• Title/Summary/Keyword: Crack Examination

Search Result 104, Processing Time 0.034 seconds

A Study on the Application on Site and Stability of Broken Rail Detection Equipment (레일절손검지장치 현장적용 및 안정화에 관한 연구)

  • Choi, Si-Haeng;Cha, Gwan-Bong;Lee, Jong-Seong;Chung, Su-Young;Lee, Hi-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2082-2089
    • /
    • 2011
  • This study is examination of application on site for performance and stability of real-time broken rail detection equipment development system about connection, welded part occurring data errors of broken rail monitoring system. As a result of analysis about data collected in Seoul Metro No.2 Subway from Mar. 2010 to Jan. 2011, we found it is possible to detect crack location(Thermit welding) within the margin of error of ${\pm}1m$ accurately as the first attenuation was -1.2dB and the second was -1.3dB.

  • PDF

The Influence of CNTs and Lamination Structure on the Intralaminar Fracture of CFRP/GFRP Composites (CFRP/GFRP 복합재료의 층내 파괴에 대한 CNT 및 적층구조의 영향)

  • Kim, Seong Hun;Yun, Yu Seong;Kang, Ji Woong;Kwon, Oh Heon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.9-15
    • /
    • 2017
  • Recently many researches were conducted on the interlaminar fracture that is a delamination between laminates by using ASTM standardized methods. However the experiment of the intralaminar a fracture is difficulty. In this study, four types of CFRP/GFRP composites with different layer structures were compared to evaluate an intralaminar fracture toughness under the mode I. Also the CNTs were added to the layer for the examination of the fracture toughness improvement. And the characteristics of the crack propagation behaviour was observed using a microscope. The obtained results can be useful for the evaluation of the intralaminar fracture toughness of the CNT reinforced CFRP/GFRP composites.

Application of Thin Bonded Concrete Overlay for Concrete Pavement Rehabilitation using Type III Cement (조강시멘트를 이용한 도로포장 박층 덧씌우기 공법의 실용화 연구)

  • 박정준;백상현;정재헌;엄주용;윤경구;엄태선
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.493-498
    • /
    • 1999
  • Many concrete pavements closed to the end of service life in out country need to repair. We investigated material and mix designs for thin bonded concrete overlay and applied it to concrete pavement rehabilitation. The concrete with Type III cement showed earlier strength and better durability than the concrete with Type I cement. Designed concrete mixture with TypeIII cement made it possible to open the road earlier against heavy vehicles, increased traffic despite of cold weather in winter. In the field examination after four month, there was no defects like as shrinkage crack, spalling, surface abrasion and scaling, and good traffic condition has been maintained.

  • PDF

Toughening of Ni Bonded $Cr_3C_2$ by Mo Particulates (Mo 입자에 의한 Ni 결합 $Cr_3C_2$의 고인성화)

  • 한동빈;장철우;백성기;박병학
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.6
    • /
    • pp.429-432
    • /
    • 1993
  • Cr3C2 material is characterized by high chemical stability and poor sinterability with low strength [50~150MPa]. In his study, low melting temperature nickel powder was used to improve sinterability as well as strength. In addition, molydenum particles were added to the Ni-bonded Cr3C2 cermet pseudomatrix to increase resistance to fracture. The specimens made by hot-pressing under vacuum and strength was measured by 4-point bending. Indentation cracking and fractographic examination were conducted to study the interaction of the indentation cracks with the reinforcing particles. Toughening mechanisms and failure will be discussed in terms of crack/particle interactions and compared with previous works.

  • PDF

Quantitative Evaluation for the Internal Defect Size Governing the Fatigue Life in Ductile Irons (구상흑연주철의 피로수명을 지배하는 내재결함부 크기는 정량적 평가)

  • 김진학;김민건
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.11
    • /
    • pp.2742-2748
    • /
    • 2000
  • In this study, the quantitative evaluation was performed by examination for gatigue crack origin in two prepared ductile irons specimens which have different microstructures using rotary bending fatigue tester, Series A has mixed microstructure. ferrite plus pearlite, and series B has bainitic microstructure. Obtained main results are as follows. The scatterings of fatigue strength were observed on σ(sub)α-Ν diagram of both specimen series, and it is observed that scatterings of series A were more serious. It is reasonable to evaluate the size of mesocrack range by means of √A(원문참조), where A means the area of mesocrack range including globular graphite nodule. As a result of reconsideration for the fatigue data by introduction of K(sub)α-Ν diagram, the scattrings of fatigue life were, remarkably. reduced. Therefore, it is more reasonable to evaluate of mesocrack range on fatigue life by parameter K(sub)α rather than σ(sub)α.

A Study on the Convection Heat Transfer Coefficient in Concrete at Early Ages (초기재령 콘크리트의 외기대류계수에 관한 연구)

  • 김진근;전상은;양은익;송영철;방기성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.151-156
    • /
    • 1997
  • The setting and hardening of concrete is accompanied by nonlinear temperature distribution caused by developing heat of cement hydration. expecially at early ages, nonlinear temperature distribution has a large influence n the crack evaluation. So the need to predict the exact temperature history in concrete has led to the examination thermal properties. In this study, the convection heat transfer coefficient is experimentally investigated which is one of the thermal properties in concrete. Furthermore, the result of the experiment is compared with those of analysis by the program which is developed in KAIST. As a result of comparison, the analytical results are in good approximation with experimental data.

  • PDF

Examination of Applicability of Repair Mortar using Very High Early Strength Cement (초속경시멘트를 이용한 보수모르터의 현장적용성 검토)

  • Jeon Jin Hwan;Kasai Hiroshi;Yazaki Hideaki;Cho Chung Ki
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.309-312
    • /
    • 2004
  • The hydraulic structure of the hydroelectric power plant such as aqueduct tunnels and the drainage canal became old. Therefore, because the concrete surface of the aqueduct tunnel has received severe damage by wear-out and the crack etc the repair is demanded. This research examined the applicability of the repair mortar which mixed the fly ash and an artificial aggregate by using the very high early strength cement. As a result, good Quality repair mortar which satisfied the demand performance more than self-flow 270mm and compressive strength $50N/mm^2$ (age of 28days) adjusting of water cement ratio by using the MTX cement be able to be manufactured.

  • PDF

Static Creep Characteristics of AI-10wt% TiCp Composites (Al-10wt% TiCp복합재료의 정적 크립특성)

  • Rhim, J.K.;Park, J.K.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.6 no.3
    • /
    • pp.159-165
    • /
    • 1993
  • Creep tests of the TiC particulate reinforced Al composite have been conducted in the temperature ranges from 200 to $500^{\circ}C$. The steady-state cree rate of the composite depended strongly on the temperature and ap' plied stress. The stress exponent for the steady state creep rate of the composites was approximately 17.5 and the activation anergy was calculated to be 390KJ/mol. The steady-state creep equation could be written as $\acute{\varepsilon}_{ss}$ $$(s^{-1})=1.5{\times}10^{-9}\;{\sigma}^{17.5}\exp(-390000/RT)$$. Fracture surface examination showed that the fracture mode of the particulate reinforced composite was ductile by plastic tearing of the aluminum matrix and TiC particle interfaces were offered as sites for crack.

  • PDF

Stress Corrosion Cracking of Heat Exchanger Tubes in District Heating System

  • Cho, Sangwon;Kim, Seon-Hong;Kim, Woo-Cheol;Kim, Jung-Gu
    • Corrosion Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.49-54
    • /
    • 2019
  • The purpose of this paper is to present failure analysis, of the heat exchanger tube in a district heating system. SS304 stainless steel is used, as material for the heat exchanger tube. The heat exchanger operates in a soft water environment containing a small amount of chloride ions, and regularly repeats operation and standstill period. This causes concentration of chloride ions on the outer surface of the tube, as well as repeat of thermal expansion, and shrinkage of the tube. As a result of microscopic examination, cracks showed transgranular as well as branched propagation, and many pits were present, at the initiation point of each crack. Energy disperstive spectroscopy analysis showed Fe and O peak, as well as Cl peak, meaning that cracks were affected by Cl ion. Failure of the tube was caused by chloride-induced stress corrosion cracking by thermal stress, high temperature, and localized enrichment of chloride ions.

The quality improvement study on the crack of heat exchanger lubricating oil port in military aircraft (군용항공기 열교환기 윤활유 유입포트 균열개선 연구)

  • Park, Sung-Jae;Choi, Jae-Ho;Choi, Gil-Gyu;Lee, Dong-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.164-172
    • /
    • 2020
  • The fuel oil/heat exchanger installed in military aircraft is a device that cools the lubricant oil supplied to other devices, such as an AMAD, and a hydraulic pump using the low temperature of the fuel is cracked at the AMAD lubricant inlet port. If a crack in the heat exchanger occurs, the lubricant oil supplied to other equipment is not cooled. Therefore, the flight can no longer be performed. In this study, non-destructive inspection and microscopic examination of the fracture surface of the oil port were performed to analyze the crack tendency. The oil pipe connected to the oil port is a titanium pipe, which is fastened with over torque and has been identified as the leading cause of heat exchanger oil port cracks. In addition, it was verified as the main reason for cracking by finite element analysis. The material and diameter of the pipe were changed to improve this defect, and the applied torque was adjusted. In addition, the bending value of the pipe was adjusted to minimize the fatigue accumulation due to pulsating pressure. As a result, no cracks occurred on the heat exchanger via the ground test after the installation of an improved pipe under the same conditions.