• 제목/요약/키워드: Cr

Search Result 9,314, Processing Time 0.034 seconds

The Clinical Examination of Netspeg Lens for Good Visual Acuity (시력 개선을 위한 Netspeg 렌즈의 임상적 검증)

  • Kim, Douk-Hoon;Bae, Han-Young;Kim, Sun-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.281-291
    • /
    • 2006
  • The aim of this study was performed the clinical test using Netspeg lens for good visual acuity on subjects with abnormal refraction status. The subjects of one hundreds adults (fifty males, fifty females, mean=21 years, range=19 to 24) were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, systemic disease and ocular disease. The refraction test was recorded the monocular and binocular using objective method. Visual acuity was performed the binocular status using the Netspeg lens and CR-39. Stereopsis test was performed the titmus fly and TNO at near distance using Netspeg lens and CR-39. The P-VEP test was used the 16 pattern size(Bausch Lomb, production in USA) with three channels. Also Subjects viewed the p-vep stimulus with binocular vision through the corrected visual acuity using the Netspeg lens and CR-39. The contrast sensitivity test was performed the contrast sensitivity chart(pelli-Robertson, USA) at 1m distance using the Netspeg lens and CR-39. The ultrastructure of surface on the Netspeg lens and CR-39 was observed the SEM(JMS-5800, made in Japan). The results of this study was as follows: 1. In corrected visual acuity of abnormal refraction using the Netspeg lens and CR-39, the Netspeg lens wearer were acquired the good visual field and clear visual acuity comparative to CR-39 wearer in the subject vision test. however the comfort of visual acuity was similar results in the Netspeg lens and CR-39. Also the subjects of Netspeg lens wearer was good visual acuity more than CR-39 wearer and in the analysis of P-VEP, the amplitude of wave on Netspeg lens used appears to be better through the CR-39(p>0.5). Besides, on the contrast sensitivity, the Netspeg lens wearer was good results than CR-39. The value on stereopsis with TNO by Netspeg lens wearer was better than CR-39 in results. However, in the stereopsis test with Titmus, the Netspeg lens and CR-39 wearer was similar results. 2. The ultrastructure of Netspeg lens surface was the smooth and fine shape more than CR-39. Also, Netspeg lens have a fine line structure in ultrastructure. In conclusion, the results of this study conformed that the surface ultrastructure of Netspeg lens used is more specific pin hole design structure than CR-39. This study indicated that the vision of Netspeg lens used have a better than CR-39 in the corrected visual acuity for abnormal refraction eye. Therefore, In this paper, we suggested that the ultrastructure and line structure of Netspeg lens was related to good visual function. However the visual function of the aspheric Netspeg and ultra waterproof Netspeg lens was similar results.

  • PDF

Cr(III)-Tetraaza Macrocyclic Complexes Containing Auxiliary Ligands (Part I); Synthesis and Characterization of Cr(III)-Benzoato and Chlorobenzoato Macrocyclic Complexes

  • Byun, Jong-Chul;Kim, Goo-Cheul;Han, Chung-Hun
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.7
    • /
    • pp.977-982
    • /
    • 2004
  • The reaction of $cis-[Cr([14]-decane)(OH_2)_2]^+$ ([14]-decane = rac-5,5,7,12,12,14-hexamethyl-1,4,8,11-teraazacyclotetradecane) with auxiliary ligands {$L_a$ = benzoate(bz) or chlorobenzoate(cbz)} leads to a new compound $[Cr([14]-decane)(bz)_2]ClO_4$ or $[Cr([14]-decane)(cbz)_2]ClO_4$. These complexes have been characterized by a combination of elemental analysis, conductivity, IR and Vis spectroscopy, mass spectrometry, and X-ray crystallography. The crystal structure of $[Cr([14]-decane)(cbz)_2]^+$ was determined. The complex shows a distorted octahedral coordination environment with the macrocycle adopting a folded cis-V conformation. The angle $N_{axial}-Cr-N_{axial}$ deviates by $14.5^{\circ}$ from the ideal value of $180^{\circ}$for a perfect octahedron. The bond angle cis-O-Cr-O between the Cr(III) ion and the two carboxylate oxygen atoms of the monodentate p-chlorobenzoate ligands is close to 90$^{\circ}$. The FAB mass spectra of the $cis-[Cr([14]-decane)(La)_2]ClO_4$ display peaks due to the molecular ions $[Cr([14]-decane)(bz)_2-H]^\;,\;[Cr([14]-decane)(cbz)_2-2H]^$ at m/z 578, 646, respectively.

Influence of CrCl3 in Sphene-Pink Pigments (Sphene-Pink 안료에 미치는 CrCl3의 영향)

  • Lee, Hyun-Soo;Lee, Byung-Ha
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.5
    • /
    • pp.268-275
    • /
    • 2008
  • In high temperature ceramic glazes, a stable range of pink-red colors producing $Cr_2O_3-SnO_2-CaO-SiO_2$ pigments are factored by Cassiterite and Malayaite relationship with $Cr_2O_3$. The experiment described the effect of $CrCl_3$ by adding $H_3BO_3$ as a mineralizer to increase the formation of Malayaite crystal, substituting $CrCl_3$ instead of $Cr_2O_3$ in pigment as a chromophore. Synthesized pigments were analyzed by XRD, FT-IR, Raman Spectroscop, UV and UV-vis. The result shows the differences in amount of crystal phases and oxidation state of Cr ion, which causes the color change. The melting point of $CrCl_3$ is lower than $Cr_2O_3$ which act as a mineralizer and makes the pigment synthesized in lower temperature at $1200^{\circ}C$. Holding 3 h firing at $900^{\circ}C$ where the synthesize forms shows better effect of Malayaite crystal phases and increasing engaged effect of $CrCl_3$ where the color pigmentation is more defined then in $Cr_2O_3$.

Properties of Cr-N Films Prepared by the Arc-induced Ion Plating (아아크방전 유도형 이온플레이팅에 의한 Cr-N 피막의 특성)

  • Jeong, Jae In;Mun, Jong Ho;Hong, Jae Hwa;Gang, Jeong Su;Lee, Yeong Baek
    • Journal of the Korean institute of surface engineering
    • /
    • v.24 no.1
    • /
    • pp.24-24
    • /
    • 1991
  • Cr-N films were deposited on low-carbon steel sheets by the reactive arc-induced ion plating (AIIP). The influence of the deposition conditions (nitrogen pressure and substrate bias voltage) on the crystal orientation, morphology and microhardness of the Cr-N films has been investigated using x-ray diffractometer and scanning electron microscope. The impurities and contaminations on the surface and at the interface, and the layer-by-layer compositions of the film have been analyzed using scanning Auger multiprobe (SAM) and glow discharge spectroscope (GDS). The mixed state of Cr and Cr2N turned out to have a fine fibrous structure. The Cr2N films were deposited at a wide range of nitrogen flow rates. The orientations of Cr2N films were mainly (110) and (111), and the intensity of the (111) peak increased as the substrate bias voltage increased. The micorstructure of the Cr2N film was dense and no columnar structure was observed. The films in the mixed state of Cr2N and CrN were also dense without columnar structure. The maximum microhardness of the Cr-N films was 2400 kg/$\textrm{mm}^2$ at 10gf load.

Properties of Cr-N Films Prepared by the Arc-induced Ion Plating (아아크방전 유도형 이온플레이팅에 의한 Cr-N 피막의 특성)

  • 정재인;문종호;홍재화;강정수;이영백
    • Journal of the Korean institute of surface engineering
    • /
    • v.25 no.1
    • /
    • pp.24-33
    • /
    • 1992
  • Cr-N films were deposited on low-carbon steel sheets by the reactive arc-induced ion plating (AIIP). The influence of the deposition conditions (nitrogen pressure and substrate bias voltage) on the crystal orientation, morphology and microhardness of the Cr-N films has been investigated using x-ray diffractometer and scanning electron microscope. The impurities and contaminations on the surface and at the interface, and the layer-by-layer compositions of the film have been analyzed using scanning Auger multiprobe (SAM) and glow discharge spectroscope (GDS). The mixed state of Cr and Cr₂N turned out to have a fine fibrous structure. The Cr₂N films were deposited at a wide range of nitrogen flow rates. The orientations of Cr₂N films were mainly (110) and (111), and the intensity of the (111) peak increased as the substrate bias voltage increased. The microstructure of the Cr₂N film was dense and no columnar structure was observed. The films in the mixed state of Cr₂N and CrN were also dense without columnar structure. The maximum microhardness of the Cr-N films was 2400 kg/㎟ at 10 gf load.

  • PDF

Porcelain Bonding Strength and Mechanical Properties of Sintered Ni-Cr-Ti Alloy for Dental Prosthodontics (치과보철용 Ni-Cr-Ti 소결체합금의 포셀린결합력 및 기계적 특성)

  • Choe, Han-Cheol;Park, Seon-Yeong;Shim, Myung-Sub
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.6
    • /
    • pp.560-566
    • /
    • 2016
  • In this study, porcelain bonding strength and mechanical properties of sintered Ni-Cr-Ti alloy for dental prosthodontics have been researched experimentally. Mechanical and morphological characteristics of the alloys were examined by Vickers hardness test, tensile and bonding strength test, surface roughness test, field-emission scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction. In the sintered Ni-13Cr-xTi alloys, morphology of sintered alloy showed porous matrix diffused with alloying elements of Cr and Ti, and showed dendritic structure after melting process. From the XRD results, the second phases of NiCr, $Ni_3Cr$, and $Ni_3Ti$ were formed in the case of sintered and melted Ni-13Cr-xTi alloys. The tensile strength and hardness of Ni-13Cr-xTi alloys increased, as Ti content increased. Surface roughness increased, as Ti content increased. The bonding strength between metal and porcelain of Ni-13Cr-5Ti alloy was higher than those of Ni-13Cr and Ni-13Cr-10Ti alloys

Electrical Characteristics and Fabrication of NiCr/NiCrSi Alloy Film for High Precision Thin Film Resistors (고정밀급 박막저항을 위한 NiCr/NiCrSi박막의 제조 및 전기적 특성)

  • Lee, Boong-Joo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.6
    • /
    • pp.520-526
    • /
    • 2007
  • In order to acquire fundamental informations to fabricate high precision thin film resistors, NiCr/NiCrSi alloy films were prepared using Ni and Cr targets. Effect of composition on the electrical properties of the NiCr/NiCrSi alloy film were then investigated. Considering the effect of Si doping on the electrical and material characteristics, the lower TCR (temperature coefficient of resistance) values could be achieved for samples with Ni/Cr ratio of $0.8{\sim}1.5$ (in a range of relative higher specific resistivity and Cr composition of $40\;wt%{\sim}55\;wt%$) and with Si doping. Consequently, the sample prepared using a DC power showed a good TCR of $-25\;ppm/^{\circ}C$, which implies that increase of specific resistivity and decrease of TCR would be achieved more efficiently not for Ni-Cr binary material but for Si doped Ni-Cr ternary material, and not using RF power but using DC power in the sputtering process.

Pretreatment for Cu electroplating and Etching Property of Cu-Cr Film (Cu-Cr합금 박막의 구리 전기도금을 위한 전처리 및 에칭 특성에 관한 연구)

  • Kim, N. S.;Kang, T.;Yun, I. P.;Park, Y. S.
    • Journal of the Korean institute of surface engineering
    • /
    • v.26 no.3
    • /
    • pp.149-157
    • /
    • 1993
  • In the study of TAB(Tape Automated Bonding)technologies, Cu-Cr sputtered seed layer has been used to improve the adhesion between Polyimide and Cu film and electrical properties. But the Cu electrodeposit on Cu-Cr film had poor adhesion or powder-like form due to the surface Cr oxides on the Cu-Cr film. By means of activating the Cu-Cr film with the oxalic acid and phosphoric acid, the Cu film with the improved adhesion could be coated on the Cu-Cr sputtered film in CuSO4 solution. The etching rate was compared with increasing the Cr content of the sputtered Cu-Cr film, and anodic polarization curve in FeCl3 solution was investigated. With increasing the Cr content, the etching rate was reduced. The clean etching cross section could be obtained with increasing the concentration of FeCl3 solution. But above the 13 w/o Cr content, Cu-Cr sputtered film could not bed etched cleanly only with FeCl3 solution and additives were needed.

  • PDF

Effects of Si Addition on the Microstructure and Properties of Cr-Al alloy for High Temperature Coating (고온 코팅용 Cr-Al합금의 미세조직 및 특성에 미치는 Si 첨가의 영향)

  • Kim, Jeong-Min;Kim, Il-Hyun;Kim, Hyun-Gil
    • Korean Journal of Materials Research
    • /
    • v.29 no.1
    • /
    • pp.7-10
    • /
    • 2019
  • Cr-Al alloys are attracting attention as oxidation resistant coating materials for high temperature metallic materials due to their excellent high temperature stability. However, the mechanical properties and oxidation resistance of Cr-Al alloys can be further enhanced, and such attempts are made in this study. To improve the properties of Cr-Al alloys, Si is added up to 5 wt%. Casting specimens with different amounts of Si content are prepared by a vacuum arc remelting method and isothermally heated under steam conditions at $1,100^{\circ}C$ for 1 hour. The as-cast microstructure of low Si alloys is mainly composed of only a Cr phase, while $Al_8Cr_5$ and $Cr_3Si$ phases are also observed in the 5 % Si alloy. In the high Si alloy, only Cr and $Cr_3Si$ phases remain after the isothermal heating at $1,100^{\circ}C$. It is found that Si additions slightly decrease the oxidation resistance of the Cr-Al alloy. However, the microhardness of the Cr-Al alloy is observed to increase with an increasing Si content.

In Vivo H-1 MR Spectroscopy of Intracranial solid Tumors (두개강내 고형성 종양의 H-1 자기공명분광법)

  • 성수옥;장기현;한문희;연경모;한만청
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.86-93
    • /
    • 1997
  • Purpose: To assess the ability of in vivo H-1 MRS to determine the degree of malignancy and to characterize the histopathologic type of intracranial solid tumors. Materials and Methods: In vivo H-1 MR spectra of the pathologically-proven 81 intracranial soild tumors (low-grade glioma 17 cases, high-grade glioma 31 cases, lymphoma 9 cases, meningioma 8 cases, central neurocytoma 4 cases, medulloblastoma 3 cases, PNET 3 cases, metastasis 2 cases, others 4 cases) were analyzed. H-1 MR spectroscopy was performed on a 1.5T MR unit using PRESS sequence with a TR of 2000ms, a TE of 270 or 135ms and a voxel size of $2{\times}2{\times}2cm^3$ for all spectra. N-acetyl aspartate (NAA)/Creatine complex(Cr), Choline complex (Cho)/Cr, and lactate (Lac)/Cr ratios were measured on the peak heights of each resonance and compared among the different tumors. Results: All intracranial solid tumors demonstrated decreased NAA, elevated Cho and lactate, and variable Cr levels. All tumors showed increased Cho/Cr and Lac/Cr, whereas NAA/Cr level was decreased. Mean Cho/Cr and Lac/Cr ratios were significantly higher in high-grade gliomas than in low-grade gliomas. However, NAA/Cr ratio showed no significant difference between low-grade and high-grade gliomas. Very high Cho peaks were seen in lymphomas, meningiomas, medulloblastomas, and neurocytomas in addition to high-grade gliomas. Conclusion: H-1 MRS may be useful in differentiating between low-grade and high-grade gliomas, however cannot characterize the histologic types or subtypes of tumors.

  • PDF