed domestic short-haired cat, weighing 4.1 kg, was presented as an emergency case after it suffered a gunshot injury. Physical examination of the cat revealed paraplegia, with loss of deep nociception. A bullet (diameter, 3 mm) lodged in the left epaxial muscle at the level of the first lumbar (L1) was observed on radiographic examination, and a hyperattenuating spot in the spinal canal was confirmed using computed tomography. Exploratory laminectomy was performed, and an incomplete fracture of the right caudal articular process of L1 and a necrotizing spinal cord lesion were found. The animal was euthanized and necropsy was performed, which revealed a crack on the left pedicle of L1. This case report presents the first detailed clinical description of a gunshot injury to the spinal cord in a cat.

Scientific Conservation Treatment of the Celadon Jar with the Inscription of 'the Fourth Sunhwa Year'(National Treasure No.326) (국보 제326호 청자 '순화4년'명 항아리의 과학적 보존처리)

  • Lee, Sun Myung;Kwon, Oh Young;Park, Jongseo;Han, Woo Rim
    • Journal of Conservation Science
    • /
    • v.35 no.5
    • /
    • pp.453-469
    • /
    • 2019
  • The celadon jar with inscription of 'the Fourth Sunhwa Year' is an important chronology that shows the conditions of production of the early celadon due to the inscription on the bottom including its purpose, application, and the producer. This celadon jar has been restored several times in the past. However, concerns over the structural stability, such as the separation and level differences in the joined cracks, have risen because of the aging of the repair materials, which were subjected to various environmental changes over a long time. By examining the conditions of preservation, the major damage was identified as the '入' shaped crack on the front, the 'V' shaped restored part and the crack on its left side, and the 'J' shaped crack on the back side. In the past, the cracks were found to be joined using a refined lacquer containing camphor, drying oil, rosin, etc. mixed with soil powder. The joint line was repainted with the refined lacquer and covered with gold powder. The missing parts were restored with gypsum and colored with acrylic color. After that, the repair materials were aged and emergency treatment was performed at the National Museum of Korea in 1981. At that time, Cemedine C or Cemedine C mixed with microballoons was used for reinforcing the cracks. Conservation treatment focused on removing the past repair materials and reinforcing the physically fragile parts by joining and restoring them based on the examination of the preservation condition. in addition, the area around the restored part was colored for future exhibition.

A Novel Method to Fabricate Tough Cylindrical Ti2AlC/Graphite Layered Composite with Improved Deformation Capacity

  • Li, Aijun;Chen, Lin;Zhou, Yanchun
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.4
    • /
    • pp.369-374
    • /
    • 2012
  • Based on the structure feature of a tree, a cylindrical $Ti_2AlC$/graphite layered composite has been fabricated through heat treating a graphite column and six close-matched thin wall $Ti_2AlC$ cylinders bonded with the $Ti_2AlC$ powders at $1300^{\circ}C$ and low oxygen partial pressure. SEM examination reveals that the bond interlayers between cylinders or that between cylinder and column are not fully dense without any crack formation. During the compressive test, the strain of the $Ti_2AlC$/graphite layered composite is about twice higher than that of the monolithic $Ti_2AlC$ ceramic, and the compressive strength of the layered composite is 348 MPa. The layered composite show the noncatastrophic fracture behaviors due to the debonding and shelling off of the layers, which are different from the monolithic $Ti_2AlC$ ceramic. The mechanism of the improved deformation capacity and noncatastrophic failure modes are attributed to the presence of the central soft graphite column and cracks deflection by the bond interlayers.

Composite Fracture Detection Capabilities of FBG Sensor and AE Sensor

  • Kim, Cheol-Hwan;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.27 no.4
    • /
    • pp.152-157
    • /
    • 2014
  • Non-destructive testing methods of composite materials are very important for improving material reliability and safety. AE measurement is based on the detection of microscopic surface movements from stress waves in a material during the fracture process. The examination of AE is a useful tool for the sensitive detection and location of active damage in polymer and composite materials. FBG (Fiber Bragg Grating) sensors have attracted much interest owing to the important advantages of optical fiber sensing. Compared to conventional electronic sensors, fiber-optical sensors are known for their high resolution and high accuracy. Furthermore, they offer important advantages such as immunity to electromagnetic interference, and electrically passive operation. In this paper, the crack detection capability of AE (Acoustic Emission) measurement was compared with that of an FBG sensor under tensile testing and buckling test of composite materials. The AE signals of the PVDF sensor were measured and an AE signal analyzer, which had a low pass filter and a resonance filter, was designed and fabricated. Also, the wavelength variation of the FBG sensor was measured and its strain was calculated. Calculated strains were compared with those determined by finite element analysis.

A Study on the Damage of the Three Storied Stone Pagoda of Bulguksa Temple in GyeongJu (경주 불국사 삼층석탑(석가탑) 파손원인에 관한 연구)

  • Ji, Sung-Jin
    • Journal of architectural history
    • /
    • v.22 no.6
    • /
    • pp.47-58
    • /
    • 2013
  • The purpose of this study is to analyze the cause of damage to the three storied stone pagoda of Bulguksa temple in GyeongJu. This report is attempted to making reinforcement and conservation plan through investigating and analyzing the cause of damage to that. The damage is caused by occurring of stress, degrading of stone strength, changing of underground soil structure, natural disasters and so on. Compressive stress, shear stress, bending stress and lateral pressure affected to the pagoda since built up. Ultrasonic examination data tells the strength of the stone. According to this result, strength of the stereobate stone materials is enough to support the weight of the upper ones. But we could found many other factors of the damage could consider, for example the problems occurred on building the pagoda construction and the weakness of the stone material(soft rock). And many environmental factors being changed in soil structure(subsidence of soil and degradation of bearing power of soil and freezing and melting of soil) can be seen as the cause of the damage. Natural disasters like earthquake, lightning and heavy rain were also thought to give direct impact to the damage. At last Concentration of compressive stress caused the crack and exfoliation on the stone materials and shear stress, bending stress and lateral pressure were main causes of the stereobate stone materials shearing.

Ductile Fracture Behaviour of SA 533B Pressure Vessel Steel Under Mixed Mode (I/II) Loading (혼합 모드(I/II) 하중에 의한 SA533B 압력용기강의 연성파괴 특성에 관한 연구)

  • O, Dong-Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1829-1834
    • /
    • 2001
  • The aim of this study is to investigate the ductile fracture behavior under mixed mode (I/II) loading using SA533B pressure vessel steel. Anti-symmetric 4-point (AS4P) bonding tests were performed to obtain the J-R curves under two different mixed mode (I/II) loadings. In addition, the fractographic examination of fracture surfaces was carried out to compare with those of pure Mode I and Mode II. In conclusions, the J-R curves under Mixed Mode (I/II) loading were located between those of Mode I and Mode II loadings. When the mixture ratio of mixed mode (I/II) loading was high, the J-R currie of mixed mode (I/II) loading approached that of pure mode I loading after some amount of crack propagation. In contrast with the above fact, if the mixture ratio was low, the J-R curve looked after that of pure mode II loading. The fractographic evidences such as the shape of dimples under different loading conditions supported these conclusions.

Comparative Study on Crack Tip Opening Displacment ${\delta}_5$ R-Curve and ${\delta}_{BS}$ R-Curve (균열선단 열림변위 {\delta}_5 R-곡선과 {\delta}_{BS} R-곡선의 비교연구)

  • Kim, Eom-Gi;Nam, Seung-Hun;Jin, Uk;Go, Seong-Wi
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.3 s.174
    • /
    • pp.794-802
    • /
    • 2000
  • Since the examination of CTOD problem revealed that the discrepancy among CTOD's was a matte., of definition, the relationships among parameters based on different definitions have been studied Particularly, the relationship between $\sigma$BS R-curve based on BS 7448 and R-curve based on the recently introduced $\sigma$5 parameter was investigated in this research. For the comparison, compact tension specimens of used 1Cr-0.5Mo steel, heat treated 1Cr-0.5Mo steel to mimic the new one, A12024-T6, and A12024-T351 were prepared and tested. Consequently, the relationship between $\sigma$5 and $\sigma$BS R-curves for tested materials were established by shifting the rotational center which could determined by rotation factor and ligament size.